Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

UniOP CP01R-04, CP05R-04, and CP01F-02 Compact Low Cost HMI Devices

来源: | 作者:FAN | 发布时间 :2026-03-10 | 17 次浏览: | Share:

Recipe Memory: CP01R-04 and CP01F-02 reserve 16 KB of dedicated recipe storage space, supporting configuration and transmission of up to 255 parameter sets. CP05R-04 does not support formula function.

Event List: CP01R-04 and CP01F-02 support 256 historical event records, while CP05R-04 does not provide this feature.


Communication capability

6.1 Built in communication interface

PLC port: Provides multiple physical layer interfaces including RS-232, RS-422, RS-485, and 20mA current loop, with communication rates configurable from 9600 to 38400 bps (CP01 series has the highest speed of 38400 bps, CP05 series has a fixed speed of 9600 bps). This port can directly connect various brands of PLCs or smart devices.

PC/Printer Port: The CP01 series is equipped with a separate PC/printer port for project downloads or connecting to a serial printer. The CP05 series does not have this port.

Auxiliary port: All models provide an auxiliary port for connecting optional functional modules (such as fieldbus or Ethernet modules). This port supports high-speed communication, enabling HMI to access industrial networks.

6.2 Dual Drive Capability

CP01R-04 and CP01F-02 support "dual drive" communication, which means that one panel can communicate with devices of two different protocols simultaneously (such as connecting two PLCs at the same time), achieving centralized display and control of data. CP05R-04 does not have this capability.

6.3 Optional fieldbus module

Through auxiliary ports, the CP series can install TCM/SCM series modules, supporting industrial networks such as Profibus DP, DeviceNet, CANopen, Interbus, and Ethernet. This enables seamless integration of HMI into existing control systems, serving as distributed I/O or master/slave devices.

Software and Programming

All CP series panels are developed using UniOP Designer for Windows programming software. This software provides the following core functions:

Intuitive graphical interface design: Create display pages by dragging and dropping, placing elements such as text, values, bar charts, etc.

Multi language support: Multiple language versions can be created in one project, and languages can be switched at runtime through buttons or variables to meet the needs of global devices.

Keyboard Macro Editor: allows users to write macro instructions for function keys, enabling complex local operation sequences and reducing the burden of PLC programming.

Communication driver library: Built in communication driver programs for over 130 industrial equipment, covering mainstream PLCs, frequency converters, instruments, etc., ensuring fast connection.


Functional characteristics

8.1 Data Display

The CP series supports multiple data formats for display, including integers, floating-point numbers, dates, times, text strings, and bar charts. By linearly scaling the variables, the raw data can be converted into engineering units for display.

8.2 Alarm Management

Number of alarms: CP01R-04 and CP01F-02 support up to 1024 alarm definitions, while CP05R-04 supports 256.

Alarm List: It can display current active alarms in real-time and provide historical alarm event records (up to 256).

Alarm confirmation: The operator can confirm the alarm by pressing the button, and the system records the confirmation time and operator information (which needs to be coordinated with the printer output).

8.3 Formula Storage

The recipe function allows users to predefine multiple sets of parameters and download the entire set of data to the PLC or upload it from the PLC to the HMI through simple operations. The CP01 series supports 16 KB recipe memory and is suitable for scenarios that require frequent switching of production parameters.

8.4 Security mechanism

The eight level password protection mechanism can restrict access to specific pages, variables, or functions to prevent unauthorized operations. Password levels can be associated with user permissions to ensure system security.

8.5 UniNet Network

CP01R-04 and CP01F-02 support UniNet network and can serve as client/server nodes for data exchange with other UniOP panels or upper computers. CP05R-04 only supports client mode and can read data from other devices in the network.


Electrical and Environmental Specifications

Protection level: The front panel meets the IP65 standard, is dustproof and water-resistant, and suitable for industrial installation on site.

Working temperature: Standard models range from 0 to 50 ° C, with optional extended temperature versions (-20 to 70 ° C) to meet harsh environmental requirements.

Power supply: 24 VDC power supply, power consumption varies slightly depending on the model, but all are below 10W.

Backlight lifespan: The LED backlight of LCD models has a lifespan of up to 100000 hours and requires almost no maintenance.


Physical installation and dimensions

The CP series adopts a panel installation method, with a compact front panel size, suitable for control cabinets with limited space. The detailed installation hole size can refer to the product manual, but all models are designed with uniform standard holes for easy replacement and upgrading.


