Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

Bentley 3500/42 Proximitors ®/ Earthquake monitoring module

F: | Au:FAN | DA:2025-07-07 | 824 Br: | 🔊 点击朗读正文 ❚❚ | Share:

Bentley 3500/42 Proximitors ®/  Earthquake monitoring module

Product Overview

Core functions

3500/42 Proximitor ®/  The earthquake monitoring module is a four channel monitoring device that can receive input signals from a proximity probe and seismic sensors, and achieve monitoring functions such as radial vibration, thrust position, eccentricity, differential expansion, acceleration, and velocity through configuration. Its core function is to drive alarm output by comparing the current machine vibration value with the preset alarm threshold, and provide machine status data for operation and maintenance personnel.

Key Features

TMR architecture: Supports triple modular redundancy (TMR) configuration, avoids single point of failure through a 2 out of 3 voting mechanism, and ensures system reliability.

Flexible configuration: Customize channel types, alarm thresholds, filtering parameters, etc. through 3500 rack configuration software to adapt to different monitoring scenarios.

Real time diagnosis: Built in self checking function, quickly locate faults through LED indicator lights and event logs.

Safety certification: Compliant with standards such as IEC 61508, suitable for hazardous areas (such as Class I, Division 1/2).

Product Architecture and Working Principle

Hardware Architecture

Input module: support multiple I/O modules, including internal terminal, external terminal, TMR terminal and terminal module with barrier, and adapt to different sensor wiring requirements (such as Proximitor, accelerometer, speed sensor).

Signal processing: Each channel integrates filtering, amplification, and digitization circuits, supporting bandpass, high pass, and low-pass filtering, with a configurable frequency response range (such as radial vibration channels supporting 1 Hz to 4000 Hz).

Communication interface: communicates with other modules through the rack backplane, supports serial protocols such as RS-232/485, and can be connected to the upper computer for data monitoring.

TMR redundancy mechanism

Voting logic: In the TMR configuration, three monitoring modules vote 2 out of 3 for the input signal. If the deviation between the output of one module and that of other modules exceeds the set threshold (such as% Comparison), event logging will be triggered.

Input configuration:

Bus configuration: A single non redundant sensor signal is distributed to three modules through the bus.

Discrete configuration: Three redundant sensors are connected to three modules respectively to improve reliability.

Data output and status monitoring

Proportional value output: Output different parameters based on channel type, such as Direct (peak to peak), 1X/2X amplitude, phase lag, etc. for radial vibration; Gap (gap voltage) and Direct (axial displacement) at the thrust position.

Status identification: Feedback module health status, communication status, and alarm events through LED (OK, TX/RX, BYPASS) and event logs (System Event List, Alarm Event List).


Configuration Guide

Software Configuration Tool

Use 3500 Rack Configuration Software for parameter settings, with core configuration items including:

Channel type: Select radial vibration, thrust position, etc. Different types correspond to different filtering and scaling factors.

Full range: For example, radial vibration Direct can choose 0-10 mil pp (peak to peak), and acceleration can choose 0-20 g pk (peak to peak).

Alarm threshold: Set the Alert/Alarm 1 and Danger/Alarm 2 thresholds for each proportional value, and support lag adjustment (e.g., hysteresis is 1/64 of full scale).

Filter parameters: Set the cut-off frequency of the high/low-pass filter (e.g. acceleration channel supports 3 Hz to 30 kHz).

Example of Key Parameter Configuration

Radial vibration channel:

Select a 3300-8 mm Proximitor sensor and set the Scale Factor to 200 mV/mil.

Set the 1X Amplitude full-scale to 10 mil pp, the Alert threshold to 6 mil pp, the Danger threshold to 8 mil pp, and the delay time to 1 second.

Thrust position channel:

The Zero Position voltage is set to -9.75 Vdc (corresponding to the center value of the gap), the full range is set to 25-0-25 mil, and the direction is set to "Forward Probe" (displacement increases when the rotor moves towards the probe).

Key points of TMR configuration

Three monitoring modules need to be installed adjacent to each other and configured with Comparison Voting (if comparing 1X Amplitude, a deviation of 5% is allowed).

Bussed External Termination Block is used for bus configuration, while three independent sensors and terminal blocks are used for discrete configuration.

I/O modules and wiring

Module type and function

Internal terminal module: directly connected to sensors and recorders, suitable for non hazardous areas, wiring should pay attention to electrostatic protection (such as using anti-static wrist straps).

Internal Barrier Module: Integrated Zener Barrier, suitable for explosion-proof areas (such as Class I, Division 1), to restrict energy flow into hazardous areas.

