ADLINK MXE-230 series Alder Lake platform industrial computer deployment and maintenance manual

F: | Au:FANS | DA:2026-08-17 | 47 Br: | 🔊 点击朗读正文 ❚❚ | Share:

ADLINK MXE-230 series Alder Lake platform industrial computer deployment and maintenance manual

Introduction: A New Generation Compact Industrial Control Platform for Intelligent Edge

With the acceleration of integration of industrial IoT and AI edge computing, field controllers need to integrate stronger computing power, faster storage interfaces and richer I/O scalability in limited space. The ADLINK Matrix series MXE-230 is an ultra compact ruggedized edge computer designed based on this requirement. This platform is equipped with Intel Alder Lake-N series or Amston Lake series processors (with the highest quad core E-core architecture), supporting DDR5 4800MHz memory, three-way M.2 expansion (B/E/M-Key), dual gigabit industrial Ethernet (i210IT), and dual three in one switchable serial ports. It also provides optional 2.5KV isolated digital I/O (8DI/8DO), suitable for harsh scenarios such as smart factories, traffic monitoring, and new energy management.


Analysis of hardware architecture and SKU differences

1.1 Processor and Memory

CPU: Intel Alder Lake-N series (such as N97, quad core 3.6GHz) or Amston Lake series, using Gracemont energy-efficient core architecture, with a TDP of approximately 12W.

Memory: Single DDR5 SO-DIMM slot, up to 16GB @ 4800MHz. Compared to DDR4, the bandwidth has increased by about 50%, resulting in significant gains for data caching and AI inference tasks.

1.2 SKU configuration differences (key)

MXE-230 offers multiple SKUs to adapt to different application scenarios, mainly reflected in height and I/O configuration:

SKU height serial port digital I/O network port

MXE-231 (basic type) 62mm 2 × RS-232/422/485 without 2 × GbE

MXE-231/4LAN 75mm 2 × RS-232/422/485 without 4 × GbE

MXE-231/4COM 75mm 4 × RS-232/422/485 (with 2 isolated channels) 8DI/8DO (2.5KV) 2 × GbE

MXE-231/6COM 75mm 6 × RS-232/422/485 (including 2 isolated channels, 2 standard channels) 8DI/8DO (2.5KV) 2 × GbE

Engineering reminder: When selecting, the SKU should be determined based on the required number of serial ports on site and whether DIO isolation is needed. If more than 4 serial ports or isolated I/O are required, the 75mm height version must be selected.

1.3 Storage and Expansion

M. 2 M-Key (2280): Supports NVMe SSD, PCIe Gen3 × 2 speed (approximately 16Gbps), used for high-speed system disks.

M. 2 E-Key (2230): Supports Wi Fi/Bluetooth module (PCIe+USB) for wireless connection.

M. 2 B-Key (3042): Supports 4G/LTE modules (only USB 3.0+USB 2.0, no PCIe), and works with external antennas to achieve cellular communication.

SATA port: Additional 1 SATA III (6Gbps) and SATA power cable are provided, which can install 2.5-inch SSD/HDD.


Practical operation of mechanical installation and expansion module

2.1 Dimensions and Installation Method

Basic dimensions: 165 (W) × 120 (D) × 62 (H) mm (standard type); 75mm high version is used for 4LAN/4COM/6COM SKUs.

Wall mounted installation: Comes with two wall brackets, fixed with M4 screws. Safety constraint - As the antenna interface is located on the front panel, it is necessary to ensure that the front and rear panels are on both sides when wall mounted. It is strictly prohibited to face the wall from the top or bottom to avoid affecting the radiation efficiency of the antenna.

DIN rail installation: Optional rail bracket, suitable for standard 35mm DIN rail installation.

2.2 Installation steps of M.2 module (key operations)

Dismantling the top cover: Unscrew the top 4 screws and the rear 2 screws.

