Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • B&R X20CM0985 PLC Module
    ❤ Add to collection
  • B&R X20CM0985 PLC Module

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥42267.00
      ¥45362.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:22.500KG
    • Quantity:
    • (Inventory: 5342)
Description
<span style="font-size: 18px; font-family: arial;">B&R X20CM0985 PLC Module</span>

B&R X20CM0985 Multi‑Measurement Transducer and Synchronization Module

The B&R X20CM0985 is a highly integrated multi‑measurement transducer and synchronization module within the X20 I/O system. It is designed to measure electrical parameters (voltage, current, power, frequency) from three‑phase AC networks and provide seamless synchronization between two independent power sources, such as a generator and the public grid. This module is ideal for power generation, energy monitoring, and grid connection applications. It simultaneously monitors two independent three‑phase mains networks plus two additional voltages, providing a complete solution for power quality analysis, generator control, and cogeneration systems.

Technical Specifications

ParameterValue
Model NumberX20CM0985 (ID code 0x2433)
Product TypeEnergy measurement and synchronization module
Input TypeAnalog voltage inputs (2 × 3‑phase networks), analog current inputs
Measurement Range (Voltage)120 V AC, 480 V AC (software selectable)
Rated Frequency48–62 Hz
Digital Outputs5 (FET, 0.5 A per channel, 24 V DC)
Relay Output1 (changeover contact, 1 A at 240 V AC / 30 V DC)
Power Consumption (Bus)1.4 W
Power Consumption (Internal I/O)4 W
Electrical Isolation500 Vrms (I/O‑bus), 4000 Vrms (relay to bus)
ATEX / UL CertificationATEX Zone 2, cULus HazLoc Class I Division 2
Operating Temperature (Horizontal)0°C to +60°C
Storage Temperature-40°C to +85°C
Protection RatingIP20

Functional Description

The X20CM0985 integrates both measurement and synchronization functions in a single module. It continuously acquires voltage and current signals from two independent three‑phase AC networks (e.g., generator busbar and grid busbar). The module calculates RMS values of voltage, current, active/reactive/apparent power, power factor, frequency, and total harmonic distortion (THD). The high‑speed data acquisition (conversion time configurable to 20 ms at 50 Hz or 16 ms at 60 Hz) ensures real‑time monitoring. The built‑in synchronization unit compares the phase angle, frequency, and voltage magnitude between the two networks and can control generator synchronization via the digital outputs. The module also features a low‑pass filter for total power readings, improving stability in noisy environments.

Measurement and Synchronization Capabilities

The module measures power in both 4‑wire (star) and 3‑wire (delta) network configurations. For voltage measurement, the inputs can be configured for either 120 V AC or 480 V AC ranges, automatically scaling the data. The current inputs accept signals from external current transformers (typical 1 A or 5 A). The module provides direct digital values (32‑bit integers) for each measured parameter, which are accessible via the X2X bus to the CPU. The synchronization unit can be used for generator controller applications, ensuring that the generator is synchronized with the grid before closing the breaker, preventing damage to equipment.

Digital and Relay Outputs

The X20CM0985 features five digital outputs (current‑sourcing FETs) rated at 0.5 A at 24 V DC. Each output is protected against short circuits and overtemperature, with diagnostic feedback to the CPU. These outputs can be used to control external contactors, circuit breakers, or alarm relays. The module also includes a single changeover relay output, rated for 1 A at 240 V AC or 30 V DC, suitable for low‑power switching applications, such as signaling a generator ready or a fault condition.

Integration with Automation Studio

The X20CM0985 is configured and programmed using B&R Automation Studio. The module appears as a device in the X2X I/O bus configuration. Standard function blocks are available for reading all measured values, performing synchronization, and controlling the outputs. The module also supports user‑defined scaling, filtering, and limit monitoring, with the ability to generate alarms when thresholds are exceeded. The diagnostic system continuously monitors the internal health of the module and the connected sensors, reporting any wire break or measurement errors.


Typical Applications

The X20CM0985 is used in:

  • Generator synchronizer panels (diesel or gas generators)

  • Energy management systems (power consumption monitoring in factories and buildings)

  • Cogeneration and renewable energy plants (grid connection monitoring)

  • Power quality analyzers (monitoring voltage sags, swells, and harmonics)

  • Distributed energy resource (DER) control systems

Installation and Wiring Overview

The module mounts on a B&R X20 base plate and connects via the X2X bus. It accepts 24 V DC power from the backplane. Voltage measurement connections are made using screw terminal blocks (included), with dedicated terminals for each phase (L1, L2, L3) and neutral. Current inputs use a separate plug‑in connector. Use shielded twisted‑pair cable for current transformer connections, with the shield grounded at the module end only. The digital outputs are protected against short circuits; however, external fusing (1 A) is recommended for each output. The relay contacts are not internally protected; add an external RC snubber for inductive loads.

