Description
<span style="font-size: 18px; font-family: arial;">LUBE GMN-10-200-CB2-7L Lubricator Grease Pump</span>

LUBE GMN-10-200-CB2-7L Lubricator Grease Pump Sumitomo SA175144A3

Overview

The LUBE GMN-10-200-CB2-7L Lubricator Grease Pump is a centralized lubrication component designed for industrial machinery and compatible Sumitomo equipment. It is identified by the GMN-10-200-CB2-7L model reference and the Sumitomo SA175144A3 part number. The pump delivers grease to multiple lubrication points through a distribution system. This helps reduce friction, wear, and heat in bearings, slides, gears, and other moving parts. Centralized lubrication improves maintenance efficiency because one pump can serve several points on a machine. The GMN series is known for reliable pump operation and controlled grease delivery. It is used in machine tools, injection molding machines, printing presses, and other production equipment where consistent lubrication is important.

Pump Function and Operation

The lubricator pump draws grease from a reservoir and delivers it under pressure to a main line. The line connects to progressive distributors or metering devices that divide the grease among lubrication points. The pump may operate on a timed cycle or be controlled by the machine sequence. A pressure relief valve helps protect the system from overpressure. The pump element moves grease with a positive displacement action, which supports consistent output. The reservoir stores enough grease for a defined operating period. Low level indicators or sensors may alert the operator when grease needs to be added. Proper priming and venting are important during setup. When the pump operates correctly, each lubrication point receives the required amount of grease.

Grease Delivery and System Design

Centralized grease systems are designed to deliver lubricant to points that are difficult to reach manually. The GMN-10-200-CB2-7L pump supports this by producing the pressure needed to move grease through long lines and distributors. The system may include filters, fittings, and high pressure hoses. Grease type and consistency affect pump performance. The correct grease should be selected for the application temperature and load. Contamination should be avoided because particles can block distributors and damage pump elements. The pump should be mounted securely and protected from vibration and impact. Regular inspection of lines and fittings helps prevent leaks and pressure loss. A well designed system improves machine reliability and reduces unplanned downtime.

Compatibility and Installation

The LUBE GMN-10-200-CB2-7L pump is associated with the Sumitomo SA175144A3 reference for compatible machinery. Technicians should confirm the voltage, control signal, and mounting arrangement before installation. The pump should be installed in a location that allows easy access for grease filling and service. Wiring should follow the machine manufacturer recommendations. Tubing and fittings should be clean and tightened to the correct torque. The system should be primed and tested for proper pressure and grease flow. Each distributor should be checked to confirm that all lubrication points receive grease. Following approved installation procedures helps ensure reliable operation and long service life.

Applications

The LUBE GMN-10-200-CB2-7L Lubricator Grease Pump is suitable for many industrial applications. It is used in machine tools, injection molding machines, packaging equipment, printing presses, and automated assembly lines. In these applications, centralized lubrication reduces manual work and improves consistency. The pump helps extend bearing life and reduces wear on slides and gears. It also helps maintain machine accuracy and product quality. For maintenance teams, the pump simplifies lubrication schedules and improves record keeping. For operators, reliable lubrication supports smooth machine operation and reduces unexpected stoppages. The Sumitomo SA175144A3 reference makes it relevant to compatible Sumitomo systems.

Maintenance and Care

Regular maintenance helps ensure reliable pump performance. The grease reservoir should be kept filled with the correct lubricant. Contamination should be prevented by cleaning the fill area before opening. Filters and strainers should be cleaned or replaced as recommended. The pump should be checked for unusual noise, vibration, and leaks. Pressure and cycle time should be monitored to detect changes. Distributors should be inspected for blockage or wear. Lines and fittings should be checked for damage and tightness. If a lubrication point stops receiving grease, the distributor or line may require service. Following a scheduled maintenance program helps prevent machine damage and extends equipment life.