Attachments and extensions

  • UNIOP eTOP20C-0050 Color HMI Touch Panel Data
  • UNIOP MD00R-02-0045 Text-Based Display Module
  • UNIOP eTOP05-0045 Operator Interface
  • UNIOP ETOP11-0050 HMI Color Operator Interface Data
  • UNIOP eTOP306 Industrial Touch Panel
  • UNIOP CP04F-04-0045 HMI Panel
  • UNIOP ETOP308U301 HMI Touch Panel
  • UNIOP MD00R-02-0045 Operator Panel
  • UNIOP ePALM10-0061 Handheld Teach Pendant
  • UNIOP CP05R-04-0045 HMI Operator Panel
  • UNIOP MD02R-04-0045 Text-Based Operator Module
  • UNIOP CP02R-04-0021 Compact Operator Panel
  • UNIOP CP04F-04-1945 Industrial HMI Control Panel
  • UNIOP ECT-16-0045 Communication Module Data Sheet
  • UNIOP EPALM10-0061 Handheld HMI Technical Specifications
  • UNIOP ERT-16-0042 Remote Terminal Unit
  • UNIOP ePAD04-0046 HMI Controller
  • UNIOP BKDR-16 Operator Interface Display
  • UNIOP MKDR-04-004 Control Unit Panel
  • UNIOP ETOP515U3P1 HMI Touch Panel
  • AMAT 0190-15779 Advanced Controller Module
  • Applied Materials AMAT 0010-23715 Mechanical Assembly
  • AMAT 0190-14502 Communication Interface Module
  • AMAT 0195-14157.RMA Power Distribution Module
  • Applied Materials AMAT 0021-84842 Precision Component
  • AMAT 0190-37519 DC Power Supply
  • AMAT 0100-71267 RF Generator Module
  • ALSTOM V4561484-0100 Analog Input Module
  • ALSTOM PIB903 Process Interface Board
  • ALSTOM 029.202.781 Protection Relay
  • ALSTOM 029.148.924 Enhanced Motor Relay
  • ALSTOM 029.148.906 Motor Protection Relay
  • ALSTOM 029.147.908 Transformer Protection Relay
  • ALSTOM 029.144.456 Advanced Feeder Relay
  • ALSTOM 029.144.440 Feeder Protection Relay
  • ALSTOM P40 AGILE MiCOM P141 Feeder Protection Relay
  • ALSTOM I/OBE2 12004-104-00 V1.0.0 I/O Interface Module
  • ALSTOM V4561983-0100 Industrial Control Module
  • ALSTOM VOOB8-B 12004-106-04 V1.0.0 Output Interface Board
  • ALSTOM VPS 12004-102-03 V1.0.0 Voltage Processing Board
  • ALSTOM POS1846 TRVC062333000 CP00000310 Position Control Module
  • ALSTOM DSI1817 TRVC062335000 CP00003934 Digital Input Module
  • ALSTOM CMP1838 TRVCO62345000 CP00005202 Processor Module
  • ALSTOM STO1726KO1 Integrated Control Module
  • ALSTOM I/OBUS2 12004-103-01 VER:V1.2.0 Communication Interface
  • ALSTOM 730475-D ELEMENTS-F2 Cabinet Heater
  • ALSTOM N897163510Q / N897163050Q MODEM and N897163100U Interface Unit
  • ALSTOM N897066 AOVD Analog Output Module
  • ALSTOM CMU 42015-115-00 Communication Unit
  • ALSTOM NRD108028 Digital Protection Relay
  • ALSTOM 42011-106-00 ITC_VIOM_VIOC VER.A01 Interface Card
  • ALSTOM N897093511D DIAGNOSTICA N897093400H Interface Unit
  • ALSTOM N895609510K N895609010R E32OUT Digital Output Module
  • ALSTOM MLU VER.A01 Main Logic Unit
  • ALSTOM NRD109475 8RDA44670G01 SA44670.E Control Module
  • ALSTOM VIIB16-C 12011-105-00 Interface Board Module
  • ALSTOM VCS232 590.043158 Control System Module
  • ALSTOM V0701596-001102 Industrial Control Module
  • ALSTOM N895313512X N95313012D SUP-AL Control Module
  • ALSTOM 12004-102-01 VPS Board Ver.C Power Control Board
  • ALSTOM NRD108034 8RDB44674G01 SA44674.C Control Card
  • ALSTOM N897092520B N897092057Y TRENO N897092500E
  • ALSTOM NRD108033 8RDC44667G01 SA44667.C Control Circuit Board
  • ALSTOM TRVC062105000 TRVC070938000 Series Specification
  • ALSTOM SDK-C0147 12004-101-00 SBS04M17C Control Module Technicals
  • ALSTOM N895313512X Digital Output Module
  • ALSTOM P70035W82V Feeder Protection Relay
  • ALSTOM N897164624A Digital Input Module
  • ALSTOM N897164611M Power Supply Module
  • ALSTOM N897164610L Communication Interface Module
  • ALSTOM N70032702L Protection Relay Module for Power Systems
  • ALSTOM MVAJ21L1GB0771B Voltage Protection Relay
  • ALSTOM MFAC34N1AA0001A Overcurrent Protection Relay
  • ALSTOM MCTI40N1AB0751G Current Differential Protection Relay
  • ALSTOM MCGG22L1CB0753E Overcurrent Protection Relay
  • ALSTOM MVAW 11B1AB0513A Trip Circuit Supervision Relay
  • ALSTOM MVTU 11K1CD0751G Voltage Transformer Supervision
  • ALSTOM MVAJ27L1FB0784D High Speed Tripping Relay Guide
  • ALSTOM MAVS01L1AB0501D Voltage Selection Relay Documentation
  • ALSTOM MVAW11B1AB9007A Trip Circuit Supervision Relay
  • ALSTOM MFAC14K1AA0001A Feeder Protection Relay
  • ALSTOM MCGG62N1CB0753F Generator Protection Relay
  • ALSTOM MAVS01L1AB0751D Protection Relay
  • ALSTOM PIB1201A 3BEC0067 Interface Module
  • ALSTOM V4555724-0100 Voltage Protection Relay
  • BENTLY 1900/65A-01-01-03-00-01 Monitor
  • BENTLY 3500/42-01-00 Proximitor Monitor
  • BENTLY 3500/54-03-00 Temperature Monitor
  • BENTLY 163179-02 Accelerometer
  • BENTLY 3500/94 145988 Display
  • Bently Nevada 1X35668 Replacement Internal Component Analysis
  • Bently Nevada 3500/22M 138607/01 Transient Data Interface
  • Bently Nevada 3500/40M 135489-04 Proximitor Monitor Module
  • Bently Nevada 3500/40M 125680-01 Proximitor Monitor
  • Bently Nevada 3500/15 127610-01 Power Supply Module
  • Bently Nevada 1900/65A-00-01-01-01-01 Machinery Monitor
  • Bently Nevada 3500/65 145988-02 Temperature Monitor
  • Bently Nevada 330876-03-50-00-00 Proximity Probe
  • BENTLY 3500/93 135785-02C System Display Module
  • BENTLY 3701/55 323174-01 ADAPT Input/Output Module
  • BENTLY 3500/42M 140734-99 Modification Module
  • BENTLY 3701/55 289761-01 ADAPT Emergency Shutdown Device
  • BENTLY 3500/42M 140734-02 Proximitor Seismic Monitor
  • BENTLY 3500/15 114M5330-01 Power Supply Module
  • BENTLY 3500/92 136180-01 Communication Gateway
  • BENTLY 3500/93 135799-01 LCD Display Module
  • BENTLY 3500/22 Transient Data Interface Module
  • BENTLY 9200-01-01-10-00 General Purpose Monitor
  • BENTLY 3500/65 145988-02 Temperature Monitor
  • BENTLY 1900/65A 172323-01 General Purpose Monitor
  • BENTLY 3500/22M 138607-01 Transient Data Interface
  • BENTLY 149986-01E 3300 XL 8mm Proximity Probe
  • BENTLY 1900/65A-01-01-03-00-01 General Purpose Monitor
  • BENTLY 136719-01 3500/92 Communication Gateway I/O
  • BENTLY 3500/22-01-01-00 Transient Data Interface Module
  • BENTLY 3500/22M 288055-01 Transient Data Interface
  • BENTLY 131151-01 3500/50 Tachometer I/O Module
  • BENTLY 1900/65-00-01-03-01-01 General Purpose Monitor
  • Bently Nevada 3500/54 133396-01 Overspeed Detection Monitor
  • Bently Nevada 3500/45 176449-04 Position Monitor
  • Bently Nevada 3500/42 140471-01 Proximitor Monitor
  • Bently Nevada 3500/94 147663-01 VGA Display Module
  • Bently Nevada 3500/42M 140482-01 Proximitor Monitor
  • BENTLY 3500/53 133396-01 Relay Module (Alternate Version)
  • BENTLY 3500/20 125744-01 Rack Interface Module
  • BENTLY 3500/53 133388-01 Relay Module
  • BENTLY 3500/15 114M5335-01 Power Supply Module
  • BENTLY 3500/40M 140734-01 Proximitor Monitor Module