Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

ADLINK MXE-1300 Industrial Control Computer Selection and Deployment Guide

F: | Au:FANS | DA:2026-08-06 | 341 Br: | 🔊 点击朗读正文 ❚❚ | Share:

Programming: ADLINK provides an API library (Matrix DIO) that supports functions such as GPIOInitialize, GPI-Read, and GPOWrites, similar to MXE-200 but with a different model.

3.4 PCIe Mini Card and USIM Expansion

Built in a full height PCIe Mini Card slot, supporting WiFi, Bluetooth, 3G/4G modules GPS、 Video capture card or security module (SAM). The matching USIM card holder is used for cellular communication. Attention should be paid during installation:

Module fixation: Use the two M2.5 screws provided to secure and prevent vibration and detachment.

Antenna wiring: If a wireless module is used, the antenna needs to be led out to the outside of the chassis. It is recommended to use SMA interface for installation through panel openings, and the length of the antenna feed line should be as short as possible (<30cm) to reduce attenuation.

Driver compatibility: Under Windows 7/XP, the corresponding module driver needs to be installed. If using a 3G module, dial-up connection also needs to be configured.

Storage solution and wide temperature deployment

MXE-1300 offers three storage methods:

SATA-II: It can install 2.5-inch HDD or SSD internally (connected to the motherboard SATA interface).

External CF card slot: Supports Type I CF cards (supporting PIO/DMA mode), and can directly boot the system from the CF card.

Optional Pre installed Storage: Factory installed with 500GB HDD (0-60 ℃), 32GB MLC SSD (0-70 ℃), or 8GB SLC industrial grade SSD (-40~85 ℃).

Key engineering decisions:

If the on-site ambient temperature is below 0 ℃ or above 60 ℃, industrial grade SLC SSD or CF card must be selected. Ordinary HDD and commercial SSD may not start at low temperatures (due to motor grease solidification or deterioration of electrical characteristics of flash memory particles).

If the system needs to frequently read and write logs and avoid using CF cards (with limited write life), SLC SSDs should be used and wear balance should be enabled.

The external CF card slot is convenient for system upgrades or configuration changes, but please note that the card body protrudes from the chassis and needs to be dust-proof and waterproof.

Wide temperature verification: According to the manual, when paired with industrial grade SSD or CF, MXE-1300 can operate stably at -20 ℃~70 ℃ (Extended Temperature Option needs to be ordered, which is actually a screening service). If you purchase wide temperature storage on your own, you also need to ensure that the overall heat dissipation design meets the requirements - maintain at least 5cm of space at the top of the chassis to avoid direct sunlight or heat source radiation.


Software support and driver deployment

MXE-1300 officially supports Windows 7/Embedded 7 (32-bit) and Windows XP/XP Embedded (32-bit, but XP support has limitations, please refer to the official website). Not pre installed with Linux, but ADLINK provides Linux BSP (please contact technical support).

Suggested installation sequence for drivers (similar to MXE-200):

Chipset driver (Intel NM10)

Graphics card driver (integrated GMA 3600/3650, supports VGA+DVI dual display, up to 1920 × 1200)

Network card driver (Intel 82574L)

USB 3.0? This model is USB 2.0 and does not require special drivers.

Serial port/I/O driver (used to switch between 422/485 and DIO functions)

Watchdog and SEMA tool (for system health monitoring and fault self recovery)

Special reminder: If installing Windows 7, it is necessary to inject the AHCI driver in advance (if using a SATA hard drive), otherwise there may be a blue screen. It is recommended to set SATA mode to IDE compatible mode in BIOS (if the driver is not integrated), or use a tool to preload the driver.


Watchdog and Remote Monitoring (SEMA)

MXE-1300 integrates a hardware watchdog timer (WDT) that can automatically reset when the system crashes. The programming interface is similar to MXE-200, and the calling sequence is:

InitWDT() -> SetWDT(tick, unit) -> StartWDT(), Then in the main loop, ResetWDT() feeds the dog. If the timeout occurs, the system will reset.

At the same time, ADLINK's SEMA (Smart Embedded Management Agent) tool provides remote monitoring functionality, allowing real-time viewing of CPU temperature, system voltage, runtime, and other information, as well as setting threshold alarms. At unmanned stations (such as roadside traffic control boxes), SEMA combined with WDT can effectively reduce the frequency of operation and maintenance attendance.


