Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • OMRON NX-OD5256 Output Module
    ❤ Add to collection
  • OMRON NX-OD5256 Output Module

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥42745.00
      ¥46437.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:11.570KG
    • Quantity:
    • (Inventory: 6543)
Description
<span style="font-family: arial; font-size: 18px;">OMRON NX-OD5256 Output Module</span>

OMRON NX-OD5256 Digital Output Module for NX I/O Systems

The OMRON NX-OD5256 is a high-density digital output module designed for the NX series I/O system. This module provides 16 solid state PNP output points in a compact 12 mm wide housing, making it ideal for applications requiring numerous discrete output signals within constrained panel space. The NX I/O system serves as the distributed I/O solution for Omron NJ-series and NX-series machine automation controllers as well as EtherCAT Coupler configurations, offering modular flexibility for diverse automation requirements.

Output Specifications

The NX-OD5256 delivers 16 digital outputs of the PNP type, compatible with 24 VDC loads. Each output point is rated at 0.5 A, with a total unit current capacity of 4 A when all outputs are active simultaneously. The permitted voltage range extends from 15.0 to 28.8 VDC, accommodating typical industrial power supply variations. The outputs are solid state, providing faster switching speeds and longer operational life compared to electromechanical relay outputs. The ON delay time is 0.5 ms maximum, and the OFF delay time is 1 ms maximum, ensuring responsive control for time-critical applications.

Each output channel includes built-in short-circuit protection, safeguarding the module and connected loads against fault conditions. This protection feature automatically limits current during overload events and recovers when the fault is cleared, reducing downtime and eliminating the need for external fusing on each channel.

Physical and Installation Characteristics

The NX-OD5256 features a width of only 12 mm, making it one of the most space-efficient digital output modules available. The dimensions are 104.5 mm in height and 80.1 mm in depth, with a weight of approximately 70 g. Mounting is accomplished via DIN rail, conforming to standard industrial installation practices. The termination style employs screwless push-in connectors (spring terminal), enabling rapid wiring without specialized tools. The connection method is 1-wire, simplifying field wiring requirements.

The module is rated IP20 for degree of protection, suitable for installation within protected control panels. Operating temperature range is 0 to 55°C, accommodating typical industrial environments. Storage temperature spans from -10 to 75°C. The NX-OD5256 complies with CE, cULus, C-Tick, KC, Lloyd, and NK standards, ensuring global acceptance for industrial automation projects.

Integration with NX Systems

The NX-OD5256 operates on the NX I/O bus, communicating with the system CPU unit or EtherCAT Coupler. The module supports standard I/O response processing including free-running and synchronous I/O refreshing modes. The signal processing types available are standard speed, suitable for most general-purpose output applications. The module does not provide built-in communication ports, relying on the system bus for all data exchange.

For power distribution, the NX-OD5256 draws its operating power from the NX bus power supply. The unit does not include dedicated IOV (V+) or IOG (V-) terminals, as power is supplied through the system bus and the I/O power connection unit. The module can be used in safety applications up to SIL2 when configured with suitable system architecture, though the module itself is not certified for functional safety independently.

When combined with compatible power connection units such as NX-PC0010, NX-PC0020, or NX-PC0030, the NX-OD5256 integrates seamlessly into comprehensive NX I/O systems alongside digital input, analog, and specialty modules. The module works with the NX-series building block for PC-based machine control platforms, enabling flexible system configurations ranging from small distributed I/O points to large-scale machine control networks.

Applications and Advantages

The OMRON NX-OD5256 is well-suited for applications requiring multiple discrete outputs including machine control, actuator driving, solenoid activation, indicator light control, and interlocking with peripheral devices. Its compact width allows high channel counts in minimal panel space, reducing overall system footprint. The spring termination eliminates screw tightening, reducing installation time and improving reliability in vibration-prone environments.

With no moving contacts, the solid-state design provides maintenance-free operation for the life of the module. The short-circuit protection safeguards both the module and field wiring, enhancing system robustness. The NX-OD5256 represents an efficient solution for machine builders and system integrators seeking reliable, compact, and cost-effective digital output expansion for Omron automation platforms.