Conclusion

The B&R X20CM0985 combines precise three‑phase power measurement and generator synchronization in a single compact module, simplifying the design of power monitoring and grid connection systems while reducing the need for separate measuring instruments.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Deployment and Performance Optimization of ADLINK MXC-6400 Industrial Control Computer
  • Selection and Deployment of ADLINK Matrix Series Industrial Control Computers
  • российские промышленные новые машины.Наш отдел дебютировал в 2026 году в России Международная промышленная ярмарка INNOPROM
  • Deeply cultivating the Eurasian industrial market, linking new industrial opportunities between China and Russia
  • Deployment and troubleshooting of ADLINK GIE64+PoE acquisition card
  • Honeywell UMS Security System Troubleshooting Guide
  • Honeywell Expert Series C I/O Troubleshooting Guide
  • ADLINK EOS-1200 Vision System Deployment and Troubleshooting
  • ADLINK DLAP-5200 series AI engine deployment and optimization
  • ADLINK DLAP-4000 Deployment and BIOS Optimization
  • ADLINK Matrix MXC-2000 Deployment and Troubleshooting
  • ADLINK DAQe-2000 series acquisition card calibration and synchronization
  • ADLINK cPCI-6520 Core i7 Processor Blade Engineering Application Guide
  • ADLINK CM1-86DX3 PC/104 Embedded Single Board Computer Engineering Application Guide
  • Honeywell DC1000 Series PID Temperature Controller Engineering Application Guide
  • ALSTOM MiCOM C264 Substation Controller Engineering Application Guide
  • EMERSON AMS 2140 Practical Guide for On site Dynamic Balance and Vibration Analysis
  • ADLINK NuPRO-E320 motherboard deployment and tuning guide
  • ADLINK NuPRO-800 Dual PIII Industrial SBC Maintenance and Upgrade Guide
  • ADLINK NuPRO-598 SBC Maintenance Practical Guide
  • ADLINK MXC-6300 Fanless Embedded Industrial Control Computer Deployment Guide
  • ADLINK Express-BASE7 Carrier Board Quick Deployment and Debugging Guide
  • ADLINK DLAP-211 Edge AI Platform Selection and Deployment Guide
  • ADLINK 7230 Series Isolation DIO Card Selection and Engineering Application Guide
  • ADLINK cPCI-6965 SBC Embedded Installation and BIOS Tuning Guide
  • ADLINK 7200 Series High Speed DIO Card Practical Guide
  • ADLINK DLAP Series Edge AI Acceleration Platform Selection and Deployment Practical Guide
  • DEIF TCM-2 thyristor control module: Wind power cut in control engineering guide
  • DEIF MVR-200 Medium Voltage Relay: Installation and Wiring Engineering Guide
  • DEIF MDR-2 Differential Relay: Engineering Guide for Generator Differential Protection
  • DEIF Delomatic 3 AOM: Engineering Guide for Analog Output Modules
  • DEIF AGI 400 Graphic Interface: Ship and Industrial HMI Solution
  • DEIF BRW-1 Marine Instruments: Installation and Calibration Guide for Offshore Bridge Indicators
  • DEIF AGC 200 Controller: Quick Deployment and Configuration Guide for Generator Sets
  • DEIF AGC-2 Controller: The Ultimate Guide to Automatic Control and Protection of Generator Sets
  • ABB SPA-ZC400 Gateway: REM54x Access to IEC 61850 Ultimate Engineering Guide
  • ABB REM 543/545 Terminal
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module
  • Beckwith M-3520 Interconnection Protection Relay
  • Beckwith M-3430 Generator Protection Relay
  • Beckwith M-2293B adapter panel replacement GE regulator guide
  • Selection and Networking of Beckwith M-2001C Digital Voltage Regulating Controller
  • Beckwith M-2001B Digital Voltage Regulating Controller
  • Beckwith M-0388/M-0389 Synchronous Inspection Relay Application Guide
  • Beckwith M-0193B Synchronizer Debugging and System Integration Guide
  • Beckwith M-0115A Parallel Balance Module Debugging Guide
  • Beckwith M-0067E On Load Voltage Regulating Controller Selection and Debugging Guide
  • Debugging and Fault Handling of Beckwith M-4272 Digital Busbar Conversion System
  • Beckwith M-3311A Transformer Protection Relay Debugging Guide
