Bentley 3500/42 Proximitors ®/ Earthquake monitoring module

来源: | 作者:FAN | 发布时间 :2025-07-07 | 676 次浏览: | 🔊 Click to read aloud ❚❚ | Share:

Bentley 3500/42 Proximitors ®/  Earthquake monitoring module

Product Overview

Core functions

3500/42 Proximitor ®/  The earthquake monitoring module is a four channel monitoring device that can receive input signals from a proximity probe and seismic sensors, and achieve monitoring functions such as radial vibration, thrust position, eccentricity, differential expansion, acceleration, and velocity through configuration. Its core function is to drive alarm output by comparing the current machine vibration value with the preset alarm threshold, and provide machine status data for operation and maintenance personnel.

Key Features

TMR architecture: Supports triple modular redundancy (TMR) configuration, avoids single point of failure through a 2 out of 3 voting mechanism, and ensures system reliability.

Flexible configuration: Customize channel types, alarm thresholds, filtering parameters, etc. through 3500 rack configuration software to adapt to different monitoring scenarios.

Real time diagnosis: Built in self checking function, quickly locate faults through LED indicator lights and event logs.

Safety certification: Compliant with standards such as IEC 61508, suitable for hazardous areas (such as Class I, Division 1/2).

Product Architecture and Working Principle

Hardware Architecture

Input module: support multiple I/O modules, including internal terminal, external terminal, TMR terminal and terminal module with barrier, and adapt to different sensor wiring requirements (such as Proximitor, accelerometer, speed sensor).

Signal processing: Each channel integrates filtering, amplification, and digitization circuits, supporting bandpass, high pass, and low-pass filtering, with a configurable frequency response range (such as radial vibration channels supporting 1 Hz to 4000 Hz).

Communication interface: communicates with other modules through the rack backplane, supports serial protocols such as RS-232/485, and can be connected to the upper computer for data monitoring.

TMR redundancy mechanism

Voting logic: In the TMR configuration, three monitoring modules vote 2 out of 3 for the input signal. If the deviation between the output of one module and that of other modules exceeds the set threshold (such as% Comparison), event logging will be triggered.

Input configuration:

Bus configuration: A single non redundant sensor signal is distributed to three modules through the bus.

Discrete configuration: Three redundant sensors are connected to three modules respectively to improve reliability.

Data output and status monitoring

Proportional value output: Output different parameters based on channel type, such as Direct (peak to peak), 1X/2X amplitude, phase lag, etc. for radial vibration; Gap (gap voltage) and Direct (axial displacement) at the thrust position.

Status identification: Feedback module health status, communication status, and alarm events through LED (OK, TX/RX, BYPASS) and event logs (System Event List, Alarm Event List).


Configuration Guide

Software Configuration Tool

Use 3500 Rack Configuration Software for parameter settings, with core configuration items including:

Channel type: Select radial vibration, thrust position, etc. Different types correspond to different filtering and scaling factors.

Full range: For example, radial vibration Direct can choose 0-10 mil pp (peak to peak), and acceleration can choose 0-20 g pk (peak to peak).

Alarm threshold: Set the Alert/Alarm 1 and Danger/Alarm 2 thresholds for each proportional value, and support lag adjustment (e.g., hysteresis is 1/64 of full scale).

Filter parameters: Set the cut-off frequency of the high/low-pass filter (e.g. acceleration channel supports 3 Hz to 30 kHz).

Example of Key Parameter Configuration

Radial vibration channel:

Select a 3300-8 mm Proximitor sensor and set the Scale Factor to 200 mV/mil.

Set the 1X Amplitude full-scale to 10 mil pp, the Alert threshold to 6 mil pp, the Danger threshold to 8 mil pp, and the delay time to 1 second.

Thrust position channel:

The Zero Position voltage is set to -9.75 Vdc (corresponding to the center value of the gap), the full range is set to 25-0-25 mil, and the direction is set to "Forward Probe" (displacement increases when the rotor moves towards the probe).

Key points of TMR configuration

Three monitoring modules need to be installed adjacent to each other and configured with Comparison Voting (if comparing 1X Amplitude, a deviation of 5% is allowed).

Bussed External Termination Block is used for bus configuration, while three independent sensors and terminal blocks are used for discrete configuration.

I/O modules and wiring

Module type and function

Internal terminal module: directly connected to sensors and recorders, suitable for non hazardous areas, wiring should pay attention to electrostatic protection (such as using anti-static wrist straps).

Internal Barrier Module: Integrated Zener Barrier, suitable for explosion-proof areas (such as Class I, Division 1), to restrict energy flow into hazardous areas.

External terminal module: Connect the sensor with a 25 pin cable and the recorder with a 9-pin cable to simplify the internal wiring of the rack.

Wiring specifications

Proximitor sensor: The power supply (PWR) is connected to -24 Vdc, the signal (SIG) is connected to the channel input, and the shielding layer (SHLD) is grounded.

Seismic sensors (such as Velomitor) require series connection of resistors and capacitors (such as 4 k Ω resistors+10 μ F capacitors) for signal conditioning.

TMR wiring: In discrete configuration, three sensors are connected to independent channels of three modules, and in bus configuration, sensor signals are shared through a Bussed Terminal Block.


Maintenance and testing

Regular verification testing

Testing cycle: It is recommended to conduct it once a year. If the equipment is a critical unit or operates in harsh environments, it can be shortened to once every quarter.

Testing equipment: function generator, multimeter, oscilloscope, Keyphasor Multiplier/Diverder, etc.

Test steps (taking radial vibration channel as an example):

Simulate sensor signals (such as a 100 Hz sine wave with a peak to peak value of 2 V).

Verify the display accuracy of proportional values such as Direct and 1X Amplitude (error ≤ ± 1% of full scale).

Trigger Alert/Arm 1 and Danger/Arm 2 thresholds, confirm that the alarm delay time is consistent with the configuration.

Disconnect the input signal and verify the OK state recovery time (Timed OK Channel Defeat set to 30 seconds).

Scale factor and zero position adjustment

Scale Factor: Used to calibrate the linearity deviation of sensors, such as the default 200 mV/mil for 3300-8 mm Proximitors, which can be adjusted by ± 15%.

Zero Position: For channels such as thrust position and eccentricity, adjust the voltage to make the displayed value zero (such as setting the zero position of thrust position to -9.75 Vdc, corresponding to mechanical zero position).

Recorder output verification

The 4-20 mA output should correspond to the full-scale proportional value. For example, when the full-scale is 10 mil pp, 20 mA corresponds to 10 mil pp, and 4 mA corresponds to 0 mil pp, with an error of ≤± 1%.


Troubleshooting

LED fault diagnosis

OK light off: It may be due to module failure, hardware malfunction, or sensor disconnection. Check the power and wiring, restart the module, or replace spare parts.

BYPASS light on: The channel is bypassed by software or the sensor is faulty. Check the Software Switches configuration and confirm that the sensor is in an OK state.

TX/RX light does not flash: communication failure, check the rack backplane connection and serial port parameters (baud rate, data bits).

Analysis of System Event List

Event 11 (Flash Memory Failure): Flash memory failure, module replacement required immediately.

Event 62 (I/O Module Mismatch): The I/O module type does not match the software configuration. Check the module model and reconfigure it.

Event 493 (Kph Lost): Keyphasor signal loss. Check the Keyphasor sensor and wiring to confirm if the speed is within the valid range (60-60000 cpm).

Common alarm handling

Alert/Arm 1 trigger: If the vibration value exceeds the threshold, check whether the machine is unbalanced, misaligned, or has bearing faults.

Trigger of Danger/Arm 2: Emergency stop condition, immediately stop the machine and troubleshoot equipment faults. If the shaft displacement exceeds the limit, it may cause dynamic and static friction.


Technical specifications and ordering information

key parameter

Input impedance: Proximitor channel 10 k Ω, TMR configuration with bus mode 50 k Ω and discrete mode 150 k Ω.

Frequency response: The radial vibration Direct channel supports 1 Hz-4000 Hz, and the acceleration channel supports 3 Hz-30 kHz.

Environmental conditions: Operating temperature -30 ℃~65 ℃ (non barrier module), storage temperature -40 ℃~85 ℃, humidity ≤ 95% non condensing.

Order Parts

Monitor module: 3500/42-01-00 (discrete internal terminal, no authentication), 3500/42-03-01 (TMR external terminal, CSA authentication).

Spare parts: I/O module (such as 128229-01), terminal block (125808-02 Euro style), cable (129525-0010-01, 10 foot assembly cable).


Safety and Compliance

Explosion proof certification: With barrier module supporting Class I, Division 1 (Groups A-D) and EEx ia IIC, suitable for explosive gas environments.

Static protection: When operating the module, wear an anti-static wrist strap and store it in a conductive bag to prevent static electricity from damaging the circuit board.