IS220PHRAH1A HART ANALOG I/O PACK

IS200EXAMG1B EXCITER ATTENUATION MODULE
FC-PSU-UNI2450U-V2.1 POWER SUPPLY
PXIE-2593 780587-93 PXI RF Multiplexer Switch Module
IS200TDBTH6AAA Gas turbine control card
IS200JPDHG1AAA Mark VI Power Distribution Card
IS200TREAH2ACC EMERGENCY TRIP TERMINAL BOARD
IS215WEMAH1A WIND AND SOLAR ENERGY MAIN I/O CONTROL BOARD
PXIE-4302 PXI Analog Input Module
5X00785G05 Power Distribution Module
LMC101CAA10000 motion controller transistor sercos compact Ethernet
3500/53M 288062-01 3500/53 Electronic Overspeed Detection System
3500/15-05-05-R0 Power Supply
IS200VRTDH1DAC VMR GENERAL ELECTRIC RTD BOARD
REM620 NBMNACAAABC1BNN11G Motor protection and control
IS200TVBAH1AAA VIBRATION TERMINAL BOARD
1900/65A-00-00-01-00-00 General Purpose Equipment Monitor
PR6425/010-130+CONO21/915-040 Eddy Current Signal Converter
490NRP25400 Enhancing Connectivity with Fiber Optic Repeater
2094-BC07-MO5-S Kinetix 6000 Drive component
IS200TRPGH1BDE PRIMARY TRIP TERMINAL BOARD
DS2020FECNRX020A FIELD EXCITER BOARD
900C75S-0360-00 ControlEdge HC900 IO Modules
IS2020RKPSG3A Mark VI VME Rack Power Supply
XV-102-B6-35TQR-10-PLC Touch panel 
  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ADLINK cPCI-3720: 3U CompactPCI Low Power Pentium III CPU Module
  • ADLINK NuPRO-E47: PICMG 1.3 13th Generation Core Industrial SHB
  • ADLINK NuPRO-E43: PICMG 1.3 Core 7th Generation Industrial SHB
  • ADLINK NuPRO-780 PICMG Bus Core CPU Card
  • ADLINK cPCI-6965 6U CompactPCI Core Dual Core Single Board Computer
  • ADLINK USB/LPCI/LPCIe-3488A GPIB Interface Card Selection and Application Guide
  • Rittal SK 3241.700 Blue e+Cabinet Fan Filter Unit
  • ADLINK CPCI-8168 8-Axis Motion Control Card and HSL Network Integration Solution
  • ADLINK PCIe-PXIe-8638 High Speed PXIe Bus Expansion Scheme
  • ADLINK PCIe GIE7x Poe+Frame Grabber Hardware and Power Management Detailed Explanation
  • ADLINK PCIe-7396 Digital I/O Card Deployment Guide
  • ADLINK PCI-8164 Advanced Motion Control Card Deployment Guide
  • ADLINK PCI-8154 Motion Control Card Deployment Guide
  • ADLINK PCI-8134 Motion Control Card Deployment Guide
  • ADLINK NuPRO-E42 Industrial Control Motherboard Deployment Guide
  • ADLINK MXC-6600 Embedded Platform Deployment Guide
  • ADLINK MXC-6000 Industrial Control Computer Deployment and Optimization Guide
  • ADLINK MXC-2300 Embedded System Deployment Guide
  • ADLINK MCM-204 Edge DAQ Deployment Configuration Guide
  • ADLINK MCM-100/102 Deployment Calibration Guide
  • Deployment and Performance Optimization of ADLINK MXC-6400 Industrial Control Computer
  • Selection and Deployment of ADLINK Matrix Series Industrial Control Computers
  • российские промышленные новые машины.Наш отдел дебютировал в 2026 году в России Международная промышленная ярмарка INNOPROM
  • Deeply cultivating the Eurasian industrial market, linking new industrial opportunities between China and Russia
  • Deployment and troubleshooting of ADLINK GIE64+PoE acquisition card
  • Honeywell UMS Security System Troubleshooting Guide
  • Honeywell Expert Series C I/O Troubleshooting Guide
  • ADLINK EOS-1200 Vision System Deployment and Troubleshooting
  • ADLINK DLAP-5200 series AI engine deployment and optimization
  • ADLINK DLAP-4000 Deployment and BIOS Optimization
  • ADLINK Matrix MXC-2000 Deployment and Troubleshooting
  • ADLINK DAQe-2000 series acquisition card calibration and synchronization
  • ADLINK cPCI-6520 Core i7 Processor Blade Engineering Application Guide
  • ADLINK CM1-86DX3 PC/104 Embedded Single Board Computer Engineering Application Guide
  • Honeywell DC1000 Series PID Temperature Controller Engineering Application Guide
  • ALSTOM MiCOM C264 Substation Controller Engineering Application Guide
  • EMERSON AMS 2140 Practical Guide for On site Dynamic Balance and Vibration Analysis
  • ADLINK NuPRO-E320 motherboard deployment and tuning guide
  • ADLINK NuPRO-800 Dual PIII Industrial SBC Maintenance and Upgrade Guide
  • ADLINK NuPRO-598 SBC Maintenance Practical Guide
  • ADLINK MXC-6300 Fanless Embedded Industrial Control Computer Deployment Guide
  • ADLINK Express-BASE7 Carrier Board Quick Deployment and Debugging Guide
  • ADLINK DLAP-211 Edge AI Platform Selection and Deployment Guide
  • ADLINK 7230 Series Isolation DIO Card Selection and Engineering Application Guide
  • ADLINK cPCI-6965 SBC Embedded Installation and BIOS Tuning Guide
