Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

ADLINK NEON-1000-MDX Smart Camera Deployment and Trigger Configuration

F: | Au:FANS | DA:2026-08-06 | 313 Br: | 🔊 点击朗读正文 ❚❚ | Share:

ADLINK NEON-1000-MDX Smart Camera Deployment and Trigger Configuration

Introduction: Integration Pain Points of Edge AI Vision Systems

In industrial testing, intelligent security, and embedded AI applications, the traditional combination of "camera+industrial computer" not only occupies space, but also needs to deal with complex cable connections and compatibility issues. The ADLINK NEON-1000-MDX series highly integrates the Intel Atom E3930 processor, Movidius Myriad X VPU, Basler image sensor, and FPGA I/O to create an intelligent camera designed specifically for deep learning inference. However, engineers often face specific challenges such as trigger signal configuration, lens selection, power topology, and software environment setup during actual deployment. This article will start with hardware interface parsing, triggering and I/O wiring, image acquisition, and OpenVINO inference examples to systematically outline the engineering implementation steps of NEON-1000-MDX, helping the project team quickly achieve a leap from prototype to mass production.


Product Model and Sensor Selection Guide

NEON-1000-MDX offers four models, with the core difference being the image sensor parameters:

Model Resolution Pixel Size Shutter Type Frame Rate Target Surface

NEON-101B-MDX 1280 × 960 (1.2M) Global Shutter 54 fps 1/3 "

NEON-102B-MDX 1600 × 1200 (1.9M) Global Shutter 60 fps 1/1.8 "

NEON-103B-MDX 1920 × 1080 (2M) Roller Shutter 30 fps 1/3.7 "

NEON-104B-MDX 2592 × 1944 (5M) Roller Shutter 14 fps 1/2.5 "

All models are color sensors based on Basler daA series modules and C-mount lens interfaces. Key selection points:

Moving object detection: Prioritize global shutter speed (101B/102B) to avoid the jelly effect caused by rolling shutter speed.

High resolution details: Choose 104B (5M), but the frame rate is only 14fps, suitable for static detection or low-speed motion.

Universal Balance: 103B provides 1080p 30fps, suitable for most monitoring and defect detection scenarios.


Detailed explanation of hardware interfaces and engineering wiring

The NEON-1000-MDX adopts a vertical I/O design, with all interfaces distributed on three sides, greatly simplifying installation and wiring.

3.1 Bottom interface (core connection)

DC Jack (12V/≥ 30W): Comes with a dedicated adapter (P/N 31-62156-1000-A0). It is recommended to use only official accessories to avoid insufficient power.

USB Type-C: Supports DisplayPort( 1080p@30fps )It is compatible with USB 3.0 and can also be used as a backup power input (via USB PD). When powered solely by DC Jack, Type-C can provide up to 3W (5V/0.6A) of power to the outside world for connecting small USB hubs or keyboards and mice. If the power consumption of the peripheral exceeds 3W, a Hub with independent power supply must be used.

Gigabit Ethernet: Standard RJ45, used for image data upload and remote control.

15 pin D-sub I/O: This is the most critical interface in engineering, including UART (Tx/Rx/GND), 4 digital inputs (DI0~DI3, where DI0 can be programmed as an external trigger), and 4 digital outputs (DO0~DO3, where DO0 can be programmed as a flash synchronous output). All DI/DO are grounded (DI/O GND), with a DI high level threshold of 2-5V (0-5V input range), and DO as an open drain output (requiring an external pull-up resistor, maximum current of 100mA, withstand voltage of 3.3-30V).

Typical application wiring:

Hardware trigger: Connect the external photoelectric sensor or encoder signal (NPN/PNP, level converted) to Pin11 (DI0/Trigger), set the camera to external trigger mode, and collect one frame for each falling or rising edge (configurable) received.

Flashlight control: Connect DO0 (Pin3) to the trigger terminal of the LED driver, and output synchronous pulses in conjunction with the camera exposure timing to achieve "capture and fill light".

3.2 Top and Front Interface

Power LED (green): It lights up when powered on.

System status LED (orange): Flashes at startup and stays on after the system is functioning properly, making it easy to quickly determine if the system is stuck.

MicroSD card slot: supports extended storage (ADLINK offers 32GB optional), which can be used to store model files and collect data.

Micro-USB(Type-A):USB 2.0 OTG, Used for external mouse and keyboard connection or firmware upgrade (requires specific operations).

C-mount lens mount: Transfer Ring is pre installed, only NEON-102B requires a washer to ensure the rear focal length.

Power topology and heat dissipation precautions

NEON-1000-MDX supports two power supply modes:

Independent power supply: DC Jack connected to 12V adapter, Type-C is only used for video output and USB peripherals (power consumption limited).

Combination power supply: Use ADLINK dedicated Type-C Hub (P/N 92-99090-1010) to provide power, video output, and USB expansion simultaneously, reducing cables.

Key thermal management: The overall power consumption is less than 30W, but the built-in VPU (Myriad X) and CPU generate significant heat during high load inference. The manual stipulates that:

When using Type-C Hub for power supply, the upper limit of ambient temperature is 35 ℃;

  • SIGMATEK ICA111 Module
  • SIGMATEK MDD 121-1 Drive Axis Module
  • SIGMATEK M5V121 12-300-121 Krauss Maffei M5 Display Unit
  • SIGMATEK CTMS 020 CD Technology Module 12-250-011
  • SIGMATEK PCT122 Touch Panel
  • Stöger MCS4100 SIGMATEK Control Module
  • SIGMATEK Krauss Maffei M5 Keyboard Unit M5K902 12-310-902
  • SIGMATEK SD310-2 Servo Drive Module
  • SIGMATEK CM5V020 CD Wiring Circuit Module
  • SIGMATEK ENGEL Robot Drive M3 02220-8748
  • Sigmatek CFF011 Drive Module
  • Sigmatek DCP642 DIAS Central Unit
  • Sigmatek SDM081 S-DIAS Safety Module
  • Sigmatek C-IPC 01-450-024 Industrial PC
  • Sigmatek Kompakt NC4 Control Module
  • Sigmatek VI021 VARAN Interface Module
  • Sigmatek Engel RD-M6-2 Robot Drive
  • Sigmatek CNC031 Positioning Module
  • Sigmatek TO161 Digital Output Module
  • Sigmatek CCL912 CPU PSU Module
  • Sigmatek ETV0821 Operator Terminal
  • SIGMATEK ET 261 Operator Terminal
  • SIGMATEK CP731-K Control Module 20-004-731-K
  • SIGMATEK ETEK Motherboard 12-250-021-K CM5V020
  • Sigmatek DEZ 181 DIAS Input Output Module
  • Sigmatek IPC111-D Industrial PC
  • SIGMATEK AKM54L-ANC2GBB0 Servomotor with Gearhead
  • SIGMATEK CTMS020 CM5V020 CNC Controller
  • DEMAG ERGOTECH 061 381 66 Sigmatek Control Unit
  • Sigmatek DAI 883 Module
  • Sigmatek ETV1521 Control Panel Installation Terminal
  • Sigmatek 9802.289.01 Board Control TA71 Display
  • Wittmann Sigmatek EU-252 proDrive W4 Servo Drive
  • Sigmatek CDM166 C-DIAS Module
  • Sigmatek DCP082 DIAS Central Unit
  • Sigmatek CCP081 C-DIAS Processor Module
  • Sigmatek MD111-1 Drive Module
  • Sigmatek ETV0821 Operator Terminal
  • Sigmatek ISE021 Interface Module
  • Sigmatek DCC080L Slide Control Module
  • Sigmatek AI075 Analog Input Module
  • SIGMATEK TO161 20-007-161 Module
  • SIGMATEK CIC011 Module
  • SIGMATEK AE0000318502 Hand Terminal Pendant
  • Sigmatek Krauss Maffei PC323-K Control Unit
  • Sigmatek Krauss Maffei PC321-K Control Cabinet PC
  • SIGMATEK CIV521 Control Module
  • SIGMATEK C-IPC-171 Industrial PC
  • SIGMATEK MDP101-L DIAS Drive Network Module
  • Sigmatek Krauss Maffei PC323-K Control Cabinet PC
  • SIGMATEK CRCH081 C-SLIDES Temperature Module
  • Sigmatek PC301-E6 Industrial PC SSD
  • Sigmatek SDI101 S-SLIDES Safety Input Module
  • Sigmatek CIV521 VARAN Control Module
  • Kollmorgen Sigmatek AKM42G-ANCNGBB0 Servo Motor
  • Sigmatek PC 521 Process Controller
  • Sigmatek Geode LX800 12-780-012 Industrial PC