Remove the heat sink: Unscrew the 2 fixing screws on the M.2 heat sink, carefully remove the heat sink, and be careful not to damage the thermal pad (if the pad is damaged, it needs to be replaced to ensure thermal conductivity).

Installation module: Insert the M.2 module into the corresponding slot at an angle of about 30 ° (pay attention to the foolproof notch), and press it down to the horizontal.

Restore the heat sink: Cover the heat sink on the module and tighten the screws. Improper installation may lead to module overheating, speed reduction, or even damage.

Sealed top cover: Replace all screws to ensure grounding continuity.

Important reminder: B-Key module only supports USB signal, do not insert PCIe/NVMe module; M-Key only supports NVMe and does not support SATA protocol.

2.3 SATA SSD Integration

Reserved SATA data cable and power cable (SATA Power Wafer) inside the device for connecting 2.5-inch SSDs. The SSD needs to be fixed in a reserved position inside the chassis (usually using bottom screw holes).


Power Design and Power Management

3.1 Power Input

Interface: DC Jack (positive inside and negative outside) or pluggable terminal (specific configuration needs to be confirmed).

Input voltage: 12V~24V DC (typical industrial 24V).

Minimum power supply: It is recommended to be no less than 40W, considering high temperature derating (such as leaving a 20% margin for power output in a 60 ° C environment).

3.2 Reference for power consumption measurement (12V power supply)

Power consumption under working conditions

Shutdown (S5) 3.9W

System idle 12.3W

Processor fully loaded 30.1W

System full load (CPU+IO) 30.3W

Thermal management: The main heating elements (CPU, PCH) are located on the left side, in contact with the heat sink and aluminum casing through a thermal pad. Be sure to leave at least 5cm clearance below the device to ensure natural convection. Working temperature range -20 ° C~60 ° C (storage -40 ° C~85 ° C); If using an AC adapter (non DC direct supply), the upper limit is reduced to 50 ° C.


Key interface definition and signal integrity

4.1 DB9 serial port (COM1/COM2)

Independently switch between RS-232/422/485 modes through BIOS without the need for jumper wires:

Pin RS-232 RS-422 RS-485

1 DCD# TXD- 485-

2 Rx TXD+ 485+

3 Tx RXD+ N/C

4 DTR# RXD- N/C

5 GND GND GND

RS-485: Two wire half duplex, requires 120 Ω terminal resistors to be connected at both ends of the bus (physical head and tail), and shielded twisted pair cables are recommended for long distances (>100 meters).

In the isolated SKU: 4COM/6COM versions, some serial ports are equipped with 2.5KV isolation, which is suitable for connecting field devices with high voltage or large ground potential difference.

4.2 Isolated Digital I/O (only 4COM/6COM SKUs)

Provide 8 isolated DI channels and 8 isolated DO channels, with an isolation voltage of 2.5KV (optocoupler isolation).

DI electrical parameters:

Logic low (0): 0~1V

Logic high (1): 10~30V

Built in input resistor, can be directly connected to industrial sensors (PNP/NPN should pay attention to common ground).

DO electrical parameters:

Power supply voltage: 5-30V DC (externally provided)

Current injection: 500mA/channel (continuous), suitable for driving small relays, solenoid valves, or indicator lights.

Internally equipped with a flyback diode, when driving inductive loads (relay coils), the positive terminal of the external power supply needs to be connected to the VDD pin to form a flyback circuit and protect the MOSFET.

Typical application circuit of DO: The manual provides a reference circuit diagram - the external power supply is connected to the DO output terminal through the load (relay), and the internal MOSFET of DO conducts to form a circuit, and the load is powered on.

4.3 M.2 AFM Expansion Interface

Internally provides AFM (Additional Function Module) interface, which leads to PCIe, USB 2.0, SMBus, and LPC buses for customized functional board development (such as additional serial ports, CAN, dedicated protocol conversion, etc.). This provides ODM customers with extremely high flexibility.

BIOS Deep Configuration Guide

Enter BIOS: Press the Del key during power on POST.