External terminal module: Connect the sensor with a 25 pin cable and the recorder with a 9-pin cable to simplify the internal wiring of the rack.

Wiring specifications

Proximitor sensor: The power supply (PWR) is connected to -24 Vdc, the signal (SIG) is connected to the channel input, and the shielding layer (SHLD) is grounded.

Seismic sensors (such as Velomitor) require series connection of resistors and capacitors (such as 4 k Ω resistors+10 μ F capacitors) for signal conditioning.

TMR wiring: In discrete configuration, three sensors are connected to independent channels of three modules, and in bus configuration, sensor signals are shared through a Bussed Terminal Block.


Maintenance and testing

Regular verification testing

Testing cycle: It is recommended to conduct it once a year. If the equipment is a critical unit or operates in harsh environments, it can be shortened to once every quarter.

Testing equipment: function generator, multimeter, oscilloscope, Keyphasor Multiplier/Diverder, etc.

Test steps (taking radial vibration channel as an example):

Simulate sensor signals (such as a 100 Hz sine wave with a peak to peak value of 2 V).

Verify the display accuracy of proportional values such as Direct and 1X Amplitude (error ≤ ± 1% of full scale).

Trigger Alert/Arm 1 and Danger/Arm 2 thresholds, confirm that the alarm delay time is consistent with the configuration.

Disconnect the input signal and verify the OK state recovery time (Timed OK Channel Defeat set to 30 seconds).

Scale factor and zero position adjustment

Scale Factor: Used to calibrate the linearity deviation of sensors, such as the default 200 mV/mil for 3300-8 mm Proximitors, which can be adjusted by ± 15%.

Zero Position: For channels such as thrust position and eccentricity, adjust the voltage to make the displayed value zero (such as setting the zero position of thrust position to -9.75 Vdc, corresponding to mechanical zero position).

Recorder output verification

The 4-20 mA output should correspond to the full-scale proportional value. For example, when the full-scale is 10 mil pp, 20 mA corresponds to 10 mil pp, and 4 mA corresponds to 0 mil pp, with an error of ≤± 1%.


Troubleshooting

LED fault diagnosis

OK light off: It may be due to module failure, hardware malfunction, or sensor disconnection. Check the power and wiring, restart the module, or replace spare parts.

BYPASS light on: The channel is bypassed by software or the sensor is faulty. Check the Software Switches configuration and confirm that the sensor is in an OK state.

TX/RX light does not flash: communication failure, check the rack backplane connection and serial port parameters (baud rate, data bits).

Analysis of System Event List

Event 11 (Flash Memory Failure): Flash memory failure, module replacement required immediately.

Event 62 (I/O Module Mismatch): The I/O module type does not match the software configuration. Check the module model and reconfigure it.

Event 493 (Kph Lost): Keyphasor signal loss. Check the Keyphasor sensor and wiring to confirm if the speed is within the valid range (60-60000 cpm).

Common alarm handling

Alert/Arm 1 trigger: If the vibration value exceeds the threshold, check whether the machine is unbalanced, misaligned, or has bearing faults.

Trigger of Danger/Arm 2: Emergency stop condition, immediately stop the machine and troubleshoot equipment faults. If the shaft displacement exceeds the limit, it may cause dynamic and static friction.


Technical specifications and ordering information

key parameter

Input impedance: Proximitor channel 10 k Ω, TMR configuration with bus mode 50 k Ω and discrete mode 150 k Ω.

Frequency response: The radial vibration Direct channel supports 1 Hz-4000 Hz, and the acceleration channel supports 3 Hz-30 kHz.

Environmental conditions: Operating temperature -30 ℃~65 ℃ (non barrier module), storage temperature -40 ℃~85 ℃, humidity ≤ 95% non condensing.

Order Parts

Monitor module: 3500/42-01-00 (discrete internal terminal, no authentication), 3500/42-03-01 (TMR external terminal, CSA authentication).

Spare parts: I/O module (such as 128229-01), terminal block (125808-02 Euro style), cable (129525-0010-01, 10 foot assembly cable).


Safety and Compliance

Explosion proof certification: With barrier module supporting Class I, Division 1 (Groups A-D) and EEx ia IIC, suitable for explosive gas environments.

Static protection: When operating the module, wear an anti-static wrist strap and store it in a conductive bag to prevent static electricity from damaging the circuit board.

Maintenance warning: When hot plugging modules, ensure that the rack is powered off to avoid the risk of short circuit or electric shock caused by live operation.