Conclusion

The LUBE GMN-10-200-CB2-7L Lubricator Grease Pump with Sumitomo SA175144A3 compatibility is a practical component for centralized lubrication systems. It provides controlled grease delivery, reliable pump operation, and support for multiple lubrication points. Its design helps reduce wear, improve maintenance efficiency, and support consistent machine performance. Correct installation, clean grease, and regular maintenance help ensure dependable service. For industrial machinery and compatible Sumitomo equipment, this lubricator pump is a valuable part of the lubrication system.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Advantest R6144 Programmable DC Voltage/Current Source (Calibration Source) Calibration and Maintenance
  • Aerotech UNIDEX 100/U100i single axis motion controller
  • Aerotech Ndrive MP Ultra Compact PWM Digital Servo Driver
  • Aerotech Ndrive HPe 10/20/30 High Performance PWM Digital Servo Drive
  • Aerotech Ndrive HLe maintenance replacement
  • Aerotech Ndrive CP maintenance replacement
  • Aerotech Ndrive Linear Drive Selection
  • Aerotech NDrive HL linear drive maintenance replacement
  • Aerotech NDrive HP 10/20/30 Maintenance and Replacement
  • Aerotech NDrive CP10 Servo Drive Guide
  • SIGMATEK TAE1941 Display Unit Replacement and Troubleshooting
  • SIGMATEK TAE151 Replacement and Troubleshooting
  • SIGMATEK AKM Servo Motor Replacement and Troubleshooting Guide
  • SIGMATEK S-DIAS Control System Replacement and Upgrade Guide
  • SIGMATEK ETT Series HMI Replacement and Selection Guide
  • SIGMATEK DIAS Drive 310-23 servo amplifier
  • SIGMATEK CCP 521 C-DIAS processor module
  • Megmeet L6 electric drive troubleshooting
  • Sysmex XN-1000/2000 Technical Guide
  • Sysmex XN-L blood analyzer maintenance and troubleshooting
  • Troubleshooting and Maintenance of Sysmex XN-9000
  • LTI Motion ServoOne PROFIBUS/PROFINET Troubleshooting and Replacement
  • Micro Innovation MICRO GF1 Touch Screen Troubleshooting and Replacement
  • Troubleshooting and Replacement of Micro Innovation WINbloc Distributed I/O System
  • MICRO PANEL GS-2 Troubleshooting and Debugging
  • LTi Synchronous Motor LST/LSH Replacement Selection Guide
  • Fault diagnosis of LTi CDE/CDB3000
  • Maintenance and troubleshooting of ENOTEC SILOTEC 8000 silo analyzer
  • ENOTEC ENSITU 7000 Oxygen Analyzer
  • ENOTEC COMTEC 6000 ATEX GasEx Analyzer Maintenance, Calibration, and Troubleshooting Guide
  • ENOTEC Analyzer Family Selection Guide
  • ENOTEC OXITEC 500E Oxygen Analyzer
  • KUKA KR CS Box-2 Compact Controller for Four Axis SCARA Robot
  • KUKA KR C5 slim-2 Robot Controller
  • KUKA KR C5 micro KSS troubleshooting
  • KUKA KR C5 micro debugging and troubleshooting
  • KUKA KR C5 Controller Assembly and Troubleshooting
  • KUKA KR C5 Cabinet Assembly and Troubleshooting
  • KUKA KR C4 Smallsize-2 Debugging Guide
  • KUKA KR C4 Midsize Assembly Guide
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications
  • Bonfiglioli 300 series reducer installation, maintenance, and troubleshooting guide
  • Selection and integration guide for Bonfiglioli R3 series planetary gearboxes in primary crushing equipment
  • Bonfiglioli C-series ATEX gearbox selection and explosion-proof application guide
  • Bonfiglioli Vectron EM-ENC-05 Full Function Expansion Module Integration Guide
  • Bonfiglioli Vectron EM-ENC-04 Multi functional Expansion Module Complete Configuration Guide
  • Bonfiglioli Vectron EM-ENC-03 Second Encoder Interface and System Bus Expansion Guide
  • Bonfiglioli Vectron EM-ENC-02 Expansion Module Integration and Encoder Interface Guide
  • Bonfiglioli Vectron CM-CAN CANopen Communication Configuration and DS402 Control Guide
  • Bonfiglioli Vectron EM-SYS System Bus Networking and Virtual Link Configuration Guide
  • Bonfiglioli Vectron CM-PDP Profibus DP Configuration and Debugging Guide