Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • Bonfiglioli C312 P P90 Speed Reducer
    ❤ Add to collection
  • Bonfiglioli C312 P P90 Speed Reducer

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥23157.00
      ¥25352.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.400KG
    • Quantity:
    • (Inventory: 64)
Description
<span style="font-size: 18px; font-family: arial;">Bonfiglioli C312 P P90 Speed Reducer</span>

Bonfiglioli C312 P P90 Speed Reducer with 1/490.720.0-S Clutch

The Bonfiglioli C312 P P90 speed reducer with 1/490.720.0-S clutch is a right angle gearbox configured with a P90 input flange and an integrated clutch. The C312 size belongs to the Bonfiglioli C series of gear reducers used in industrial power transmission. The bevel or helical gear design provides efficient torque transfer at a right angle, making the unit suitable for conveyors, mixers, and general industrial machinery. The clutch identified by 1/490.720.0-S adds a mechanical interface for the drive train.

Product Overview

The C series includes gear reducers designed for industrial duty with robust housings and precise gear manufacturing. The C312 size is a mid sized unit suitable for moderate to high torque requirements. The P90 input flange allows a matching motor or drive component to be mounted to the gearbox. The integrated clutch provides a defined interface between the gearbox and the adjacent drive element. The exact clutch function and settings should be confirmed with the product documentation.

The gearbox housing is designed for rigidity so that the gear mesh remains stable under load. Bearings support the input and output shafts and are selected for the expected radial and axial forces. Lubrication is contained within the housing and distributed to the gears and bearings during operation. Seals protect the internal components from dust and moisture. The compact design makes the unit suitable for integration into industrial machines.

Construction and Design

The gear stages are manufactured to precise tolerances to provide smooth rotation and efficient torque transfer. The housing supports the shafts and bearings with high stiffness. The P90 input flange is machined for precise mounting. The clutch interface identified by 1/490.720.0-S is integrated into the drive arrangement. The output shaft is machined to accept couplings, pulleys, sprockets, or other driven components.

Correct alignment between the motor, gearbox, clutch, and driven equipment is important for efficient power transmission and long bearing life. The housing design supports heat dissipation and structural strength. Lubrication and sealing protect the internal components during operation. The unit should be selected with an appropriate service factor for the application.

Performance Characteristics

The C312 speed reducer provides efficient right angle power transmission across a range of input speeds. The gear design determines the reduction ratio, output speed, and torque multiplication. The P90 input flange allows the gearbox to be paired with a matching motor or drive component. The integrated clutch provides a mechanical connection that can be specified for the application requirements.

The gearbox should be selected with an appropriate service factor for the duty cycle. Starting loads, shock loads, and continuous operation affect the mechanical and thermal capacity of the unit. Lubrication condition and operating temperature should be monitored. Correct installation and maintenance help maintain stable performance and long service life.


Applications

The Bonfiglioli C312 P P90 speed reducer is suitable for belt conveyors, screw conveyors, mixers, agitators, packaging machines, and general industrial drives. The right angle layout is useful when the motor must be positioned at 90 degrees to the driven shaft. The integrated clutch interface can be useful in drive trains that require a defined mechanical connection between components.

The P90 input flange supports mounting of a matching motor or drive component. The gearbox can be paired with standard three phase motors or other drive elements that match the interface. When variable speed operation is required, the motor and gearbox should be evaluated together. Correct selection helps ensure reliable operation and long service life.

Installation Guidelines

Installation should begin with a check of the nameplate data and a visual inspection of the gearbox and clutch. The unit should be mounted on a rigid base that can withstand the torque reaction. Mounting bolts should be tightened to the recommended torque. The motor or drive component should be aligned with the P90 flange so that the shaft connection engages correctly. The clutch interface should be assembled according to the product documentation.

The output shaft should be aligned with the driven equipment to avoid excessive loads on bearings and seals. After installation, the gearbox should be checked for smooth rotation and correct oil level. A short run without load helps confirm that the assembly operates correctly. Any unusual noise, vibration, or temperature rise should be investigated before full service. Electrical connections should be made by qualified personnel following local regulations.

