Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • Bonfiglioli A 10 2 UH25 P71 Gearmotor
    ❤ Add to collection
  • Bonfiglioli A 10 2 UH25 P71 Gearmotor

    • ¥31363.00
      ¥32785.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.150KG
    • Quantity:
    • (Inventory: 29)
Description
<span style="font-size: 18px; font-family: arial;">Bonfiglioli A 10 2 UH25 P71 Gearmotor</span>

Bonfiglioli A 10 2 UH25 P71 Gearmotor

Product Overview

The Bonfiglioli A 10 2 UH25 P71 is an industrial gearmotor that combines a BN71A4 0.75 kW motor with a gear transmission for speed reduction and torque increase. The code ME52G0580000 identifies the specific unit configuration. The gearmotor is intended for professional integration into industrial machinery where a compact motor and gearbox arrangement is required. Correct selection depends on output torque, speed, duty cycle, mounting position, and environment.

The gearmotor can be used in conveyors, processing equipment, material handling, and general machinery. Installation and maintenance should follow technical documentation so that alignment, lubrication, and electrical connections are correct. The unit forms part of a complete drive system that includes the control panel, protective devices, transmission, and driven machine. The nameplate data should be checked before connection.

Construction and Mechanical Design

The gearmotor contains an electric motor, a gear housing, gear stages, shafts, bearings, and sealing elements. The motor provides input power, and the gear stages reduce speed and increase torque. The housing supports the bearing arrangement and protects internal parts from contamination. Seals retain lubricant and reduce the entry of dust and moisture. The mounting interface and output shaft must match the machine structure and driven equipment.

Installation requires a clean, flat, and rigid mounting surface. The unit should seat without distortion. Fasteners must be tightened to the specified torque and checked after initial operation. Shaft connections should be aligned carefully. Couplings, pulleys, and other transmission elements must be fitted with suitable tools and without impact. Excessive overhung load or belt tension can affect bearing life.

Electrical Connection and Commissioning

The motor nameplate provides voltage, current, frequency, power, speed, and connection details. The supply and control system must match these values. Star or delta connection must be correct for the available voltage. Protective earth must be connected. The terminal box wiring should be secure and protected from strain. Cable glands should maintain the enclosure protection. Insulation resistance should be checked before first operation where required.

Commissioning should include a no-load run where possible. Rotation direction, noise, vibration, and current should be checked. Fasteners should be rechecked after initial operation. The lubricant level should be confirmed according to the mounting position. If the unit is controlled by an inverter, drive settings and ramps should match the motor and load. Full process load should be applied only after checks are complete.

Operation and Monitoring

During operation, the gearmotor should run smoothly within the designed speed and torque range. Operators should monitor current, temperature, noise, vibration, and leakage. Excessive current can indicate overload or mechanical binding. High temperature can result from poor cooling, overload, or incorrect supply. Leakage can lead to insufficient lubrication and should be corrected promptly. The exterior should be kept clean.

Load changes can affect gearmotor life. Increased throughput, higher torque, frequent starting, frequent reversing, or shock loading should be reviewed against the original selection. The unit should not be operated beyond its rated conditions. If the machine process changes, the drive train should be checked. Protective devices should remain active.

Protection and Reliability

Reliability depends on correct electrical protection, alignment, lubrication, and protection from contamination. Overload protection should be set according to the motor current. Short circuit protection must be provided by the installation. The unit should be protected from water, dust, and corrosive atmosphere beyond its rating. Excessive vibration and misalignment should be corrected. Fasteners should be checked periodically.

Overload protection should be coordinated with the machine design. Jam conditions, blocked loads, and sudden torque peaks can stress gears and bearings. Mechanical overload protection, torque limits, or current protection should be set according to the drive train. Service work should be performed by qualified personnel. Opening the unit without proper instructions can affect sealing and bearing adjustment.


Maintenance and Service

Maintenance should include periodic inspection of lubricant, seals, fasteners, terminals, cooling, and running conditions. The interval depends on operating hours, load, temperature, and environment. Dust and dirt should be removed from the motor frame and gear housing. Cable glands and terminal connections should be checked. Bearing noise should be monitored. Lubricant changes, if required, should use the specified type and quantity.

Before service, the machine must be isolated and secured against rotation. The unit should be allowed to cool where necessary. Cables should be labeled before disconnection. Replacement of seals or bearings requires proper tools and clean conditions. After service, alignment, electrical connections, and lubricant level should be checked. The unit should be run briefly before return to full duty.

Integration and Selection Summary

The A 10 2 UH25 P71 gearmotor can be integrated into industrial machines that require a compact motor and gear drive arrangement. The final application determines protection, mounting position, control method, and maintenance access. The unit should be selected as part of the complete drive train, including control panel, protective devices, transmission, and driven machine.

Selection should confirm the model A 10 2 UH25 P71, BN71A4 motor, 0.75 kW rating, code ME52G0580000, ratio, torque capacity, mounting position, and lubrication requirements. The designer should verify compatibility with the supply and driven machine. Documentation should be reviewed before installation.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller
  • DATA PATTERNS DP-VME-5114 Dual PMC Carrier Board Integration and Troubleshooting
  • CMZ SVM1608 Intelligent Servo Driver
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide
  • SUMITOMO ELECTRIC AC1135U Small Parts Turning Application Guide
  • SUMITOMO ELECTRIC AC1030U Precision Machining Selection and Practice for Small Parts
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection
  • BENDER RCMA475LY Residual Current Monitoring
  • BENDER IRDH575 Insulation Monitoring
  • BENDER IRDH265 Insulation Monitoring and Debugging
  • Bender RCMA475LY residual current monitor debugging
  • Beckwith Electric M-3425A Generator Protection Relay Debugging Guide
  • Automated MEX816U Expander Troubleshooting Guide
  • ASEM HT2150 Industrial Tablet Selection and Troubleshooting
  • Troubleshooting and practical application of Advantest U3771/3772 microwave spectrum analyzer
  • Advantest R6144 Programmable DC Voltage/Current Source (Calibration Source) Calibration and Maintenance
  • Aerotech UNIDEX 100/U100i single axis motion controller
  • Aerotech Ndrive MP Ultra Compact PWM Digital Servo Driver
  • Aerotech Ndrive HPe 10/20/30 High Performance PWM Digital Servo Drive
  • Aerotech Ndrive HLe maintenance replacement
  • Aerotech Ndrive CP maintenance replacement
  • Aerotech Ndrive Linear Drive Selection
  • Aerotech NDrive HL linear drive maintenance replacement
  • Aerotech NDrive HP 10/20/30 Maintenance and Replacement
  • Aerotech NDrive CP10 Servo Drive Guide
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide