The Eaton 1220-0012-0002 is a high‑accuracy solid‑core current transformer designed for indoor use at voltages up to 600 V. It steps down primary currents up to 200 A to a standard 5 A secondary, enabling safe connection to metering instruments, protection relays, and energy management systems. The transformer’s robust construction and precision winding ensure reliable performance over a long service life.
Primary current: 200 A (fixed ratio)
Secondary current: 5 A
Accuracy class: 0.5 (per IEC 61869‑2 / IEEE C57.13)
Solid‑core design with molded thermoplastic housing
Built‑in mounting feet for panel or DIN rail
Terminal covers with captive screws for safety
Rated frequency: 50/60 Hz
Thermal short‑time current (Ith): 60 x In for 1 s
Rated continuous thermal current (Icth): 1.2 x In
Insulation level: 0.72/3 kV
Rated burden: 5 VA (at cos φ = 0.8)
Safety factor (FS): ≤ 5
Operating temperature: -25 °C to +40 °C
Standards: IEC 61869‑1, IEC 61869‑2, UL recognized
The core is made of high‑grade grain‑oriented silicon steel, ensuring low phase displacement and high accuracy over a wide current range. Windings are insulated with class E materials and encapsulated in a flame‑retardant UL 94 V‑0 thermoplastic case. Secondary terminals are clearly marked and recessed to prevent accidental contact. The compact footprint allows dense packing in multi‑circuit panels.

Digital power meters and submeters
Protection relays (overcurrent, earth fault)
Energy management systems in commercial buildings
Load monitoring in industrial switchboards
Retrofit of analog ammeters
The solid‑core design requires the primary conductor to be passed through the window before connection. Mounting can be done via the integrated brackets on a 35 mm DIN rail or directly onto a panel using screws. The CT is suitable for copper or aluminum busbars up to 25 mm width. Secondary wiring must be shorted or connected to a burden before powering up to avoid dangerous open‑circuit voltages.
With an accuracy class of 0.5, the 1220-0012-0002 guarantees a ratio error within ±0.5% and phase displacement within ±30 minutes at rated current. This makes it suitable for revenue‑grade metering and precise protection coordination. The transformer maintains linearity up to 120% of rated current, ensuring accurate measurement under normal and overload conditions.
The Eaton 1220-0012-0002 combines affordability with reliable performance, making it a popular choice for electrical contractors, panel builders, and facility managers who need trustworthy current sensing for monitoring and protection.