ADVANTEST R3860 RF Component Analyzer

F: | Au:YIMING | DA:2024-09-10 | 1198 Br: | 🔊 点击朗读正文 ❚❚ ▶ | Share:

ADVANTEST R3860 RF Component Analyzer

OVERVIEW

The R3860 RF Component Analyzer is most suitable for evaluating the performance of RF components in the frequency band from 300 kHz to 8 GHz. The R3860, which has functions for measuring multiport devices, such as balanced input/output devices and front-end modules. ADVANTEST has been able to attain the world’s fastest sweep of 10 µs/point, which is a tenfold increase over earlier ADVANTEST products. In addition, it is possible to greatly improve production throughput for mobile terminal components by using the removable panel, which can be installed at a location convenient for the operator, as a tool built into automatic inspection machines.

High-speed, High-accuracy Measurements Using the R3860 RF Component Analyzer

The R3860 is a component analyzer based on a new design concept. Because the R3860’s measurement accuracy is at least three times greater than previous ADVANTEST products— the result of the low-noise design in the receiving section—high-speed sweeps are now possible with an extended resolution bandwidth. At the same level of accuracy as previous ADVANTEST products, your testing costs are significantly reduced.

● Frequency range: 300 kHz to 8 GHz 

● Sweep time: 10 µs/point 

● Resolution bandwidth: 10 Hz to 400 kHz 

● Trace noise: 0.005 dBrms (typical) @ RBW of 100 kHz

Easy-to-View Display Function and Simple Operation

Excellent Flexibility and Visibility

The R3860 is provided with a touch screen function that is installed in a large, 12.1-inch SVGA color LCD display. Up to 16 split windows and up to 32 measured traces can be displayed, giving you the capability to combine S-parameter and format. When adjusting the balanced type of multi-port devices and dielectric duplexer with many traces, and the marker function, operator efficiency improves because of the excellent visibility provided by the high-resolution, largescreen SVGA display.

Eight Independent Channels

The use of the R3860 increase significantly when split windows (up to 16) and measurement traces (up to 32) are used together with eight independent channels. For example, the R3860 is ideal for measuring devices such as multiport devices, each of which requires a set of unique measurement conditions for each channel since a set of measurement conditions and calibration data can be set for each channel. Because many parameter types and measurement results can be observed at a glance, test throughput is dramatically improved.

Simple Operation

The R3860 can be operated either from the touch panel or with a mouse. Both capabilities are provided as standard. The R3860 is easy and simple to operate because measurement data, setting conditions, and other information are displayed on the display unit. Furthermore, you can change setting conditions on the touch panel via the Windows® GUI. These features make it possible for a new user of the R3860 to operate it easily.

Superior Calibration Function

Four-port calibration

Two types of calibration are provided: normalizer calibration which normalizes frequency characteristics only, and full calibration which corrects for impedance mismatch errors in addition to normalizing frequency characteristics. The R3860 performs full calibration appropriate for each of its four ports. The full calibration connection must always be used if low-loss balanced RF devices or multiport devices must be measured with a high degree of accuracy.

Automatic Calibration Kit (Option)

Calibration is always required before highaccuracy measurements are made. Automatic calibration kit enables the unit to obtain a set of stable and accurate calibration data, free of human error. The kit is especially useful for improving productivity because any operator can easily perform highly accurate error calibration. Measurement efficiency can also be improved with alarms generated by the verification function, which automatically and quickly checks whether error corrections are within the specified range, while it is being executed after automatic calibration has been completed.

Multiport Device Measurement

The following devices are available for three-port and four-port devices used in cellular phones in mobile telephone systems: duplexers, circulators, baluns, couplers, dual filters, and balanced input/output devices. In addition, antenna switch modules for five to 12 ports are available for multiband systems. Complexity of the S-parameter representing measurement paths in these multiport devices increase every year.

Per-port Architecture

The R3860 is compatible with up to 4 ports and is designed to simultaneously analyze the signal for each port. As a result, sweep and measurement times can be dramatically reduced. In addition, the combination of measurement paths for a multiport device can be optimized as needed for the purpose of each device.

Easy Display of Many S-parameters

The R3860 is equipped with a large 12.1-inch screen and eight independent channels, each of which can be individually calibrated with a unique set of calibration data. In addition, up to 16 split windows and up to 32 traces can be displayed. When a four-port device is used, all measurement results can be acquired at the same time by combining all 16 S-parameters with the format function. The format function is suitable for multiport devices that have many measurement paths.

  • National Instruments cRIO-9112 Chassis
  • National Instruments PXIe-1078 Chassis
  • National Instruments PCIe-6536 DIO Board
  • National Instruments NI-9425 Input Module
  • National Instruments PCI-5122 Digitizer Card
  • National Instruments 779072-01 Relay Module
  • National Instruments 783703-01 DAQ Module
  • National Instruments PXI-6515 Digital Module
  • National Instruments 781099-01 DAQ Device
  • National Instruments PXI-8183 PXI Controller
  • National Instruments sbRIO-9626 Single-Board RIO Controller
  • National Instruments PXIe-1435 Camera Link Frame Grabber
  • National Instruments NI 9237 Strain Bridge Input Module
  • National Instruments PXIe-4353 Thermocouple Input Module
  • National Instruments PCIe-6320 X Series DAQ Card
  • National Instruments NI 1454 Compact Vision System
  • National Instruments PCIe-6321 X Series DAQ Card
  • National Instruments PXIe-5172 PXI Oscilloscope Module
  • National Instruments cDAQ-9134 CompactDAQ Controller
  • National Instruments cRIO-9063 CompactRIO Controller
  • National Instruments PXI-4070 DMM Card
  • National Instruments cFP-BP-4 Backplane
  • National Instruments 779521-01 Bridge Module
  • National Instruments cDAQ-9172 Chassis
  • National Instruments NI 9236 Strain Module
  • National Instruments PXI-1042Q Chassis
  • National Instruments SCXI-1102 Input Module
  • National Instruments 776990-01 Input Module
  • National Instruments PXI-1045 PXI Chassis
  • National Instruments PCIe-6251 DAQ Device
  • National Instruments NI 9219 Universal Analog Input Module
  • National Instruments NI 9215 BNC Analog Input Module
  • National Instruments PXIe-6570 Digital Pattern Instrument
  • National Instruments NI-9477 Digital Output Module
  • National Instruments NI 9145 EtherCAT Chassis
  • National Instruments PCI-6521 Industrial Digital I/O Card
  • National Instruments NI 9239 BNC Voltage Input Module
  • National Instruments NI 9265 Current Output Module
  • National Instruments NI 9212 Thermocouple Input Module
  • National Instruments PXI-6229 Multifunction DAQ Module
  • National Instruments NI-9146 Chassis
  • National Instruments PXIe-5622 Digitizer
  • National Instruments PXI-6704 Output Module
  • National Instruments 782362-01 Input Module
  • National Instruments 779068-01 Digital Module
  • National Instruments 781063-01 Output Module
  • National Instruments PCI-7356 Motion Controller
  • National Instruments 779787-01 Input Module
  • National Instruments PXIe-1071 System
  • National Instruments NI 9219 Input Module
  • National Instruments NI 9214 Thermocouple Input Module
  • National Instruments PXIe-1085 18-Slot Chassis
  • National Instruments PCIe-6320 Multifunction DAQ Card
  • National Instruments USB-6211 Multifunction I/O Device
  • National Instruments USB-6341 X Series DAQ Device
  • National Instruments NI 9205 Analog Input Module
  • National Instruments NI 9149 8-Slot Chassis
  • National Instruments PXIe-2569 Relay Module
  • National Instruments NI 9230 Sound and Vibration Module
  • National Instruments cRIO-9047 CompactRIO Controller
  • National Instruments PCI-6534 Digital IO Card
  • National Instruments PXI-5122 Digitizer Module
  • National Instruments cDAQ-9188XT Chassis
  • National Instruments cDAQ-9184 Ethernet Chassis
  • National Instruments USB-6225 OEM DAQ Device
  • National Instruments NI 9205 Input Module
  • National Instruments NI 9207 Input Module
  • National Instruments NI-9862 CAN Module
  • National Instruments 781156-01 CAN Module
  • National Instruments FP-AO-200 Output Module
  • National Instruments NI 9264 Output Module
  • National Instruments IC-3173 Controller
  • National Instruments NI 9234 Vibration Module
  • National Instruments SMB-2163 DIO Accessory
  • National Instruments PXIe-1062Q DSA System
  • National Instruments USB-6289 DAQ Device
  • National Instruments NI 9233 Vibration Module
  • National Instruments PXIe-5840 VST
  • National Instruments PXI-1033 and PXI-6132 System
  • National Instruments GPIB-USB-HS+ Controller
  • National Instruments NI 9231 Sound and Vibration Module
  • National Instruments cRIO-9074 CompactRIO Controller
  • National Instruments 782536-01 DAQ Module
  • National Instruments 779781-01 DAQ Module
  • National Instruments PXIe-8388 MXI Express Controller
  • National Instruments SCXI-1520 Strain Bridge Module
  • National Instruments PCIe-6320 Multifunction DAQ Card
  • National Instruments NI 9234 Sound and Vibration Module
  • National Instruments USB-4431 Sound and Vibration Device
  • National Instruments NI 9227 Current Input Module
  • National Instruments PXI-1033 PXI Chassis
  • National Instruments NI 9213 Thermocouple Module
  • National Instruments PXI-1042 PXI Chassis
  • National Instruments PXI-6229 DAQ Card
  • National Instruments cRIO-9075 Controller
  • National Instruments PCI-6033E DAQ Card
  • National Instruments PCIe-6363 DAQ Card
  • National Instruments cDAQ-9174 Chassis
  • National Instruments PXIe-8880 PXI Controller
  • National Instruments NI 9242 Analog Input Module
  • National Instruments USB-6221 BNC DAQ Device
  • National Instruments NI 9220 Analog Input Module
  • National Instruments cRIO-9068 CompactRIO Controller
  • National Instruments PXI-4130 Source Measure Unit
  • National Instruments USB-6251 Multifunction DAQ Device
  • National Instruments PXI-8106 Embedded Controller
  • National Instruments USB-6218 Multifunction DAQ Device
  • National Instruments PCIe-1473R Camera Link Frame Grabber
  • National Instruments PXIe-4341 DSA Module
  • National Instruments PXI-8102 Embedded Controller
  • National Instruments cDAQ-9178 Chassis
  • National Instruments USB-6210 DAQ Device
  • National Instruments USB-6212 DAQ Device
  • National Instruments NI 9485 Relay Output Module
  • National Instruments NI 9208 Current Input Module
  • National Instruments PXIe-4141 SMU
  • National Instruments PCI-6154 DAQ Card
  • National Instruments cRIO-9038 Controller
  • National Instruments PCI-6133 DAQ Card
  • National Instruments LabVIEW RIO Kit 501684G
  • National Instruments PXIe-6396 Embedded Controller
  • National Instruments USB-8502 CAN Interface Device
  • National Instruments NI 9264 Spring Terminal Output Module
  • National Instruments NI 9213 Thermocouple Input Module
  • National Instruments NI-9205 Analog Input Module
  • National Instruments NI 9264 Analog Output Module
  • National Instruments USB-6212 Multifunction I/O Module
  • National Instruments PXI-4071 FlexDMM Multimeter Module