Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

How to order KOLLMORGEN Saia PCD series I/O modules?

F: | Au:FAN | DA:2025-08-25 | 775 Br: | 🔊 点击朗读正文 ❚❚ | Share:


KOLLMORGEN Saia PCD Series I/O Modules

Basic Information

Core scope

Covering five major categories of modules: digital input/output modules, analog input/output modules, digital hybrid I/O modules, counting and motion control modules, and special function modules (such as weighing and thermocouple modules), while distinguishing the differences between PCD2 and PCD3 series modules (such as the addition of cage spring terminals and higher anti-interference levels in PCD3), supporting industrial standard signal types such as 24V DC/115-230V AC input and 0-10V/0-20mA analog signals. Some modules have electrical isolation (up to 500V isolation voltage) and short-circuit protection functions.

Version and compatibility

Document historical version updates focus on module function supplementation (such as adding PCDx.B160/W380/G200 modules in ENG07), parameter correction (such as adjusting product status section in ENG09), and the latest version of ENG10 optimizes PCD3.A810/W800 power consumption parameters; In terms of hardware compatibility, the PCD2 module needs to be compatible with CPU hardware version H or above, while the PCD3 module supports RIO remote IO systems (some modules such as H210/H31x are currently not compatible).

Core module classification and technical parameters

(1) Core parameters of PCD2 series modules

1. Digital input module

Module model, number of input channels, signal range, response time, electrical isolation, wiring method

PCD2.E110 8 24V DC 8ms without 10 pole screw terminal

PCD2.E160 16 24V DC 8ms without 34 pole ribbon cable connector

PCD2.E500 6 115-230V AC 10ms (pull in)/20ms (release) with (2.5kV optocoupler isolation) 10 pole screw terminal

PCD2.E610 8 24V DC 10ms with (1kV AC isolated) 10 pole screw terminal

2. Digital output module

Module model, output channels, rated current signal range, protection function

PCD2A300 6 2A/channel 10-32V DC without short circuit protection, requires external 12.5A fast melting

PCD2.A400 8 0.5A/channel 5-32V DC without short circuit protection, load resistance ≥ 48 Ω

PCD2.A200 4 2A/channel (relay) 250V AC/50V DC varistor+RC component contact protection

PCD2.A410 8 0.5A/channel 5-32V DC electrical isolation (1kV AC), without short circuit protection

3. Analog input module

Module model, channel number, resolution, signal type, accuracy (25 ℃)

PCD2.W100 4 12 bit 0-10V/-10~+10V ± 0.1% ± 1LSB

PCD2.W220 8 10 bit Pt/Ni1000 temperature sensor ± 3LSB

PCD2.W305 7 12 bit 0-10V ± 0.15%

PCD2.W745 4 16 bit J/K type thermocouple ± 0.4 ℃ (0-100 ℃)

4. Counting and motion control module

Module model, function, highest frequency, number of axes, encoder support

PCD2.H100 pulse counting 20kHz incremental encoder (phase A/B)

PCD2.H150 SSI interface 500kHz 1 absolute encoder (SSI protocol)

PCD2.H210 stepper motor control 19.45kHz 1 24V DC encoder

PCD2.H310 servo motor control 100kHz 1 24V DC incremental encoder

(2) Core Upgrade of PCD3 Series Modules

The PCD3 series optimizes terminal design, anti-interference performance, and functional expansion based on PCD2, with the following core differences:

Module type: PCD2 series features: PCD3 series upgrade points

The screw terminal of the digital input module (with a maximum wire diameter of 1.5mm ²) has added cage spring terminals (such as 24 pole terminals for E165, supporting a wire diameter of 1.0mm ²), and the anti-interference level has been raised to IEC 61000-4-4 (± 2kV capacitive coupling)

The 8-bit resolution of the analog output module is mainly increased from the W6x0 series to 12 bit resolution, with an output delay of ≤ 10 μ s and support for -10~+10V bipolar signals

The motion control module only supports local IO H32x series, supports DSP processors, realizes S-curve trajectory planning, and supports 250kHz encoder input

Wiring compatibility only supports fixed terminals, supports PCD3.K010/K106 connection cables, and modules can be directly cascaded (maximum distance of 2.5m)

(3) Electrical isolation and safety characteristics

Isolation type and level

Digital isolation module (such as PCD2. E610/PCD3. E610): using optocoupler isolation, isolation voltage 1000V AC (1 minute), no isolation between channels, suitable for strong interference environments (such as near frequency converters);

Analog isolation module (such as PCD2. W3x5/PCD3. W3x5): adopts DC/DC isolation, isolation voltage of 500V, supports 7-channel analog signal acquisition, suitable for signal isolation in process control (such as chemical equipment).

