Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

AB 1761 - NET - Ethernet Interface for ENI MicroLogix

F: | Au:FAN | DA:2025-04-18 | 716 Br: | 🔊 点击朗读正文 ❚❚ ▶ | Share:

AB 1761 - NET - Ethernet Interface for ENI MicroLogix

Product Overview: The 1761 - NET - ENI and 1761 - NET - ENIW provide EtherNet/IP connectivity for MicroLogix, CompactLogix, and other controllers, supporting communication with a wide range of devices, uploading and downloading programs, and sending e-mail. 1761 - NET - ENI and 1761 - NET - ENIW also have a web server function that allows access to device information via a web page. The ENIW is available in different series, each with upgraded hardware and features, such as 10/100 - Base - T Ethernet ports in the C series and Ethernet configuration and email authentication in the D series.


Installation and wiring: The products comply with the relevant European directives, and should be installed with safety in mind, with specific requirements for use in hazardous areas. DIN rail or panel mounting is possible, vertical mounting and ventilation space are required. The external power supply is subject to availability and the earth connection must be correct. The Ethernet port uses an RJ45 10/100 - Base - T connector, depending on the cable type when connecting to different devices; the RS-232 port is used for connecting to DF1-compatible devices and has specific cable and connector requirements.


Operation and Configuration: The device communicates via the EtherNet/IP protocol and supports 6 Ethernet connections, different connections for different purposes. Configuration can be performed using the ENI/ENIW configuration tool, controller message commands, BOOTP or DHCP servers, with a wide range of parameters including IP address, subnet mask, gateway, etc. The mail function can also be configured to set up the SMTP (SMTP) function. The mail function can also be configured to send mail by setting parameters such as SMTP server, mail address, etc. The ENIW's web server function can be accessed via a web page, supporting page customisation, data display and interaction.


Application Example: Taking the connection of CompactLogix controller to Ethernet as an example, it introduces in detail the system setup, ENI configuration, programme download and related precautions. It includes the configuration methods of different series of ENIs and the steps to configure the driver in RSLinx software to achieve inter-device communication. Sample MSG ladder programs for SLC 5/05 and ControlLogix controllers are also given.


Troubleshooting and Performance: The different states of the LEDs can be used to determine the operation of the device and the types of faults, such as problems with power, network connections, data transmission, etc. ENI/ENIW generates an error code to indicate the cause of the fault, and care should be taken to maintain the cable connections to avoid problems with network communications. The product has some limitations on data throughput, number of connections and packet size, such as different size limitations for data transmission through ENI/ENIW for different controllers.


Communication capability: Supports EtherNet/IP protocol, providing network connection for MicroLogix, CompactLogix and other controllers to exchange data, upload/download programs and communicate between devices. Supports SMTP mail service, which allows the controller to send mails to any email address in the network for reporting alarms, status and other information. 6 concurrent TCP/IP connections, 2 for incoming messages, 2 for outgoing messages, and 2 for flexible allocation. Each TCP/IP connection can support 4 CIP connections and 5 unconnected sends at the same time, which can meet the complex communication requirements between multiple devices.


Configuration Flexibility: Supports a variety of configuration methods, such as through the ENI/ENIW configuration utility via the RS-232 port or Ethernet, or using controller message commands or BOOTP, DHCP server to configure IP address and other parameters. The configuration parameters are rich, including IP address, subnet mask, gateway, communication rate, mail server settings, security mask, etc., which can be set flexibly according to different network environments and application requirements. Different series of products are constantly upgraded in configuration functions, such as the D series, which adds Ethernet configuration function and email user authentication function, which can be configured and managed more conveniently through the web.


Network Adaptability: Ethernet ports support 10/100-Base-T standard, and speed and duplex modes can be negotiated automatically (C series and above) or manually enforced (D series) to adapt to different network environments. Supports a variety of network topologies, connecting directly to Ethernet switches and communicating over standard 8-core twisted-pair direct-connect cables, or connecting to other network media such as optical fibre and coaxial cables with the aid of media converters. Compatible with a wide range of devices, including MicroLogix, SLC, PLC-5, CompactLogix, FlexLogix and ControlLogix controllers, as well as other devices that support the DF1 full-duplex protocol and personal computers using RSLinx software.


Security features: Configuration Security Mask feature enhances the security of device configurations by restricting which computers can configure an ENI or ENIW over Ethernet based on their IP address. Supports SMTP mail authentication (D-Series), which secures mail delivery by setting a username and password to prevent unauthorised mail delivery. Complies with relevant safety standards, such as UL 1604, C - UL C22.2 No. 213 and other certifications for safe use in industrial environments.


Data Processing and Presentation: ENIW's powerful web server can display device data, including strings, integers and floating point data, on a web page that can be dynamically updated. It supports user-defined web links and page titles, making it easy for users to personalise their settings according to their actual needs. Data can be password-protected to prevent unauthorised modifications, ensuring data security and integrity.

1761-NET-ENI Ethernet Interface Module 1761-NET-ENI PLC Module Sealed ...


  • LTI Motion SC52.0150.0012.0000.0 Servo Drive
  • LTI Motion LSP04-004-048-60-0PR1PY17E0440 Servo Motor
  • LTI KP300-R Drive Interface Operator Display
  • Lust LTI SO84.020.0002.0100.2 Servo Drive
  • LUST LTI CDD34.008.W2.1 CDD3000 Servo Drive
  • LTI MOTION SA54.0550.0033.0000.0 Servo Drive
  • LTI Drives MS100 0927.0017 Mounting Kit
  • LTi DRiVES LSP06-015-320-30-00H1MY170 Servo Motor
  • LTI MC6412 C1 D3 S12 Servo Drive
  • LUST LTi SO82.004.0030.0000.2 Servo Drive
  • LTi Drives LSP06-015-320-30-00H1MY170 Servomotor
  • LUST LTi CDE34.003 C2.0 Servo Drive
  • LUST LTi LSH-127-1-30-560 T1 Servo Motor
  • LTI MOOG CDE54.044 Pitchmaster Servo Drive
  • LTI Lock Technology 1237 Flip Socket Set
  • LTi LSP08-028-560-55-00H1MY1M0 Servomotor
  • Lust LTi CDE34.010.D2.4 Position Controller 10A
  • Lust LTi CDE34.010.D2.4 Positioning Controller 10A
  • LTi Drives FLPF-142-3-12-560/T4 Servomotor
  • LUST LTI Motion CDD54.045 W2.1 Servo Drive
  • LUST LTI CDD34.006.W2.2.PC1 Servo Drive
  • LTI KP200-XL Operator Panel Keypad 4 Key
  • Lust LTI CDE32.008 W2.2.BR Positioning Controller
  • LTI Servo One SO82.004.0030.0000.2 Drive Amplifier
  • LTI MOTION SC54.0550.0012.0000.0 Servo Drive
  • LTI LSN-097-0510-30-560 Servo Motor
  • LTi Drives 0920.0034.14 Product DVD
  • LTI SO82.004.0030.0000.2 Servo Drive
  • MOOG LTI CDE54.044 Pitchmaster Frequency Converter
  • LUST LTI CDE34.017 W3.0 Servo Drive
  • LUST LTi Drives CDS44.072 LC1.1 Servo Drive
  • LUST LTi DC1-3.0006.1000.0 Servo Drive
  • LTi LSMM13-100-4N-001 Servo Motor
  • LTI MOOG CDE54.044 Pitchmaster Servo Drive
  • LUST LTi Drives NFE12.3 Line Filter
  • LTI MOTION SC34.0100.1011.0000.0 Drive
  • LUST LTi LSH-074-2-30-560/T1 B S4 G6.1M Servomotor
  • LUST LTI CDE34.044W2.3 Servo Drive
  • LUST LTi LST-127-5-15-560/T1 S4 G12.1S Servomotor
  • Lust LTi MOTION CDE34.044 W2.4 H13 Servo Drive
  • LTI Servo One SO82.004.0030.0000.2 Drive Amplifier
  • Lust LTI CDE34.006 W2.4 V4.10-02 Servo Controller
  • LTI Drives Stromag FLP 20/0014-60 BA 1 Servomotor
  • Lust LTI CDE34.024.Wx.x.PC1 Servo Controller
  • LTI Drives FLP13-0395-30-AC2 9.5 kW Servo Motor
  • LTI CDB32.004-C2.0SH Servo Drive
  • LTi LSH-074-2-30-320/T1 1R Servo Motor
  • LTi DRiVES LSP08-028-320-30-BPH2MY17E0803 Servo Motor
  • LUST LTI SO24.007.0020.0000.1 Servo Controller
  • LTI CDE34.017.W3.0 Frequency Inverter
  • LUST LTi DRIVES LSH-097-0960-30-560/T1 Servomotor
  • LTi DRiVES LSP10-056-560-50-00H1MY 1M0 Servomotor
  • LTi DRiVES LSP08-028-320-55-00H1MY 170 Servomotor
  • LTI MC6432 C1 D3 S12 G20 Servo Drive
  • Keba LTi CDE32.008 C3.0 Frequency Inverter
  • Lust LTI CDE32.004 C2.4 V4.10-02 Servo Controller
  • LTI SO CM-P.0122.2015.1 Servo Drive
  • LUST LTi LST-127-2-30-560/T1 Servomotor
  • LTI VF1402S Drive
  • LUST LTi LSH-074-3-45-560/T1 Servomotor
  • LUST LTi CDB32.004 C2.4.SH Servo Drive
  • LTI SO82.004.0030.0000.2 Servo Drive
  • LTi Drives CDD34.008 W2.1 BR Servo Driver
  • Lust LTI CDE32.004 C2.4 Servo Controller
  • LTi Drives DSM4-14.2-21R83-200 Servo Motor
  • LTI CDB32.004 C2.4 SH V4.00-3 Servo Drive
  • LUST LTi Drives CDA34.017 W1.4 BR B0 Servo Drive
  • LTI Drives MS100 0927.0017 Mounting Set
  • LTi REENERGY E230 G360 Frequency Inverter Controller
  • LTI Drives Netzfilter 090.01.540.UR Mains Filter
  • LTI Drives LSP08-035-320-30-B0R1PY170 Servo Motor
  • LUST LTi Drives CDS44.072LC1.2 Servo Drive
  • LTI Drives BR-090.03.540.UR.H38 Braking Resistor
  • LTi Drives PM-E40.2DRA054P Pitch Control Inverter
  • LTI Drives LSN-097-0960-30-0560/T1 S4 B Servo Motor
  • LUST LTI SO24.002.0020.0000.1 Servo One Junior
  • LTI MOTION SO84.032.0003.0001.2 Servo Drive
  • LTI 330-0919 IBOP Actuator Cylinder
  • LTI CDE32.004 C2.4 Servo Drive
  • LUST LTI CDD34.017 W3.4PC1 Servo Drive
  • LTI CDA3208 C3.0 HF AC Servo Drive
  • LTi LSP08-028-560-55-00H1MY170 Servo Motor
  • LUST LTI LSH-074-3-30-560/T1 G6.1S Servo Motor
  • LTi CDA32.006 C3.0 H09 Servo Drive
  • LTI SO22.003.0010.0000.0 Servo One Junior Drive
  • LTi DSM4-14.2-21R83-200 Servo Motor
  • LTi Tools 1237 7 Piece Flip Socket Set
  • LTi CDE34.008.W2.4 Servo Drive
  • LUST SO84.008.1020.0070.1 ServoOne Drive
  • LTi LSP06-015-320-30-00H1MY170 Component
  • LTi LSP08-028-320-55-B0H1MY17W Servo Motor
  • LTi SO84.032.0173.0100.1 Servo Drive
  • LTi CDB34.006.W3.0.PC1.H39 Servo Drive
  • LUST BR-200.02.540.UR Brake Resistor
  • LTi REENERGY E230 G360 Frequency Inverter
  • LTi BR-026.03.540-UR Brake Resistor
  • LUST CDA32.006.C3.0.H09 Frequency Inverter
  • LTi SO84.016.1030.0000.0 ServoOne Drive
  • LTi SO24-004-0030-1000-0 Servo Controller
  • LUST CDE34.010.D2.4 Positioning Controller
  • LTi SO22.003.0080.0000.0 Servo Controller
  • LUST CDB32.004.C2.4.SH Servo Drive
  • LTi LSP06-015-320-60-B0H1MY170 Unit
  • LTi Motion PM-D35.1WVA02 Module
  • LTi BR-090.03.540.UR.H38 Brake Resistor
  • LTi FGP 111/002-25 AA Servo Motor
  • LTi ServoOne Junior SO22.006 Servo Controller
  • LUST CDA34.008.W1.4.BR Drive Controller
  • LUST CDA34.017.W3.0 Drive System
  • LUST CDE32.004.C2.4 Drive Controller
  • LTI CDE32.004.C3.0 Servo Drive
  • LUST LSH-097-2-30-560 Servo Motor
  • LUST CDB32.003.C2.4 Servo Controller
  • LUST CDB32.003.C2.3 Servo Controller
  • LUST CDA34.017.W3.0 Drive Controller
  • LTI Tools LT-1400Q Torque Extension
  • LUST SO82.004.0030.0060.2 Servo Drive
  • LUST CDA32.006.C3.0.H09 Drive Controller
  • LTI CDB32.004.C3.7.SH Servo Drive
  • LTI LSH-127-3-30-560 Servo Motor
  • LUST CDA34.017.C2 Servo Drive
  • LTI CM-DPV1 3.0 V2.25-00 Module
  • LTI CDE34.005 W2.4 Servo Drive Controller
  • LUST LR32.8 0925.0018 Line Choke
  • LUST LTi CM-DPV1 3.0 Communication Module
  • LUST LTI Drives CCD34.024.W2.1.BR Servo Drive
  • Lust LTi Drives CDE32.008.W2.2.BR Positioning Controller
  • LTi DRiVES LSH-050-3-45-320/T1 Servo Motor