  • Beckwith M-3425A Generator Protection Relay Debugging Guide
  • Setting and troubleshooting of Basler BE1-27/59 voltage relay
  • Debugging and troubleshooting of Basler AVC63-12/AVC125-10 voltage regulator
  • Basler L301kc Line Array Camera Technology and Troubleshooting
  • Selection and Debugging of Basler CBS 212A Current Boosting System
  • Selection and commissioning of Basler BE3-25 synchronous inspection relay
  • Basler BE1-32R/32O/U Direction Power Relay Setting and Testing Guide
  • Basler PRS 250 Synchronous Relay Maintenance and Replacement Guide
  • Basler piA2400-17gc Industrial Camera Replacement and Optimization Guide
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection
  • Basler SSR Static Voltage Regulator: A Complete Guide to Debugging and Troubleshooting
  • Basler SR4A/SR8A Voltage Regulator: Detailed Debugging and Troubleshooting Explanation
  • Basler BE2000E Voltage Regulator: Replacement and Application Details
  • Basler DECS-2100 Excitation System: Modular Upgrade and Engineering Application
  • Basler BE1-851 Overcurrent Protection System: A Complete Guide to Professional Debugging and Troubleshooting
  • Basler APR 63-5 Voltage Regulator: Professional Debugging and Troubleshooting Guide for Industrial Generator Excitation Systems
  • Basler BE1-FLEX Protection System: A Complete Guide to Professional Installation, Configuration, and Troubleshooting
  • Debugging and Testing of Basler BE1-700 Relay
  • Basler BE1-87B busbar differential setting test
  • Basler BE1-40Q demagnetization relay setting test
  • Basler BE1-60 Voltage Balance Relay Setting Test
  • Basler BE1-47N Relay Field Setting and Testing Guide
  • Basler BE1-81O/U Frequency Relay: On site Debugging and Protection Configuration Guide
  • Basler BE1-11f Feedline Protection System Debugging and Troubleshooting Guide
  • Basler DECS-250 Excitation System: Installation, Configuration, and Troubleshooting Practice Guide
  • Basler DECS-100 Digital Excitation System Debugging Guide
  • Application Guide for Basler BE1-BPR Circuit Breaker Protection Relay
  • Basler BE1-50/51B-255 Replacement CO Relay Guide
  • Basler BE1-25 synchronous inspection relay principle and testing
  • Basler BE1-51 Time Overcurrent Relay Debugging Guide
  • Practical Guide to Basler DECS-300 Digital Excitation System
  • Mitsubishi FX Series PLC Data Communication Practical Manual
  • Selection of Hirschmann cSCALE S6/C8 Mobile Safety Controller
  • Hirschmann OZD Profi G12D repeater explosion-proof installation configuration
  • Hirschmann OCTOPUS OS20/24 Switch Installation Power Supply
  • Hirschmann RS20/30/40 Switch Selection and PoE Deployment
  • Hirschmann EAGLE One Firewall Installation and Configuration Guide
  • Hirschmann MACH102 Switch Installation and Power Supply Guide
  • Hirschmann MICE MS20/MS30 Installation and DIP Configuration
  • Hirschmann BOBCAT BRS Switch Installation and Power Supply Guide
  • Hirschmann RSB20 Switch Deployment and Redundant Configuration
  • Hirschmann RS20 Basic Switch Installation and Debugging Guide
  • BECKHOFF EP20xx/EP28xx Output Module Installation and Debugging Guide
  • BECKHOFF EL5102 Encoder Terminal Debugging and Troubleshooting
  • BECKHOFF CU8803 Launch Box Installation and Explosion proof Guide
  • BECKHOFF CU20xx/CU22xx Switch Installation and Troubleshooting
  • BECKHOFF AMP8000 Servo Drive Installation and Debugging Manual
  • BECKHOFF EL2911 Safety Feed Terminal Debugging Guide
  • BECKHOFF EL600x/EL602x Serial Port Module Debugging Manual
  • BECKHOFF CP6700 Panel PC Installation and Maintenance Manual
  • BECKHOFF CP70xx panel maintenance and troubleshooting
  • BECKHOFF CP29xx Panel Installation and Troubleshooting
  • Beckhoff C6650-0060 Industrial Control Computer Hardware Architecture and RAID Data Security
  • Beckhoff BK1120/BK1250 EtherCAT Coupling Debugging and KL Terminal Parameterization Complete Guide
  • Beckhoff CX20x0 Embedded Controller Hardware Maintenance and Troubleshooting Complete Manual