5.1 Main (Main Menu)

Display read-only information such as BIOS version, CPU model, frequency, memory capacity and frequency (e.g. 4800MHz), PCH SKU, etc. At the same time, the system time/date can be set.

5.2 Advanced Core Settings

CPU Configuration:

Active Efficiency cores: can reduce the number of active energy efficiency cores (All/3/2/1) to lower power consumption (suitable for low load scenarios).

Intel SpeedStep/Turbo Mode: Enable dynamic frequency adjustment (default enabled); Turbo Mode can improve burst performance.

Intel Speed Shift: Hardware controlled P-state to improve response speed (enabled by default).

Intel Virtualization Technology/VT-d: Enable hardware virtualization (default enabled) for containers or virtual machines.

C-state: Enable CPU power-saving state (disabled by default, recommended to keep disabled to avoid real-time fluctuations).

Power Management:

Enable Hibernation: Enable S4 hibernation (default enabled).

ACPI Sleep State: Select the highest sleep state (default S3 Suspend to RAM).

State After G3: Configure the behavior after AC power failure recovery - S0 (automatic startup), S5 (keep shutdown). S0 is usually chosen for industrial sites.

Hardware Monitor:

Real time display of motherboard temperature and fan speed.

Support for SMART FAN IV: Four temperature points can be set to correspond to different PWM duty cycles, achieving on-demand speed regulation.

BIOS Watchdog Timer:

BIOS POST Watchdog: can be set to disabled, second mode, or minute mode. If the BIOS self-test freezes, it will automatically reset after timeout to prevent the device from waiting indefinitely.

Onboard Device Configuration:

COM1/COM2 Mode Control: Independently select RS-232/RS-422/RS-485.

LAN # 1/# 2: Network ports can be disabled (for security isolation or power saving).

Serial Console Redirection:

Support redirecting BIOS POST and operating system console to COM port for headless debugging.

Configurable baud rate (default 115200), data bits, parity bits, stop bits, hardware flow control (RTS/CTS), and terminal type (VT100/ANSI, etc.).

TPM 2.0 Configuration:

Built in TPM security chip (Nuvoton), supporting enable/disable, PCR Bank management, and TPM Clear operation, used for disk encryption and secure boot.

Network Stack Configuration:

Enable UEFI network stack to support PXE/HTTP network boot (disabled by default).

5.3 Chipset

Memory Configuration: Display the RC version, frequency, and timing of the memory (such as 40-39-39-77).

PCI Express Configuration: It can control the enable/disable of each Root Port separately and configure PCIe Speed (Auto/Gen1/Gen2/Gen3) for compatibility with older expansion cards.

SATA Configuration: Enable/disable SATA controllers and ports.

USB Configuration: Supports disabling USB by physical port (Select Per Pin) for securely restricting external storage access.

Security Configuration: BIOS Lock (default enabled) protects flash memory from malicious writes.

5.4 Security & Boot

Administrator/User Password: Set BIOS password to prevent unauthorized modification.

Secure Boot: Supports secure boot (requires Enroll Platform Key).

Boot Configuration: Can set startup delay (default 1 second), NumLock status, Quiet Boot (enable display of OEM logo, disable display of POST diagnostic information), Fast Boot (skip some self-test acceleration startup).

Boot Option Priorities: Supports up to 10 boot options, allowing for precise control of boot sequence (hard drive/NVME/CD/USB/network, etc.).


Isolation DIO programming and debugging (4COM/6COM SKU)

6.1 DIO Driver Installation Process

Download the DIO toolkit from the ADLINK official website.

Installation driver: MXE_SMBus_Sriver.exe (SMBus bus driver, used to access DIO registers).

Enter the DIO_CnsoleAPP_Sin directory and run DIO_CnsoleAPP.exe in administrator mode - this tool is used for command-line reading and writing of DI/DO status.

Enter the StartDIO_Sin directory and run StartDIO.exe in administrator mode - Start the DIO service background process.

