Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • Siemens 3SK2122-1AA10 Safety Relay
    ❤ Add to collection
  • Siemens 3SK2122-1AA10 Safety Relay

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥42341.00
      ¥45256.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:12.470KG
    • Quantity:
    • (Inventory: 6322)
Description
<span style="font-size: 18px; font-family: arial;">Siemens 3SK2122-1AA10 Safety Relay</span>

Siemens 3SK2122-1AA10 Safety Relay

The Siemens 3SK2122-1AA10 is a compact safety relay from the 3SK2 series, designed for emergency stop circuits, safety gates, and light curtain monitoring. It provides three normally open (NO) safety outputs and one auxiliary normally closed (NC) output. The relay achieves safety integrity up to PL e (ISO 13849‑1) and SIL CL3 (IEC 61508). Its small width (22.5 mm) makes it ideal for space‑constrained control cabinets.

Technical Specifications

Supply voltage: 24 V DC (19.2‑28.8 V). Power consumption: 1.8 W. Inputs: single or dual channel (with or without cross‑circuit detection). Safety output contacts: 3 NO (force‑guided), rated for 6 A at 230 V AC / 24 V DC (AC‑15, DC‑13). Auxiliary output: 1 NC, 2 A. Response time: ≤ 100 ms (from input to output). Release time: < 30 ms. The relay has 4 screw terminals for the reset circuit (automatic or monitored manual reset). LEDs indicate power, input status, and output energised. Dimensions: 22.5 mm (W) x 100 mm (H) x 110 mm (D). Operating temperature -25°C to +60°C. Protection rating IP20. The unit is DIN rail mountable (35 mm).

Key Features

  • 3 safety outputs (NO), 1 auxiliary output (NC)

  • Safe up to PL e / SIL CL3

  • Single or dual‑channel operation

  • Cross‑circuit detection for dual‑channel wiring

  • Monitored manual or automatic reset

  • LED status indicators for quick diagnostics

  • Force‑guided contacts (EN 50205)

  • Removable screw‑type terminals


Safety Functions

The 3SK2122-1AA10 is used to monitor safety devices such as emergency stop buttons, interlocking gates, and safety mats. In dual‑channel mode with cross‑circuit detection, it can detect short circuits between the two input channels or between a channel and 24V/GND. If a fault is detected or the safety device opens, the relay drops out immediately and disconnects the load. The monitored reset ensures that the reset button is released before the relay can re‑energize.

Configuration and Wiring

The relay is configured via DIP switches on the front. Switch 1 selects operating mode: S1 = OFF for single channel, ON for dual channel. Switch 2 selects reset type: OFF for automatic reset, ON for monitored manual reset (requires a feedback loop from the contactor’s auxiliary contacts). Inputs are connected to terminals S11/S12 and S21/S22. The safety outputs (13-14, 23-24, 33-34) are connected in series with the contactor coils. The auxiliary NC (41-42) can be used for PLC monitoring. For dual‑channel operation with cross‑circuit detection, use separate cable cores for each channel; do not share a common return wire.

Installation

Mount the relay on a 35 mm DIN rail. Connect 24 V DC to terminals A1 (+) and A2 (-). Ensure the power supply has sufficient current capacity (≥ 100 mA). The relay is not isolated between inputs and outputs; maintain proper separation from high‑voltage circuits. The terminals accept wire sizes 0.2‑2.5 mm². After wiring, set the DIP switches before powering up. Test the safety function by activating the emergency stop and verifying that all safety outputs de‑energize.

Applications

Typical applications include:

  • Emergency stop monitoring on machine tools, conveyors, and packaging machinery

  • Safety gate interlocking (with hinge or magnetic switches)

  • Two‑hand control systems (with simultaneous monitoring)

  • Light curtain evaluation (if the light curtain has OSSD outputs, a safety relay may be needed to interface)

Diagnostics and Maintenance

LED indicators: PWR (green) – supply OK; IN1 (yellow) – input channel 1 closed; IN2 (yellow) – input channel 2 closed; OUT (green) – safety outputs energized. If OUT is off but IN1/IN2 are on, check the reset circuit. If IN1 and IN2 have different states for more than 0.5 seconds, the relay detects a discrepancy and enters a fault condition (OUT off). To reset after a fault, remove the power for 10 seconds. The relay requires no periodic maintenance but should be tested annually by performing a function test of the connected safety device.

Standards and Certifications

The 3SK2122-1AA10 is CE, UL, and TÜV certified. It meets EN ISO 13849‑1 (Cat. 4, PL e), IEC 61508 (SIL3), and IEC 62061 (SIL CL3). It is RoHS compliant.

Conclusion

The Siemens 3SK2122-1AA10 safety relay offers a compact, highly reliable solution for common machine safety applications. Its flexible configuration, high safety integrity, and diagnostic LEDs make it a solid choice for machine builders and safety system integrators.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Deployment and Performance Optimization of ADLINK MXC-6400 Industrial Control Computer
  • Selection and Deployment of ADLINK Matrix Series Industrial Control Computers
  • российские промышленные новые машины.Наш отдел дебютировал в 2026 году в России Международная промышленная ярмарка INNOPROM
  • Deeply cultivating the Eurasian industrial market, linking new industrial opportunities between China and Russia
  • Deployment and troubleshooting of ADLINK GIE64+PoE acquisition card
  • Honeywell UMS Security System Troubleshooting Guide
  • Honeywell Expert Series C I/O Troubleshooting Guide
  • ADLINK EOS-1200 Vision System Deployment and Troubleshooting
  • ADLINK DLAP-5200 series AI engine deployment and optimization
  • ADLINK DLAP-4000 Deployment and BIOS Optimization
  • ADLINK Matrix MXC-2000 Deployment and Troubleshooting
  • ADLINK DAQe-2000 series acquisition card calibration and synchronization
  • ADLINK cPCI-6520 Core i7 Processor Blade Engineering Application Guide
  • ADLINK CM1-86DX3 PC/104 Embedded Single Board Computer Engineering Application Guide
  • Honeywell DC1000 Series PID Temperature Controller Engineering Application Guide
  • ALSTOM MiCOM C264 Substation Controller Engineering Application Guide
  • EMERSON AMS 2140 Practical Guide for On site Dynamic Balance and Vibration Analysis
  • ADLINK NuPRO-E320 motherboard deployment and tuning guide
  • ADLINK NuPRO-800 Dual PIII Industrial SBC Maintenance and Upgrade Guide
  • ADLINK NuPRO-598 SBC Maintenance Practical Guide
  • ADLINK MXC-6300 Fanless Embedded Industrial Control Computer Deployment Guide
  • ADLINK Express-BASE7 Carrier Board Quick Deployment and Debugging Guide
  • ADLINK DLAP-211 Edge AI Platform Selection and Deployment Guide
  • ADLINK 7230 Series Isolation DIO Card Selection and Engineering Application Guide
  • ADLINK cPCI-6965 SBC Embedded Installation and BIOS Tuning Guide
  • ADLINK 7200 Series High Speed DIO Card Practical Guide
  • ADLINK DLAP Series Edge AI Acceleration Platform Selection and Deployment Practical Guide
  • DEIF TCM-2 thyristor control module: Wind power cut in control engineering guide
  • DEIF MVR-200 Medium Voltage Relay: Installation and Wiring Engineering Guide
  • DEIF MDR-2 Differential Relay: Engineering Guide for Generator Differential Protection
  • DEIF Delomatic 3 AOM: Engineering Guide for Analog Output Modules
  • DEIF AGI 400 Graphic Interface: Ship and Industrial HMI Solution
  • DEIF BRW-1 Marine Instruments: Installation and Calibration Guide for Offshore Bridge Indicators
  • DEIF AGC 200 Controller: Quick Deployment and Configuration Guide for Generator Sets
  • DEIF AGC-2 Controller: The Ultimate Guide to Automatic Control and Protection of Generator Sets
  • ABB SPA-ZC400 Gateway: REM54x Access to IEC 61850 Ultimate Engineering Guide
  • ABB REM 543/545 Terminal
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module
  • Beckwith M-3520 Interconnection Protection Relay
  • Beckwith M-3430 Generator Protection Relay
  • Beckwith M-2293B adapter panel replacement GE regulator guide
  • Selection and Networking of Beckwith M-2001C Digital Voltage Regulating Controller
  • Beckwith M-2001B Digital Voltage Regulating Controller
  • Beckwith M-0388/M-0389 Synchronous Inspection Relay Application Guide
  • Beckwith M-0193B Synchronizer Debugging and System Integration Guide
  • Beckwith M-0115A Parallel Balance Module Debugging Guide
  • Beckwith M-0067E On Load Voltage Regulating Controller Selection and Debugging Guide
  • Debugging and Fault Handling of Beckwith M-4272 Digital Busbar Conversion System
  • Beckwith M-3311A Transformer Protection Relay Debugging Guide
