Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • Datalogic SG-BWS-T4-MT Safety Control Unit Category 4
    ❤ Add to collection
  • Datalogic SG-BWS-T4-MT Safety Control Unit Category 4

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥52375.00
      ¥54375.00
      ¥52375.00
      ¥52375.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:12.100KG
    • Quantity:
    • (Inventory: 7458)
Description
<span style="font-size: 18px; font-family: arial;">Datalogic SG-BWS-T4-MT Safety Control Unit | Category 4</span>

Datalogic SG-BWS-T4-MT Safety Control Unit

The Datalogic SG-BWS-T4-MT is a safety control unit designed for managing machine guarding applications with Category 4, SIL 3, and PL e safety ratings. This compact unit interfaces with up to four pairs of safety photocells or two pairs of light beam protectors, providing reliable safety monitoring for access control, body protection, and perimeter guarding. The SG-BWS-T4-MT includes double muting functionality, allowing temporary suspension of the safety function during workpiece passage while maintaining safety integrity. The plastic-housed unit is designed for OMEGA/DIN rail mounting and features 16 screw clamps for secure wiring connections.

Technical Specifications

SpecificationDetail
Product FamilySG-BWS (Safety Guard)
ModelSG-BWS-T4-MT
Order Number957051010
Safety CategoryType 4 (EN 61496-1)
Performance LevelPL e (EN ISO 13849-1)
SIL LevelSIL 3 (IEC 61508, IEC 62061)
PFHd1.74 × 10^-9 per hour
MTTFd428 years
Power Supply24 VDC ± 15%
Power Consumption3.8 W max
Output Contacts2 PNP OSSD safety outputs + 2 normally open relay outputs
Response Time39 ms max (includes photocell response time)
Short Circuit Protection1.4 A max
Muting FunctionDouble muting
Housing MaterialNylon PA66
MountingOMEGA/DIN rail
Operating Temperature0°C to 55°C
Protection DegreeIP20

Key Features and Benefits

  • Safety Integrity Certification: The SG-BWS-T4-MT meets the highest safety certification levels, including Type 4 according to EN 61496-1 for electro-sensitive protective equipment, SIL 3 according to IEC 61508/IEC 62061 for functional safety, and PL e according to EN ISO 13849-1 for performance level classification. These certifications allow the unit to be used in applications requiring the highest risk reduction level, up to and including the protection of personnel from serious hazard exposure.

  • Double Muting Functionality: The double muting feature allows temporary, controlled suspension of the safety function while workpieces pass through the guarded area. This eliminates the need for operators to manually bypass the safety system for material throughput, improving production efficiency while maintaining safety integrity. The double muting configuration provides redundancy and ensures that muting only occurs when both muting sensor conditions are satisfied simultaneously, preventing unsafe bypass conditions.

  • Multiple Sensor Compatibility: The control unit accepts inputs from up to four pairs of safety photocells and up to two pairs of external light beam protectors, offering flexibility for complex guarding configurations. The unit is compatible with Datalogic S5-ST, SL5-ST, and S300 series safety photocells, enabling integration with existing safety device inventories.

  • Dual OSSD and Relay Outputs: The SG-BWS-T4-MT provides two PNP OSSD (Output Signal Switching Device) solid-state safety outputs for controlling external safety circuits, along with two normally open relay outputs. The OSSD outputs are short-circuit protected and achieve a response time of 39 ms maximum, ensuring rapid machine stopping upon safety device actuation.

Functional Overview

The SG-BWS-T4-MT monitors the status of connected safety photocells and external beam protectors. Under normal conditions, the safety outputs are active, enabling machine operation. If the guarded zone is interrupted, the unit disables the OSSD outputs within 39 ms, signaling the machine to stop. When double muting is configured, the unit temporarily suspends the safety function during workpiece transport. The unit also monitors muting sensor logic and will reset safety functions only when the muting sequence completes correctly.

Compatibility and Integration

The SG-BWS-T4-MT supports selection of manual/automatic restart and External Device Monitoring (EDM). It is designed for use in body protection and perimeter access control systems. The control unit is suitable for integration with various safety components including light curtains, safety mats, and two-hand control devices.

Typical Applications

The Datalogic SG-BWS-T4-MT safety control unit is deployed in applications requiring high-integrity machine guarding:

  • Automated assembly lines with workpiece transfer through guarded zones — double muting allows product passage without operator intervention

  • Palletizing and packaging machinery with conveyor feed points requiring periodic safety function suspension

  • Material handling systems with inline inspection stations requiring beam interruption on product entry

  • Robotic work cells with automated part loading/unloading through light curtains

  • Packaging machines where safety doors are replaced by light beam protection with muting for product flow

  • Warehouse automated storage and retrieval system access protection

  • Metal stamping and press feeding systems requiring muting during material feed cycles


Installation and Configuration

The SG-BWS-T4-MT mounts onto OMEGA or standard 35 mm DIN rail inside a control enclosure. Power supply requires 24 VDC ± 15% within the specified power consumption limit. Safety photocells connect to the 16 screw clamp terminals per the wiring diagram in the instruction manual. LEDs on the front display provide status and diagnostic information. Configuration includes selecting single or double muting, enabling or disabling EDM and auto/manual restart.

Maintenance and Reliability

The SG-BWS-T4-MT does not require special servicing under normal conditions. The front optic surfaces of any photocells must be cleaned regularly to prevent reduction of operative distance. Datalogic guarantees the product through a three-year factory warranty. The unit has a MTTFd of 428 years and PFHd of 1.74 × 10^-9 per hour, supporting safety system validation calculations for machine builders and safety engineers.