6.2 API Programming (C/C++)

If customized development is required, it should include:

Header file: Matrix_dio. h

Static library: Matrix_dio64.lib

Runtime dynamic library: Matrix_dio64.dll

Typical DIO operation (function definition):

GPIOInitialize: Initialize DIO resources.

GPI-Read(): Read 8 isolated DI states (return bit mask).

GPOWrite(): Write 8 isolated DO states (bit mask controls on/off of each channel).

6.3 Application Scenario Examples

DI input: Connect limit switches, buttons, or photoelectric sensors (10-30V) to read the status for PLC or upper computer decision-making.

DO output: Drive intermediate relay (external 5-30V power supply, single channel 500mA), control motor start stop or indicator light.

Debugging reminder: During the first debugging, manually read and write each channel using DIO_CnsoleAPP.exe to confirm that the hardware wiring is correct. Special attention must be paid to the external power supply (VDD) of the DO, otherwise the MOSFET cannot drive the load normally (the freewheeling diode also needs VDD to participate).


Key points for on-site troubleshooting and maintenance

7.1 System cannot start

Check if the DC input voltage is within the range of 12-24V and if the polarity is correct (positive pole of the center pin).

Observe the Power LED (blue) on the front panel - constantly on indicates normal operation, flashing indicates sleep mode, and off indicates no power supply.

If the power supply is normal but there is no display, try connecting the monitor through HDMI or DP interface; If there is still no display, try clearing the CMOS (disconnect the battery or short-circuit the RTC jumper, but check the specific location).

7.2 M.2 module not recognized

Confirm that the module is inserted into the correct slot (M-Key only NVMe, B-Key only USB, E-Key supports WiFi).

Check if the installation of the heat sink is too tight, causing deformation or poor contact of the module (it should be tightened appropriately).

Enter BIOS to check if the corresponding PCIe port is disabled.

7.3 Serial Communication Abnormalities

Enter BIOS to confirm that the COM mode (232/422/485) matches the actual wiring.

Use serial debugging tools (such as Putty or Tera Term) for self loop testing (RS-232 short circuit Pin2-Pin3).

Check the terminal resistance and shielding layer grounding of RS-485, and reduce the baud rate for long-distance communication (such as from 115200 to 9600).

7.4 DIO No Response

Confirm that the SKU includes DIO functionality (4COM/6COM or 4LAN version - note that the DIO definition is different for 4LAN version, please refer to Appendix B).

Check if StartDIO.exe is running in administrator mode; Is the SMBus driver installed.

Verify that the external DO power supply (VDD) is connected (5-30V) and that the common terminal (GND) is properly connected.

7.5 Overheating and Frequency Reduction

Check if the heat sink is tightly attached to the CPU (with no damage to the thermal pad) and if the bottom clearance of the device is sufficient.

If the ambient temperature is above 60 ° C, it is necessary to consider adding an external auxiliary fan or replacing it with a higher TDP cooling solution (contact ADLINK technical support).


Environmental Compliance and Safety Warning

Working temperature: -20 ° C~60 ° C (DC power supply); If using an AC-DC adapter, the maximum temperature is 50 ° C.

Anti vibration and anti impact: 3 Grms vibration (5-500Hz), 30G half sine impact (11ms), meeting industrial grade reliability requirements.

EMC certification: CE&FCC Class B, meets industrial radiation standards.

Safety certification: CB, UL/cUL, power supply must comply with IEC/UL LPS/SELV requirements.

Lithium battery warning: The built-in RTC battery (BR2032) must be replaced with the same model and disposed of as WEEE.

California Proposition 65: Products containing lead, cadmium, and other substances require end-users to comply with local hazardous substance handling regulations.

