Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

BMCM AMS42/84 5B amplifier system

来源: | 作者:FAN | 发布时间 :2025-12-23 | 312 次浏览: | 🔊 Click to read aloud ❚❚ | Share:

BMCM AMS42/84 5B amplifier system

Amplifier technology at its best. Compact or 19 inch.

Get your amplifier technology wrapped up with the AMS42/84. Available in a robust aluminum housing as a mobile tabletop unit (AMS42) with skid-proof, tip-up feet or as a stationary version (AMS84) for 19'' rack systems.

Modular concept.

Equip individually. Be flexible.

The AMS device is equipped with cassettes, on which the required 5B measuring amplifiers are mounted. The variety of available 5B modules allows for the optimum adaptation of the AMS42/84 to any special measuring task.

Choose connector.

Mount 5B amplifier. Done.

The available plug-in cassettes have different connectors on the front panel. Depending on the sensor or signal to be connected, the suitable cassette can be chosen. The 5B module only has to be fixed on the cassette now and be integrated in the AMS.

Clearly safe.

Most of the 5B modules feature galvanic isolation of the channels from each other and from the data acquisition and control system. This perfectly protects the whole system against high potentials and interferences.

Well supplied.

The AMS42/84 is operated with 9-40V via an external power supply.

Connection to the DAQ system.

The amplifier outputs are available at a D-Sub37 female connector. They are connected to the input lines of a data acquisition system. Combining the AMS42/84 with a measuring card or DAQ system from bmcm makes a powerful measurement system.

Accessories. Just makes it easier.

To individually equip the AMS devices, various 5B modules and plug-in cassettes as well as other accessories (e.g. external power supply, carrying handle, connection cable) are provided.

Versions and options.

Something for everybody.

AMS42/84 versions with an integrated DAQ (USB, LAN) are also available. With the 8channel extension AMS-EXT8, the number of channels can optionally be increased to 16 (AMS42) or 32 (AMS84) at the maximum.



Installation

Assembly

a) Equip the AMS42/84 with the plug-in cassettes (see chapter 4.2) carrying the required 5B modules.

b) Carefully push the cassette along the guide bars of the relevant slot until the 7-pole pin connector of the cassette and the pins of the 5B module are plugged into the corresponding connectors on the AMS backplane.

c) If using the AMS42/84 with the option AMS-EXT8 (see chapter 4.4), the additional cassettes are mounted on the back of the device.

d) For a tight installation, fix the front panel at both ends with screws to the housing. Bridge unneeded slots by a blank panel (AMS-K-BLANK) to protect the device against outside influences.

e) If the AMS84 is mounted to a 19'' rack system, the relevant input wiring should be prepared first before attaching the device to the rack system with screws.

Software installation and start-up procedure

a) Connect your PC data acquisition system to the 37-pole D-Sub female.

b) Attach an external power unit to the 3-pole DIN coupling for 9-40V power supply (use a supply cable with a cross sectional area >1mm (>1 ~mm^{2}) ) and turn on the AMS42/84 by pressing the switch to "1" (ON) (see chapter 2.1 and 2.2).

c) Signals are connected at the specific female connector of the respective AMS cassette panel.

image.png

Connections / Assignments

All available connectors and operating elements of the AMS42/84 are accessible on the right-hand side of the device front.

Switch and LED

The AMS42/84 is turned on (press "1") and off (press "0") with the switch.

The green LED "ON" indicates the operation of the device.

Power supply "DC In"

The AMS device is supplied with power (9..40V) via the 3-pole DIN plug. A power supply unit ZU-PW70W (24V, 2.92A DC) is optionally available.

| Assignment | | n. c. | | ground (GND) | | 9-40V DC |

2.3 Analog channels

8 (AMS42) or 16 (AMS84) analog signals can be connected to the amplifier inputs available at the respective connectors of the cassette panels.

Their assignment is illustrated in the data sheet of the AMS-K-xxx cassettes. To connect a PC data acquisition system, these analog outputs are led out to the 37-pole D-Sub female.

| Pin | AssignmentAMS42 | AssignmentAMS84 | | 1..8 | Analog OUT 1..8 | Analog OUT 1..8 | | 9..16 | n. c. | Analog OUT 9..16 | | 17..19 | n. c. | n. c. | | 20..27 | analog ground (AGND) channel 1..8 | AGND channel 1..8 | | 28..35 | n. c. | AGND channel 9..16 | | 36..37 | n. c. | n. c. |

Depending on the application, the shield of the analog input cables can be applied to ground or 0V. Be sure to connect at one end of the cable only. Run the signal ground separately if possible. Lay input cable separately if possible.


AMS backplane

The AMS -backplane provides 8 slots for 5B modules and the AMS-K-xxx plug-in cassettes (see chapter 4.2) carrying the 5B modules. Two backplanes are integrated in the AMS84.

If the optional add-on AMS-EXT8 (see chapter 4.4) is used, eight (AMS42) or 16 (AMS84) slots each are available on the front and on the back of the device.

Ground-to-ground resistance

The ground-to-ground resistance is required when the output ground is not electrically connected with the power supply ground. If the jumper (see fig. above) on the analog backplane is closed, the output switches of the modules are switched through.

Module pin assignment

The pin assignment on the right shows the top view of the module backplane (see chapter 3).

The pin assignment corresponds to the 5B modules of Analog Devices®, BURR BROWN® etc. However, an additional 0EX pin has been introduced, which is particularly suitable for ungrounded shielding. This is a specific assignment of BMC Messsysteme GmbH. The 0EX pin is not connected in modules of other manufacturers.

Fuse

The fusing of the AMS backplane is effected on the backplane (see chapter 3) with one reversible semiconductor fuse. In case of overload, it turns of. To make the fuse work effectively again, first remove the cause for overload before disconnecting the power supply of the AMS42/84.

3.4 Connection for AMS cassettes

The cassettes are connected to the AMS backplane via 7-pole pin connectors, leading the input signals connected at the cassette panel to the backplane. The assignment of the 7-pole female connector on the board is illustrated in the figure on the right-hand side.


Supplementary products for AMS42/84

5B modules (MA series)

The 5B measuring amplifiers from bmcm allow for the professional signal adjustment to a data acquisition system.

The amplifier output is ±5V or 0..5V. Most of the modules are electrically isolating and provide sensor supply.

The following 5B modules from bmcm are available:

| Product | Description | | MA-UNI | universal amplifier with galvanic isolation for U, I, R, PT100, DMS, LVDT | | MA-UI | multi-range amplifier with galvanic isolation for U, I | | MA-U | voltage measuring amplifier with galvanic isolation, 50kHz bandwidth | | MA-FU | frequency/voltage converter with galvanic isolation | | MA-DFI | digital filter module with galvanic isolation, 60dB/oct. | | MA-FI | filter module with galvanic isolation, 30dB/oct. |

Plug-in cassettes (AMS-K series)

The amplifier system can be individually equipped with 8 (AMS42USB) or 16 (AMS84) plug-in cassettes.

Each cassette is equipped with the relevant 5B module and suitable input connector.

The suitable input connector on the front panel guarantees for the relevant connection to be available when exchanging the cassette.

The following cassettes are available:

| Product | Description | | AMS-K-BIN5 | cassette with panel and 5-pole Binder female connector (712 series) | | AMS-K-BLANK | blank panel | | AMS-K-BNC | cassette with front panel and BNC female connector | | AMS-K-CO5 | cassette with front panel and 5-pole terminal connector | | AMS-K-THK | cassette with front panel and thermocouple socket (type K) |

AMS-HANDLE, AMS-HANDLE2

For mobile use, the AMS42/84 can be equipped with a lateral, foldaway strap carrying handle (AMS-HANDLE) or with two stable metal handles at the housing frame (AMSHANDLE2).

