ABB 15.04.2005 Instrument Transformer

来源: | 作者:FAN | 发布时间 :2025-06-20 | 248 次浏览: | Share:

ABB 15.04.2005 Instrument Transformer

Current transformer

Basic functions and principles

Function: Convert high current in power transmission and distribution systems into low current for use in low-voltage measurement and protection equipment. The secondary current is usually 1A or 5A, connected in series, and the secondary winding is mainly connected to an ammeter and protection relay.

Principle: Through electromagnetic induction, the secondary current is proportional to the primary current, and the conversion ratio K=I ₚᵣ/I ₛᵣ=N ₂/N ₁, where I ₚᵣ is the primary current, I ₛᵣ is the secondary current, N ₁ and N ₂ are the turns of the primary and secondary windings, respectively. The secondary current I ₛᵣ=I ₚᵣ × N ₁/N ₂. It can have one or more secondary windings, each with an independent magnetic circuit, used for different purposes such as metering or protection.

ABB变频器ACS550-01-08A8-4/012A/015A/023A/4KW5.5KW

Key parameter

Rated primary current (I ₚₑ): The primary current value based on the performance of the transformer, which needs to be equal to or higher than the highest primary current of the system. The standard value is in accordance with IEC regulations, such as 10, 12.5, and their decimal multiples. It can also be produced in any proportion according to the protocol, usually with a 120% extended current range to avoid high temperature rise during installation.

Frequency: It can be set as 50Hz or 60Hz, or a combination of 50/60Hz, and 16 ⅔ Hz is also possible, depending on the network of each country.

Equipment maximum voltage (U ₘ): The insulation level should be set to be equal to or higher than the system maximum voltage U ₛᵧₛ (except for cable current transformers, whose insulation is provided by the application), with standardized values, such as 3.6kV corresponding to system voltage up to 3.3kV, etc.

Insulation level: Based on the U ₘ value, such as IEC insulation level 12/28/75kV, it represents the highest voltage, power frequency withstand voltage (effective value), and lightning impulse withstand voltage (peak value) of the equipment, respectively.

Accuracy level: divided into measurement class (0.2, 0.2S, 0.5, 0.5S, 1, 3) and protection class (5P, 10P, PX, TPX, TPY, TPZ), different levels are suitable for different purposes such as tariff measurement, laboratory measurement, protection, etc. The chart shows the current ratio error limit of commonly used measurement classes.

Secondary current and number of windings: The secondary current is 1A or 5A, and the number of windings depends on the size of the body. For example, the maximum 36kV TPU 7x.6x can have up to 8 iron cores.

System primary current (I ₛᵧₛ): The system current for installing transformers needs to be equal to I ₚᵣ, and different applications have different calculation methods. For example, the transformer feeder I ₛᵧₛ=S/(√ 3 × U ₛᵧₛ), the capacitor feeder I ₛᵧ=1.3 × Q/(√ 3 × U ₛᵧₛ), where S is the apparent power (kV). A), U ₛᵧₛ is the system voltage (kV), and Q is the reactive power of the capacitor (kVar).

Rated short-time thermal current (I ₜₕₙ): The maximum primary current that a transformer can withstand for a specified short period of time without causing harmful effects. The standard values are 2, 4kA, etc., and the duration standard is 1 second, or possibly 3 seconds. The rated dynamic current I dyn is 2.5 times I ₜₕ at 50Hz.

Extended current rating (EXT): The range of current increase that a current transformer can measure at an accuracy level, such as 120%.

Maximum continuous thermal current (I ₜₕ): The maximum continuous thermal current that the current transformer can still operate but is not at the accuracy level.

Accuracy Limiting Factor (ALF): Used for protection purposes, it defines the multiple of primary current that the error must meet. For example, 5P20 represents a composite error of ≤ 5%, and the error limit from 100% primary current to 20 times primary current must be met. ALF is related to the load, and unexpected increases in load can cause ALF to decrease. The actual load required for the secondary iron core, secondary circuit, and connecting equipment needs to be calculated. Different instrument loads vary, such as 0.5-4VA for ammeters, and cable losses need to be compensated.

Safety factor (FS): Used for measurement purposes, it protects all devices connected on the secondary side by setting iron core saturation to avoid secondary high current transmission during faults. For example, FS5 indicates an error of ≥ 10% under rated load at 5 times the rated primary current.

Environmental temperature and insulation level: Environmental temperature is divided into three categories according to IEC: -5/40 ° C, -25/40 ° C, and -40/40 ° C. The insulation level of ABB products corresponds to Class E, which means the maximum temperature rise of all active components is about 75K.


Other features

Capacitive voltage divider: integrated into the current transformer body, making voltage indication more convenient.

Reconnect: It can be achieved on the secondary or primary side. The left side features a dual core design with a secondary reconnection tap, while the right side has a primary reconnection that requires manual operation.

standard

Compliant with IEC 61869 standard, it can also be produced according to GOST, IEEE and other standards. Please consult the sales representative.

voltage transformer

Basic functions and principles

Function: Provide a secondary voltage proportional to the primary voltage for the secondary circuit, typically 100V, 110V, or 120V.

Principle: Through electromagnetic induction, the conversion ratio K=U ₚₑ/U ₛᵣ=N ₁/N ₂, where U ₚₑ is the primary voltage, U ₛᵣ is the secondary voltage, and N ₁ and N ₂ are the number of turns in the primary and secondary windings, respectively. The number of turns in the primary winding is greater than that in the secondary winding.


Key parameter

Rated primary voltage (U ₚₜ)

From the perspective of connection, it is divided into phase to phase voltage and phase to ground voltage, such as phase to phase voltage of 10000//100V, phase to ground voltage of 10000/√ 3///100/√ 3, 100/3V. The commonly used values specified by IEC include 3.3, 6.6kV, etc.

Rated secondary voltage: Any ratio can be produced, but the standard secondary voltage is preferred to be 100, 110, or 120V. When single-phase transformers are connected to ground, the rated secondary voltage for star connections needs to be divided by √ 3, and for open delta connections it needs to be divided by 3. Mixed ratio voltage transformers can also be produced.

Rated voltage factor: used to determine the maximum voltage that the transformer must meet the relevant thermal and accuracy requirements within a specified time. The ABB single pole voltage transformer is designed to be 1.9 × U ₚᵣ/8h, and the double pole is 1.2 × U/continuous. Different voltage factors can be discussed with the sales representative.


Number of windings and reconnection

Up to three secondary windings can be produced for measurement, protection, or ground fault indication, and can also be reconnected, such as a single pole insulated transformer with two secondary tap windings, one of which is the remaining winding.

Accuracy level: There are measurement categories of 0.2, 0.5, 1, and 3, and protection (a-n) and/or residual (da dn) categories of 3P and 6P. The measurement category is between 80% and 120% of the rated voltage at rated frequency, with voltage error not exceeding the IEC specified value. The protection category is within the range of 5% of the rated primary voltage to the rated voltage factor multiplied by the rated primary voltage (such as 190% when 1.9 times the rated primary voltage), with voltage ratio error not exceeding 3% (3P category) or 6% (6P category).

Fuse: In the supply of fuses for single pole voltage transformers, there are different specifications for the rated current, voltage, and whether the fuse has a firing pin.


Terminal markings

According to IEC standards, single pole primary winding A-N, secondary winding a-n (star), da dn (open triangle); Bipolar primary winding A-B, secondary winding a-b.

Thermal output: Under star connection and rated primary voltage U ₚᵣ, the maximum power that the transformer can achieve with a ratio error of ± 10%. Different voltage levels have different thermal output values, such as 12-17.5kV (TJC 4&TJC 5) and 400VA.


Other features

Parameters such as frequency, insulation level, ambient temperature, standard, cable loss, and load are the same as those of current transformers.

Example

Purchase order example: Current transformer TPU 40.13, 50//5/5 A, EXT 120%, 15/15 VA, 0.5FS5/5P10 grade, I ₜₕ=40kA/s, I dyn=100kA,12/28/75 kV,50Hz,IEC 61869 - 2, Environmental temperature 40 ° C, polarity P1-P2, with capacitive voltage divider.