Power supply design and grounding specifications

The MXE-1300 adopts 3-pin DC input terminals (GND, V -, V+), supports a wide voltage range of 6-36V, and is suitable for vehicle batteries (12V/24V) or industrial switch power supplies (24V). Notes:

The polarity must never be reversed, otherwise the internal protective diode may burn out.

It is recommended to parallel TVS tubes (such as SMBJ24A) and varistors on the input side to absorb power grid surges.

Use shielded power cords with the shielding layer grounded at a single point at the power end to reduce common mode interference.

If using a 90W AC-DC adapter, it is necessary to ensure that its operating temperature is within the range of 0-50 ℃ (commercial grade). If it is used in high temperature environments (such as outdoor cabinets), an industrial grade power supply should be selected.

  • SIGMATEK ICA111 Module
  • SIGMATEK MDD 121-1 Drive Axis Module
  • SIGMATEK M5V121 12-300-121 Krauss Maffei M5 Display Unit
  • SIGMATEK CTMS 020 CD Technology Module 12-250-011
  • SIGMATEK PCT122 Touch Panel
  • Stöger MCS4100 SIGMATEK Control Module
  • SIGMATEK Krauss Maffei M5 Keyboard Unit M5K902 12-310-902
  • SIGMATEK SD310-2 Servo Drive Module
  • SIGMATEK CM5V020 CD Wiring Circuit Module
  • SIGMATEK ENGEL Robot Drive M3 02220-8748
  • Sigmatek CFF011 Drive Module
  • Sigmatek DCP642 DIAS Central Unit
  • Sigmatek SDM081 S-DIAS Safety Module
  • Sigmatek C-IPC 01-450-024 Industrial PC
  • Sigmatek Kompakt NC4 Control Module
  • Sigmatek VI021 VARAN Interface Module
  • Sigmatek Engel RD-M6-2 Robot Drive
  • Sigmatek CNC031 Positioning Module
  • Sigmatek TO161 Digital Output Module
  • Sigmatek CCL912 CPU PSU Module
  • Sigmatek ETV0821 Operator Terminal
  • SIGMATEK ET 261 Operator Terminal
  • SIGMATEK CP731-K Control Module 20-004-731-K
  • SIGMATEK ETEK Motherboard 12-250-021-K CM5V020
  • Sigmatek DEZ 181 DIAS Input Output Module
  • Sigmatek IPC111-D Industrial PC
  • SIGMATEK AKM54L-ANC2GBB0 Servomotor with Gearhead
  • SIGMATEK CTMS020 CM5V020 CNC Controller
  • DEMAG ERGOTECH 061 381 66 Sigmatek Control Unit
  • Sigmatek DAI 883 Module
  • Sigmatek ETV1521 Control Panel Installation Terminal
  • Sigmatek 9802.289.01 Board Control TA71 Display
  • Wittmann Sigmatek EU-252 proDrive W4 Servo Drive
  • Sigmatek CDM166 C-DIAS Module
  • Sigmatek DCP082 DIAS Central Unit
  • Sigmatek CCP081 C-DIAS Processor Module
  • Sigmatek MD111-1 Drive Module
  • Sigmatek ETV0821 Operator Terminal
  • Sigmatek ISE021 Interface Module
  • Sigmatek DCC080L Slide Control Module
  • Sigmatek AI075 Analog Input Module
  • SIGMATEK TO161 20-007-161 Module
  • SIGMATEK CIC011 Module
  • SIGMATEK AE0000318502 Hand Terminal Pendant
  • Sigmatek Krauss Maffei PC323-K Control Unit
  • Sigmatek Krauss Maffei PC321-K Control Cabinet PC
  • SIGMATEK CIV521 Control Module
  • SIGMATEK C-IPC-171 Industrial PC
  • SIGMATEK MDP101-L DIAS Drive Network Module
  • Sigmatek Krauss Maffei PC323-K Control Cabinet PC
  • SIGMATEK CRCH081 C-SLIDES Temperature Module
  • Sigmatek PC301-E6 Industrial PC SSD
  • Sigmatek SDI101 S-SLIDES Safety Input Module
  • Sigmatek CIV521 VARAN Control Module
  • Kollmorgen Sigmatek AKM42G-ANCNGBB0 Servo Motor