  • Sigmatek STO081 S-DIAS Safety Output Module
  • Sigmatek SCP111 S-DIAS Safety CPU Module
  • Sigmatek CDI161 Industrial I O Module
  • Sigmatek Wiring Board V2 DIAS 05-250-023
  • Sigmatek CP102 20-004-102 S-DIAS CPU Module
  • SIGMATEK SLIDES CNC 115 Module
  • SIGMATEK DCC080 05-700-080-2 Control Module
  • SIGMATEK MDD 121 Drive Axis Module
  • SIGMATEK CIO011 C-DIAS Multi I/O Module
  • SIGMATEK CIV512 Servo Drive
  • SIGMATEK CM5V020 12-250-021-K Wiring Module
  • SIGMATEK CIO011 12-013-011 Multi I/O Module
  • SIGMATEK 01-450-031 C-IPC Industrial Computer
  • SIGMATEK AKM24D-ANBNGBB0 Servo Motor
  • DEMAG NC4 LP0001289.03 Control Module
  • Sigmatek ETEK Industrial PC C-IPC with Option Module
  • Sigmatek AO081 20-010-081 Analog Output Module
  • Sigmatek CNC 031 Positioning Module
  • Sigmatek CP731-K 20-004-731-K CPU Module
  • Sigmatek MDD 3320-JR-A Drive Module
  • Sigmatek PM Servo Motor AKM52K-ANC2GBB0
  • Sigmatek MDP 101 09-403-101 Power Module
  • Sigmatek S-SLIDES AO046 Analog Output Module
  • Sigmatek ICA111 20-102-111 Interface Module
  • SIGMATEK DCP646 Module 05-004-646
  • SIGMATEK SDI101 Digital Input Module 20-891-101
  • SIGMATEK S3330-2 Directional Gyro Altitude Instrument
  • SIGMATEK MDP102-1 Controller
  • SIGMATEK SMT 01-230-321 Touch Screen
  • SIGMATEK Krauss Maffei PC301-K 01-310-301-K Industrial PC with 8GB SSD
  • SIGMATEK ETT731 01-230-731 Built-in Touch Terminal
  • SIGMATEK CIV521 Control Module
  • SIGMATEK DME 128 Module 05-005-128
  • SIGMATEK SCP111-S 20-890-111-S S-DIAS Safety CPU Module
  • Sigmatek SCP111 S-DIAS Safety CPU
  • Sigmatek CRIF081 Interface Module
  • Sigmatek CP112-1 S-DIAS CPU Module
  • Sigmatek MDD121-L DIAS Drive Axis Module
  • Sigmatek C-IPC 01-450-024 Industrial PC
  • Sigmatek SDD215-23 SLIDES Drive
  • Sigmatek DPS001 DIAS System Components
  • Sigma-Tek 4000B-30 Directional Gyro
  • Sigmatek SDD340-46 SDD Series Drive
  • Sigmatek CEZ221 Euromap67 I O Module
  • SIGMATEK VI021 Interface Module
  • SIGMATEK CP731-K Control Module
  • SIGMATEK Krauss Maffei PC321-K Industrial PC
  • SIGMATEK ET322 Operator Terminal
  • SIGMATEK CP102 Control Module 24VDC
  • SIGMATEK SRO021 Relay Output Module
  • SIGMATEK DCP640 DIAS Central Unit
  • SIGMATEK MDD 121 Drive Axis Module
  • SIGMATEK AI043 Analog Input Module
  • ENOTEC OXITEC 5000 SME-53310000 Oxygen Analyzer
  • SIGMATEK Krauss Maffei PC301-K 01-310-301-K Industrial PC
  • SIGMATEK SDD310-23 VARAN Servo Drive
  • SIGMATEK CDM 163 and CIC 011 C-DIAS Input Modules
  • SIGMATEK MDP 101-1 Power Module
  • SIGMATEK CM5V020 Wiring Circuit with CTMS020
  • SIGMATEK CCP521 C-DIAS Processor Module
  • SIGMATEK MDP 101-K Power Module
  • SIGMATEK ETEK C-IPC 733MHz VIA Eden 7000
  • SIGMATEK DCP 643 DIAS PLC CPU Module
  • SIGMATEK TAE121 12-200-121 Operator Terminal
  • Sigmatek TMS012-T Injection Moulding Technology Module
  • Sigmatek MDD 121-1 Controller
  • Sigmatek CDM167 Module
  • Sigmatek DCP082 DIAS Central Unit
  • Sigmatek ETT731 Built-In Terminal Touch
  • Sigmatek CCP521 C-DIAS Processor Module
  • Sigmatek Krauss Maffei PC301-K Control Cabinet PC