ABB热继电器 型号TA25DU-1.8M (1.3-1.8A) 顺丰包邮 现货

  • ABB UAC389AE01 HIEE30088R0001 module controller
  • ABB AI02J high-performance I/O module
  • ABB IC698CPE030/IC698CPE020 series battery cover
  • ABB KSD211B 3BHE022455R1101 Input Coupling Unit ICU
  • ABB DSCA190V 57310001-PK Communication Processor
  • ABB GFD563A102 3BHE046836R0102 Analog I/O module
  • ABB XVC768115 3BHB007211R115 Industrial Control Module
  • ABB AI815 3BSE052604R1 I-O Module
  • ABB 5SGY3545L0010 3BHB006485R0001 Controller Module
  • ABB DAPI100 3AST000929R109 Ethernet Communication Interface Module
  • ABB SYN5201A-Z,V277 3BHB006714R0277 Auto single channel Syn
  • ABB KUC755AE117 3BHB005243R0117 System Controller
  • ABB CMA130 3DDE300410 Display Front Panel
  • ABB 07DC92D GJR525220R0101 Digital I/O Module
  • ABB PCD237A101 3BHE028915R0101 excitation control module
  • ABB CI627A 3BSE017457R1 Communication Interface
  • ABB 5SHY4045L0004 3BHB021400R0002 3BHE039203R0101 GVC736CE101 thyristor IGCT
  • ABB SYN5202A Controller Module
  • ABB LWN2660-6E 3BHL000986P7002 Power Conversion Module
  • ABB PFCA401SF 3BSE024387R4 Control Unit
  • ABB HIEE401807R0001 Advanced Power Electronics Module
  • ABB VBS01-EPD High Performance Digital Signal Processing Module
  • ABB LWN2660-6EG 3BHL000986P7002 Industrial Control Module
  • ABB SYN5201A-Z 3BHB006714R0217 Hydraulic Servo Module
  • ABB SYN5200a-Z,V217 SYNCHROTACT5 3BHB006713R0217 Dual channel synchronization device
  • ABB SAM3.0 Surge Arrester Monitoring System
  • ABB UNITROL 1005-0011 ECO 3BHE043576R0011 Automatic Voltage Regulator
  • ABB 3BHE032025R0101 PCD235B101 Exciter Control Module
  • ABB 3BHE006373R0101 XVC769AE101 INVERTER MODULE
  • ABB UFC765AE102 3BHE003604R0102 High-Performance PC Board
  • ABB 3BHE004573R0143 UFC760BE143 INTERFACE BOARD
  • ABB KUC720AE101 3BHB003431R0101 3BHB000652R0101 Controller Module
  • ABB HIEE300927R0101 UBC717AE101 High Voltage Inverter Board
  • ABB UFC721AE101 3BHB002916R0101 PC Board
  • ABB 5SHY4045L0003 3BHB021400 3BHE019719R0101 GVC736BE101 Diode and grid drive circuits
  • ABB 3BHE019719R0101 GVC736BE101 IGCT Module
  • ABB REM620A_F NAMBBABA33E5BNN1XF Protective Relay
  • ABB PPD113B03-26-100110 3BHE023584R2634 Power Distribution Module
  • ABB MB810 Module Mounting locations
  • ABB 3BHL000986P7000 LXN1604-6 POWER SUPPLY
  • ABB VBX01BA I/O Control Module
  • ABB AI03 AI module, 8-CH, 2-3-4 Wire RTDs
  • ABB 1TGE120010R1300 Industrial Control Module
  • ABB 216BM61b HESG448267R1021 Advanced Process Control Module
  • ABB BDD110 HNLP205879R1 Digital I/O Module
  • ABB IEMPU02 Power Supply Module
  • ABB G3FE HENF452697R1 High performance control module
  • ABB G3FD HENF452692R1 High-Performance Industrial Control Module
  • ABB B5EC HENF105077R1 Electronic Motor Protection Relay
  • ABB G3EFa HENF450295R2 Industrial Automation Module
  • ABB B5EEd HENF105082R4 Electronic Motor Protection Relay
  • ABB O3EId HENF452777R3 Digital Output Module
  • ABB NWX511a-2/R HESG112548R12 Industrial Automation Module
  • ABB E3ES Power communication module
  • ABB O3EX HENF315845R2 Industrial Control Module
  • ABB O3EHa HENF315087R2 Digital Output Module
  • ABB E3ED High-Performance Industrial Controller
  • ABB O3EGb HENF315118R2 Digital Output Module
  • ABB O3ED Digital Input Module
  • ABB O3ES HENF445789R1 Digital Input Module
  • ABB G3ESa HENF318736R1 control module
  • ABB 8025-235 Industrial Control Module
  • ABB 216NG61A HESG441633R1 HESG216875/K main control board
