Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

BMCM AMS42/84 5B amplifier system

F: | Au:FAN | DA:2025-12-23 | 742 Br: | 🔊 点击朗读正文 ❚❚ | Share:

BMCM AMS42/84 5B amplifier system

Amplifier technology at its best. Compact or 19 inch.

Get your amplifier technology wrapped up with the AMS42/84. Available in a robust aluminum housing as a mobile tabletop unit (AMS42) with skid-proof, tip-up feet or as a stationary version (AMS84) for 19'' rack systems.

Modular concept.

Equip individually. Be flexible.

The AMS device is equipped with cassettes, on which the required 5B measuring amplifiers are mounted. The variety of available 5B modules allows for the optimum adaptation of the AMS42/84 to any special measuring task.

Choose connector.

Mount 5B amplifier. Done.

The available plug-in cassettes have different connectors on the front panel. Depending on the sensor or signal to be connected, the suitable cassette can be chosen. The 5B module only has to be fixed on the cassette now and be integrated in the AMS.

Clearly safe.

Most of the 5B modules feature galvanic isolation of the channels from each other and from the data acquisition and control system. This perfectly protects the whole system against high potentials and interferences.

Well supplied.

The AMS42/84 is operated with 9-40V via an external power supply.

Connection to the DAQ system.

The amplifier outputs are available at a D-Sub37 female connector. They are connected to the input lines of a data acquisition system. Combining the AMS42/84 with a measuring card or DAQ system from bmcm makes a powerful measurement system.

Accessories. Just makes it easier.

To individually equip the AMS devices, various 5B modules and plug-in cassettes as well as other accessories (e.g. external power supply, carrying handle, connection cable) are provided.

Versions and options.

Something for everybody.

AMS42/84 versions with an integrated DAQ (USB, LAN) are also available. With the 8channel extension AMS-EXT8, the number of channels can optionally be increased to 16 (AMS42) or 32 (AMS84) at the maximum.



Installation

Assembly

a) Equip the AMS42/84 with the plug-in cassettes (see chapter 4.2) carrying the required 5B modules.

b) Carefully push the cassette along the guide bars of the relevant slot until the 7-pole pin connector of the cassette and the pins of the 5B module are plugged into the corresponding connectors on the AMS backplane.

c) If using the AMS42/84 with the option AMS-EXT8 (see chapter 4.4), the additional cassettes are mounted on the back of the device.

d) For a tight installation, fix the front panel at both ends with screws to the housing. Bridge unneeded slots by a blank panel (AMS-K-BLANK) to protect the device against outside influences.

e) If the AMS84 is mounted to a 19'' rack system, the relevant input wiring should be prepared first before attaching the device to the rack system with screws.

Software installation and start-up procedure

a) Connect your PC data acquisition system to the 37-pole D-Sub female.

b) Attach an external power unit to the 3-pole DIN coupling for 9-40V power supply (use a supply cable with a cross sectional area >1mm (>1 ~mm^{2}) ) and turn on the AMS42/84 by pressing the switch to "1" (ON) (see chapter 2.1 and 2.2).

c) Signals are connected at the specific female connector of the respective AMS cassette panel.

image.png

Connections / Assignments

All available connectors and operating elements of the AMS42/84 are accessible on the right-hand side of the device front.

Switch and LED

The AMS42/84 is turned on (press "1") and off (press "0") with the switch.

The green LED "ON" indicates the operation of the device.

Power supply "DC In"

The AMS device is supplied with power (9..40V) via the 3-pole DIN plug. A power supply unit ZU-PW70W (24V, 2.92A DC) is optionally available.

| Assignment | | n. c. | | ground (GND) | | 9-40V DC |

2.3 Analog channels

8 (AMS42) or 16 (AMS84) analog signals can be connected to the amplifier inputs available at the respective connectors of the cassette panels.

Their assignment is illustrated in the data sheet of the AMS-K-xxx cassettes. To connect a PC data acquisition system, these analog outputs are led out to the 37-pole D-Sub female.

| Pin | AssignmentAMS42 | AssignmentAMS84 | | 1..8 | Analog OUT 1..8 | Analog OUT 1..8 | | 9..16 | n. c. | Analog OUT 9..16 | | 17..19 | n. c. | n. c. | | 20..27 | analog ground (AGND) channel 1..8 | AGND channel 1..8 | | 28..35 | n. c. | AGND channel 9..16 | | 36..37 | n. c. | n. c. |

Depending on the application, the shield of the analog input cables can be applied to ground or 0V. Be sure to connect at one end of the cable only. Run the signal ground separately if possible. Lay input cable separately if possible.


AMS backplane

The AMS -backplane provides 8 slots for 5B modules and the AMS-K-xxx plug-in cassettes (see chapter 4.2) carrying the 5B modules. Two backplanes are integrated in the AMS84.

If the optional add-on AMS-EXT8 (see chapter 4.4) is used, eight (AMS42) or 16 (AMS84) slots each are available on the front and on the back of the device.

Ground-to-ground resistance

The ground-to-ground resistance is required when the output ground is not electrically connected with the power supply ground. If the jumper (see fig. above) on the analog backplane is closed, the output switches of the modules are switched through.

Module pin assignment

The pin assignment on the right shows the top view of the module backplane (see chapter 3).

The pin assignment corresponds to the 5B modules of Analog Devices®, BURR BROWN® etc. However, an additional 0EX pin has been introduced, which is particularly suitable for ungrounded shielding. This is a specific assignment of BMC Messsysteme GmbH. The 0EX pin is not connected in modules of other manufacturers.

Fuse

The fusing of the AMS backplane is effected on the backplane (see chapter 3) with one reversible semiconductor fuse. In case of overload, it turns of. To make the fuse work effectively again, first remove the cause for overload before disconnecting the power supply of the AMS42/84.

3.4 Connection for AMS cassettes

The cassettes are connected to the AMS backplane via 7-pole pin connectors, leading the input signals connected at the cassette panel to the backplane. The assignment of the 7-pole female connector on the board is illustrated in the figure on the right-hand side.


Supplementary products for AMS42/84

5B modules (MA series)

The 5B measuring amplifiers from bmcm allow for the professional signal adjustment to a data acquisition system.

The amplifier output is ±5V or 0..5V. Most of the modules are electrically isolating and provide sensor supply.

The following 5B modules from bmcm are available:

| Product | Description | | MA-UNI | universal amplifier with galvanic isolation for U, I, R, PT100, DMS, LVDT | | MA-UI | multi-range amplifier with galvanic isolation for U, I | | MA-U | voltage measuring amplifier with galvanic isolation, 50kHz bandwidth | | MA-FU | frequency/voltage converter with galvanic isolation | | MA-DFI | digital filter module with galvanic isolation, 60dB/oct. | | MA-FI | filter module with galvanic isolation, 30dB/oct. |

Plug-in cassettes (AMS-K series)

The amplifier system can be individually equipped with 8 (AMS42USB) or 16 (AMS84) plug-in cassettes.

Each cassette is equipped with the relevant 5B module and suitable input connector.

The suitable input connector on the front panel guarantees for the relevant connection to be available when exchanging the cassette.

The following cassettes are available:

| Product | Description | | AMS-K-BIN5 | cassette with panel and 5-pole Binder female connector (712 series) | | AMS-K-BLANK | blank panel | | AMS-K-BNC | cassette with front panel and BNC female connector | | AMS-K-CO5 | cassette with front panel and 5-pole terminal connector | | AMS-K-THK | cassette with front panel and thermocouple socket (type K) |

AMS-HANDLE, AMS-HANDLE2

For mobile use, the AMS42/84 can be equipped with a lateral, foldaway strap carrying handle (AMS-HANDLE) or with two stable metal handles at the housing frame (AMSHANDLE2).

AMS-EXT8

With the add-on option AMS-EXT8, 8 additional analog channels each are available for the AMS42/84 accessible at the back of the amplifier measurement system. The AMS42 can be extended to max. 16 channels, the AMS84 to max. 32. The analog outputs are accessible at a second D-Sub37 female with the same assignment as the D-Sub37 female of the AMS device (see chapter 2.3).



Important notes for using the AMS42/84

The device is only suitable for extra-low voltages - please observe the relevant regulations! For reasons relating to EMC, it must only be used in closed PC housings.

Only use an electrical isolated power supply unit (with CE).

Only use non-solvent detergents for cleaning. The product is designed to be maintenance-free.

For calibration purposes, the device must be returned to BMC Messsysteme GmbH.

Use shielded cables for reasons relating to CE. Connect the shield to ground at one end only. Close open inputs if possible.

When mounting the cassettes, a connection between power supply ground and chassis of the device is made via the module screw.

The device must not be used for safety-relevant tasks. With the use of the product, the customer becomes manufacturer by law and is therefore fully responsible for the proper installation and use of the product. In the case of improper use and/or unauthorized interference, our warranty ceases and any warranty claim is excluded.

Do not dispose of the product in the domestic waste or at any waste collection places. It has to be either duly disposed according to the WEEE directive or can be returned to bmcm at your own expense.


Technical data

(typical at 20°C, after 5min., +24V supply)

Electrical data

Power supply:+9..40V DC, ±5%, min 3W, max. 20W (depends on number of 5B modules used) at 3-pole DIN male

Galvanic isolation:depends on the 5B modules used

Max. permissible potentials:60V DC acc. to VDE

General data

Signal connection:different connectors (Phoenix, Binder, BNC, Thermo) on the front panels of the cassettes

CE standards:EN61000-6-1, EN61000-6-3, EN61010-1; for decl. of conformity (PDF)

ElektroG // ear registration:RoHS and WEEE compliant // WEEE Reg.-No. DE75472248

Protection:IP20

Temperature ranges:operating temp. -25..50 ° C, storage temp. -25..70 ° C

Relative humidity 0-90% (not condensing)

Dimensions (W x H x D):AMS42-USB: 23.5 x 13.2 x 25.6 cm 3 ; AMS84-USB: 48.3 x 13.2 x 25.6cm 3 (incl. mounting brackets)

Delivery:device, description

Warranty:2 years from date of purchase at bmcm, claims for damages resulting from improper use excluded

Available accessories

AMS-K-BIN5:cassette and front panel with 5-pole Binder socket (712 series)

AMS-K-BLANK:blank panel

AMS-K-BNC:cassette and front panel with BNC female

AMS-K-CO5:cassette and front panel with 5-pole terminal connector

AMS-K-THK:cassette and front panel with thermocouple socket (type K)

AMS-EXT8:extension of 8 extra channels (accessible on the back of the device)

Other accessories:desktop power supply ZU-PW70W (24V, 2.92A DC), 3-pole DIN female ZU3DIN,USB extension cable ZUKA-USB, carrying handles AMS-HANDLE, AMS-HANDLE2