Maintenance Recommendations

Regular maintenance supports reliable performance and long service life. Oil level and oil condition should be checked at recommended intervals. The first oil change should be performed after the initial running in period, and later changes should follow the schedule for the operating conditions. Seals and bearings should be inspected periodically. The clutch should be checked according to the product documentation. Leakage, abnormal noise, or vibration should be addressed promptly.

The exterior of the gearbox should be kept clean to support heat dissipation. Adequate airflow around the housing helps maintain stable temperatures. In dusty or humid environments, additional protection may be needed. Maintenance records help identify trends and support planned servicing. Following a consistent maintenance schedule reduces the risk of unexpected downtime.

Selection Considerations

When selecting the C312 P P90 speed reducer with clutch, engineers should confirm the required output torque, output speed, duty cycle, and environmental conditions. The ratio and motor speed determine the output speed. The available torque depends on motor power and gearbox efficiency. A service factor should be applied for starting loads, shock loads, and continuous operation. The P90 flange and clutch interface must match the motor and driven equipment.

The gearbox mounting position should provide adequate support and allow correct lubrication. The output shaft and mounting features should match the driven equipment. The clutch requirements should be evaluated against the drive train design. Correct selection helps ensure smooth operation, stable thermal behavior, and long service life.

Conclusion

The Bonfiglioli C312 P P90 speed reducer with 1/490.720.0-S clutch offers a right angle reduction solution with a P90 input flange and integrated clutch interface. Its construction supports efficient torque transmission and stable operation in conveyors, mixers, and industrial machinery. With correct installation and maintenance, the gearbox provides dependable performance and long service life.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Woodward CPC-II electro-hydraulic current pressure converter
  • UniOP ePALM10 Handheld HMI
  • TMEIC TMdrive-30 frequency converter
  • TEWS TVME200 Carrier Board Configuration and Troubleshooting Guide
  • TDK Alpha 400 Power Troubleshooting Guide
  • STUCKE SYMAP relay
  • Deployment and troubleshooting of Softing CAN-AC2-PCI interface card
  • Installation, Maintenance, and Troubleshooting of Siemens C7-623/624
  • Foxboro Compact 200 Series 16 Slot Bottom Plate Deployment and Maintenance Guide
  • Foxboro 84F/84W Vortex Flow Meter Selection and Debugging Guide
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller
  • DATA PATTERNS DP-VME-5114 Dual PMC Carrier Board Integration and Troubleshooting
  • CMZ SVM1608 Intelligent Servo Driver
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide
  • SUMITOMO ELECTRIC AC1135U Small Parts Turning Application Guide
  • SUMITOMO ELECTRIC AC1030U Precision Machining Selection and Practice for Small Parts
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection
  • BENDER RCMA475LY Residual Current Monitoring
  • BENDER IRDH575 Insulation Monitoring
  • BENDER IRDH265 Insulation Monitoring and Debugging
  • Bender RCMA475LY residual current monitor debugging
  • Beckwith Electric M-3425A Generator Protection Relay Debugging Guide
  • Automated MEX816U Expander Troubleshooting Guide
  • ASEM HT2150 Industrial Tablet Selection and Troubleshooting
  • Troubleshooting and practical application of Advantest U3771/3772 microwave spectrum analyzer
  • Advantest R6144 Programmable DC Voltage/Current Source (Calibration Source) Calibration and Maintenance
  • Aerotech UNIDEX 100/U100i single axis motion controller
  • Aerotech Ndrive MP Ultra Compact PWM Digital Servo Driver
  • Aerotech Ndrive HPe 10/20/30 High Performance PWM Digital Servo Drive
  • Aerotech Ndrive HLe maintenance replacement
  • Aerotech Ndrive CP maintenance replacement
  • Aerotech Ndrive Linear Drive Selection
  • Aerotech NDrive HL linear drive maintenance replacement
  • Aerotech NDrive HP 10/20/30 Maintenance and Replacement
  • Aerotech NDrive CP10 Servo Drive Guide
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot