Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

PRO-FACE XYCOM 1546 Heavy Industrial PC 1546-1020310130001

来源: | 作者:FAN | 发布时间 :2025-05-28 | 560 次浏览: | Share:
PRO-FACE XYCOM 1546 Heavy Industrial PC 1546-1020310130001
Product Overview
The 1546 and 1547 Node Box Industrial PCs offer a powerful, compact package for the factory floor and other harsh environments.
These node box industrial PCs feature an open architecture to meet a wide variety of applications that require both a powerful PC and a durable industrial enclosure.
The systems integrate a computer card cage, mass storage, and power supply in a truly industrial form.
The processor board combines all the functions of a complete PC/AT® compatible computer on a single industrially hardened circuit board.  


Standard Features  

The 1546 and 1547 units come standard with the following features:
AIM4 board
Wall or shelf mountable
Flash BIOS
SATA HD controller for up to 2 drives
Removable 40 GB SATA hard drive(s), rear access
AGP Video Controller, 4M of system DRAM, up to 32M
PCI local bus IDE controller (for CD/DVD and CF options)
Two 240 pin DDR2 DIMM sockets that support 256MB, 512MB, 1GB and 2GB options
Intel® Socket 478 Celeron® M or Pentium® M options up to 2.0GHz 400MHz or 533MHz front side bus depending on the processor type
1546 – Four AT bus expansion slots  
One PCI (8.0” max)
One PCI (9.0” max)
One ISA (9.0” max)
One PCI or ISA slot (9.0” max)
1547 – Four AT bus expansion slots  
One ½ length PCI
One full length PCI
One full length ISA
One full length PCI or ISA slot
IBM® PS/2® keyboard port and mouse port
Four serial COM ports, with three external ports configured as RS-232 and one configurable as either RS-232 or RS-422 or RS-485.
The fourth port is an internal header only and defaulted as disabled.


Parallel port  

VGA port
Four USB 2.0 ports
Legacy USB keyboard and mouse support
Legacy USB floppy, USB CDROM, and USB mass storage support
Two onboard Ethernet ports, one is a 10/100 BASE T and the other is 10/100/1000 BASE T
Microsoft Windows XP® operating system
Internal rear access Compact Flash (CF) interface
120/240 VAC 50/60Hz Auto switching power supply
UL Listed for use in Class I and Class II, Division 2 hazardous locations, Groups A, B, C, D, F, and G


Optional Features

Following are optional available features of the 1546 and 1547:
Higher capacity SATA hard drives and solid state drives  
Various CD/DVD drive options
Internal rear access floppy
Various processor speeds
Preinstalled Windows® 2000, or Windows XP® Professional
External 9000-USBF, USB floppy (requires Windows 2000, or XP)
CompactFlash™ options up to 4GB
2.5” Dual hard drives
2.5” RAID array support
24VDC power supply (on 1547 units only)
The figures and tables on the next several pages illustrate the internal and external components on the front and back panels of the unit to help you locate the features of the 1546 and 1547 Node Boxes.


Installation Overview
Warning
For installation in Hazardous Locations, review the Hazardous Locations
Installation section in this chapter before startup.  

The rugged design of the 1546 and 1547 Node Boxes allows it to be installed in most industrial environments.

The system is generally placed in a NEMA 4/4X/12 enclosure to protect against contaminants such as dust, and moisture.

Metal enclosures also help minimize the effects of electromagnetic radiation that nearby equipment can generate.

For Underwriters Laboratories (UL) compliance, the unit must be installed within a suitable fire enclosure.

Read the following sections carefully to be sure that you are complying with all the safety requirements.
Select a NEMA rated enclosure and place the unit to allow easy access to the system ports (see other sections in this chapter and Appendix A).
To assure a NEMA 4 seal choose an approved enclosure that has a 14-gauge(0.075 in/1.9 mm thick steel or 0.125 in/3.2 mm thick aluminum) front face.
Be sure to account for the unit’s depth when choosing the depth of the enclosure.
Create a mounting location in the enclosure (see System Mounting Dimensions).


Be sure to place the unit at a comfortable working level

Make sure the area around the mounting location is clean and free from metal burrs
Mount the unit position and properly secure the unit into the panel.
Tighten the fourteen #10 screws to 20 inch-pounds (2.597 Newton-meters /23Kgf cm).
Construct a power cable following the instructions in AC Power Cable in this chapter.
Attach one end of the power cord to the power receptacle on the unit and the other end to a properly grounded 115/230 VAC, 50-60 Hz outlet.
A ground path from the unit chassis to the enclosure chassis can be established using the 6-32 threaded ground point hole provided on the bottom panel of the unit
Turn on power to the system. The system will boot up the installed operating system.
Install the application software via a floppy drive, CD-ROM, or the network.


Additional aspects to take into account when mounting your 1546 and 1547 Node

Boxes:
Consider locations of accessories such as AC power outlets and lighting (interior lighting and windows) for installation and maintenance convenience
Prevent condensation by installing a thermostat-controlled heater or air 
  • Woodward 8440-1706 Industrial Control System Module
  • Woodward 8440-2052 H Synchronizer Load Share Module
  • Baldor KPD-TS12C-30E 12.1" Color TFT Touch Screen Ethernet HMI
  • Baldor KPD-TS10C-30E 10" Color TFT Touch Screen Operator Interface with Serial and Ethernet Interfaces
  • Baldor KPD-TS05C-30E 5.6" Color TFT Touch Screen with Serial and Ethernet Interface
  • Baldor KPD-TS05C-30 5.6 Inch Color TFT Touch Screen Serial Interface
  • Baldor KPD-TS05M-10 5.6" Monochrome Touch Screen Serial Interface HMI
  • Baldor KPD-TS03M-10 Monochrome Touch Screen Operator Interface
  • Baldor KPD-KG420-30 4x20 Graphic Display with 12 Function Keys - Serial Interface
  • Baldor KPD-KG420-20 4x20 Character Graphic Display Serial Interface
  • WOODWARD EASYGEN-3200-5 8440-1992 A Genset Controller
  • WOODWARD PEAK200-HVAC 8200-1501 C Version | Industrial Building Automation Controller
  • Woodward 8440-2052 easyGEN-3200 Genset Control Power Management
  • Woodward 8237-1246 + 5437-1119 Control System Module
  • WOODWARD SPM-D11 8440-1703 Overspeed Protection System Module
  • WOODWARD 8237-1369 Governor Control Module
  • Woodward 8237-1600 Digital Control Module
  • WOODWARD BUM60-1224-54-B-001-VC-A0-0093-0013-G003-0000 3522-1004 Industrial Control Module
  • WOODWARD 8200-1302 Genset Controller
  • Woodward 8901-457 Speed Control Module
  • WOODWARD 5501-465 Control Module
  • Woodward 5448-890 SPM-D10 Digital Control Module
  • WOODWARD 5437-1067A Turbine Governor Actuator
  • Woodward 8440-1666 B Digital Control Module
  • WOODWARD 8440-1706 A SPM-D11 Synchronous Phase Modulator Module
  • WOODWARD 5466-425 Programmable Automation Controller (PAC)
  • WOODWARD 5466-318- Industrial Gas Turbine Control Module
  • WOODWARD 5453-277 Digital Control Module
  • WOODWARD 5453-203 Digital Governor Control Module
  • WOODWARD 9907-1106 Pressure Converter
  • WOODWARD 5233-2089 Professional Industrial Control System Module
  • WOODWARD 9907-147 Power outage tripping overspeed protection system
  • WOODWARD 8237-1600 Digital Speed Control System
  • WOODWARD 8402-319 8402-119 microprocessor speed controller
  • Woodward 8237-1006 Digital Governor
  • WOODWARD 5501-471 Communication Module
  • WOODWARD 5466-258 Input/Output Module
  • WOODWARD 5501-467 Multi Protocol Communication Gateway and I/O Expansion Module
  • WOODWARD 5501-470 Digital microprocessor controller module
  • WOODWARD 9907-1200 Digital Governor
  • WOODWARD 8444-1067 High Performance Digital Microprocessor Controller Module
  • WOODWARD 8446-1019 Integrated Gas Engine Electronic Control System
  • WOODWARD 9907-162 Digital Engine Governor
  • WOODWARD 5466-316 Simulation Combination Module
  • WOODWARD 5464-414 Digital Speaker Sensor Module
  • XANTREX XFR40-70 DC power supply
  • XP POWER F8B6A4A6A6 power module
  • XP POWER F8B6D4A3G3 power supply
  • XYCOM XVME-674 VMEbus Single Slot CPU/Processor Module
  • XYCOM XVME-957 Circuit Board
  • XYCOM XVME-976 PC board computer
  • XYCOM XVME-530 8-Channel Isolated Analog Output Module
  • XYCOM Proto XVME-085 Bus Module
  • YAMAHA RCX40 4-AXIS ROBOT CONTROLLER