BENTLY 3500/42M 128229-01 Proximitor Seismic Monitor module Competitive ...

  • GE IS2I5WEMAHIA+IS210BPPBHZCAA Mark VIe Safety Controller & I/O Module Set
  • GE IS2I5AEPAHICH+IS210BPPBHZCAA Mark VIe Analog I/O Control Module Set
  • GE IS2I5WECAH1B+IS2108PPBHZCAA Mark VIe Controller Redundant I/O Set
  • VMIC HSDA 332-000111 Scanning Analog-to-Digital Converter Module
  • GE VMIC VMIVME1150B VME Module
  • FANUC VMIVME3128 VME Digital I/O Board
  • GE Fanuc VMIVME-7697-350 VMEbus Single Board Computer
  • GE Fanuc VMIVME-4150 PLC Board
  • FANUC VMIVME-1160A VMEbus Module
  • GE Fanuc VMIVME-4116 VMEbus CPU Processor Controller
  • FANUC VMIVME-9300 VMEbus Module
  • VMIVME-7589A Pentium VMEbus CPU Board
  • GE Fanuc VMIPCI-7767-13100 PCI Board
  • GE Fanuc VMIVME-4140 VMEbus Module
  • IS415UCVGH1A VME Controller Card
  • VMIC VMIVME-1150 VME Circuit Board
  • VMIC VMIVME7589 Processor Board
  • FANUC VMIVME-2200 VME Circuit Board
  • IS215UCVEH2A VME Controller Card
  • VMIC VMIVME-7589A-446 VMEbus CPU SBC
  • VMIC VMIVME-7658-330 VME Single Board Computer
  • VMIC SEMIVISION OPAL VMEbus CPU Module with VMIVME-7588
  • GE Fanuc VMIVME-4140 VME Module
  • Abaco VMIVME 2532A 32-Bit High-Voltage Digital I/O Board – VMEbus
  • VMIC VMIVME 100-Pin VME Bus I/O Cables
  • VMIC ASSY 11994R13 VMEbus Module
  • GE Fanuc VMIVME 1182 VMEbus Input Board – 332-011182-030A
  • VMIC VMIVME-7589 VMEbus Module with VMIVME-7434
  • VMIC VMIVME-7588-787 Single Board Computer – 332-250236
  • VMIC 7487A VMEbus CPU Board – 332-107487-033 H
  • FANUC VMIVME-3125 VMEbus Analog Input Board
  • VMIC VMIVME 6015 VMEbus Board – 332-006015-000
  • VMIC ASSY 11993R2 VMEbus Module
  • Cisco 2851 Router with VMIC2-1MFT-T1/E1 Module
  • Applied Materials VMIC 7505 800MHz CPCI SBC
  • VMIVME-2534-046D 32-Bit High-Voltage Digital I/O Board
  • VMIC 5530M Optical Extender PCB Board
  • GE VMIC XVB602 Control Module
  • VMIVME-6005-020 Octal ARINC-429 Controller
  • VMIC VMI PCI 3322 Board
  • FANUC VMIVME-7487 VME Processor Board
  • VMIC 332-800576-000A VMIACC 0576 Module
  • VMIC VMIVME-7805-231000 VME Board
  • ABACO VMIC VMICBL-000-F3-102 Reflective Memory Cable
  • VMIC 332-000131-B VMIVME PCB Card
  • VMIC 320-250236 with VMIVME-7588 Processor Board
  • VMIC ASSY 12149 Module
  • FANUC VMIC VMIVME5010 I/O PCB Board
  • VMIC VMIVME-7698-345 VME Single Board Computer
  • IS215UCVEH2A VME Controller Card
  • VMIC VMIVME-7658-330 VME Single Board Computer
  • VMIC VMIPCI-5790-000 Dual-Channel Ultra160 SCSI Adapter
  • VMIC VMICPCI-7756-460 Single Board Computer
  • VMIVME-4920 Dual Channel Digital Converter Board – VMEbus
  • GE Fanuc VMIVME-4140 VMEbus Module
  • VMIC VMIPMC-7440 PMC Sound Card
  • VMIC PCI 4320 VMEbus Board-333-854320-000
  • VMIC VMIVME 5530S VMEbus Interface Module
  • FANUC 332-999995-000 VMEbus PCB Assembly
  • FANUC VMIVME-4116-030 VMEbus Module
  • VMIC VMIVME-7658-330 VMEbus Single Board Computer
  • VMIC VME-2532A VMIVME2532A-413 Digital I/O Board
  • VMIC VMIVME-7696-650 VMEbus Processor Board