image.png

  • SIGMATEK ICA111 Module
  • SIGMATEK MDD 121-1 Drive Axis Module
  • SIGMATEK M5V121 12-300-121 Krauss Maffei M5 Display Unit
  • SIGMATEK CTMS 020 CD Technology Module 12-250-011
  • SIGMATEK PCT122 Touch Panel
  • Stöger MCS4100 SIGMATEK Control Module
  • SIGMATEK Krauss Maffei M5 Keyboard Unit M5K902 12-310-902
  • SIGMATEK SD310-2 Servo Drive Module
  • SIGMATEK CM5V020 CD Wiring Circuit Module
  • SIGMATEK ENGEL Robot Drive M3 02220-8748
  • Sigmatek CFF011 Drive Module
  • Sigmatek DCP642 DIAS Central Unit
  • Sigmatek SDM081 S-DIAS Safety Module
  • Sigmatek C-IPC 01-450-024 Industrial PC
  • Sigmatek Kompakt NC4 Control Module
  • Sigmatek VI021 VARAN Interface Module
  • Sigmatek Engel RD-M6-2 Robot Drive
  • Sigmatek CNC031 Positioning Module
  • Sigmatek TO161 Digital Output Module
  • Sigmatek CCL912 CPU PSU Module
  • Sigmatek ETV0821 Operator Terminal
  • SIGMATEK ET 261 Operator Terminal
  • SIGMATEK CP731-K Control Module 20-004-731-K
  • SIGMATEK ETEK Motherboard 12-250-021-K CM5V020
  • Sigmatek DEZ 181 DIAS Input Output Module
  • Sigmatek IPC111-D Industrial PC
  • SIGMATEK AKM54L-ANC2GBB0 Servomotor with Gearhead
  • SIGMATEK CTMS020 CM5V020 CNC Controller
  • DEMAG ERGOTECH 061 381 66 Sigmatek Control Unit
  • Sigmatek DAI 883 Module
  • Sigmatek ETV1521 Control Panel Installation Terminal
  • Sigmatek 9802.289.01 Board Control TA71 Display
  • Wittmann Sigmatek EU-252 proDrive W4 Servo Drive
  • Sigmatek CDM166 C-DIAS Module
  • Sigmatek DCP082 DIAS Central Unit
  • Sigmatek CCP081 C-DIAS Processor Module
  • Sigmatek MD111-1 Drive Module
  • Sigmatek ETV0821 Operator Terminal
  • Sigmatek ISE021 Interface Module
  • Sigmatek DCC080L Slide Control Module
  • Sigmatek AI075 Analog Input Module
  • SIGMATEK TO161 20-007-161 Module
  • SIGMATEK CIC011 Module
  • SIGMATEK AE0000318502 Hand Terminal Pendant
  • Sigmatek Krauss Maffei PC323-K Control Unit
  • Sigmatek Krauss Maffei PC321-K Control Cabinet PC
  • SIGMATEK CIV521 Control Module
  • SIGMATEK C-IPC-171 Industrial PC
  • SIGMATEK MDP101-L DIAS Drive Network Module
  • Sigmatek Krauss Maffei PC323-K Control Cabinet PC
  • SIGMATEK CRCH081 C-SLIDES Temperature Module
  • Sigmatek PC301-E6 Industrial PC SSD
  • Sigmatek SDI101 S-SLIDES Safety Input Module
  • Sigmatek CIV521 VARAN Control Module
  • Kollmorgen Sigmatek AKM42G-ANCNGBB0 Servo Motor
  • Sigmatek PC 521 Process Controller
  • Sigmatek Geode LX800 12-780-012 Industrial PC
  • Sigmatek STO081 S-DIAS Safety Output Module
  • Sigmatek SCP111 S-DIAS Safety CPU Module
  • Sigmatek CDI161 Industrial I O Module
  • Sigmatek Wiring Board V2 DIAS 05-250-023
  • Sigmatek CP102 20-004-102 S-DIAS CPU Module
  • SIGMATEK SLIDES CNC 115 Module
  • SIGMATEK DCC080 05-700-080-2 Control Module
  • SIGMATEK MDD 121 Drive Axis Module
  • SIGMATEK CIO011 C-DIAS Multi I/O Module
  • SIGMATEK CIV512 Servo Drive
  • SIGMATEK CM5V020 12-250-021-K Wiring Module
  • SIGMATEK CIO011 12-013-011 Multi I/O Module
  • SIGMATEK 01-450-031 C-IPC Industrial Computer
  • SIGMATEK AKM24D-ANBNGBB0 Servo Motor
  • DEMAG NC4 LP0001289.03 Control Module
  • Sigmatek ETEK Industrial PC C-IPC with Option Module
  • Sigmatek AO081 20-010-081 Analog Output Module
  • Sigmatek CNC 031 Positioning Module
  • Sigmatek CP731-K 20-004-731-K CPU Module
  • Sigmatek MDD 3320-JR-A Drive Module
  • Sigmatek PM Servo Motor AKM52K-ANC2GBB0
  • Sigmatek MDP 101 09-403-101 Power Module
  • Sigmatek S-SLIDES AO046 Analog Output Module
  • Sigmatek ICA111 20-102-111 Interface Module
  • SIGMATEK DCP646 Module 05-004-646
  • SIGMATEK SDI101 Digital Input Module 20-891-101
  • SIGMATEK S3330-2 Directional Gyro Altitude Instrument
  • SIGMATEK MDP102-1 Controller
  • SIGMATEK SMT 01-230-321 Touch Screen
  • SIGMATEK Krauss Maffei PC301-K 01-310-301-K Industrial PC with 8GB SSD
  • SIGMATEK ETT731 01-230-731 Built-in Touch Terminal
  • SIGMATEK CIV521 Control Module
  • SIGMATEK DME 128 Module 05-005-128
  • SIGMATEK SCP111-S 20-890-111-S S-DIAS Safety CPU Module
  • Sigmatek SCP111 S-DIAS Safety CPU
  • Sigmatek CRIF081 Interface Module
  • Sigmatek CP112-1 S-DIAS CPU Module
  • Sigmatek MDD121-L DIAS Drive Axis Module
  • Sigmatek C-IPC 01-450-024 Industrial PC
  • Sigmatek SDD215-23 SLIDES Drive
  • Sigmatek DPS001 DIAS System Components
  • Sigma-Tek 4000B-30 Directional Gyro
  • Sigmatek SDD340-46 SDD Series Drive
  • Sigmatek CEZ221 Euromap67 I O Module
  • SIGMATEK VI021 Interface Module
  • SIGMATEK CP731-K Control Module
  • SIGMATEK Krauss Maffei PC321-K Industrial PC
  • SIGMATEK ET322 Operator Terminal
  • SIGMATEK CP102 Control Module 24VDC
  • SIGMATEK SRO021 Relay Output Module
  • SIGMATEK DCP640 DIAS Central Unit
  • SIGMATEK MDD 121 Drive Axis Module
  • SIGMATEK AI043 Analog Input Module
  • ENOTEC OXITEC 5000 SME-53310000 Oxygen Analyzer
  • SIGMATEK Krauss Maffei PC301-K 01-310-301-K Industrial PC
  • SIGMATEK SDD310-23 VARAN Servo Drive
  • SIGMATEK CDM 163 and CIC 011 C-DIAS Input Modules
  • SIGMATEK MDP 101-1 Power Module
  • SIGMATEK CM5V020 Wiring Circuit with CTMS020
  • SIGMATEK CCP521 C-DIAS Processor Module
  • SIGMATEK MDP 101-K Power Module
  • SIGMATEK ETEK C-IPC 733MHz VIA Eden 7000
  • SIGMATEK DCP 643 DIAS PLC CPU Module
  • SIGMATEK TAE121 12-200-121 Operator Terminal
  • Sigmatek TMS012-T Injection Moulding Technology Module
  • Sigmatek MDD 121-1 Controller
  • Sigmatek CDM167 Module
  • Sigmatek DCP082 DIAS Central Unit
  • Sigmatek ETT731 Built-In Terminal Touch
  • Sigmatek CCP521 C-DIAS Processor Module
  • Sigmatek Krauss Maffei PC301-K Control Cabinet PC