Conclusion

The Datalogic SG-BWS-T4-MT safety control unit provides high-integrity machine guarding with Type 4, SIL 3, PL e certification. Its double muting capability, multiple photocell inputs, PNP OSSD outputs, and compatibility with Datalogic safety sensors make it a suitable solution for applications requiring personnel protection with automated workpiece transfer.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice
  • PULS QS40.241 Power Supply Practical Guide
  • Eaton XV-102-L Touchscreen Installation Guide
  • Omron FZ5 Vision System Selection and Configuration Guide
  • Schneider TSX47 series PLC selection
  • ABB CS31 distributed debugging
  • OMRON H8PR electronic cam debugging
  • OMRON MX2 frequency converter debugging
  • GP477R Engineering Installation
  • Siemens AS-i SlimLine Diagnostic Guidelines
  • OMRON NS Series PT Remote Access
  • OMRON Z4M sensor precision measurement
  • HIMMERWERK SINUS High Frequency Induction Heating Selection
  • OMRON CP1E PLC Practical Selection Guide
  • OMRON ZFX-C Vision Sensor in Practical Use
  • OMRON ZFV Intelligent Sensor Practical Guide
  • OMRON CJ Series PLC Practical Guide
  • Murr SIRCO Isolation Switch Selection Guide
  • OMRON ZFX Vision Sensor Engineering Practice
  • REER ULISSE UNC Security Light Curtain Practice
  • Siemens S5-90U/95U Fault Diagnosis and Advanced Programming
  • OMRON CPM2C system fault diagnosis and maintenance
  • Yaskawa ∑ - V Servo Drive Debugging Guide
  • OMRON CP1H PLC Practical Manual
  • OMRON K-type PLC Maintenance Guide
  • PEPPERL+FUCHS SLVA-4Kplus Safety Light Curtain Guide
  • Yaskawa ∑ - II Servo Drive Debugging Guide
  • Yaskawa VS-616PC5/P5 frequency converter practical application
  • OMRON 3G3SV Inverter Practical Manual
  • Pro face GP370 Complete Guide
  • OMRON FQ2 Smart Camera Selection Guide
  • Practical Guide to Sony SH800 Sorter
  • OMRON Cam Positioner Complete Guide
  • KEB F4 Inverter Debugging Guide
  • OMRON CJ series PLC operation and maintenance essentials
  • Essentials of Schneider C60H-DC DC DC Protector
  • OMRON 3G3MV Inverter Practical Guide
  • Essentials of OMRON CQM1H PLC System
  • Essentials of ARD Elevator Emergency Rescue Device
  • SolaHD SDN-D rail power supply
  • OMRON C200H PLC Troubleshooting and Programming Essentials
  • Allen Bradley 1336 PLUS Inverter Practical Guide
  • OMRON 3G3KV frequency converter
  • OMRON NSJ Integrated Controller
  • Megatiker M4 Circuit Breaker Maintenance
  • OMRON ZX laser sensor maintenance
  • Saia PCD1 Controller Maintenance Guide
  • OMRON NT Series HMI Replacement and Maintenance
  • Yaskawa F7 Driver Maintenance and Replacement
  • Rockwell 1494 switch selection replacement
  • Omron NA Series HMI Connection Guide
  • Eaton CV Series PLC System Upgrade and Diagnosis
  • Eaton XV-102 HMI Installation and Troubleshooting
  • Siemens SINUMERIK measurement cycle configuration
  • ELAU PacDrive C600 Controller Integration Guide
  • ELAU PacDrive SM Servo Motor Application and Maintenance Guide
  • Bently Nevada Orbit 60 System Upgrade and Troubleshooting Guide
  • YOKOGAWA STARDOM FCN-RTU Controller
  • Fireye InSight II Marine Flame Scanner
  • How to install ABB VSC vacuum contactor?
  • Rexroth Bosch Group VT2000 Proportional Amplifier
  • ALSTOM ALSPA series frequency converter
  • ABB SPACOM replaces REX615
  • Meggitt C327895 Gas Metering Valve Technology
  • Application of MOOG G77x servo valve
  • WOODWARD 2301E Digital Speed Controller
  • ABB UNITOL 1010/1020 AVR Compact IGBT Automatic Voltage Regulator
  • ABB UNITOL 6000 excitation system
  • Rexroth Bosch Group HNC100 Hydraulic Shaft Control
  • Lenze 8400 Inverter Debugging Guide
  • Panning Vacuum Sensor Maintenance Guide
  • SOGEVAC Rotary Disc Pump Maintenance Guide
  • THERMOVAC MEMS Vacuum Gauge Guide
  • TTR 101 Vacuum Gauge Troubleshooting Guide
  • Honeywell Beam Smoke Detector Guide
  • TURBOVAC Molecular Pump Maintenance Guide
  • Troubleshooting of Leuze electronic DDLS 200 optical transmission
  • Lam Harmonic Drive Quick Replacement Guide
  • LZS power replacement and troubleshooting
  • MTL2000 series isolation barrier
  • Temposonics GB Sensor
  • Temposonics R Series Magnetostrictive Displacement Sensor Depth
  • Original inventor of M ü ller Co ax AG coaxial valve
  • Murrelektronik Automation Solution Complete Solution
  • Nabtesco RV series high-precision gearbox
  • NACHI Robot Full Series
  • Electro hydraulic proportional directional flow valve
  • NEC FC-9801X Industrial Computer
  • Mark VIeS Security System
  • NI RIO Platform: Embedded Measurement and Control Solution Integrating Real time Processing and FPGA
  • NI sbRIO-9612 Single Board Controller
  • NI EPM high-performance DAQ cable
  • NI SCXI-1349 Adapter Connection Guide