AMS-EXT8

With the add-on option AMS-EXT8, 8 additional analog channels each are available for the AMS42/84 accessible at the back of the amplifier measurement system. The AMS42 can be extended to max. 16 channels, the AMS84 to max. 32. The analog outputs are accessible at a second D-Sub37 female with the same assignment as the D-Sub37 female of the AMS device (see chapter 2.3).



Important notes for using the AMS42/84

The device is only suitable for extra-low voltages - please observe the relevant regulations! For reasons relating to EMC, it must only be used in closed PC housings.

Only use an electrical isolated power supply unit (with CE).

Only use non-solvent detergents for cleaning. The product is designed to be maintenance-free.

For calibration purposes, the device must be returned to BMC Messsysteme GmbH.

Use shielded cables for reasons relating to CE. Connect the shield to ground at one end only. Close open inputs if possible.

When mounting the cassettes, a connection between power supply ground and chassis of the device is made via the module screw.

The device must not be used for safety-relevant tasks. With the use of the product, the customer becomes manufacturer by law and is therefore fully responsible for the proper installation and use of the product. In the case of improper use and/or unauthorized interference, our warranty ceases and any warranty claim is excluded.

Do not dispose of the product in the domestic waste or at any waste collection places. It has to be either duly disposed according to the WEEE directive or can be returned to bmcm at your own expense.


Technical data

(typical at 20°C, after 5min., +24V supply)

Electrical data

Power supply:+9..40V DC, ±5%, min 3W, max. 20W (depends on number of 5B modules used) at 3-pole DIN male

Galvanic isolation:depends on the 5B modules used

Max. permissible potentials:60V DC acc. to VDE

General data

Signal connection:different connectors (Phoenix, Binder, BNC, Thermo) on the front panels of the cassettes

CE standards:EN61000-6-1, EN61000-6-3, EN61010-1; for decl. of conformity (PDF)

ElektroG // ear registration:RoHS and WEEE compliant // WEEE Reg.-No. DE75472248

Protection:IP20

Temperature ranges:operating temp. -25..50 ° C, storage temp. -25..70 ° C

Relative humidity 0-90% (not condensing)

Dimensions (W x H x D):AMS42-USB: 23.5 x 13.2 x 25.6 cm 3 ; AMS84-USB: 48.3 x 13.2 x 25.6cm 3 (incl. mounting brackets)

Delivery:device, description

Warranty:2 years from date of purchase at bmcm, claims for damages resulting from improper use excluded

Available accessories

AMS-K-BIN5:cassette and front panel with 5-pole Binder socket (712 series)

AMS-K-BLANK:blank panel

AMS-K-BNC:cassette and front panel with BNC female

AMS-K-CO5:cassette and front panel with 5-pole terminal connector

AMS-K-THK:cassette and front panel with thermocouple socket (type K)

AMS-EXT8:extension of 8 extra channels (accessible on the back of the device)

Other accessories:desktop power supply ZU-PW70W (24V, 2.92A DC), 3-pole DIN female ZU3DIN,USB extension cable ZUKA-USB, carrying handles AMS-HANDLE, AMS-HANDLE2

image.png

  • GE IM 3100 D 1007722 Control Module
  • GE IM0146B Industrial Circuit Board
  • GE IM0059E0-10070 Interface Board
  • GE IM0094C Industrial Control Board
  • GE IC200PNS002-AB VersaMax PROFINET Scanner
  • GE F650BFBF1G0HI Feeder Protection Relay
  • GE TPR5616NRHC Protection Relay
  • GE D6P3KH Digital Protection Relay
  • GE F650BABF2G0HIS Feeder Protection Relay
  • GE F650BADF2G1HIR Feeder Protection Relay
  • GE F650BABF2G1HI6 Digital Bay Controller
  • GE Multilin 745-W2-P1-G1-H-I-A-R-E Transformer Protection Relay
  • GE 100BASE-T Industrial Ethernet Interface
  • GE Multilin 350-E-P1-S1-H-S-E-C-N-2E-D-H Feeder Protection System
  • GE F650MXCF1G1HI6 Bay Controller
  • GE MM300-GEHD2CAB Motor Management Relay
  • GE MMS35-621-1-00 Motor Management System
  • GE 100BASE-T Ethernet Communication Module
  • GE F650MFCF1G1HI6 Feeder Protection Relay
  • GE CK13BA300 Control Module
  • GE W2-P1-G1-H Industrial Control Unit
  • GE PIB315B Power Interface Board
  • GE 343L695VAGIRHC Multi-Function Relay
  • GE Multilin B90N05HKHF8NH6 Bus Differential Protection
  • GE ZX3SC0204N-930 Intelligent Control Module
  • GE PIB504 Process Interface Board
  • GE D20MX Remote Terminal Unit
  • GE T60UJ3HKHF8NH6 Transformer Protection Relay
  • GE ZG3SA02041-58S600X Motor Protection Relay
  • GE ZG3SA02041-58S Motor Protection Relay
  • ABB DSDX 452 L Remote Input Output Module
  • ABB RDCU-02C Drive Control Unit
  • ABB COMMANDER 350 Process Controller
  • ABB Tmax XT4S 250 Molded Case Circuit Breaker
  • DEIF MALLING 8027.90 Industrial Control Unit
  • DEIF DCP2-2410 Power Supply Module
  • DEIF FAS-2N Synchronizer
  • DEIF MALLING 827.54 Processor Module
  • DEIF DU-2/MKIII Display Unit
  • DEIF DRW-2 Reverse Power Relay
  • DEIF 827.4 Power Management Module
  • DEIF 1044220060F Mains Measurement Module
  • DEIF 1044220190G Remote Display Module
  • DEIF 1044220140C AGC 200 Display Module
  • DEIF BRW-1-NB Remote Display Unit
  • DEIF MALLING 827.52 Industrial Control Unit for Automation Systems
  • DEIF BRW-2 Industrial Relay Module for Control Systems
  • DEIF 1044220080D Power System Control Module Industrial Automation
  • DEIF 1044220100F Controller Module for Generator Control Systems
  • DEIF DU-300 Voltage Monitoring Relay Industrial Protection Unit
  • DEIF 1044220060F I/O Extension Module
  • DEIF 1044220150C Interface Module
  • DEIF GCU 100 Engine Control Unit
  • DEIF XDI144-DUAL Marine Indicator
  • DEIF 827.41 Multi-line 2 Processor Module
  • DEIF AGC 146 Automatic Genset Controller
  • DEIF 1044220080E MDR-2 Display Module
  • DEIF MDR-2 Multifunctional Digital Relay
  • DEIF 1044220070E PPU-3 Display Module
  • DEIF PPU-3 Paralleling and Protection Unit
  • Siemens 6SL3210-1SE21-8UA0 PM340 Power Module SINAMICS Drive System
  • Yaskawa JANCD-XCP01C-1 Servo Control Board with JANCD-XIF04-1 Network Interface
  • BRISTOL 396879-01-2 C Wave Micro PLC CPU with Ethernet Industrial Controller
  • OMRON SGDH-10DE-OY Servo Drive High Precision Industrial Motion Control Amplifier
  • OMRON FQM1-MMA22 PLC High Performance Motion Controller Module
  • Schneider PowerLogic P5F30 Protection Relay
  • ABB DSPC53 57310256BA/2 Processor PCB
  • ABB Jokab 2TLJ020070R1700 Eden Safety Sensor
  • Lenze HMI EL 105C 3351-1 2 Control Panel
  • Pilz PSEN op4-s-30-060/1 Safety Light Curtain Specs
  • Vacon NXI01055A2T0CSSA1A3AK00C6 AC Drive
  • Square D PowerLogic CM4250 Circuit Monitor
  • Siemens CPU314C-2PTP Simatic S7-300 PLC
  • Eaton E84BAN Communication Interface Module
  • Prosoft MVI56 PDP-MV1 Profibus Master Module
  • Kongsberg MEI 8100276 Multi I/O Interface Module Marine Control System
  • Kongsberg MD 22 TN Display Module Marine Control Display Unit
  • Kongsberg MSI 8100222 Multi Signal Interface Module Marine Control System
  • Kongsberg RDO-16 8100155 Digital Output Module Marine Control System
  • Kongsberg RAO-8 8100153 Analog Output Module Marine Control System
  • Kongsberg C2 8100182 Controller Module
  • Kongsberg dPSC 8100183 Digital Process Controller
  • Kongsberg SPBUS-HUB 600309 Process Bus Hub
  • Kongsberg Simrad BP413R 37960580 A PCB Card
  • Kongsberg RAi-10tc 8100161 Remote Analog Input
  • Kongsberg NL-290 KM-F Navigation Light Panel
  • Kongsberg RAI-16xe Remote Analog Input Module
  • Kongsberg dPSC 8100183 Dynamic Positioning Control Panel
  • Kongsberg NK-210 NU02 Control Panel
  • Kongsberg RAIC400 Remote Analog I/O Controller
  • Kongsberg Simrad SJS-01/02 Sonar Sensor Marine Detection System
  • Kongsberg RAo-8 Analog Output Module Marine Automation Control Module
  • Kongsberg MP 530 Operator Panel Unit Marine Control Interface System
  • Kongsberg PSO-P 8100334 Power Supply Unit Marine Automation Power Module
  • Kongsberg dPSC 8100183 Dynamic Positioning Controller Marine Control System
  • Kongsberg MP 8200 Processor Module
  • Kongsberg MP 8300 Multi Processor Board
  • Kongsberg MCU8625 Marine Control Unit
  • Kongsberg MP 5810 Multi Processor Board
  • Kongsberg DSU 001 Dual Slot Unit
  • Kongsberg RCU 510 Remote Control Unit
  • Kongsberg BS610 Battery Supply Unit
  • Kongsberg M410-10 Alarm Monitoring Panel
  • Kongsberg HMS 100 Hull Monitoring System
  • Honeywell TCF901 Gas Detector
  • Honeywell 9938R Relay Output Module Industrial Control Switching Module
  • Honeywell XL1000C1000 Building Automation Controller HVAC Control System
  • Honeywell S0762970 I/O Interface Module Industrial Automation Signal Module
  • Honeywell RM7850 Burner Control Module Industrial Flame Safeguard Controller
  • Honeywell IPC1100 Industrial Panel Computer Automation Control HMI System
  • Honeywell TDID72 Digital Input Module
  • Honeywell TCNT01 Control Processor Interface
  • Honeywell C300 Controller Process Automation
  • Honeywell 51304337-250 Redundancy Cable Assembly
  • Honeywell PAL 2053 Programmable Array Logic Board
  • Honeywell IOC2053 Input Output Card
  • Honeywell PAIH03 Analog Input Module
  • Honeywell IPC 621 Industrial Computer
  • Honeywell 05701-A-0301 Process Control Card
  • Honeywell 10302/2/1 Power Supply Module
  • Honeywell SPXCDALMTX4 Gas Detector Module Industrial Safety Monitoring Device
  • Honeywell PHAI01 Analog Input Module Industrial Automation Input Module
  • Honeywell 63AP3070 Pressure Transmitter Industrial Measurement Module
  • Honeywell P522AC Analog Controller Module Industrial Control System Component
  • Honeywell K2LCN-4 ControlNet Interface Module Industrial Communication Module
  • Honeywell M6184D1035 Proportioning Actuator
  • Honeywell PCF901 Pulse Control Interface Module
  • Honeywell 05701-A-0302 Gas Detection Control Card