  • ABB SCYC51020 58052582G programmable Logic Controller
  • ABB RED670 Line differential protection
  • ABB PP825A 3BSE042240R3 Touch Screen Panel
  • ABB SCYC51020 58052582/G pulse trigger board
  • ALSTOM COP232.2 VME A32/D32.029.232 446 Controller Unit
  • ABB AO2000 LS25 Laser analyzers
  • ABB LM80 Laser level transmitter
  • ABB PM803F 3BDH000530R1 Base Unit 16 MB
  • ABB SD822 3BSC610038R1 Power Supply Device
  • ABB PCD235B1101 3BHE032025R1101 Industrial Control Module
  • ABB AZ20/112112221112E/STD Control Module
  • ABB UAD142A01 3BHE012551R0001 Industrial Control Module
  • ABB 5SHY35L4503 3BHB004693R0001 3BHB004692R0002 5SXE01-0127 main control board
  • ABB FET3251C0P184C0H2 High-Performance Power Module
  • ABB CAI04 Ability ™ Symphony ® Plus Hardware Selector
  • ABB R474A11XE HAFAABAAABE1BCA1XE output hybrid module
  • ABB REF542PLUS 1VCR007346 Compact Digital Bay Control
  • ABB REF542PLUS 1VCF752000 Feeder Terminal Panel
  • ABB PPD113B03-26-100100 3BHE023584R2625 output hybrid module
  • ABB 3BHE022293R0101 PCD232A Communication Interface Unit
  • ABB CI857K01 3BSE018144R1 Module Controller
  • ABB 3ASC25H216A DATX132 Industrial Controller
  • ABB LWN2660-6 High-Voltage Industrial Controller
  • ABB 1MRK00008-KB Control Module
  • ABB SC540 3BSE006096R1 Submodule Carrier
  • ABB REF615C_C HCFFAEAGANB2BAN1XC feeder protection and measurement and control device
  • ABB S-073N 3BHB009884R0021 multi-function servo driver
  • ABB SK827005 SK827100-AS 480V 60HZ coil
  • GE 029.381208 module
  • ABB REF615E_E HBFHAEAGNCA1BNN1XE Module
  • ABB TP830 3BSE018114R1 Baseplate Module
  • ABB TK803V018 3BSC950130R1 Cable Assembly
  • ABB DSRF197 3BSE019297R1 Controller Module
  • ABB DSAO120A 3BSE018293R1 Advanced Analog Output Board
  • ABB DSDP170 57160001-ADF Pulse Counting Module
  • ABB DSBC176 3BSE019216R1 Bus Extender Board
  • ABB DSDO115A 3BSE018298R1 Digital Output Module
  • ABB PM865K01 3BSE031151R1 Processor Unit HI
  • ABB 5SHY3545L0016 3BHB020720R0002 3BHE019719R0101 GVC736BE101 auxiliary DC power supply unit
  • ABB TP853 3BSE018126R1 Power Supply Module
  • ABB REM545AG228AAAA High Precision Control Module
  • ABB CI626A 3BSE005029R1 Communication Interface Module
  • ABB REM615C_D HCMJAEADAND2BNN1CD Motor protection and control
  • ABB TP857 3BSE030192R1 DCS System
  • ABB PP865A 3BSE042236R2 Touch Panel
  • ABB SCYC51020 58052582H Industrial Automation Control Module
  • ABB SCYC51090 58053899E Control Module
  • ABB CB801 3BSE042245R1 Profibus DP Slave Expansion Module
  • ABB 5SHY4045L0001 3BHB018162R0001 IGCT Module
  • ABB 5SHY6545L0001 AC10272001R0101 5SXE10-0181 High-Power IGCT Module
  • ABB RMU811 Module Termination Unit
  • ABB TVOC-2-240 1SFA664001R1001 Industrial Control Module
  • ABB LDSTA-01 63940143B Input/Output (I/O) Module
  • ABB GJR5252300R3101 07AC91H Analog Input/Output Module
  • ABB GJR5252300R3101 07AC91F Industrial Control Module
  • ABB TB711F 3BDH000365R0001 Industrial Control Module
  • ABB TU715F 3BDH000378R0001 I/O Terminal Unit (ITU)
  • ABB DC732F 3BDH000375R0001 Industrial Controller
  • ABB TTH300 Head-mount temperature transmitter
  • ABB UNS3670A-Z V2 HIEE205011R0002 Industrial Automation Module
  • ABB RC527 3BSE008154R1 Redundant System Control Module
  • ABB 5SHY5055L0002 3BHE019719R0101 GVC736BE101 Industrial Control Module
  • ABB PM866 3BSE050200R1 AC800M series PLC core controller
  • ABB UFC718AE01 HIEE300936R0001 Main Circuit Interface Board
  • ABB DSAI130A 3BSE018292R1 Industrial I/O Module Controller