Maintenance warning: When hot plugging modules, ensure that the rack is powered off to avoid the risk of short circuit or electric shock caused by live operation.

BENTLY 3500/42M 128229-01 Proximitor Seismic Monitor module Competitive ...

  • Schneider LC1F500P7 Contactor 500A
  • Mitsubishi GT2512-STBA GT2512-STBD HMI
  • Omron NJ1019000 Machine Automation Controller
  • Siemens 6SN1112-1AC01-0AA1 Power Module
  • Eaton AE16KNS0AB Bimetallic Overload Relay
  • ABB 3bse036456r1 Ai825 Analog Input 4 Ch
  • Fuji Electric 7MBR50SB120-50 IGBT Module
  • Schneider XPSMC32ZP Safety Relay
  • Siemens 3VL4740-2AA36-0AA0 Circuit Breaker
  • ABB PharpSFan03000 Mpsiii Fan System Monitor
  • Honeywell DPCB21010002 IRTP131 PCB
  • Siemens 6ES7214-1HG40-0XB0 CPU 1214C
  • Siemens 6ES7350-1AH03-0AE0 FM 350-1
  • PILZ PNOZ mm0.1p 772001 Safety Relay
  • E2V EVX12DS130AGC 12DS130 Module
  • Siemens 3RT5066-6AB36 Contactor
  • HIRSCHMANN RS20-0800T1T1SDAEHC09.1.00 Switch
  • Q4XTILAF500-Q8 Laser Range Sensor
  • OMRON CVM1-BC103 Base Unit 145752
  • CAREL RITC400001 Card
  • Eaton LZMN3-AE400 Molded Case Circuit Breaker
  • Fanuc A20B-3300-0031 Control Circuit Board
  • Siemens 6ES7450-1AP01-0AE0 S7-400 FM 450-1
  • Fanuc A90L-0001-0317/F Spindle Fan Motor
  • Schneider TM262L10MESE8T Logic Controller
  • 8.4-inch NL8060BC21-06 Industrial Display
  • B&R X20CP0411 Compact CPU Control Unit
  • Schneider TSX P572634 M Modicon Premium CPU
  • Omron NX1P2-1140DT-BA Machine Controller
  • Siemens Ams-M35-K202 C8451-A20-A53-7
  • Omron FH-2050 Automation Controller
  • Omron CJ1W-NCF71 Position Control Unit
  • PILZ 777750 Safety Relay
  • BES58-P0CA0P-CD0H3PB0 Encoder 85409
  • Siemens 3VL5763-1DC36-0AA0 Molded Case Breaker
  • FANUC A16B-3200-0010 CPU Card
  • HINE DESIGN R94-1164 PLC Control Box 144760
  • Siemens PCU 50.5-C 6FC5210-0DF52-2AA0
  • PILZ PNOZ M0P Safety Relay 773110
  • Fanuc A20B-2101-0820 Control Circuit Board
  • Siemens 3SK1121-1AB40 Safety Relay
  • Pilz 772120 Safety Relay Expansion Module
  • Mitsubishi AX71 Input Module 16 Point
  • Siemens 6ES7350-1AH03-0AE0 S7-300 Extension
  • Fanuc A16B-3200-0010 CPU Card
  • Omron CJ1W-SCW22 Serial Communication Unit
  • Siemens 6SN1118-0DM21-0AA0 Control Module
  • Renishaw PHC10-3PLUS Controller Module
  • ABB AX521 1SAP250100R0001 Module
  • Omron NA5-9W001B-V1 PLC Module HMI
  • Infineon FF1000R17IE4 IGBT Power Module
  • Omron CJ1W-DA08C Analog Output Module
  • Omron CJ1G CPU45H CJ1H CPU66H CJ1G CPU43H CJ1W PA202
  • Omron CJ1W-DA041 Analog Output Module
  • Inductotherm 170-8031 PLC Control Module
  • Fuji Electric FPB56HR-A10 Programmable Logic Controller
  • Siemens 6SN1145-1BA01-0BA1 Infeed Regenerative Module
  • PILZ 777949 PSWZ X1P Safety Relay
  • Schneider 140NOM25200 DIO Head-end Adaptor
  • Siemens PXC5.E003 Controller BPZ
  • Schneider BMXEHC0800 Fast Counting Module 10kHz
  • Schneider BMXART0814 Isolated Thermocouple Inputs
  • Schneider BMXNOE0100 Ethernet Module 10 100 RJ45
  • LMX06-NS05 Sensor Industrial Proximity Switch
  • Siemens 6SN1145-1BB00-0FA1 Power Supply 156kW
  • Pro-face GP2500-LG41-24V HMI Graphic Panel
  • Keyence CV-3001 Vision System CV3OO1
  • Siemens 6GK5204-2BB10-2AA3 Ethernet Module
  • Pro-face PFXSP5500TPD 10.4in HMI LCD Display
  • Eu Automation 140DRA84000 Modicon Quantum Module
  • Siemens 6FC5210-0DF31-2AA0 Sinumerik PCU 50.3-C
  • Siemens 6SL3040-1NC00-0AA0 Sinumerik NX10.3 Extension
  • Gould AS-884A-111 Modicon 884 Controller
  • Allen Bradley 1336E-BRF30-AA-EN-HA2-L5 Impact Drive
  • Siemens 6FC5110-0BB02-0AA1 Sinumerik 840D CPU Card
  • Pilz 773500 PNOZmulti Expansion Module
  • Siemens 6ES7350-1AH03-0AE0 S7-300 Counter Module
  • Siemens 6FC5110-0DB01-0AA1 Sinumerik 840D Card
  • HPM 1D703-0040 Command 9000 VGA Console Board
  • OMRON CJ1W-PTS52 Temperature Unit
  • Sacs Technique PCD4.M12 Module
  • OMRON CJ1M-CPU11-ETN Ethernet CPU
  • OMRON CJ1M-CPU23 PLC CPU Unit
  • OMRON NX-SID800 Safety Input Unit
  • GE Fanuc Series 90-30 PLC
  • OMRON CJ1W-NCF71 Position Control
  • OMRON CJ1W-AD081-V1 Analog Input
  • OMRON FZ-S2M Vision Camera
  • OMRON R88D-UEP20V Servo Driver
  • OMRON F500-C10-ETN Vision Controller
  • OMRON CS1W-DA041 Analog Output Module
  • PRO-FACE GP577R-TC41-24VP HMI Panel
  • TRUTZSCHLER RAK 1 492-58.430.000 PLC Module
  • OMRON NX-OD5256 Output Module
  • Siemens 6AG1214-1AG40-4XB0 PLC
  • OMRON CJ1W-AD081-V1 Analog Unit
  • OMRON C500-CPU11-E PLC CPU
  • OMRON NX-ECC201 EtherCAT Coupler
  • OMRON F300-A20S Camera Interface
  • Mitsubishi 80173-109-01 PLC Module
  • Fanuc A16B-2200-0141 PCB Board
  • Lenze EPL10200 PLC Module
  • OMRON CJ1M-CPU13 PLC CPU Unit
  • Yaskawa SGMPH-04AAA61D-OY Motor
  • OMRON NX-SOD400 Safety Output
  • Control Techniques V1800 Flux Vector Drive
  • Yaskawa SGDH-04AE-OY Servo Drive
  • OMRON NT-DRT21 DeviceNet Interface
  • OMRON C500-RM001-V1 Remote I/O Master
  • OMRON C500-AD006 Analog Input Module
  • OMRON 3G3MV-A4055 Inverter Drive
  • OMRON F150-C15E-3 Vision Mate Controller
  • OMRON CS1G-CPU44H PLC CPU
  • GE Fanuc DS6800CCIE1E1D CPU Module
  • Omron CP1L-M30DR-A PLC CP1W-CIF01 CPU Unit
  • Heraeus 585923 2M130 M8 Electrode Assembly Sensor
  • Omron C40P-EDT1-D C Series PLC Controller
  • Yaskawa SGMGH-09DCA6F-OY Servo Motor SGDH Driver
  • Datalogic SG-BWS-T4-MT Safety Control Unit Category 4
  • Pro-face PFXLM4301TADDC HMI Controller LT-4301M
  • Mitsubishi FX1N-60MR-DS PLC Main Unit 60 I/O
  • Omron NJ501-1320 Sysmac Database Connection CPU
  • Omron CJ1W-ETN21 Ethernet Unit CJ Series Module
  • Siemens 6ES7517-3AP00-0AB0 CPU 1517-3 PN/DP
  • Pasaban MTC-3052 Fast I/O PLC Module
  • Mitsubishi FX3U-128MR/ES-A PLC
  • OMRON CS1W-CLK21 Controller Link Unit
  • Yokogawa ADV151-E63 Digital Input Module