  • YAMATAKE EST0240Z05WBX00 touch screen display
  • YAMATAKE HD-CAOBS00 flowmeter
  • HIMA X-COM 01 Communication Module
  • HIMA HIMax X-AO 16 01 Analog Output Module
  • HIMA X-AI3251 Analog Input Module
  • HIMA X-DO3251 Digital Output Module
  • HIMA X-DI3202 Digital Input Module
  • HIMA X-DI6451 Digital Input Module
  • YASKAWA USAHEM-02-TE53 AC servo motor
  • Yaskawa JZNC-XPP02B Teaching Programmer
  • YASKAWA CACR-SR07BE12M servo drive
  • YASKAWA JAMSC-B2732V Advanced Drive Controller
  • YASKAWA JGSM-06 Controller
  • YASKAWA PCCF-H64MS 64MB Industrial Memory Module
  • YASKAWA CACR-02-TE1K servo driver
  • YASKAWA JAPMC-IQ2303 Controller Module
  • YASKAWA DDSCR-R84H Controller
  • YASKAWA JANCD-XTU01B circuit board
  • YASKAWA JANCD-XIO01 High Performance PC Input/Output (I/O) Board
  • YASKAWA JACP-317800 servo drive
  • XYCOM 120974 - Circuit Board
  • XYCOM 99298-200 - PC Control Card 99207A-001
  • XYCOM 99298-266 - CPU Board
  • XYCOM 99311-001 - Screen Display Ribbon Cable
  • XYCOM 99384-002 - PCB Module 99383A-001
  • XYCOM A05520I01 - Control Module PW22471 MPL400
  • XYCOM A33369 - Dual PMC Carrier Module
  • XYCOM AC2064A1 - VMEbus PCB Board Analog Output
  • XYCOM AC2065A1 - VMEbus PCB Board Analog Output
  • XYCOM CDA XVME - DSP SCSI I/O Module Serial RS232
  • XYCOM 143913-001 - TSKAM Board Rev A
  • XYCOM 1300-000100000 - Operator Interface Node Module
  • XYCOM 140050(R) - Documentation Support Library
  • XYCOM 1811-A00000000 - SXT1811T Monitor 100-120V
  • XYCOM 3112T-1200-256-2K - Operator Interface
  • XYCOM 3115 T - Industrial Computer
  • XYCOM 3406T - Flat Panel Industrial PC
  • XYCOM 3512-03F114003 - Automation Operator Interface
  • XYCOM 3515-A2P214003 - Operators Interface 6.3A
  • XYCOM 3535 - Operation Panel 3535-E3T434003
  • XYCOM 3612 T - LCD Flat Panel Display
  • XYCOM 3715 - Industrial Touchpanel Touchscreen PC
  • XYCOM 4115 T - Light-Duty Flat Panel 2000-512-2K
  • XYCOM 50151 - Automation Display
  • XYCOM 5017-T - Flat Panel Industrial Touch Monitor
  • XYCOM 3308T - 8" Flat Panel Color Touchscreen PC
  • XYCOM 9000-FFP-HU - Industrial Module
  • XYCOM 9440 - Automation HMI 9440-026714001
  • XYCOM 3406 KPT - Automation Control Panel
  • XYCOM 3000-CBL-25VP - Video Cable 25' 7.5M
  • XYCOM CA3-MBPALL-41 - Modbus Plus Module for GP2000
  • XYCOM QPI-MBP-XA1 - Modbus Plus Communication Module
  • XYCOM 3512 T - Automation Model HMI PM-101722C
  • XYCOM PM-102159 - Xycom Automation Monitor
  • XYCOM 3115T - Automation Panel
  • XYCOM PM3510T - Touch Screen HMI
  • XYCOM XA_WIN_2K_MUI - Recovery Media 2 Disks Kit
  • XYCOM XT1502T-CU17 - Viewtronix Flat Panel Touch Display
  • XYCOM XVME-9660 - VMEbus Module 779660
  • XYCOM 8000 KB3 Industrial Keyboard 97788-001
  • XYCOM 8000 KB5 Keyboard Front Panel Repair Evaluation
  • XYCOM 8100 0272A CNC Brown Out Sensor PROM Card
  • XYCOM 81600EA Control Card 82088-004/R
  • XYCOM 81625DA Control Board PC Board
  • XYCOM 81862 003R PCB Circuit Board
  • XYCOM 818662 003 N Pcb Circuit Board
  • XYCOM 81945F Control Card
  • XYCOM 81987 001 D General Purpose I/O 1805 Circuit Board
  • XYCOM 82029BC PCB Circuit Board 82027-001-F
  • XYCOM 82034CA Processor Module Board PC Computer Board
  • XYCOM 83017 002 PCB Circuit Board
  • XYCOM 83034CA Processor Module Board
  • XYCOM 83060C Processor Module Board
  • XYCOM 83060CA Processor Module Board