  • VMIC VMIVME-7487A Mainframe Board
  • GE Fanuc VMIVME-2120-175 Digital Output Board
  • Abaco VMIVME-4125A-000 System Test Calibration Board
  • VMIC VMICPCI-5579 Reflective Memory PCI Board
  • FANUC A860-2000-X003 Encoder Interface Module
  • FANUC 332-999992-000 VME Module
  • VMIC VMIVME-7698 VME Module
  • FANUC A860-2000-X003 Encoder Interface Module
  • VMIC 333-657755-000 B LSC-3 4201 Board
  • VMIVME-9304 CPU Board with NEC FGA-002A Interface Chip
  • VMIC VMIVME-7805 VMEbus Board – VMIVME-7805-234001
  • VMIC 332-000131-000M01 VMIVME PCB Card
  • FANUC GE VMIC VMIVME 2510B Digital I/O Board
  • VMIC VMIPMC-5795-000 PMC Ultra160 SCSI Adapter
  • GE Fanuc VMIVME 5588 High-Speed Reflective Memory Board
  • VMIC VMIVME 4132 VMEbus Analog Output Board
  • VMIC VMIVME-3418 8-Channel Strain Gauge and RTD Board
  • VMIC VMIPMC-5797-000 Ultra320 SCSI Host Bus Adapter
  • VMIC VMIACC 0562 Accessory Module
  • Abaco VMIVME 4116 8-Channel 16-Bit Analog Output Board
  • VMIC VMIVME 4512 Analog I/O Board – 332-004512-300
  • VMIC VMIVME 4120 VMEbus Circuit Board – 332-004120
  • VMIC VMIVME-3801-100C Analog-to-Digital Converter Module
  • IS215UCVEH2AE VME Controller Card
  • FANUC 333-00DMA0-000 VME Module
  • GE Fanuc VMIVME-5588-200 High-Speed Reflective Memory Card
  • VMIC VMIVME-7696-650 VMEbus Single-Board Computer
  • GE Fanuc VMIVME-5532S VMEbus Fiber-Optic Repeater Link
  • VMIC GE EV-DIO-01 Control Board
  • Abaco VMIVME-7751 Pentium III VME Single Board Computer
  • PMC-5565PIORC-110000 128MB Reflective Memory Card
  • Abaco VMIVME-5565-010000 Reflective Memory Board
  • VMIC VMIPMC-5565 Reflective Memory PMC Module
  • VMIC VMIVME 5504 Slave VME Module
  • VMIC VMIVME-5740-12000 VMEbus Hard Drive Module
  • VMIC VMIVME-7751 VMEbus Processor Module
  • VMIC VMIVME-7588 CPU Module
  • VMIC 332-000132 VMIVME PCB Card
  • GE Fanuc VMIVME-4514A Analog I/O Board
  • Abaco VMIVME-2528-000 128-Bit TTL Digital I/O
  • VMIC VMIVME 4514 Scanning Analog I/O Board
  • VMIPCI 5588-101 High Speed Fiber Optic Reflective Memory Card
  • VMIC VMIVME-1228 VMEbus Board
  • VMIC VMIVME-7455 CD-ROM Drive Module
  • VMIC VMIACC 0577 Compact PCI Board
  • IS415UCVGH1A VME Controller Card
  • VMICPMC-5664 VME PMC Dual Fiber Card
  • VMIVME1128 128-Bit High-Voltage Digital Output Board
  • VMIC VMIVME-2170A VMEbus PCB Board
  • VMIC 332-015565-010L VME Module
  • VMIC VMICPCI-7612-470 Single Board Computer
  • VMIC EV-CNT/01 Control Board
  • VMIC VMIVME 1181 VMEbus Input Board – 333-001181-000 A
  • VMIC VMIVME-1150 VMEbus Module
  • VMIC VMIVME-5576 VMEbus Module
  • VMIC VMIVME-4150 VMEbus Module
  • VMIC VMIOMAX-8001B PLC Rack
  • VMIC VMIVME 2128 High-Voltage Digital Output Board
  • VMIC VMIVME-1111 64-Bit High-Voltage Digital Input Board
  • GE Fanuc VMIVME 1182 VMEbus Input Board – 332-011182-060C
  • VMIC VMIVME-7696 VMEbus PC Board
  • VMIC VMIVME-7686 VMEbus Module
  • GE VMIVME-7486 VME PCB Board
  • VMIC VMIVME-7740-840 Processor Module
  • VMIC VMIACC BT01 REV 0 Transition Board