Bonfiglioli Fuji GVX2000-11-TSL2 Inverter
Product Overview
The Bonfiglioli Fuji GVX2000-11-TSL2 is an industrial inverter and variable speed drive rated at 11 kW and 14.75 HP. It is designed to control the speed and torque of three-phase motors in machinery where fixed-speed operation is not suitable. The drive converts the supply into a variable voltage and frequency output so that the motor can follow process demand. The model designation identifies the power rating, configuration, and application class. The drive should be selected according to motor current, load type, duty cycle, and environmental conditions.
The inverter is suitable for pumps, fans, conveyors, mixers, and general industrial equipment. Correct installation and commissioning are important for stable operation. The device should be installed by qualified personnel who understand electrical safety, electromagnetic compatibility, and motor control. The cabinet and wiring must support cooling, protection, and service access. The drive forms part of a complete system that includes the motor, cables, protective devices, and controller.
Construction and Electrical Design
The inverter contains a power section, a control section, and a user interface. The power section rectifies the supply, stores energy in the direct current link, and switches the output to create a variable frequency waveform. The control section processes references, digital and analog inputs, and protection logic. The keypad and display provide access to parameters and status. Power terminals, motor terminals, and control terminals must be wired according to the documentation.
Cooling clearance must be respected. The inverter should be mounted on a rigid surface with adequate air flow. Power and control cables should be separated. Shielding and grounding are important for electromagnetic compatibility. Protective devices such as fuses or circuit breakers must be selected correctly. Motor cables should be suitable for inverter operation. The installation should prevent dust, moisture, and conductive contamination from entering the drive.
Installation and Commissioning
Installation begins with checking the supply, motor, and environmental conditions. The inverter should be mounted with sufficient clearance. Power cables should be connected with correct phase sequence and grounding. Control cables should be shielded where required. Emergency stop and safety functions must be implemented through the machine safety system. The motor should be protected by suitable overload settings. The cabinet should provide adequate cooling and protection.
Commissioning should start with parameter setup and motor data. Rotation direction should be checked without load where possible. Analog scaling, digital input functions, ramp times, and fault responses should be configured. The drive should be tested at low speed and then under load. Parameters should be saved. A commissioning record should include motor data, control settings, and option configuration.
Operation and Monitoring
During operation, the keypad and display provide status and fault information. The drive can be controlled locally or remotely. Operators should monitor motor current, speed, and temperature. Abnormal vibration, noise, or overheating should be investigated. The inverter should be kept clean and the cabinet filters should be maintained. Fault codes should be recorded before reset.
Operating limits should protect the motor and machine. Current limits, torque limits, and ramps should match the load. If the process changes, the settings should be reviewed. The braking function, if used, must be coordinated with braking resistors or braking units. The direct current link and braking system should be protected from overvoltage during rapid deceleration.
Protection and Reliability
The inverter includes protection functions for overcurrent, overvoltage, undervoltage, motor overload, drive overtemperature, and other abnormal conditions. These functions help reduce risk but do not replace correct system design. Fault causes should be identified before reset. Repeated faults can indicate wiring errors, incorrect parameters, overload, or cooling problems. The drive should be protected from conductive dust and moisture.
Reliability depends on proper grounding, shielding, cooling, and cable selection. Long motor cables can require filters or reactors. Harmonic distortion should be considered in the supply system. Line reactors may be used to reduce supply disturbances. The motor insulation should be suitable for inverter operation. Bearing currents should be reviewed for long cable runs or high switching frequencies.
Maintenance and Service
Maintenance should include periodic inspection of cooling, terminals, fans, and enclosure filters. Dust should be removed without forcing contamination into the drive. Power terminals should be checked for tightness after isolation and proof of safe condition. The direct current link must be allowed to discharge before service. Parameter backups should be kept. If the drive has been stored for a long period, capacitor conditioning may be required according to technical instructions.
Service work should be performed by qualified personnel. Replacement drives should be configured to match the machine. The motor data and control settings should be verified. The safety system should be tested after service. Records of faults and maintenance help identify recurring issues. The drive should not be opened unless the required safety procedures are followed.
Integration and Selection Summary
The GVX2000-11-TSL2 inverter can be integrated into industrial machines that require adjustable motor speed. It is suitable for pumps, fans, conveyors, mixers, and general processing equipment. The final application determines the required control mode, braking, communication, and protection. The inverter should be selected as part of the complete drive system, including motor, cables, cabinet, and controller.
Selection should confirm the model GVX2000-11-TSL2, 11 kW rating, supply voltage, motor current, load type, duty cycle, ambient conditions, and required options. The designer should verify whether braking, communication, filters, or reactors are needed. Documentation should be reviewed before installation. Any special environment or duty cycle should be considered.