  • Beckwith M-3425A Generator Protection Relay Debugging Guide
  • Setting and troubleshooting of Basler BE1-27/59 voltage relay
  • Debugging and troubleshooting of Basler AVC63-12/AVC125-10 voltage regulator
  • Basler L301kc Line Array Camera Technology and Troubleshooting
  • Selection and Debugging of Basler CBS 212A Current Boosting System
  • Selection and commissioning of Basler BE3-25 synchronous inspection relay
  • Basler BE1-32R/32O/U Direction Power Relay Setting and Testing Guide
  • Basler PRS 250 Synchronous Relay Maintenance and Replacement Guide
  • Basler piA2400-17gc Industrial Camera Replacement and Optimization Guide
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection
  • Basler SSR Static Voltage Regulator: A Complete Guide to Debugging and Troubleshooting
  • Basler SR4A/SR8A Voltage Regulator: Detailed Debugging and Troubleshooting Explanation
  • Basler BE2000E Voltage Regulator: Replacement and Application Details
  • Basler DECS-2100 Excitation System: Modular Upgrade and Engineering Application
  • Basler BE1-851 Overcurrent Protection System: A Complete Guide to Professional Debugging and Troubleshooting
  • Basler APR 63-5 Voltage Regulator: Professional Debugging and Troubleshooting Guide for Industrial Generator Excitation Systems
  • Basler BE1-FLEX Protection System: A Complete Guide to Professional Installation, Configuration, and Troubleshooting
  • Debugging and Testing of Basler BE1-700 Relay
  • Basler BE1-87B busbar differential setting test
  • Basler BE1-40Q demagnetization relay setting test
  • Basler BE1-60 Voltage Balance Relay Setting Test
  • Basler BE1-47N Relay Field Setting and Testing Guide
  • Basler BE1-81O/U Frequency Relay: On site Debugging and Protection Configuration Guide
  • Basler BE1-11f Feedline Protection System Debugging and Troubleshooting Guide
  • Basler DECS-250 Excitation System: Installation, Configuration, and Troubleshooting Practice Guide
  • Basler DECS-100 Digital Excitation System Debugging Guide
  • Application Guide for Basler BE1-BPR Circuit Breaker Protection Relay
  • Basler BE1-50/51B-255 Replacement CO Relay Guide
  • Basler BE1-25 synchronous inspection relay principle and testing
  • Basler BE1-51 Time Overcurrent Relay Debugging Guide
  • Practical Guide to Basler DECS-300 Digital Excitation System
  • Mitsubishi FX Series PLC Data Communication Practical Manual
  • Selection of Hirschmann cSCALE S6/C8 Mobile Safety Controller
  • Hirschmann OZD Profi G12D repeater explosion-proof installation configuration
  • Hirschmann OCTOPUS OS20/24 Switch Installation Power Supply
  • Hirschmann RS20/30/40 Switch Selection and PoE Deployment
  • Hirschmann EAGLE One Firewall Installation and Configuration Guide
  • Hirschmann MACH102 Switch Installation and Power Supply Guide
  • Hirschmann MICE MS20/MS30 Installation and DIP Configuration
  • Hirschmann BOBCAT BRS Switch Installation and Power Supply Guide
  • Hirschmann RSB20 Switch Deployment and Redundant Configuration
  • Hirschmann RS20 Basic Switch Installation and Debugging Guide
  • BECKHOFF EP20xx/EP28xx Output Module Installation and Debugging Guide
  • BECKHOFF EL5102 Encoder Terminal Debugging and Troubleshooting
  • BECKHOFF CU8803 Launch Box Installation and Explosion proof Guide
  • BECKHOFF CU20xx/CU22xx Switch Installation and Troubleshooting
  • BECKHOFF AMP8000 Servo Drive Installation and Debugging Manual
  • BECKHOFF EL2911 Safety Feed Terminal Debugging Guide
  • BECKHOFF EL600x/EL602x Serial Port Module Debugging Manual
  • BECKHOFF CP6700 Panel PC Installation and Maintenance Manual
  • BECKHOFF CP70xx panel maintenance and troubleshooting
  • BECKHOFF CP29xx Panel Installation and Troubleshooting
  • Beckhoff C6650-0060 Industrial Control Computer Hardware Architecture and RAID Data Security
  • Beckhoff BK1120/BK1250 EtherCAT Coupling Debugging and KL Terminal Parameterization Complete Guide
  • Beckhoff CX20x0 Embedded Controller Hardware Maintenance and Troubleshooting Complete Manual