  • Metso Valmet PEFT A413792 - Power Supply Module for Automation Systems
  • Valmet ABTU M2512201 - Analog Binary Termination Unit Module
  • Valmet ABMB MT036 PCB Card - Auxiliary Backplane Motherboard
  • Valmet A413345 FPUS Battery Backup Unit - Standby Power Module
  • Valmet A413060 DMU Rev 04 - Drive Monitor Unit Board
  • Valmet BOR82 A413292 - Binary Output Relay Module
  • Valmet A413383 Ver.04 ESW - Electronic Switching Module Board
  • Valmet Neles A415579 Valve Controller
  • Metso Valmet A413381 ESW Drive Board
  • Valmet ABTU Module 545266-2A 2-545264-2B - Analog Binary Termination Unit
  • Valmet ABMB MT838 PCB - Backplane Bus Mother Board
  • Valmet LEV-EL PG4 N1 H2S Sensor - 600mbar Gas Detector
  • Valmet ABMB MT940 PCB - Analogue Bus Mother Board Backplane
  • Valmet VAT65425921A MT241 PCB Board
  • Valmet A413310 VPU Power Unit - 230VAC 1.5A Automation Supply
  • Valmet Metso IOP303 Input Module 181504 - 32-Channel Digital Input
  • Valmet A413060 DMU Rev 07 - Data Management Unit
  • Valmet M851220 M1 PCB Card - Process Automation Interface Board
  • Valmet A413042 Ver.06 CPU
  • Valmet A413200-01 AIU 8 Analog Input Module
  • Basler DECS-250-CGCM-LN2SA1C Digital Excitation Control System
  • Valmet Automation PLC Module A413171
  • Valmet Automation 542852-3A Rack-Mount Cross Connect Panel
  • Valmet Marine Damatic M851565 Main Keyboard
  • Valmet TIU 6 Printed Circuit Board A413110
  • Metso Valmet U4440253V1.1 RMI CPU 300
  • Metso Valmet A413016 Ver.12 NCU2
  • Valmet M851565 Damatic Keyboard
  • Valmet ATB16-4 16 Channel Relay Card
  • Valmet Metso A413331 SPU Power Supply
  • Valmet PUD 10B Automation Control Rack
  • Valmet MT917 ABMB DMU PCB I/O Module
  • Valmet M851565 Damatic Keyboard Mkb2
  • Valmet EDS-518A-MM-SC Ethernet Gateway
  • Valmet 542836-6A PCB Card
  • Valmet ATB16-4/2 Terminal Board 9144047
  • Valmet ATB16-4 Controller Board 0-50°C 4-20mA Analog Output
  • Valmet 542852-3A Slot Rack Chassis Module
  • Valmet A413026 Ver.M1 FBC Board
  • Valmet IQ Basis Weight SH Sending Assembly A418081
  • Valmet PMB 2R Monolithic Backplane 8-Slot PCB 542821-5A and -5B
  • Valmet ATB16-4 16-Channel Relay Card Controller Board 22195028
  • Valmet Diff-EL SL6NK227SF0 Pressure Transmitter 0-380 mBar
  • Valmet A413110 TIU6 Board Ver.M1
  • Neles Automation A413278 Control Module
  • Valmet BCUTB Terminal Module 10101006 11091002
  • Valmet Senso 160 Measuring Station Display 160.2
  • Valmet AIU 1A Analog Input Unit M851245
  • Valmet IQ Web Caliper Sensor A420734
  • Valmet M851040/M8510401 Memory Board
  • Valmet AN35S1MC02RA Valve
  • Valmet M851121 M2 Cross Connect Panel
  • Valmet AIU-8 Simulator Board 421522-1A
  • Metso BIU 82 D200533 Binary Input Unit
  • Valmet M851121 M2 Module Rack
  • Valmet A413383 PC Board Module
  • Valmet N0542 NO54 ABMB PCB - 545200-3A Board
  • Valmet Metso IOP304 Input Module 181503
  • Valmet PDP601 Distributed Processing Unit 181585
  • Valmet A413084 CPU Board - Processor Module for Automation Systems
  • Valmet AIU 16T Analog Input Module M8512081 M1
  • Valmet AIU 16 Analog Input Module 545100-3A and 545100-3B
  • Metso Valmet BIU4 A413146 Binary Input Unit
  • Valmet AIU-8 Simulateur Board 421522-1a Analog Simulator
  • Valmet BIU8A Binary Input Unit 542803-3B M851222 M1
  • Valmet IQ Web Color DH Photoelectric Sensor A418182 2.04
  • Valmet A413200 AIU-8 Simulator Board 191151 421522-1A
  • Valmet Automation SCU M851006 System Control Unit Module
  • Valmet 857565/851565 Damatic Keyboard IP40 5V Operator Interface
  • Valmet A413077 FBC2 Module Rev 06 Field Bus Controller
  • Valmet DMU 2 PCB Module 545142-3A DM Data Management Unit
  • Valmet AIU16T PCB Card M851208 Analog Input Module
  • Valmet A413181 PLU Board
  • Valmet m851006 SCU Module
  • Valmet Metso 181226 Digital Input Module
  • Valmet AIU16T Analog Input Module - 16-Channel 65421466-2B MT924 V1.3
  • Valmet WIN3136875 Slide Clutch
  • Metso Valmet TIU61 A413111 Temperature Input Unit
  • Valmet MC12S Slitter Motor
  • Valmet A413139 AOH4 Board - Analog Output High Module
  • Valmet A409001 BIU85 Board
  • Valmet A413063 DMU Board
  • Valmet A413325 IPU I/O Power Unit
  • Valmet M851004 M2 CPU Module
  • Valmet IOP345 Digital Input Module
  • Metso Valmet A413215 Communication Board
  • Valmet DIFF-EL 80 M1 Transmitter
  • Valmet A413001 CPU Module
  • Valmet M899520 TDC-2 Module
  • Valmet A409001 BIU85 Board
  • Metso Valmet A413005 CPU Module
  • VALMET PUD 10 B Process Automation Rack with CPU SCU Module
  • Valmet A413091 GDU1 Board
  • VALMET M851006 M2 SCU Module
  • Lyngso Valmet Marine 990.896.000 Position Loop Card
  • Valmet Cooking Liquor Measurement 3417H
  • VALMET ABMB MT831 PCB Card
  • Valmet Automation A413325 IPU I/O Power Unit
  • Valmet Metso Consistency Transmitter Smart Pulp M2
  • VALMET METSO A413274 Connection Module
  • VALMET PI33S1KSA02RSA-ELI26 Switch
  • VALMET ND9103HN-CE07-K05 Intelligent Valve Controller
  • VALMET PMB 2R 16 Slot Backplane PCB Card
  • NELES VALMET A413135 AOU 4 Output Module
  • Metso Valmet A413345 FPU Power Unit
  • VALMET A413171 PIC Module
  • VALMET A413620 Repeater Module
  • Valmet M851521 Memory Card
  • Valmet DIFF-EL 140 M1 Transmitter
  • Valmet A413064 DMU Module
  • Valmet IOP371 I/O Bus Extender Module
  • Valmet Cooking Liquor Measurement 3400 Model 3417H
  • Metso Valmet A413043 CPU Module – Industrial Processor
  • Valmet BIU4 M851221 Binary Input Module
  • Valmet PMB 1S CPU SCU Rack Module
  • Valmet A413248 Controller Module
  • Valmet PDP601 Distributed Processing Unit
  • VALMET M851004 M2 CPU Printed Circuit Board Module
  • Metso Valmet A413045 Ver.05 CPU Module
  • Valmet A413181 Ver.05 PLU1 Board
  • Lyngso Valmet ATB16 Controller Board
  • VALMET AIU 16 Analog Input Unit 545100-3A/3B
  • VALMET PUD 10 B Power Supply PCB Rack Module
  • Valmet MS-50V/120V Bearing Unit
  • Valmet PDP603 Distributed Processing Unit – DPU Module
  • Valmet A413110 TIU Board – Terminal Interface Unit
  • Valmet S420154 I/O Backplane PCB – Printed Circuit Board
  • Valmet A413173 Industrial Control Module