Safety Specifications

High voltage modules (such as PCD2, E500, PCD3, E500115-230V AC input) need to be separately equipped with fuses (1A/250V), and are prohibited from being connected together with low voltage signals (≤ 50V);

The contact protection of relay output modules (such as A200/A210) needs to be matched with the load type: inductive loads require external current diodes, and capacitive loads require series current limiting resistors to avoid contact arc damage.

Installation and wiring specifications

(1) Mechanical installation requirements

Installation environment

Working temperature: 0-55 ℃ (if it exceeds 40 ℃, the output current should be reduced by 2% for every 1 ℃ increase);

Protection level: IP20 (IEC 60529), to be installed inside the control cabinet to avoid dust and condensation water;

Installation spacing: Reserve ≥ 25mm heat dissipation space on both sides of the module for vertical installation (allowing ± 15 ° tilt), and additional fixation is required for heavy-duty modules (such as PCD2. H32x).

Terminal installation

Screw terminal: torque 0.7-0.8Nm (compatible with M3 screws), wire diameter 0.5-2.5mm ²;

Cage type spring terminal (PCD3 specific): No tools required, directly insert the wire (maximum 1.0mm ²), press the release button when pulling out, and increase wiring efficiency by 30%.

(2) Key specifications for electrical wiring

Power supply and grounding

Digital module: 24V DC power supply needs to be supplied separately (ripple ≤ 10%), PE wire cross-section ≥ 1.5mm ², single point grounding is used (grounding resistance ≤ 1 Ω);

Simulation module: The signal ground and power ground are wired separately, and the analog signal cable adopts twisted pair shielded wire (single end grounding of the shielding layer) to avoid parallel connection with the power cable (spacing ≥ 200mm).

Typical wiring example

Digital input (source wiring): PCD2.E110 module E0-E7 is connected to the sensor signal,+24V is connected to the positive pole of the external power supply, and the negative pole of the sensor is connected to the module GND. The LED lights up to indicate that the input is valid;

Analog output (current type): PCD3.W410 module A0 connected to actuator (such as valve positioner), external 24V DC power supply positive pole connected to actuator, negative pole connected to module A0 terminal, select 4-20mA signal range through jumper;

Isolation module: The PCD2.E610 module needs to be separately connected to a 24V isolation power supply, and the signal end should be completely isolated from the PLC system ground to avoid common ground interference.


Function configuration and programming support

(1) Hardware configuration

Address setting

Digital module: Set the CANopen station address (1-99) and baud rate (10-1000kbit/s) through the DIP switch on the front-end of the module. After setting, restart the 24V power supply to take effect;

Expansion card configuration: Multifunctional modules such as PCD2.G410 need to be plugged into a communication expansion card (such as a PROFIBUS card) through Slot 1/2, and the module will automatically recognize it after power on. If it is not recognized, the locking status of the card buckle needs to be checked.

Signal filtering

Digital input: Select the filtering time through the internal jumper of the module (such as PCD2.E111 supporting 0.2ms/8ms switching), and select a short filtering time for high-frequency signals (such as encoders);

Analog input: PCD3.W380 supports software configuration of digital filtering (50/60Hz notch filtering) to suppress power grid interference, with a filtering time constant of 2.4ms.

(2) Software Configuration (PG5 Environment)

tool support

Saia PG5 software (version ≥ 2.3) is required to configure module parameters through the "Device Configurator":

Motor configuration: Select the motor model (such as AKM series servo motor), automatically load rated current, inductance and other parameters, and execute "Motor Probe" to optimize the current loop gain;

Safety configuration: The STO function needs to be associated with a safety controller and set a periodic testing interval (≤ 8 hours, meeting SIL CL3 requirements);

Linearization of analog signals: The PCD2-W745 thermocouple module requires the selection of thermocouple type (J/K type), and the software automatically compensates for the cold junction temperature (compensation accuracy ± 0.2 ℃).

Programming Example

Counting function: PCD2.H100 reads the counting value through the IL command "RD-DIGIAL-IO-0TO15", and sets "WR-DIGIAL-OUTPUT0TO15" to trigger the counter reset;

Servo control: PCD2.H310 sets the target position through the FB function block "MC_SoveAbsolute", and the parameter "Position" is filled in with the number of pulses (to match the electronic gear ratio).


Troubleshooting and Maintenance

(1) Common faults and solutions

Troubleshooting steps for possible causes of fault phenomena

No response to digital input (LED not lit) 1. Power supply not working; 2. Loose wiring; 3. Input signal exceeds the range. 1. Measure the 24V voltage at the X4A terminal of the measurement module; 2. Re tighten the terminal screws (torque 0.8Nm); 3. Check the sensor output (e.g. NPN sensor needs to output a low level)

Simulated output deviation exceeds tolerance 1. Calibration parameters are lost; 2. Load impedance mismatch; 3. Signal distortion caused by interference. 1. Perform "Analog Calibration" through PG5 to recalibrate; 2. Confirm load resistance: voltage output ≥ 3k Ω, current output ≤ 500 Ω; 3. Add shielding layer grounding (single ended grounding)

Relay output contact adhesion: 1. Load current exceeds the set value; 2. Contactless protective components; 3. Frequent switching: 1. Measure the load current (such as A200 maximum 2A/channel); 2. Inductive load connected in parallel with 1N4007 freewheeling diode; 3. Reduce switching frequency (recommended ≤ 10 times/minute)

The frequency of the counting module is abnormal. 1. The encoder cable is too long; 2. Signal interference; 3. Improper setting of filtering time: 1. Cable length ≤ 10m (signal repeater is required for over distance); 2. Use twisted pair shielded wires (with the shielding layer grounded); 3. Set the filtering time to 1/5 of the signal period (e.g. 10 μ s for a 20kHz signal)

(2) Regular maintenance project

Standard requirements for maintenance project cycle operation content

Terminal inspection every quarter: 1. Tighten screw terminals (torque 0.7-0.8Nm); 2. Clean the terminal dust and ensure that the terminal is free from oxidation and looseness, with a contact resistance of ≤ 10m Ω

Module temperature monitoring: 1. Measure the temperature of the heat sink every month; 2. Check the fan speed (e.g. PCD2.H32x fan ≥ 2500rpm), the temperature of the heat sink is ≤ 75 ℃, and the fan has no abnormal noise

Calibration verification every six months: 1. Analog input: Input standard signal (such as 5V/10mA), read module values; 2. Analog output: Set 50% output, measure actual value deviation ≤ ± 0.5% (if exceeded, recalibration is required)

Monthly safety function testing: 1. Trigger the STO function and check if the motor torque is cut off; 2. After testing the safety relay contacts and activating STO, the motor has no torque, and the contact response is ≤ 10ms

Product lifecycle and spare parts management

Product status classification

The manual specifies the status of modules "Active", "Outphased", and "Repair phase":

The maintenance period for discontinued modules (such as PCD2.G400/G410) is until December 31, 2018, and there will be no spare parts supply thereafter;

Alternative solutions: Replace PCD2.W100 with PCD2.W380, and PCD2.H222 with PCD3.H222.

Recommended spare parts list

It is recommended to reserve 1-2 sets of key spare parts, with the following matching models:

Module type/common model/spare part model

Digital input module/PCD3.E110/PCD3.E111 (compatible and responsive)

Analog output module/PCD2.W410/PCD3.W410 (terminal upgrade)

Relay module/PCD2.A200/PCD3.A200 (same function, higher anti-interference)

Counting module/PCD2.H100/PCD3.H110 (maximum frequency increased to 100kHz)

  • VALMET PMB 2R 16 Slot Backplane PCB Card
  • NELES VALMET A413135 AOU 4 Output Module
  • Metso Valmet A413345 FPU Power Unit
  • VALMET A413171 PIC Module
  • VALMET A413620 Repeater Module
  • Valmet M851521 Memory Card
  • Valmet DIFF-EL 140 M1 Transmitter
  • Valmet A413064 DMU Module
  • Valmet IOP371 I/O Bus Extender Module
  • Valmet Cooking Liquor Measurement 3400 Model 3417H
  • Metso Valmet A413043 CPU Module – Industrial Processor
  • Valmet BIU4 M851221 Binary Input Module
  • Valmet PMB 1S CPU SCU Rack Module
  • Valmet A413248 Controller Module
  • Valmet PDP601 Distributed Processing Unit
  • VALMET M851004 M2 CPU Printed Circuit Board Module
  • Metso Valmet A413045 Ver.05 CPU Module
  • Valmet A413181 Ver.05 PLU1 Board
  • Lyngso Valmet ATB16 Controller Board
  • VALMET AIU 16 Analog Input Unit 545100-3A/3B
  • VALMET PUD 10 B Power Supply PCB Rack Module
  • Valmet MS-50V/120V Bearing Unit
  • Valmet PDP603 Distributed Processing Unit – DPU Module
  • Valmet A413110 TIU Board – Terminal Interface Unit
  • Valmet S420154 I/O Backplane PCB – Printed Circuit Board
  • Valmet A413173 Industrial Control Module
  • Valmet A413044 CPU Module
  • Valmet A4IU1 Analog I/O Module
  • Valmet A413325 IPU Power Unit – PLC Module
  • Valmet M851002 CPU Module – Central Processing Unit
  • Valmet PUD10B Power Supply Board
  • Valmet K00990 Master CPU Electronic Assy
  • Valmet Metso IOP345 Input Module
  • Metso Automation T545215 Board
  • Valmet Metso IOP304 Input Module
  • Valmet 542844-6A SCU Module
  • Metso A413043 Ver.11 Valmet CPU Module
  • Valmet Automation BIU 8A Input Module
  • Metso A413044 Ver05 Valmet CPU Module
  • VALMET 542821-5A Control System Rack Module
  • Metso A413005 Ver.04 Valmet CPU Module
  • Valmet M851207 AIU16 Card
  • Valmet BIU8 Binary Input Unit
  • VALMET 547070-2B CPU Printed Circuit Board Module
  • Valmet Automation A413325 Power Module
  • VALMET AUTOMATION A413135 AOU4 Module
  • VALMET ACU A413165 Model 9 Analog Controller
  • VALMET AUTOMATION A413511-02 Slot Rack with I/O Backplane
  • Valmet A413148 BIE 4 Rev 08 Board
  • Valmet ATB16-4 Controller Board
  • Neles Automation BOR82 A413292 Processor Module
  • Valmet A413015 NCU Module – Network Control Unit
  • Valmet AIU 16 Analog Input Unit – M8512071
  • Metso Valmet A413091 GDU Board
  • Valmet M851565 Damatic Main Keyboard
  • Metso A413082 CPU Module
  • Valmet A403037 GDC – Graphics Display Controller
  • Valmet A413076 FBC Board
  • Valmet A413015 NCU Module – Network Control Unit
  • Valmet A413082 CPU Module
  • VALMET AUTOMATION A413620 Fieldbus Repeater
  • Valmet Metso IOP341R Positioner Module
  • Metso A413082 Ver.04 CPU Module
  • Valmet Metso MCA FT250/10 10 Inch Sensor
  • Valmet N0542 ABMB Printed Circuit Board
  • Valmet A413000 Ver.07 CPU Module
  • Valmet A413061 Ver.05 DMU Module
  • Valmet M851241 M1 BCU Binary Input Module
  • Valmet Automation NCU A413015 Circuit Board
  • Valmet A413046 Ver.06 CPU Module
  • Valmet A651B001 Panel Mount Keyboard
  • Valmet IQ Scanner A418080R Basis Weight Detector Head
  • Metso Valmet A413370 ESU Ethernet SCSI Unit
  • Valmet A413340 FPU Power Supply Unit
  • Valmet SKF GE 400/600 Spherical Plain Bearing
  • Valmet SCU PCB Card 542844-7B – System Control Unit
  • Valmet A413075 FBU Fieldbus Controller Module
  • Valmet A413171 PIC Card Binary Output
  • Valmet A413002 Ver.05 CPU
  • Valmet ABMB PCB Card – Industrial Control Board
  • Valmet PMB 2R 542821-4A PCB Card
  • Metso Valmet A413001 CPU Module
  • Metso Valmet A413050 RSU 6 Serial Controller Unit
  • Valmet ABMB MT241 Input Mother Board
  • Valmet DAMATIC M851565 Keyboard
  • Valmet A413075 Ver05 FBC Board
  • VALMET K14891 FLEXI-U Operating Terminal
  • VALMET AUTOMATION MKB2 DAMATIC Keyboard
  • Valmet Metso Consistency Transmitter Smart Pulp M1 RL Blade
  • VALMET AUTOMATION A413230 ECU Module
  • Beckhoff EP9224-0037 - 4-Channel Power Distribution Box EtherCAT
  • Beckhoff CX2900-0026 - Solid State Flash Memory Card 20GB CFast
  • Beckhoff BK7500 - SERCOS Interface Fieldbus Bus Coupler Terminal
  • Beckhoff Ep2328-0002 - 4-Channel Input 4-Channel Output EtherCAT Box IP67
  • Beckhoff CX1020-0111 - Controller Kit Combo Interface Modules
  • B&R X20AI2237 - X20 System Analog Input Interface Module
  • Beckhoff CP2221-0010 - Multi-Touch Built-In Panel PC Touchscreen
  • Beckhoff CX1500-M310 - Fieldbus Master Interface Module 24V
  • Beckhoff CX2100-0904 - Power Charging Module Smart UPS Extension
  • Beckhoff CP3918-0000 - Multi-Touch Control Panel 18.5-Inch Monitor
  • Beckhoff CP2915-0000 - 15-Inch Multi-Touch Built-In Control Panel
  • Beckhoff CP7037-1027 - HMI Industrial Control Panel Built-In PC
  • Beckhoff EL3152 - 2-Channel Analog Input Terminal 4-20mA EtherCAT
  • Beckhoff CP6607-0000-0020 - 5.7-Inch Built-In Panel PC HMI Touch
  • Beckhoff EJ1809-0000 - 16-Channel Digital Input Pluggable Signal Level Terminal
  • Beckhoff AM8563-0N10-0000 - Synchronous Servo Motor
  • Beckhoff AX2006-S60600-520 - Compact Servo Drive Inverter
  • Beckhoff AM8053-0K20-0000 - Servo Motor with Planetary Gearbox AG3210
  • Beckhoff AM8042-0FH1-0000 - Synchronous Servo Motor
  • Rexroth R911338600 - IndraControl V HMI Terminal Beckhoff PCI Card FC9002
  • Beckhoff AX5125-0000 - 3 Phase Industrial Servo Drive 1000Hz
  • Beckhoff EP2328-0002 - 4-Channel Digital Input 4-Channel Output EtherCAT Box
  • B&R 7CP476-02 - System 2005 RTD CPU Module 3IF681.86 Interface
  • Beckhoff AX8620-0000-0000 - Power Supply Module Axis Drive System
  • Beckhoff CX1010-0111 - PLC Module CPU Controller 24V
  • Beckhoff AM8043-0H10-0000 - Synchronous Servo Motor
  • Beckhoff C6240-1009 - Control Cabinet Industrial PC Mainframe
  • Beckhoff BX8000-0000 - Bus Terminal Controller HW 4.4 Standalone
  • Beckhoff CP7721-1089-0020 - 12.1-Inch Touch Screen HMI Panel PC
  • Beckhoff CP7132-0001 - Industrial Built-In Panel PC Screen
  • Beckhoff CP2912-0010 - Multi-Touch Built-In Control Panel Display
  • Beckhoff CP2915-0000 - 15-Inch Multi-Touch Built-In Control Panel
  • Beckhoff AM8532-1EN0-0000 - Synchronous Servo Motor
  • Beckhoff AX5203-0000 - 2-Channel Digital Compact Servo Drive
  • Beckhoff CX2020-0141 - Embedded PC Core CPU Module
  • Beckhoff CP6832-0002-0010 - Built-In Industrial Control Panel Display
  • Beckhoff CX5020-0112 - Embedded PC CPU Control Module
  • Beckhoff CX5140-0175 - 4GB Embedded PC CPU Unit 24V