Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • Mitsubishi GT2310-VTBA GT2310-VTBD HMI Touch Screen 10.4 Inch
    ❤ Add to collection
  • Mitsubishi GT2310-VTBA GT2310-VTBD HMI Touch Screen 10.4 Inch

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥34626.00
      ¥36463.00
      ¥34626.00
      ¥34626.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:1.340KG
    • Quantity:
    • (Inventory: 5174)
Description
<span style="font-family: arial; font-size: 18px;">Mitsubishi GT2310-VTBA GT2310-VTBD HMI Touch Screen 10.4 Inch</span>

Mitsubishi GT2310 Series HMI Touch Screen

The Mitsubishi GT2310-VTBA and GT2310-VTBD are 10.4-inch graphic operation panels belonging to the GOT2000 family. These HMI touch screens provide a large VGA display with analog resistive touch technology, offering clear visualization and reliable input for complex industrial applications. The VTBA model is powered by AC (100-240V), while the VTBD model operates on 24V DC, allowing selection based on available control cabinet power.

Display Specifications

The 10.4-inch TFT LCD displays 65,536 colors with a resolution of 640x480 pixels (VGA). Brightness is rated at 350 cd/m² with LED backlight life of 50,000 hours typical. Contrast ratio is 500:1. Viewing angles are 80° horizontal and 60° vertical. The analog resistive touch panel is durable and supports gloved operation. The front panel meets IP65 protection rating, resistant to dust and low-pressure water jets. The LED backlight includes a dimming function to extend service life.

Key Features

  • 10.4-inch TFT color LCD, 640x480 VGA resolution

  • Analog resistive touch panel

  • AC power (GT2310-VTBA) or DC 24V (GT2310-VTBD)

  • Ethernet 10/100Base-T for network connectivity

  • RS232 and RS422/485 communication ports

  • USB mini-B for programming

  • USB host port for data storage (Type A)

  • SD card slot for logging and recipe storage

  • Built-in real-time clock and buzzer

  • IP65 front panel protection


Communication Capabilities

The GT2310 series provides versatile connectivity for industrial networks. The Ethernet port supports MELSEC communication protocols, Modbus TCP, and web server functions for remote monitoring. The RS232 port connects to programming devices, barcode scanners, or serial printers. The RS422/485 port enables multi-drop connections to Mitsubishi PLCs, inverters, temperature controllers, and third-party devices using Modbus RTU or other protocols. The USB host port allows connection of USB memory drives for data logging, screen capture, and project transfers. The SD card slot provides additional non-volatile storage for recipes, alarms, and trends.

Programming and Software

Screen design is performed with GT Designer3 (GOT2000 series) software. The software offers a comprehensive object library including pushbuttons, lamps, numeric displays, trend graphs, and alarm lists. Advanced features include recipe management, multi-language support (up to 32 languages), script programming, and data logging to CSV format. The built- in web server enables remote operation and diagnostics via standard web browsers. The software also supports simulation mode for offline debugging.

Applications

The 10.4-inch size makes the GT2310 series suitable for applications requiring detailed graphical displays such as CNC machine controls, packaging lines, process monitoring systems, material handling equipment, and building automation. The large screen area accommodates complex layouts with multiple gauges, buttons, and status indicators. The IP65 rating allows placement in wash-down areas of food and beverage facilities.

Environmental and Installation

Operating temperature: 0 to 55°C (horizontal mounting) or 0 to 45°C (vertical). Storage: -20 to 60°C. Humidity: 10-90% RH non-condensing. Vibration resistance: 2g at 10-25 Hz. AC model consumes 55 VA maximum; DC model consumes 38 W. Cutout dimensions: 279mm W x 196mm H. Panel thickness range: 1.6 to 4.8 mm. Weight approximately 2.0 kg. The unit includes installation brackets and sealing gasket.

Compliance

The GT2310-VTBA and GT2310-VTBD comply with CE, UL/cUL, and RoHS standards. They are certified for use in industrial control equipment per EN 61000-6-2 (immunity) and EN 61000-6-4 (emissions). The DC model requires a Class 2 or SELV power supply. Optional accessories include protective sheets (GT23-4PSCB) and replacement mounting gaskets (GT23-4ATT).

Conclusion

The Mitsubishi GT2310-VTBA and GT2310-VTBD HMI touch screens deliver a large, bright display and robust connectivity for demanding industrial applications. With AC or DC power options, Ethernet, serial, USB, and SD card interfaces, these panels integrate seamlessly into Mitsubishi-based automation systems. Their rugged construction and intuitive programming environment make them a reliable choice for machine builders and system integrators.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Key Points for Selection and Deployment of MITSUBISHI FX3GE PLC
  • Beckhoff EP23xx EtherCAT Box Selection Troubleshooting
  • MITSUBISHI MDS-B servo troubleshooting
  • TOYO valve pressure and temperature selection
  • SIEMENS SIMODRIVE 611 HR/HRS Replacement and Advanced Positioning Techniques
  • SIEMENS SINUMERIK 840C 611-D Startup and Troubleshooting Guide
  • FANUC Series 0i-F Maintenance and Troubleshooting
  • Troubleshooting Schneider Modicon TM3 Bus Expansion
  • Troubleshooting of R&S EPL1000
  • Baum ü llerb b maXX 5000 Safety Configuration and Troubleshooting Guide
  • Huichuan AM600 Motion Controller Malfunction and Replacement Guide
  • Allen Bradley Ultra3000 Servo Motor Replacement Guide
  • NEC NL8060BC26-17 LCD Module Maintenance and Replacement
  • ABB Pluto Safety PLC Maintenance and Troubleshooting
  • OMRON NE1A Safety Controller Troubleshooting and Replacement
  • Allen Bradley 2711P series PanelView Plus human-machine interface terminal
  • NI cFP-22xx on-site integration and troubleshooting
  • KEYENCE XG-8000 Line Scan Visual Debugging Guide
  • OMRON G9SX Security Unit Configuration and Troubleshooting
  • OMRON CPM1A Maintenance and Troubleshooting
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide