Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

American Pulp and Paper Technology Association test standards

F: | Au:佚名 | DA:2024-01-15 | 838 Br: | 🔊 点击朗读正文 ❚❚ ▶ | Share:

The Paper and Pulp Industry Technical Association (TAPPI) is the leading technical association for the global paper, pulp and carton processing industries. Since its founding in 1915, TAPPI has grown to become the world's largest professional organization serving the paper, pulp and carton processing industry.

TAPPI Standard Test methods are test procedures and related practices used in the measurement, evaluation and description of pulp, paper, corrugated boxes and other paper products, including raw materials used in their production, such as pulp wood chips. The industry association standard by the United States, Canada, Europe, Australia, Japan and other pulp and paper factories around the world for nearly a hundred years of discussion, demonstration, revision, and continuous professional update, has become a globally recognized pulp and paper industry international standards.

Typically, the TAPPI test methodology is updated twice a year after a meeting of the Standards Advisory Review Group (SARG). The SARG will finally decide whether to approve the new or modified method.

The following section is the modified or increased TAPPI test method approved in September 2005: Inner bonding strength (Z-stretchability) of T541 om-05 paperboard.

This method is used to describe the measurement of the internal fiber strength (Z-tensile strength) of cardboard. A sample of 6.45 square centimeters of cardboard was tested using a specific tool. First, both sides of the test sample are coated and pressure sensitive tape is used on both sides of the test sample. Then the sample is placed between two pressure plates, and uniform pressure is applied to the entire sample surface, so that uniform pressure appears in the vertical direction of the entire test surface, which affects the separation.

This method is suitable for testing cardboard and paper whose internal fiber bonding strength (adhesive strength) is weaker than that of tape. The press plate is made of materials that will affect the bonding strength between the press plate and the tape. When the tape fails or the adhesive is transferred to the sample, the test value will be high. The tape you choose also affects the test results. The adhesive strength of the tape is critical to the repeatability of the test results. New factory tape can be used to test the consistency of adhesive strength. The bonding strength can be tested by stripping with a test disc or by testing a reference sample of stable quality.

T 556 om-05- Bending strength of paper and paperboard (Lorentzen and Wettre test method)

The method is to use a vertical fixture on a mN 38 mm wide sample to determine its bending strength with a deflection of 15° or 7.5°. Test the bending strength of paper and paperboard when passing through the machine longitudinally and laterally. The standard bending Angle is 15° ± 0.1°. A deflection of 7.5° ± 0.1° can be used for samples that are cracked or unsuitable for bending angles of 15°.

T 560 om-05 CIE Paper and board whiteness and color test (d/0 geometry, C/2 Luminescence/observation)

This method is used to measure white or near-white samples with or without the CIE whiteness and color index (1) of a visible brightening agent. The whiteness of paper is different from the brightness of paper because the entire visual spectrum is included in the whiteness measurement, while the brightness test only includes the blue part of the spectrum.

T 560 om-05-CIE Paper and board whiteness and color test (45/0 geometry, C/2 Luminescence/Observation)

The following modifications and additions to TAPPI test methods were approved on March 23, 2005:

T 411 om-05 Thickness of paper, board and multilayer board

The method is used to measure the thickness of a single sheet of paper, cardboard and multiple layers of cardboard, including the thickness of each layer in the multiple layers of cardboard. "Multilayer board" includes corrugated board and fiber board.

Because the transverse passage length of the selected sample is longer than the actual use when performing this test, the test result will have a certain deviation in this direction.

Since a relatively high pressure of 50kPa (7.3psi) was used in this test, it may not be suitable for materials such as paper towels or other soft or low density materials, which are prone to cracking (low thickness) at pressure of 50kPa.

TAPPI T 551 Thickness of paper and board (Soft disk test method)

The method is to measure the effective thickness of paper and paperboard products by using a soft rubber pressure disc. The value obtained by this method is smaller than that measured by TAPPI T 411.

T 480 om-05 Gloss of paper and paperboard

The method is to measure the gloss of the paper at 75° conditions (with the horizontal plane of the paper as a horizontal line, 15° position). Although this method is mainly for coated paper, it is also suitable for testing uncoated paper.

This method is suitable for low gloss and high gloss paper. TAPPI T 653 - "Test paper and board gloss at 20°" gives the best results for very high gloss papers such as cast coating, gloss oil, heavily coated paper or wax and ink films with high gloss. The T 480 has been shown to be suitable for gloss testing on most papers or paperboards with ink film. The color and reflection coefficient of the ink film can be ignored. For example, when white and black surfaces are tested equally, the gloss value of the surface of the white material will be higher than that of the black material.

  • National Instruments NI 9264 Output Module
  • National Instruments IC-3173 Controller
  • National Instruments NI 9234 Vibration Module
  • National Instruments SMB-2163 DIO Accessory
  • National Instruments PXIe-1062Q DSA System
  • National Instruments USB-6289 DAQ Device
  • National Instruments NI 9233 Vibration Module
  • National Instruments PXIe-5840 VST
  • National Instruments PXI-1033 and PXI-6132 System
  • National Instruments GPIB-USB-HS+ Controller
  • National Instruments NI 9231 Sound and Vibration Module
  • National Instruments cRIO-9074 CompactRIO Controller
  • National Instruments 782536-01 DAQ Module
  • National Instruments 779781-01 DAQ Module
  • National Instruments PXIe-8388 MXI Express Controller
  • National Instruments SCXI-1520 Strain Bridge Module
  • National Instruments PCIe-6320 Multifunction DAQ Card
  • National Instruments NI 9234 Sound and Vibration Module
  • National Instruments USB-4431 Sound and Vibration Device
  • National Instruments NI 9227 Current Input Module
  • National Instruments PXI-1033 PXI Chassis
  • National Instruments NI 9213 Thermocouple Module
  • National Instruments PXI-1042 PXI Chassis
  • National Instruments PXI-6229 DAQ Card
  • National Instruments cRIO-9075 Controller
  • National Instruments PCI-6033E DAQ Card
  • National Instruments PCIe-6363 DAQ Card
  • National Instruments cDAQ-9174 Chassis
  • National Instruments PXIe-8880 PXI Controller
  • National Instruments NI 9242 Analog Input Module
  • National Instruments USB-6221 BNC DAQ Device
  • National Instruments NI 9220 Analog Input Module
  • National Instruments cRIO-9068 CompactRIO Controller
  • National Instruments PXI-4130 Source Measure Unit
  • National Instruments USB-6251 Multifunction DAQ Device
  • National Instruments PXI-8106 Embedded Controller
  • National Instruments USB-6218 Multifunction DAQ Device
  • National Instruments PCIe-1473R Camera Link Frame Grabber
  • National Instruments PXIe-4341 DSA Module
  • National Instruments PXI-8102 Embedded Controller
  • National Instruments cDAQ-9178 Chassis
  • National Instruments USB-6210 DAQ Device
  • National Instruments USB-6212 DAQ Device
  • National Instruments NI 9485 Relay Output Module
  • National Instruments NI 9208 Current Input Module
  • National Instruments PXIe-4141 SMU
  • National Instruments PCI-6154 DAQ Card
  • National Instruments cRIO-9038 Controller
  • National Instruments PCI-6133 DAQ Card
  • National Instruments LabVIEW RIO Kit 501684G
  • National Instruments PXIe-6396 Embedded Controller
  • National Instruments USB-8502 CAN Interface Device
  • National Instruments NI 9264 Spring Terminal Output Module
  • National Instruments NI 9213 Thermocouple Input Module
  • National Instruments NI-9205 Analog Input Module
  • National Instruments NI 9264 Analog Output Module
  • National Instruments USB-6212 Multifunction I/O Module
  • National Instruments PXI-4071 FlexDMM Multimeter Module
  • National Instruments NI-9208 DSUB Current Input Module
  • National Instruments PXIe-6363 X Series I/O Module
  • National Instruments NI 6587 LVDS Digital I/O Module
  • National Instruments PCI-6225 Data Acquisition Card
  • National Instruments NI-9262 Analog Output Module
  • National Instruments NI 9235 Quarter Bridge Input Module
  • National Instruments PXIe-8301 Remote Control Module
  • National Instruments PXI-4071 FlexDMM Module
  • NI-9234 Sound and Vibration Input 779680-01
  • NI 9229 Isolated Analog Input Module
  • NI cDAQ-9178 USB CompactDAQ Chassis
  • National Instruments NI 9220 143613B-06L Analog Input Module
  • NI 9229 Analog Input Module
  • NI 9246 Analog Input Module
  • NI PXIe-1071 PXI Express Chassis
  • National Instruments 9225 780159-01 Analog Input Module
  • NI cDAQ-9171 USB CompactDAQ Chassis
  • NI PXIe-8840 Embedded PXI Controller
  • Bonfiglioli A202 UH35 FIA 39.6 Right Angle Reducer
  • Bonfiglioli BN 90 LA 4 Gearmotor 1.5kW i=14.1
  • Bonfiglioli BN71A4 Motor with C313PP71 Gearbox
  • Bonfiglioli MP 130 1 4 STD 114A CD Planetary Gear Head
  • Bonfiglioli LC155 1 10 STD Gearbox
  • Bonfiglioli Vectron ACU401-13 FA Inverter
  • Bonfiglioli AEC500-31A Solar Inverter
  • Bonfiglioli BN63B6 Geared Motor VF44P
  • Bonfiglioli Vectron ACT410-23 Inverter
  • Bonfiglioli FR FRIZ 11/90 Clutch
  • Bonfiglioli A/11.90 B3 Clutch Brake
  • Bonfiglioli 50.180.3000 Servo Motor
  • Bonfiglioli NFF 14 112 EE Clutch
  • Bonfiglioli BMD 65 Permanent Magnet Motor
  • Bonfiglioli MP 080 2 20 STD 73A1 CD Planetary Gearbox
  • Bonfiglioli VF/VF30/63 P1 1520 Gearbox
  • Bonfiglioli M3SA4 FD with X F202 H35 10.0 Gearbox
  • Bonfiglioli ACU401-19A Frequency Inverter 5.5kW
  • Lafert B6306P-02276 Servo Motor with Bonfiglioli A102
  • Bonfiglioli ACU401-09FA Frequency Inverter 1.1kW
  • ProMinent Sigma S1CBH12035 with Bonfiglioli BN56B4
  • Bonfiglioli TR 080 2 20 STD Planetary Gearbox
  • Bonfiglioli ACT400-040A Frequency Inverter 15kW
  • Bonfiglioli BE 132 MA 4 Electric Motor 7.5kW
  • Bonfiglioli W86 U30 P100 Gearbox
  • Bonfiglioli MP105 2 25 Planetary Gearbox
  • Bonfiglioli BE160L4 Motor 15 kW
  • BONFIGLIOLI TMP-105 2 25 15 19 40 70 90 Planetary Gearbox
  • Bonfiglioli Vectron ACU401-18 FA Inverter
  • BONFIGLIOLI BE80B4 Motor with A302 UH35 76.5 P80 VA Gearbox
  • Bonfiglioli Vectron VCB400-180 Inverter
  • Bonfiglioli P63B14B3 Motorization Encoder
  • Bonfiglioli Vectron ACT201-13FA Inverter
  • Bonfiglioli F202 H30 P90 Gearbox
  • Bonfiglioli BN71A4 C313 P P71 Gearmotor
  • Bonfiglioli ACT201-11FA Frequency Inverter
  • Bonfiglioli ACU410-21 3 FA Inverter 7.5kW
  • Bonfiglioli RA0 60/00 Gear Reducer i=182
  • Alpha VDS 063-MF1-10-141-BE Planetary Gear 20018280
  • Stöber FDR 71B/10 Gearmotor 0.37kW
  • Stöber DW0-2000-037-4 Gearbox 0.25kW
  • Bonfiglioli M3SA4 FD R with X F252 H35 16.6 Gearbox
  • Bonfiglioli BN90LA4 Adjustable Gear Motor 1.5kW
  • Alpha LP 090-MO1-5-111-000 Planetary Gearbox
  • Bonfiglioli 335 M3 C Planetary Gear Motor
  • Bonfiglioli TR060 2 18 STD 50C CD 14 S1 OR SB KE Gearbox
  • Bonfiglioli MP1GD3036L001 Gearbox
  • Bonfiglioli BN90LA4 Gear Motor 1.5 kW
  • Bonfiglioli A302 UH35 P90 Gearbox
  • Bonfiglioli ACU410-31A5 Inverter
  • BONFIGLIOLI BMD 118 14 4500 400 165 SS TC1 RES2 P1N S1N CUS JB00013358
  • Bonfiglioli A302 UH40 P90 Reducer