Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • METSO A413110 8-Channel Analog Input Module
    ❤ Add to collection
  • METSO A413110 8-Channel Analog Input Module

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    • ¥18634.00
      ¥18856.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:0.436KG
    • Quantity:
    • (Inventory: 4775)
Description
<span style="font-size: 20px; font-family: arial;">METSO A413110 8-Channel Analog Input Module</span>

METSO A413110: 8-Channel Analog Input Module

The METSO A413110 is a versatile 8-channel analog input module designed for seamless integration into Metso Damatic XD and Valmet DNA automation platforms. It supports universal analog inputs including current (4-20mA, 0-20mA), voltage (0-10V, ±10V), resistance temperature detectors (RTD: PT100, PT1000), and thermocouples (J, K, T, E). Each channel is individually configurable and features 16-bit A/D conversion, high common-mode rejection, and 1500V AC isolation. The module provides per-channel LED status indication, wire break detection, and comprehensive self-diagnostics. Housed in a compact DIN-rail mountable enclosure with conformal-coated PCB, the A413110 operates from -20°C to +60°C and meets CE/UL certifications. It is ideal for pulp & paper, power, chemical, mining, and water/wastewater applications requiring reliable and precise analog measurement.


Platform Compatibility

The A413110 is a universal analog input module for Metso Damatic XD and Valmet DNA distributed control systems. It mounts in standard I/O racks or can be used as a standalone field module with optional IP65 enclosure. Full characterization within Valmet DNA Workbench ensures plug-and-play configuration.

Key Features and Functional Capabilities

  • 8 Universally Configurable Analog Inputs: Each channel independently accepts current, voltage, RTD, or thermocouple signals without external signal conditioners. Software-selectable ranges cover all common process signals.

  • High-Accuracy 16-Bit A/D Conversion: Integrated delta-sigma ADC delivers ±0.1% of full-scale accuracy (typical) with 16-bit resolution. Sampling rate 10 Hz to 100 Hz per channel, user-selectable.

  • Galvanic Isolation: Channel-to-backplane isolation 1500V AC, channel-to-channel isolation 500V DC. Prevents ground loops and protects sensitive controller electronics.

  • Advanced Diagnostics: Per-channel green/red LED indicates input status and wire-break detection (for 4-20mA loops). Module-level status LEDs for power, communication, and fault. Continuous self-monitoring with reporting to the host system.

  • Sensor Compatibility: Supports 2-, 3-, and 4-wire RTD connections with automatic lead resistance compensation. Cold-junction compensation for thermocouples (internal or external CJC).

  • Robust Industrial Design: Conformal-coated PCB meets IPC-CC-830B for humidity and chemical resistance. Operating temperature -20°C to +60°C, storage -40°C to +85°C. Vibration and shock tested to IEC 60068-2-6/27.

  • Hot-Swap Capable (Rack Version): Module can be replaced while backplane is powered without disturbing adjacent I/O modules.

Technical Specifications

ParameterSpecification
Product TypeAnalog Input Module, 8 channels
Part NumberA413110 (variants: A413110-01, A413110-IP65)
Input Channels8 differential or single-ended (software selectable)
Supported Signal TypesCurrent: 0-20mA, 4-20mA (input impedance 50Ω)
                       Voltage: 0-5V, 0-10V, ±5V, ±10V (input impedance >1MΩ)
                       RTD: PT100, PT500, PT1000, Ni100 (2/3/4-wire)
                       Thermocouple: Types J, K, T, E, N, R, S, B (CJC internal/external)
Resolution16-bit (delta-sigma ADC)
Accuracy±0.1% of full scale (typical) @25°C; ±0.3% over temperature range
Sampling Rate10 Hz / 50 Hz / 100 Hz per channel (software selectable)
Isolation1500V AC channel-to-backplane (1 min), 500V DC channel-to-channel
CMRR / NMRR>120 dB @ 50/60 Hz / >60 dB @ 50/60 Hz
Field Supply Voltage24V DC ±20% (external or backplane powered), max 200mA
DiagnosticsPer-channel: wire break detection (4-20mA), over-range/under-range. Module: POWER, RUN, FAULT LEDs; health status via backplane
Operating Temperature-20°C to +60°C (standard), -30°C to +70°C (IP65 variant)
Storage Temperature-40°C to +85°C
Relative Humidity5% to 95% non-condensing (IEC 60068-2-30)
Vibration / ShockIEC 60068-2-6 (10-500Hz, 5g) / IEC 60068-2-27 (30g, 11ms)
EMC ImmunityIEC 61000-6-2 (industrial environment), EN 61000-4-2/3/4/5/6
Protection RatingIP20 (rack module), IP65 (field-mount variant with M12 connectors)
Mounting35mm DIN rail (EN 60715) or panel mount (IP65)
ConnectorsRemovable screw terminal blocks, 0.2-2.5 mm² (rack); M12 circular connectors (IP65)
Dimensions (W×H×D)100 × 60 × 30 mm (rack) / 150 × 120 × 50 mm (IP65)
WeightApprox. 0.4 kg (rack), 0.9 kg (IP65)
CertificationsCE, UL 61010-1, CSA C22.2, ATEX/IECEx (optional)
MTBF>1,000,000 hours @40°C (Telcordia SR-332)


Industrial Applications

The METSO A413110 analog input module is deployed in a wide range of process industries where accurate and reliable measurement is essential:

  • Pulp & Paper: Stock consistency, headbox pressure, drying cylinder temperature, and bleaching chemical flow monitoring.

  • Power Generation: Boiler drum level, main steam pressure, flue gas temperature, and cooling water flow measurement.

  • Chemical & Petrochemical: Reactor temperature and pressure, distillation column differential pressure, tank level, and catalyst feed rate.

  • Mining & Minerals: Slurry density, thickener underflow pressure, flotation cell air flow, and conveyor belt scale signals.

  • Water & Wastewater: Pump discharge pressure, reservoir level, filter differential pressure, and chemical dosing flow.

  • Pharmaceutical & Biotech: Sterilizer temperature profiles, fermentation vessel pH and dissolved oxygen (via 4-20mA converters).


Operational Benefits and Lifecycle Value

  • Reduced Engineering Effort: Universal input type per channel eliminates need for multiple dedicated modules. Configuration via Valmet DNA Workbench is intuitive and reusable.

  • Lower Spare Parts Inventory: One A413110 replaces dozens of signal-specific cards, simplifying stock holding and reducing costs.

  • Minimized Downtime: Per-channel wire break detection and LED status pinpoint faulty loops instantly. Hot-swap capability allows replacement under power.

  • Enhanced Measurement Integrity: High accuracy and isolation ensure trustworthy data for control and reporting, directly impacting product quality and energy efficiency.

  • Long-Term Support: As part of Valmet's Industrial Internet and installed base commitment, the A413110 is guaranteed to be available and supported for the life of Damatic XD and DNA systems—often exceeding 20 years.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ENOTEC OXITEC 5000 Oxygen Analyzer Maintenance Guide
  • KUKA KR C4 extended assembly and debugging
  • KUKA KR C4 compact assembly and debugging
  • KUKA Sunrise Cabinet Med Medical Collaborative Robot Special Control Cabinet
  • KUKA Sunrise Cabinet Next Generation Small Control Cabinet
  • KUKA KR C4 Smallsize-2 family's smallest control cabinet
  • KUKA KR C4 Midsize Fault Diagnosis
  • KUKA KR C4 extended is a high-power multi axis control cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Control Cabinet
  • Troubleshooting and Maintenance of KUKA KR C4 Compact Control Cabinet
  • KUKA KR15 DELTA-2 V2 Robot Installation and Debugging
  • KUKA TITAN-2 Ultra Assembly and Maintenance Guide
  • KUKA KR SCARA-2 CS Assembly, Debugging, and Operation Guide
  • Troubleshooting KUKA SCARA X
  • Troubleshooting of KUKA KR FORTEC-2 ultra
  • Troubleshooting of KUKA KR FORTEC-2
  • Troubleshooting KUKA KR 1000 Titan
  • Troubleshooting of KUKA KR 600 FORTEC
  • KUKA KR 500 MT FORTEC Maintenance and Inspection
  • KUKA KR 360 FORTEC Inspection and Maintenance Guide
  • Troubleshooting KUKA Sunrise Cabinet Med
  • KUKA KR SCARA HO Assembly and Maintenance
  • KUKA QUANTEC-2 PA maintenance troubleshooting
  • KUKA QUANTEC-2 K/P Maintenance Troubleshooting Guide
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications
  • Bonfiglioli 300 series reducer installation, maintenance, and troubleshooting guide
  • Selection and integration guide for Bonfiglioli R3 series planetary gearboxes in primary crushing equipment
  • Bonfiglioli C-series ATEX gearbox selection and explosion-proof application guide
  • Bonfiglioli Vectron EM-ENC-05 Full Function Expansion Module Integration Guide
  • Bonfiglioli Vectron EM-ENC-04 Multi functional Expansion Module Complete Configuration Guide
  • Bonfiglioli Vectron EM-ENC-03 Second Encoder Interface and System Bus Expansion Guide
  • Bonfiglioli Vectron EM-ENC-02 Expansion Module Integration and Encoder Interface Guide
  • Bonfiglioli Vectron CM-CAN CANopen Communication Configuration and DS402 Control Guide
  • Bonfiglioli Vectron EM-SYS System Bus Networking and Virtual Link Configuration Guide
  • Bonfiglioli Vectron CM-PDP Profibus DP Configuration and Debugging Guide
  • Bonfiglioli Vectron CM-232/485 Modbus Communication Configuration Guide
  • Bonfiglioli BMS series servo reduction motor selection and integration guide
  • Bonfiglioli ACTION 210/410 Inverter Debugging and Fault Diagnosis Complete Guide
  • Honeywell Enhanced Micro TDC 3000X System Redundancy Architecture and Maintenance Guide
  • Selection and Configuration of Bonfiglioli Active Series Inverter
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli HDP/HDO Series Heavy duty Gearboxes
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli 300/300M Series Gearboxes
  • Bonfiglioli 300M planetary gearbox selection and thermal verification guide
  • Bonfiglioli 3/H series heavy-duty gearbox selection and verification guide
  • Bonfiglioli KRG/KCG/KSD Hydraulic Coupling Selection and Integration Guide
  • Bonfiglioli BTD/BCR Servo Motor System Integration and Interface Configuration Guide
  • Bonfiglioli BTD/BCR Synchronous Servo Motor Selection and Interface Configuration Guide
  • Bonfiglioli VF-W series ATEX explosion-proof reducer selection guide
  • Bonfiglioli EM-ENC-03 Expansion Module Configuration and System Bus Integration Guide
  • Bonfiglioli EVOX CP Explosion proof Reducer: Quick Guide for Installation and Maintenance
  • Bonfiglioli C/A/F/S Reducer ATEX Installation and Maintenance Practice Guide
  • Bonfiglioli BXN/MXN Motor Installation and Brake Maintenance Complete Guide
  • Bonfiglioli VF-W IE2/IE3 Worm Gear Reducer: Energy Efficiency Selection and Application Practice Guide
  • Bonfiglioli VF-W Explosion proof Worm Gear Reducer: ATEX Selection and Installation Complete Guide
  • Selection and Calculation of Bonfiglioli RAN Right Angle Gearbox
  • Bonfiglioli Industrial Transmission System Selection Guide
  • Bonfiglioli EVOX Gearmotor Selection and Configuration Guide
  • Bonfiglioli CAFS Reducer Selection and Application Guide
  • Bonfiglioli C-A-F gearbox selection and maintenance
  • Bonfiglioli C Series ATEX Explosion proof Reducer Selection
  • Bonfiglioli BN-BE-BX Series Motor Selection Guide
  • Bonfiglioli BMD Servo Motor Selection and Configuration Guide
  • Selection of Bonfiglioli A-series servo reducer
  • Bonfiglioli AS Series Reducer Installation and Maintenance Guide
  • Bonfiglioli Active 401/201 Inverter Selection and Application Guide
  • Bonfiglioli EM-IO-04 Expansion Module Configuration Guide
  • Bonfiglioli EM-ENC-02 Expansion Module Engineering Configuration Guide
  • Bonfiglioli A-series gearbox selection and maintenance
  • Bonfiglioli Transmission and Automation Product Selection Reference
  • Bonfiglioli RAN series bevel gearbox selection and maintenance guide
  • Bonfiglioli ACTION 401/201 Inverter Engineering Integration Guide
  • Alcatel Lucent Stellar AP1301 Deployment and Performance Optimization
  • Alcatel Lucent ALE Wireless Handheld System Selection and Deployment Guide
  • In depth analysis of Alcatel Lucent MDR-8000 microwave system engineering technology
  • Alcatel 1660SM Multi Service Node Operations and Troubleshooting