  • ADLINK 7200 Series High Speed DIO Card Practical Guide
  • ADLINK DLAP Series Edge AI Acceleration Platform Selection and Deployment Practical Guide
  • DEIF TCM-2 thyristor control module: Wind power cut in control engineering guide
  • DEIF MVR-200 Medium Voltage Relay: Installation and Wiring Engineering Guide
  • DEIF MDR-2 Differential Relay: Engineering Guide for Generator Differential Protection
  • DEIF Delomatic 3 AOM: Engineering Guide for Analog Output Modules
  • DEIF AGI 400 Graphic Interface: Ship and Industrial HMI Solution
  • DEIF BRW-1 Marine Instruments: Installation and Calibration Guide for Offshore Bridge Indicators
  • DEIF AGC 200 Controller: Quick Deployment and Configuration Guide for Generator Sets
  • DEIF AGC-2 Controller: The Ultimate Guide to Automatic Control and Protection of Generator Sets
  • ABB SPA-ZC400 Gateway: REM54x Access to IEC 61850 Ultimate Engineering Guide
  • ABB REM 543/545 Terminal
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module
  • Beckwith M-3520 Interconnection Protection Relay
  • Beckwith M-3430 Generator Protection Relay
  • Beckwith M-2293B adapter panel replacement GE regulator guide
  • Selection and Networking of Beckwith M-2001C Digital Voltage Regulating Controller
  • Beckwith M-2001B Digital Voltage Regulating Controller
  • Beckwith M-0388/M-0389 Synchronous Inspection Relay Application Guide
  • Beckwith M-0193B Synchronizer Debugging and System Integration Guide
  • Beckwith M-0115A Parallel Balance Module Debugging Guide
  • Beckwith M-0067E On Load Voltage Regulating Controller Selection and Debugging Guide
  • Debugging and Fault Handling of Beckwith M-4272 Digital Busbar Conversion System
  • Beckwith M-3311A Transformer Protection Relay Debugging Guide
  • Beckwith M-3425A Generator Protection Relay Debugging Guide
  • Setting and troubleshooting of Basler BE1-27/59 voltage relay
  • Debugging and troubleshooting of Basler AVC63-12/AVC125-10 voltage regulator
  • Basler L301kc Line Array Camera Technology and Troubleshooting
  • Selection and Debugging of Basler CBS 212A Current Boosting System
  • Selection and commissioning of Basler BE3-25 synchronous inspection relay
  • Basler BE1-32R/32O/U Direction Power Relay Setting and Testing Guide
  • Basler PRS 250 Synchronous Relay Maintenance and Replacement Guide
  • Basler piA2400-17gc Industrial Camera Replacement and Optimization Guide
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection
  • Basler SSR Static Voltage Regulator: A Complete Guide to Debugging and Troubleshooting
  • Basler SR4A/SR8A Voltage Regulator: Detailed Debugging and Troubleshooting Explanation
  • Basler BE2000E Voltage Regulator: Replacement and Application Details
  • Basler DECS-2100 Excitation System: Modular Upgrade and Engineering Application
  • Basler BE1-851 Overcurrent Protection System: A Complete Guide to Professional Debugging and Troubleshooting
  • Basler APR 63-5 Voltage Regulator: Professional Debugging and Troubleshooting Guide for Industrial Generator Excitation Systems
  • Basler BE1-FLEX Protection System: A Complete Guide to Professional Installation, Configuration, and Troubleshooting
  • Debugging and Testing of Basler BE1-700 Relay
  • Basler BE1-87B busbar differential setting test
  • Basler BE1-40Q demagnetization relay setting test
  • Basler BE1-60 Voltage Balance Relay Setting Test
  • Basler BE1-47N Relay Field Setting and Testing Guide
  • Basler BE1-81O/U Frequency Relay: On site Debugging and Protection Configuration Guide
  • Basler BE1-11f Feedline Protection System Debugging and Troubleshooting Guide
  • Basler DECS-250 Excitation System: Installation, Configuration, and Troubleshooting Practice Guide
  • Basler DECS-100 Digital Excitation System Debugging Guide
  • Application Guide for Basler BE1-BPR Circuit Breaker Protection Relay
  • Basler BE1-50/51B-255 Replacement CO Relay Guide
  • Basler BE1-25 synchronous inspection relay principle and testing
  • Basler BE1-51 Time Overcurrent Relay Debugging Guide
  • Practical Guide to Basler DECS-300 Digital Excitation System
  • Mitsubishi FX Series PLC Data Communication Practical Manual
  • Selection of Hirschmann cSCALE S6/C8 Mobile Safety Controller
  • Hirschmann OZD Profi G12D repeater explosion-proof installation configuration
  • Hirschmann OCTOPUS OS20/24 Switch Installation Power Supply