Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • Siemens 6ES7136-6BA00-0CA0 PLC Module ET 200SP
    ❤ Add to collection
  • Siemens 6ES7136-6BA00-0CA0 PLC Module ET 200SP

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥21763.00
      ¥22631.00
      ¥21763.00
      ¥21763.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:1.450KG
    • Quantity:
    • (Inventory: 3467)
Description
<span style="font-size: 18px; font-family: arial;">Siemens 6ES7136-6BA00-0CA0 PLC Module ET 200SP</span>

Siemens 6ES7136-6BA00-0CA0 ET 200SP Safety Input Module

The Siemens 6ES7136-6BA00-0CA0 is a fail-safe digital input module for the ET 200SP distributed I/O system. Designated as F-DI 8x24VDC HF (High Feature), this module provides 8 channels for 24V DC safety-related inputs. It is certified for use in safety applications up to SIL3 according to IEC 61508 and PL e according to ISO 13849-1. The module integrates seamlessly with SIMATIC S7-1200, S7-1500, and other F-CPUs via PROFIsafe.

Technical Specifications

The module has 8 fail-safe digital inputs, each channel can be configured as a single channel (1oo1) with test pulses or dual channel (1oo2) equivalent. Input voltage range is 19.2V to 28.8V (type 3). Input delay adjustable from 0.1 ms to 20 ms. The module provides parameterizable short-circuit and cross-circuit detection. Diagnostic alarms include channel fault, wire break (for current sourcing sensors), and sensor supply voltage monitoring. The module includes an internal sensor supply (24V DC, up to 200 mA per group) for powering proximity sensors or safety switches.

Rated supply voltage (L+) is 24V DC (20.4-28.8V) via the ET 200SP backplane. Power consumption from the backplane is 22.5 mA. The module width is 15 mm (standard for ET 200SP). Operating temperature range is -30°C to +60°C. Protection rating IP20.

Key Features

  • 8 fail-safe digital inputs, 24V DC

  • High Feature (HF) with extended diagnostics

  • PROFIsafe communication (F-destination address configurable)

  • Parameterizable input delay and sensor supply monitoring

  • Single or dual channel configuration per sensor

  • Up to SIL3 / PL e safety level

  • Built-in sensor supply (24V DC)

  • Short-circuit and cross-circuit detection

  • Red or black plastic housing (fail-safe identification)

  • Compatible with ET 200SP base units Type A0 to A3

Safety Functions

The F-DI module supports all standard safety functions including emergency stop, safety door monitoring, light curtain/barrier evaluation, two-hand control, and enable switches. Each input channel can be assigned to a safety program in the F-CPU. The module performs self-tests and cross-checks. It also supports the use of OSSD outputs (e.g., from light curtains) by interpreting the pulse signal. The passivation and re-integration behavior is configurable.

Integration with ET 200SP

The module mounts on an ET 200SP base unit (e.g., 6ES7193-6BP00-0DA0) and communicates via the backplane bus to the interface module (IM155-6) or directly to a CPU with integrated ET 200SP. PROFIsafe frames are exchanged with the F-CPU over PROFINET or PROFIBUS. Configuration is performed in TIA Portal using the Safety Administration tool. The F-destination address is set via software, not via DIP switches. The module supports firmware updates via the online interface.

Applications

Typical safety applications include machine guarding (safety interlock switches, emergency stop pushbuttons, safety mats), press monitoring, robot cell access control, and conveyor protection. The module is suitable for use in automotive assembly lines, packaging machinery, and material handling systems requiring safety integrity up to SIL3. The ability to connect standard sensors (with test pulse evaluation) and safety-rated devices reduces component variety.


Environmental and Certifications

The 6ES7136-6BA00-0CA0 is certified by TÜV, UL, and CSA for functional safety. It meets CE, UKCA, EAC, and KC standards. Ambient temperature (horizontal mounting) -30°C to +60°C; vertical mounting up to 50°C. Humidity 10-95% non-condensing. Vibration resistance according to IEC 60068-2-6 (2g). The module is rated for pollution degree 2 and overvoltage category II.

Wiring and Installation

Wiring is via the ET 200SP push-in terminal blocks (standard 24V DC sensors connect to inputs X1 to X8). The base unit provides a 24V sensor supply output. Shield connection possible via shield contact plate. The F-DI module must be placed adjacent to a failsafe terminal module (not required for this module as it uses standard base unit). The color of the housing (red) indicates safety component. F-destination address is set via TIA Portal.

Conclusion

The Siemens 6ES7136-6BA00-0CA0 ET 200SP safety input module offers a compact, flexible solution for fail-safe digital signal acquisition. With high diagnostic capability, PROFIsafe integration, and support for up to SIL3/PL e, it is a reliable choice for safety applications in distributed automation systems.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Key Points for Selection and Deployment of MITSUBISHI FX3GE PLC
  • Beckhoff EP23xx EtherCAT Box Selection Troubleshooting
  • MITSUBISHI MDS-B servo troubleshooting
  • TOYO valve pressure and temperature selection
  • SIEMENS SIMODRIVE 611 HR/HRS Replacement and Advanced Positioning Techniques
  • SIEMENS SINUMERIK 840C 611-D Startup and Troubleshooting Guide
  • FANUC Series 0i-F Maintenance and Troubleshooting
  • Troubleshooting Schneider Modicon TM3 Bus Expansion
  • Troubleshooting of R&S EPL1000
  • Baum ü llerb b maXX 5000 Safety Configuration and Troubleshooting Guide
  • Huichuan AM600 Motion Controller Malfunction and Replacement Guide
  • Allen Bradley Ultra3000 Servo Motor Replacement Guide
  • NEC NL8060BC26-17 LCD Module Maintenance and Replacement
  • ABB Pluto Safety PLC Maintenance and Troubleshooting
  • OMRON NE1A Safety Controller Troubleshooting and Replacement
  • Allen Bradley 2711P series PanelView Plus human-machine interface terminal
  • NI cFP-22xx on-site integration and troubleshooting
  • KEYENCE XG-8000 Line Scan Visual Debugging Guide
  • OMRON G9SX Security Unit Configuration and Troubleshooting
  • OMRON CPM1A Maintenance and Troubleshooting
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide