Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • Fanuc A16B-1212-0100-01 Power Supply Unit
    ❤ Add to collection
  • Fanuc A16B-1212-0100-01 Power Supply Unit

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥17435.00
      ¥18845.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:12.060KG
    • Quantity:
    • (Inventory: 99999)
Description
<span style="font-size: 18px; font-family: arial;">Fanuc A16B-1212-0100-01 Power Supply Unit</span>

Fanuc A16B-1212-0100-01 Power Supply Unit

The Fanuc A16B-1212-0100-01 is a power supply unit (PSU) used in Fanuc CNC control systems, specifically for the Series 15, 16, and 18 controllers. This module is installed in the CNC rack and supplies regulated DC voltages to the main CPU, memory, I/O, and axis control boards. The PSU converts 200-240V AC input to +5V, +12V, -12V, and 24V DC outputs, ensuring stable operation of the CNC system. It is a critical component for maintaining legacy Fanuc-controlled machine tools. The unit is designed for continuous operation and includes overvoltage, overcurrent, and short-circuit protection.

Technical Specifications

Input voltage: 200-240V AC, 50/60 Hz (single phase). Outputs: +5V DC (typical 10A), +12V DC (2A), -12V DC (1A), +24V DC (4A). Output power: approx. 150W. Protection: Overvoltage (crowbar), overcurrent (hiccup), and short-circuit on all outputs. Cooling: Forced air via internal fan. Dimensions: 200 mm × 100 mm × 150 mm (approx.). Weight: 2 kg. Operating temperature: 0°C to 45°C. Storage: -20°C to 60°C. Front panel LEDs: POWER (green), ALARM (red). Connection: via edge connector to rack backplane. The unit is hot-swappable? Not typically; power off before replacement.

Key Features

  • Power supply for Fanuc CNC racks (Series 15/16/18)

  • Input: 200-240V AC, 50/60Hz

  • Multiple DC outputs: +5V, ±12V, +24V

  • Overvoltage and overcurrent protection

  • Internal cooling fan with tachometer monitoring

  • LED indicators for power and fault status

  • Rugged design for industrial environments

  • Direct replacement for original Fanuc part

Operation and Output Specifications

The PSU supplies the main CNC backplane. The +5V rail powers TTL logic and processors. The +12V and -12V are used for RS-232 drivers and analog circuits. The +24V is used for I/O modules, relays, and field power. The total load must not exceed the rated current per rail; overloading may trigger the overcurrent protection. The internal fan runs continuously; a fan failure will cause a thermal alarm and eventual shutdown. The PSU monitors output voltages; if any output deviates beyond ±5%, the ALARM LED lights and the CPU may receive a system fault.

Applications

This power supply is used in Fanuc-controlled machine tools such as machining centers, lathes, and grinders. It is essential for maintaining older Fanuc CNC equipment where original power supplies have failed. Suitable for replacement in Fanuc Series 15, 16, 18, and some 21 systems.

Installation and Replacement

Turn off the CNC main power and disconnect the machine from the mains. Open the CNC rack cabinet. Locate the existing power supply unit (usually the leftmost or rightmost module). Remove the mounting screws and slide the unit out of the rack. Insert the replacement A16B-1212-0100-01, ensuring the edge connector aligns with the backplane slot. Secure with screws. Reconnect any external power cables (if present). Close the cabinet and restore power. Check that the POWER LED lights and the ALARM LED is off.


Maintenance and Troubleshooting

If the POWER LED is off, check the AC input fuse (internal or external). If the ALARM LED is on, measure output voltages; if missing, the unit may have failed. The internal fan should spin; if not, replace the fan or the entire PSU. Dust accumulation inside the unit can cause overheating; periodically blow out dust with compressed air. The power supply is not user-serviceable beyond fuse replacement; replace the entire unit for other failures.

Environmental and Compliance

The A16B-1212-0100-01 is a genuine Fanuc part, compliant with original safety standards. Operating temperature: 0-45°C. Humidity: 30-95% non-condensing. The unit is RoHS compliant (depending on manufacturing date).

