  • METSO A413310 8-Channel Digital Output Module
    ❤ Add to collection
  • METSO A413310 8-Channel Digital Output Module

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    • ¥12352.00
      ¥15672.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:0.236KG
    • Quantity:
    • (Inventory: 5677)
Description
<span style="font-size: 20px; font-family: arial;">METSO A413310 8-Channel Digital Output Module</span>

METSO A413310: 8-Channel Digital Output Module

The METSO A413310 is a versatile 8-channel digital output module designed for seamless integration into Metso Damatic XD and Valmet DNA automation platforms. It delivers robust 24V DC output signals (0.5A per channel) for driving solenoids, contactors, indicators, and PLC inputs. Outputs are available in solid-state (transistor) or electromechanical relay variants. Each channel provides short-circuit protection, over-temperature shutdown, and individual status indication. The module features 1500V AC channel-to-backplane isolation, wide operating temperature (-20°C to +60°C), and conformal-coated PCB for humidity resistance. With hot-swap capability and removable terminal blocks, the A413310 minimizes downtime. It is ideal for pulp & paper, power, chemical, oil & gas, and water treatment applications requiring reliable binary control.


Platform Compatibility

The A413310 is a standard digital output module for Metso Damatic XD and Valmet DNA distributed control systems. It occupies a single slot in the I/O rack and is fully characterized within Valmet DNA Workbench for plug-and-play configuration. Field-mount IP65 variants are also available for remote installation.

Key Features and Functional Capabilities

  • 8 Independent Digital Outputs: Each channel provides a high-side switching output for 24V DC loads. Output types: transistor (sourcing, 0.5A) or relay (SPST-NO, 2A). Software-selectable sinking version also available.

  • Comprehensive Protection: Short-circuit protection (auto-restart), over-temperature shutdown, and overvoltage clamping per channel. Relay versions include snubber circuits for inductive load suppression.

  • Galvanic Isolation: Channel-to-backplane isolation 1500V AC, channel-to-channel isolation 500V DC. Prevents ground loops and protects controller electronics.

  • Per-Channel Status Indication: Green LED for output ON, red LED for fault (short-circuit, overload, wire break for forced off-state monitoring). Module status LEDs (POWER, RUN, FAULT).

  • Configurable Fail-Safe Mode: Programmable safe state (hold last state, preset value, or force to zero) upon communication loss or module fault.

  • Robust Industrial Design: Conformal-coated PCB meets IPC-CC-830B for resistance to humidity, condensation, and corrosive gases. Operating temperature -20°C to +60°C (standard), -30°C to +70°C (IP65 variant).

  • Hot-Swap Capable: Module can be replaced while backplane is powered without disturbing adjacent I/O, minimizing process downtime.

  • Removable Terminal Blocks: Screw-type or spring-clamp terminals (0.2-2.5 mm²) facilitate wiring and module exchange without disconnecting individual wires.

Technical Specifications

ParameterSpecification
Product TypeDigital Output Module, 8 channels
Part NumberA413310 (variants: A413310-T, A413310-R, A413310-IP65)
Output Channels8, common ground (sourcing) or common positive (sinking) – ordering option
Output Type (Transistor)MOSFET, high-side switch, 24V DC ±20%
Continuous current: 0.5A per channel, 4A total per module
Leakage current:<0.1mA off-state
Voltage drop:<1V at rated current
Protection: short-circuit (auto restart), over-temperature
Output Type (Relay)Electromechanical relay, SPST-NO
Contact rating: 2A @ 30V DC / 250V AC
Mechanical life: 10⁷ operations
Electrical life: 10⁵ operations at rated load
Coil suppression: varistor (bidirectional)
Output Switching TimeTransistor:<50µs on/off
Relay:<10ms operate / <5ms release
Pulse FrequencyTransistor: up to 100Hz (resistive load)
Relay: up to 2Hz
Isolation1500V AC channel-to-backplane (1 min)
500V DC channel-to-channel (continuous)
Field Supply Voltage24V DC ±20% (external or backplane powered)
Maximum current: 4A (fused or electronic protection)
DiagnosticsPer-channel LED: green (output on), red (fault). Module LEDs: POWER, RUN, FAULT. Readback of output state (transistor version).
Operating Temperature-20°C to +60°C (standard), -30°C to +70°C (IP65 variant)
Storage Temperature-40°C to +85°C
Relative Humidity5% to 95% non-condensing (IEC 60068-2-30)
Vibration / ShockIEC 60068-2-6 (10-500Hz, 5g) / IEC 60068-2-27 (30g, 11ms)
EMC ImmunityIEC 61000-6-2 (industrial environment), EN 61000-4-2/3/4/5/6
Protection RatingIP20 (rack module), IP65 (field-mount variant with M12 connectors)
Mounting35mm DIN rail (EN 60715) or panel mount (IP65)
ConnectorsRemovable screw terminal blocks, 0.2-2.5 mm² (rack); M12 circular connectors (IP65)
Dimensions (W×H×D)100 × 60 × 30 mm (rack) / 150 × 120 × 50 mm (IP65)
WeightApprox. 0.4 kg (rack), 0.9 kg (IP65)
CertificationsCE, UL 61010-1, CSA C22.2, ATEX/IECEx (optional)
MTBF>1,200,000 hours @40°C (Telcordia SR-332, transistor version)


Industrial Applications

The METSO A413310 digital output module is deployed across a wide range of industries for reliable on/off control of final control elements:

  • Pulp & Paper: Actuation of solenoid valves for digester blowdown, paper machine felt conditioning, and broke conveyor diverters. Control of motor starters for pumps and agitators.

  • Power Generation: Operation of soot blowers, burner management system pilot valves, and auxiliary equipment start/stop.

  • Chemical & Petrochemical: Switching of feed cutoff valves, alarm annunciators, and emergency shutdown system actuators.

  • Oil & Gas: Wellhead wing valve control, pipeline emergency shutoff valves, and compressor unloaders.

  • Water & Wastewater: Pump start/stop, filter backwash sequence valves, and chemical dosing pump control.

  • Mining & Minerals: Conveyor belt trip controls, crusher lubrication system solenoids, and flotation cell air valves.

Operational Benefits and Lifecycle Value

  • Reduced Engineering and Commissioning Time: Predefined I/O mapping and faceplate graphics in Valmet DNA Workbench enable rapid configuration. Output forcing and simulation features simplify loop testing.

  • Lower Spare Parts Inventory: One A413310 module covers eight outputs, reducing the number of unique part numbers required. Field-proven reliability minimizes replacement frequency.

  • Minimized Unplanned Downtime: Per-channel fault diagnostics pinpoint wiring errors, short circuits, and overload conditions. Hot-swap capability allows module replacement in seconds without system shutdown.

  • Enhanced Equipment Protection: Short-circuit and over-temperature protection prevent damage to output drivers and field wiring. Snubber circuits on relay versions extend contact life when driving inductive loads.

  • Long-Term Support: As part of Valmet's installed base commitment, the A413310 is guaranteed to be available and supported for the life of Damatic XD and DNA systems—often exceeding 20 years.


Configuration and Ordering Information

A413310-T – 8-channel digital output module, transistor (sourcing), 24V DC, 0.5A/ch, IP20, DIN rail mount, screw terminals.

A413310-R – 8-channel digital output module, relay (SPST-NO), 2A/ch, IP20, DIN rail mount, screw terminals.

A413310-IP65 – Field-mount version with IP65 enclosure, M12 connectors, -30°C to +70°C operating range, ATEX/IECEx certified. Available with transistor or relay outputs.

A413310-S – Special version with sinking (PNP to NPN) transistor outputs.


Conclusion

The METSO A413310 8-channel digital output module delivers the robust performance, diagnostic intelligence, and installation flexibility required for modern industrial automation. Its ability to drive a wide variety of field devices—from solenoids to motor contactors—makes it an indispensable component in Valmet DNA and Damatic XD systems. The combination of high-density packaging, comprehensive protection, and hot-swap readiness directly contributes to lower total cost of ownership, faster project execution, and sustained operational uptime. For engineers and maintenance professionals, the A413310 represents the benchmark for digital output modules in the process industries, embodying Metso/Valmet's commitment to quality, reliability, and long-term customer partnership.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications
  • Bonfiglioli 300 series reducer installation, maintenance, and troubleshooting guide
  • Selection and integration guide for Bonfiglioli R3 series planetary gearboxes in primary crushing equipment
  • Bonfiglioli C-series ATEX gearbox selection and explosion-proof application guide
  • Bonfiglioli Vectron EM-ENC-05 Full Function Expansion Module Integration Guide
  • Bonfiglioli Vectron EM-ENC-04 Multi functional Expansion Module Complete Configuration Guide
  • Bonfiglioli Vectron EM-ENC-03 Second Encoder Interface and System Bus Expansion Guide
  • Bonfiglioli Vectron EM-ENC-02 Expansion Module Integration and Encoder Interface Guide
  • Bonfiglioli Vectron CM-CAN CANopen Communication Configuration and DS402 Control Guide
  • Bonfiglioli Vectron EM-SYS System Bus Networking and Virtual Link Configuration Guide
  • Bonfiglioli Vectron CM-PDP Profibus DP Configuration and Debugging Guide
  • Bonfiglioli Vectron CM-232/485 Modbus Communication Configuration Guide
  • Bonfiglioli BMS series servo reduction motor selection and integration guide
  • Bonfiglioli ACTION 210/410 Inverter Debugging and Fault Diagnosis Complete Guide
  • Honeywell Enhanced Micro TDC 3000X System Redundancy Architecture and Maintenance Guide
  • Selection and Configuration of Bonfiglioli Active Series Inverter
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli HDP/HDO Series Heavy duty Gearboxes
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli 300/300M Series Gearboxes
  • Bonfiglioli 300M planetary gearbox selection and thermal verification guide
  • Bonfiglioli 3/H series heavy-duty gearbox selection and verification guide
  • Bonfiglioli KRG/KCG/KSD Hydraulic Coupling Selection and Integration Guide
  • Bonfiglioli BTD/BCR Servo Motor System Integration and Interface Configuration Guide
  • Bonfiglioli BTD/BCR Synchronous Servo Motor Selection and Interface Configuration Guide
  • Bonfiglioli VF-W series ATEX explosion-proof reducer selection guide
  • Bonfiglioli EM-ENC-03 Expansion Module Configuration and System Bus Integration Guide
  • Bonfiglioli EVOX CP Explosion proof Reducer: Quick Guide for Installation and Maintenance
  • Bonfiglioli C/A/F/S Reducer ATEX Installation and Maintenance Practice Guide
  • Bonfiglioli BXN/MXN Motor Installation and Brake Maintenance Complete Guide
  • Bonfiglioli VF-W IE2/IE3 Worm Gear Reducer: Energy Efficiency Selection and Application Practice Guide
  • Bonfiglioli VF-W Explosion proof Worm Gear Reducer: ATEX Selection and Installation Complete Guide
  • Selection and Calculation of Bonfiglioli RAN Right Angle Gearbox
  • Bonfiglioli Industrial Transmission System Selection Guide
  • Bonfiglioli EVOX Gearmotor Selection and Configuration Guide
  • Bonfiglioli CAFS Reducer Selection and Application Guide
  • Bonfiglioli C-A-F gearbox selection and maintenance
  • Bonfiglioli C Series ATEX Explosion proof Reducer Selection
  • Bonfiglioli BN-BE-BX Series Motor Selection Guide
  • Bonfiglioli BMD Servo Motor Selection and Configuration Guide
  • Selection of Bonfiglioli A-series servo reducer
  • Bonfiglioli AS Series Reducer Installation and Maintenance Guide
  • Bonfiglioli Active 401/201 Inverter Selection and Application Guide
  • Bonfiglioli EM-IO-04 Expansion Module Configuration Guide
  • Bonfiglioli EM-ENC-02 Expansion Module Engineering Configuration Guide
  • Bonfiglioli A-series gearbox selection and maintenance
  • Bonfiglioli Transmission and Automation Product Selection Reference
  • Bonfiglioli RAN series bevel gearbox selection and maintenance guide
  • Bonfiglioli ACTION 401/201 Inverter Engineering Integration Guide
  • Alcatel Lucent Stellar AP1301 Deployment and Performance Optimization
  • Alcatel Lucent ALE Wireless Handheld System Selection and Deployment Guide
  • In depth analysis of Alcatel Lucent MDR-8000 microwave system engineering technology
  • Alcatel 1660SM Multi Service Node Operations and Troubleshooting