  • Sigmatek PC 521 Process Controller
  • Sigmatek Geode LX800 12-780-012 Industrial PC
  • Sigmatek STO081 S-DIAS Safety Output Module
  • Sigmatek SCP111 S-DIAS Safety CPU Module
  • Sigmatek CDI161 Industrial I O Module
  • Sigmatek Wiring Board V2 DIAS 05-250-023
  • Sigmatek CP102 20-004-102 S-DIAS CPU Module
  • SIGMATEK SLIDES CNC 115 Module
  • SIGMATEK DCC080 05-700-080-2 Control Module
  • SIGMATEK MDD 121 Drive Axis Module
  • SIGMATEK CIO011 C-DIAS Multi I/O Module
  • SIGMATEK CIV512 Servo Drive
  • SIGMATEK CM5V020 12-250-021-K Wiring Module
  • SIGMATEK CIO011 12-013-011 Multi I/O Module
  • SIGMATEK 01-450-031 C-IPC Industrial Computer
  • SIGMATEK AKM24D-ANBNGBB0 Servo Motor
  • DEMAG NC4 LP0001289.03 Control Module
  • Sigmatek ETEK Industrial PC C-IPC with Option Module
  • Sigmatek AO081 20-010-081 Analog Output Module
  • Sigmatek CNC 031 Positioning Module
  • Sigmatek CP731-K 20-004-731-K CPU Module
  • Sigmatek MDD 3320-JR-A Drive Module
  • Sigmatek PM Servo Motor AKM52K-ANC2GBB0
  • Sigmatek MDP 101 09-403-101 Power Module
  • Sigmatek S-SLIDES AO046 Analog Output Module
  • Sigmatek ICA111 20-102-111 Interface Module
  • SIGMATEK DCP646 Module 05-004-646
  • SIGMATEK SDI101 Digital Input Module 20-891-101
  • SIGMATEK S3330-2 Directional Gyro Altitude Instrument
  • SIGMATEK MDP102-1 Controller
  • SIGMATEK SMT 01-230-321 Touch Screen
  • SIGMATEK Krauss Maffei PC301-K 01-310-301-K Industrial PC with 8GB SSD
  • SIGMATEK ETT731 01-230-731 Built-in Touch Terminal
  • SIGMATEK CIV521 Control Module
  • SIGMATEK DME 128 Module 05-005-128
  • SIGMATEK SCP111-S 20-890-111-S S-DIAS Safety CPU Module
  • Sigmatek SCP111 S-DIAS Safety CPU
  • Sigmatek CRIF081 Interface Module
  • Sigmatek CP112-1 S-DIAS CPU Module
  • Sigmatek MDD121-L DIAS Drive Axis Module
  • Sigmatek C-IPC 01-450-024 Industrial PC
  • Sigmatek SDD215-23 SLIDES Drive
  • Sigmatek DPS001 DIAS System Components
  • Sigma-Tek 4000B-30 Directional Gyro
  • Sigmatek SDD340-46 SDD Series Drive
  • Sigmatek CEZ221 Euromap67 I O Module
  • SIGMATEK VI021 Interface Module
  • SIGMATEK CP731-K Control Module
  • SIGMATEK Krauss Maffei PC321-K Industrial PC
  • SIGMATEK ET322 Operator Terminal
  • SIGMATEK CP102 Control Module 24VDC
  • SIGMATEK SRO021 Relay Output Module
  • SIGMATEK DCP640 DIAS Central Unit
  • SIGMATEK MDD 121 Drive Axis Module
  • SIGMATEK AI043 Analog Input Module
  • ENOTEC OXITEC 5000 SME-53310000 Oxygen Analyzer
  • SIGMATEK Krauss Maffei PC301-K 01-310-301-K Industrial PC
  • SIGMATEK SDD310-23 VARAN Servo Drive
  • SIGMATEK CDM 163 and CIC 011 C-DIAS Input Modules
  • SIGMATEK MDP 101-1 Power Module
  • SIGMATEK CM5V020 Wiring Circuit with CTMS020
  • SIGMATEK CCP521 C-DIAS Processor Module
  • SIGMATEK MDP 101-K Power Module
  • SIGMATEK ETEK C-IPC 733MHz VIA Eden 7000
  • SIGMATEK DCP 643 DIAS PLC CPU Module
  • SIGMATEK TAE121 12-200-121 Operator Terminal
  • Sigmatek TMS012-T Injection Moulding Technology Module
  • Sigmatek MDD 121-1 Controller
  • Sigmatek CDM167 Module
  • Sigmatek DCP082 DIAS Central Unit
  • Sigmatek ETT731 Built-In Terminal Touch
  • Sigmatek CCP521 C-DIAS Processor Module
  • Sigmatek Krauss Maffei PC301-K Control Cabinet PC