The WATLOW ANAFAZE configuration, encompassing components LLS200212, E257034, CLS208, and 208-1200000, represents a professional-grade, integrated temperature control system engineered for demanding industrial applications. This solution pairs Watlow's reliable heating technology with precise digital control to deliver consistent thermal performance. Designed as a cohesive unit, it simplifies the implementation of accurate heating processes by combining a robust heating element (LLS Series) with an intelligent, user-programmable controller (CLS Series), offering a complete package for engineers and system integrators.
This ANAFAZE system is not a single component but an engineered assembly. The LLS200212 typically refers to a specific model within Watlow's LLS line of air process heaters or similar heating elements, known for their efficient heat transfer and durable construction. The CLS208 designates a digital temperature controller from the CLS series, providing the brain for the system with PID control, alarm management, and communication capabilities. The additional codes (E257034, 208-1200000) often relate to specific assembly versions, wiring harnesses, or configuration kits that ensure these components work together optimally. The integrated design ensures compatibility and reduces engineering time for the end-user.
The combined system offers distinct benefits over sourcing components separately:
Pre-Engineered Compatibility: The heater and controller are matched for electrical and thermal performance, ensuring safe operation and optimal control response.
Precise PID Control: The CLS208 controller delivers accurate temperature regulation using advanced algorithms, minimizing overshoot and improving process consistency.
Robust Heating Element: The LLS-series heater is built for industrial environments, offering reliable heat output and longevity even in demanding applications.
Integrated Safety: The system incorporates protective features such as overtemperature alarms, sensor break detection, and heater fault monitoring.
User-Friendly Interface: The controller features an intuitive display and keypad for easy setpoint adjustment, parameter configuration, and process monitoring.
Simplified Installation: Coming as a matched set, it reduces wiring complexity and ensures correct electrical connections between the heater, sensor, and controller.
Communication Ready: The CLS controller often supports industry-standard communication protocols (e.g., Modbus, Ethernet/IP) for integration into broader control networks.
The table below outlines the general specifications for the primary components within this ANAFAZE system.
| Component / Parameter | Typical Specification |
|---|---|
| System Designation | ANAFZE Integrated Temperature Control System |
| Heater Model (Example) | LLS200212 (Air Process Heater) |
| Controller Model | CLS208 (Digital Temperature Controller) |
| Controller Input | Thermocouple (J, K, etc.) or RTD |
| Control Output | SSR Drive, Relay, or Analog for heater power control |
| Heater Power & Voltage | Varies by LLS model (e.g., kW rating at standard AC voltage) |
| Control Features | PID with auto-tune, dual displays, alarm relays |
| Communication | Optional serial or Ethernet communication module |
| Primary Function | Closed-loop temperature control for process air or gases |

LLS Heater (e.g., LLS200212): This is the heating element that converts electrical energy into thermal energy. It is designed with specific watt density and airflow characteristics to heat air or other gases effectively and safely.
CLS208 Controller: This is the control unit. It reads the temperature from a sensor (thermocouple/RTD), compares it to the user-defined setpoint, and calculates the necessary output to the heater to maintain the desired temperature.
Integration Components (E257034, 208-1200000): These parts may include mounting hardware, pre-wired cables, connection terminals, or specific configuration files that facilitate the physical and functional integration of the heater and controller into a single, easy-to-install package.
This integrated Watlow system is designed for applications requiring precise control of air or gas temperature:
Packaging Machinery: Heating air for shrink tunnels, seal bars, or label application.
Plastics Processing: Temperature control for hopper dryers, mold temperature units, or portable air heaters.
Laboratory & Test Equipment: Providing controlled heat for environmental chambers, ovens, or specialized test rigs.
Food Processing: Dryers, proofers, or dehydration processes.
Industrial Process Air: Heating make-up air, process air for drying, or combustion air pre-heating.
The WATLOW ANAFAZE system incorporating the LLS200212 heater and CLS208 controller offers a robust, pre-validated solution for industrial temperature control challenges. By providing a matched set of high-quality components, it reduces design risk, accelerates deployment, and ensures reliable performance. This integrated approach is ideal for OEMs and end-users who require a dependable, accurate, and easy-to-install thermal management system for their critical processes. For specific installation, electrical, and safety details pertaining to the exact configuration (including E257034 and 208-1200000), consulting the official system documentation is imperative.