Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • R&S EPL10200-W EMI Test Receiver
    ❤ Add to collection
  • R&S EPL10200-W EMI Test Receiver

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥26432.00
      ¥27747.00
      ¥26432.00
      ¥26432.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:18.460KG
    • Quantity:
    • (Inventory: 4643)
Description

R&S ® EPL1000 EMI Test Receiver: A Perfect Fusion of Speed, Flexibility, and Standard Compliance

In the field of electromagnetic compatibility (EMC) testing, precise, efficient, and fully compliant measuring instruments are indispensable tools in the hands of engineers. R&S launched by Rohde&Schwarz ® The EPL1000 EMI test receiver is an innovative product designed specifically for conducting emission measurements in the frequency range of 5 kHz to 30 MHz. It not only fully meets the requirements of CISPR 16-1-1, but also redefines the workflow of EMI pre compatibility testing and certification testing through revolutionary time-domain scanning technology, rich automation functions, and portable design.


Standard compliance and precise measurement: core foundation

R&S ® EPL1000 strictly follows the CISPR 16-1-1 standard and supports decimal 6 dB EMI bandwidth (200 Hz, 9 kHz, 120 kHz, 1 MHz, etc.) defined in MIL-STD-461 and DO-160 standards. Its core measurement capabilities include:

Multiple EMI detectors: Provide detectors with peak, quasi peak, CISPR average, RMS average, and other standard requirements to ensure consistency with certified laboratory results.

Built in Pre selection Filter: A fixed pre selection filter for CISPR A band (9 kHz-150 kHz) and B band (150 kHz-30 MHz), effectively suppressing image frequency, significantly improving dynamic range, and accurately identifying short pulses and small signals even in the presence of strong signals.

Pulse protection input: The input attenuator can reach 55 dB (1 dB step), and is integrated with a 20 dB preamplifier, combined with automatic adjustment function (Autosizing), to avoid signal link overload and maximize the use of dynamic range.

Conversion factor and limit line: Conversion factors including cable loss and LISN characteristics can be imported or customized. Built in over 170 common EMI standard limit wires (CISPR/EN/FCC/MIL-STD-461/DO-160), the measurement results are automatically compared with the limit values and displayed as PASS/FAIL.


Time domain scanning: Disruptive measurement speed

Traditional step scanning requires point by point measurement, which is time-consuming. R&S ® The EPL1000 uses Fast Fourier Transform (FFT) technology for Time Domain Scan (TDS), which can capture the entire CISPR A or B frequency band in one measurement cycle. For example, measuring CISPR B-band (150 kHz-30 MHz) only takes about 1 second (using peak detectors) or 3 seconds (using quasi peak/average detectors).

Gap free monitoring: The measurement time of up to 100 seconds can capture any occasional or intermittent interference signal, and all detected emissions belong to the same time segment, making it easy to analyze the correlation of interference.

Parallel multi detector: Up to three traces can be activated simultaneously, each of which can use different detectors (such as peak, quasi peak, and average). All required detection results can be obtained in one scan, without the need for step-by-step preview and final testing.


Automation function: Simplify the testing process

EPL1000 automates complex test sequences, significantly improving efficiency:

Automatic LISN line switching: via R&S ® The EZ-21 control cable is connected to a Rohde&Schwarz LISN (such as ENV216). Users only need to check the line (L, N, PE) to be measured on the screen, and the receiver automatically controls the LISN to switch and complete the complete frequency band measurement of all lines. For example, measuring the CISPR A/B frequency bands (quasi peak and average values) of two lines for LED lamps according to EN 55015 standard takes only about 13 seconds in total.

Scanning table: Multiple frequency bands can be defined, and each band can independently set parameters such as RBW, detector, measurement time, etc. The receiver automatically measures sequentially.

Report Generator: Built in report generation function, customizable templates and content, one click save as PDF or Word file, convenient for recording and exchanging test results.

Comprehensive EMI analysis capability

In addition to standard measurements, EPL1000 also provides powerful signal analysis tools:

Spectrum diagram function: Display the changes in level with frequency and time in 2D or 3D form, especially suitable for analyzing the evolution of signals or occasional components over time (such as emission changes during LED brightness adjustment).

IF Analysis (R&S) ® EPL1-K56): Combining bar chart display and spectrogram, accurately observe the modulation behavior near the specified frequency.

Zero span: Display the waveform of the level variation over time at the selected frequency, use markers to measure the period of periodic interference, and optimize the measurement time setting.