Conclusion

The Fanuc A16B-1212-0100-01 power supply unit is a direct replacement for failed PSUs in Fanuc Series 15/16/18 CNC controls. Its robust design and comprehensive protection ensure reliable power distribution to the CNC rack components.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ADLINK NuPRO-E72 Industrial Control Motherboard
  • ADLINK MXE-5400 Industrial Control Computer
  • ADLINK M-322 Industrial Motherboard Configuration and Deployment Guide
  • ADLINK IMB-M43H Industrial Motherboard Configuration and 6th/7th Generation Core Deployment Guide
  • ADLINK IMB-M42H Industrial Motherboard Deployment and BIOS Optimization Guide
  • ADLINK i915GV-INA motherboard configuration and ISA compatibility tuning guide
  • ADLINK ETX-NR667 Core2 Duo Module Selection and Deployment
  • ADLINK ETX-BT Module Configuration and PATA to SATA Upgrade Guide
  • ADLINK CM1-BT1 Extreme Environment Deployment and Configuration
  • ADLINK cPCI-8217 VGA/LCD Module Configuration and Troubleshooting
  • ADLINK AmITX-SL-G Mini ITX Motherboard Deployment and SEMA Guide
  • ADLINK AmITX-AL-I Embedded Motherboard Deployment and SEMA Management Guide
  • ADLINK NuPRO-E315 PICMG 1.3 Industrial Motherboard Deployment Guide
  • ADLINK NuPRO-842 Pentium 4 Industrial Motherboard Deployment and Debugging Guide
  • ADLINK NuPRO-900A Dual Xeon ePCI-X Motherboard Deployment Guide
  • ADLINK cPCI-6910 Dual Core Xeon Single Board Computer Deployment Guide
  • ADLINK cPCI-6860A Dual Xeon Single Board Computer Deployment Guide
  • ADLINK CPCI-8168 Eight Axis Motion Control Card Deployment and HSL Integration Guide
  • ADLINK NuPRO-E340 Industrial Motherboard Debugging and BIOS Optimization Guide
  • ADLINK NuPRO-A40H Industrial Single Board Computer Hardware Deployment and BIOS Calibration Guide
  • ADLINK NuPRO-852 LGA775 Industrial Control Motherboard Maintenance Guide
  • ADLINK NuPRO-841 Industrial Motherboard Maintenance and Troubleshooting
  • ADLINK NuPRO-590 Series Socket7 Industrial Control Motherboard Maintenance Guide
  • Deployment and Troubleshooting of ADLINK MXE-5500 Series Industrial Control Computer
  • ADLINK MXE-200 Fanless Embedded Industrial Control Computer Deployment Guide
  • ADLINK cPCI-6770 Series CompactPCI Motherboard Maintenance Guide
  • ADLINK NuPRO-A301 Industrial Motherboard Troubleshooting Manual
  • ADLINK NuPRO-965 SHB Debugging and Maintenance Complete Manual
  • ADLINK NuPRO-935A Industrial Motherboard Debugging and Maintenance Guide
  • ADLINK NuPRO-865 Single Board Computer Hardware Troubleshooting Guide
  • ADLINK NuPRO-840 P4 Industrial SBC Architecture Maintenance
  • ADLINK NuPRO-770 Full length SBC Configuration and Maintenance
  • ADLINK NuPRO-595 Industrial Half length SBC Motherboard Configuration and Maintenance Guide
  • ADLINK cPCI-6840 Series Single Board Computer Installation, Configuration, and Maintenance Guide
  • Foxboro 43AP Pneumatic Controller Technical Specifications and Selection Guide
  • ADLINK cPCI-3720: 3U CompactPCI Low Power Pentium III CPU Module
  • ADLINK NuPRO-E47: PICMG 1.3 13th Generation Core Industrial SHB
  • ADLINK NuPRO-E43: PICMG 1.3 Core 7th Generation Industrial SHB
  • ADLINK NuPRO-780 PICMG Bus Core CPU Card
  • ADLINK cPCI-6965 6U CompactPCI Core Dual Core Single Board Computer
  • ADLINK USB/LPCI/LPCIe-3488A GPIB Interface Card Selection and Application Guide
  • Rittal SK 3241.700 Blue e+Cabinet Fan Filter Unit
  • ADLINK CPCI-8168 8-Axis Motion Control Card and HSL Network Integration Solution
  • ADLINK PCIe-PXIe-8638 High Speed PXIe Bus Expansion Scheme
  • ADLINK PCIe GIE7x Poe+Frame Grabber Hardware and Power Management Detailed Explanation
  • ADLINK PCIe-7396 Digital I/O Card Deployment Guide
  • ADLINK PCI-8164 Advanced Motion Control Card Deployment Guide
  • ADLINK PCI-8154 Motion Control Card Deployment Guide
  • ADLINK PCI-8134 Motion Control Card Deployment Guide
  • ADLINK NuPRO-E42 Industrial Control Motherboard Deployment Guide
  • ADLINK MXC-6600 Embedded Platform Deployment Guide
  • ADLINK MXC-6000 Industrial Control Computer Deployment and Optimization Guide
  • ADLINK MXC-2300 Embedded System Deployment Guide
  • ADLINK MCM-204 Edge DAQ Deployment Configuration Guide
  • ADLINK MCM-100/102 Deployment Calibration Guide
  • Deployment and Performance Optimization of ADLINK MXC-6400 Industrial Control Computer
  • Selection and Deployment of ADLINK Matrix Series Industrial Control Computers
  • российские промышленные новые машины.Наш отдел дебютировал в 2026 году в России Международная промышленная ярмарка INNOPROM
  • Deeply cultivating the Eurasian industrial market, linking new industrial opportunities between China and Russia
  • Deployment and troubleshooting of ADLINK GIE64+PoE acquisition card
  • Honeywell UMS Security System Troubleshooting Guide
  • Honeywell Expert Series C I/O Troubleshooting Guide
  • ADLINK EOS-1200 Vision System Deployment and Troubleshooting
  • ADLINK DLAP-5200 series AI engine deployment and optimization
  • ADLINK DLAP-4000 Deployment and BIOS Optimization
  • ADLINK Matrix MXC-2000 Deployment and Troubleshooting
  • ADLINK DAQe-2000 series acquisition card calibration and synchronization
  • ADLINK cPCI-6520 Core i7 Processor Blade Engineering Application Guide
  • ADLINK CM1-86DX3 PC/104 Embedded Single Board Computer Engineering Application Guide
  • Honeywell DC1000 Series PID Temperature Controller Engineering Application Guide
  • ALSTOM MiCOM C264 Substation Controller Engineering Application Guide
  • EMERSON AMS 2140 Practical Guide for On site Dynamic Balance and Vibration Analysis
  • ADLINK NuPRO-E320 motherboard deployment and tuning guide
  • ADLINK NuPRO-800 Dual PIII Industrial SBC Maintenance and Upgrade Guide
  • ADLINK NuPRO-598 SBC Maintenance Practical Guide
  • ADLINK MXC-6300 Fanless Embedded Industrial Control Computer Deployment Guide
  • ADLINK Express-BASE7 Carrier Board Quick Deployment and Debugging Guide
  • ADLINK DLAP-211 Edge AI Platform Selection and Deployment Guide
  • ADLINK 7230 Series Isolation DIO Card Selection and Engineering Application Guide
  • ADLINK cPCI-6965 SBC Embedded Installation and BIOS Tuning Guide
  • ADLINK 7200 Series High Speed DIO Card Practical Guide
  • ADLINK DLAP Series Edge AI Acceleration Platform Selection and Deployment Practical Guide
  • DEIF TCM-2 thyristor control module: Wind power cut in control engineering guide
  • DEIF MVR-200 Medium Voltage Relay: Installation and Wiring Engineering Guide
  • DEIF MDR-2 Differential Relay: Engineering Guide for Generator Differential Protection
  • DEIF Delomatic 3 AOM: Engineering Guide for Analog Output Modules
  • DEIF AGI 400 Graphic Interface: Ship and Industrial HMI Solution
  • DEIF BRW-1 Marine Instruments: Installation and Calibration Guide for Offshore Bridge Indicators
  • DEIF AGC 200 Controller: Quick Deployment and Configuration Guide for Generator Sets
  • DEIF AGC-2 Controller: The Ultimate Guide to Automatic Control and Protection of Generator Sets
  • ABB SPA-ZC400 Gateway: REM54x Access to IEC 61850 Ultimate Engineering Guide
  • ABB REM 543/545 Terminal
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module
  • Beckwith M-3520 Interconnection Protection Relay
  • Beckwith M-3430 Generator Protection Relay
  • Beckwith M-2293B adapter panel replacement GE regulator guide
  • Selection and Networking of Beckwith M-2001C Digital Voltage Regulating Controller
  • Beckwith M-2001B Digital Voltage Regulating Controller
  • Beckwith M-0388/M-0389 Synchronous Inspection Relay Application Guide
  • Beckwith M-0193B Synchronizer Debugging and System Integration Guide
  • Beckwith M-0115A Parallel Balance Module Debugging Guide
  • Beckwith M-0067E On Load Voltage Regulating Controller Selection and Debugging Guide
  • Debugging and Fault Handling of Beckwith M-4272 Digital Busbar Conversion System
  • Beckwith M-3311A Transformer Protection Relay Debugging Guide
  • Beckwith M-3425A Generator Protection Relay Debugging Guide
  • Setting and troubleshooting of Basler BE1-27/59 voltage relay
  • Debugging and troubleshooting of Basler AVC63-12/AVC125-10 voltage regulator
  • Basler L301kc Line Array Camera Technology and Troubleshooting
  • Selection and Debugging of Basler CBS 212A Current Boosting System
  • Selection and commissioning of Basler BE3-25 synchronous inspection relay
  • Basler BE1-32R/32O/U Direction Power Relay Setting and Testing Guide
  • Basler PRS 250 Synchronous Relay Maintenance and Replacement Guide
  • Basler piA2400-17gc Industrial Camera Replacement and Optimization Guide
  • Basler BE1-11g Generator Protection System