AM/FM audio demodulation: By monitoring the modulation characteristics of interference signals through built-in speakers or headphones, it helps identify environmental interference sources (such as broadcast signals in open field testing).

Spectrum analyzer mode: Provides the same universal spectrum analysis function as modern spectrometers, with one machine for multiple uses.


Flexible system integration and remote control

EPL1000 can be easily integrated into automated EMC testing systems:

Supports SCPI command set, which can be accessed through Ethernet or optional GPIB interface (R&S) ® FPL1-B10) for remote control and data reading.

Compatible with R&S ® ELEKTRA EMC testing software (basic version is R&S) ® ELEMI-E), Implement a complete EMC testing process from definition, execution, evaluation, and archiving.

Built in web server, remote desktop operation can be achieved by entering the IP address through the browser, and multiple users can access the same interface simultaneously.

Supports Microsoft Remote Desktop, providing a user experience similar to direct local control.


Mobility and Outdoor Use Design

The design of EPL1000 fully considers on-site testing requirements:

Flexible power supply: supports 100 V-240 V AC power supply; Optional DC input (R&S) ® EPL1-B30) supports 12 V-24 V vehicle power supply; Optional internal rechargeable lithium battery (R&S) ® EPL1-B31) provides approximately 2 hours of battery life and the battery is replaceable (R&S) ® FPL1-Z4), Satisfy long-term field testing.

Portable accessories: Optional soft carry bag (R&S) ® EPL1-Z2)、 Hard protective front cover (R&S ® EPL1-Z1)、 Shoulder strap (R&S) ® EPL1-Z3) and anti glare screen film (R&S) ® FPL1-Z5), Easy to use under direct sunlight.

Data Security: Optional replaceable SSD memory pack (R&S) ® EPL1-B19), After unplugging, the instrument does not retain any sensitive measurement data and is suitable for multi-user or multi site shared scenarios.


Specification Summary

Frequency range: 5 kHz to 30 MHz

EMI filter (6 dB): 10/100/200 Hz, 1/9/10/100/120 kHz, 1 MHz

Pre selection: Fixed low-pass (10 Hz-150 kHz) and band-pass (150 kHz-30 MHz)

Detector: maximum/minimum peak value, quasi peak value, CISPR average, RMS average

Display: 10.1-inch WXGA (1280 × 800) color touch screen

Size/Weight: 408 mm × 186 mm × 235 mm, approximately 6.9 kg (without battery)

Calibration interval: Recommended for 1 year

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • OMRON CK3W-AX Multi axis Control Selection
  • Debugging and maintenance of EPSON RC90/RC90-B controller
  • Nthytronic Group iRTUe I/O Expansion Module
  • Schneider ATV320 Inverter Installation and Debugging Guide
  • Eaton SPB Drawdown Switch Maintenance Guide
  • GFS EVO-SP dual fuel retrofit complete solution
  • OMRON CJ2 CPU Troubleshooting and Maintenance
  • Complete Guide to Lenze ECS Servo System
  • GE EX2100e Excitation System Complete Guide
  • OMRON G3PW Power Controller: Parameter Setting and Troubleshooting Guide
  • Key Points for Selection and Deployment of MITSUBISHI FX3GE PLC
  • Beckhoff EP23xx EtherCAT Box Selection Troubleshooting
  • MITSUBISHI MDS-B servo troubleshooting
  • TOYO valve pressure and temperature selection
  • SIEMENS SIMODRIVE 611 HR/HRS Replacement and Advanced Positioning Techniques
  • SIEMENS SINUMERIK 840C 611-D Startup and Troubleshooting Guide
  • FANUC Series 0i-F Maintenance and Troubleshooting
  • Troubleshooting Schneider Modicon TM3 Bus Expansion
  • Troubleshooting of R&S EPL1000
  • Baum ü llerb b maXX 5000 Safety Configuration and Troubleshooting Guide
  • Huichuan AM600 Motion Controller Malfunction and Replacement Guide
  • Allen Bradley Ultra3000 Servo Motor Replacement Guide
  • NEC NL8060BC26-17 LCD Module Maintenance and Replacement
  • ABB Pluto Safety PLC Maintenance and Troubleshooting
  • OMRON NE1A Safety Controller Troubleshooting and Replacement
  • Allen Bradley 2711P series PanelView Plus human-machine interface terminal
  • NI cFP-22xx on-site integration and troubleshooting
  • KEYENCE XG-8000 Line Scan Visual Debugging Guide
  • OMRON G9SX Security Unit Configuration and Troubleshooting
  • OMRON CPM1A Maintenance and Troubleshooting
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide