Watlow DIN-A-MITE ® Style C Solid State Power Controller

来源: | 作者:FAN | 发布时间 :2025-11-11 | 516 次浏览: | 🔊 Click to read aloud ❚❚ | Share:

Watlow DIN-A-MITE ®  Style C Solid State Power Controller

Product basic information and manufacturer background

1. Product positioning and manual usage

This product is an industrial grade solid-state power controller, with the model identification as "DIN-A-MITE ®  Style C”, The manual clearly states that its core function is to guide users in completing product installation, wiring, parameter configuration, and safe operation and maintenance. It also includes specifications and recommended solutions for semiconductor fuses that users are concerned about, and emphasizes the need to follow national and local electrical safety regulations during installation.

2. Core configuration range of the product

Electrical basic parameters: Supports single-phase, three-phase 2-leg, and three-phase 3-leg (suitable for four wire star loads) configurations, with AC voltage coverage of 120-600V (ac) and current switching capability ranging from 30-80A depending on the model. Please refer to the output rated curve for specific specifications 🔶 1-9.

Control and protection options: Provide zero crossing variable time base or AC/DC input contactor versions, some zero crossing models have thyristor (SCR) short circuit protection and heater open circuit protection; Single phase models additionally support phase angle control and phase angle control with current limitation, and product configuration information can be directly identified through model coding.



Detailed technical specifications

1. General electrical parameters

(1) Current is related to power

Rated current: Please refer to the output rated curve on page 5. Different cooling methods (natural convection, fan cooling, through wall installation) and load types (resistive heater load) correspond to different rated values, and it is clear that the rated value is based on the resistive heater load 🔶 1-22.

Transient and limit current: The maximum peak surge current within 16.6 milliseconds is 1350A; the selection of fuses must meet the maximum value of 9100 A ² s for I ² t; The minimum latch current of SCR is 500mA, and the minimum holding current is 200mA to ensure stable triggering and operation of the device 🔶 1-24 🔶 1-25 🔶 1-26.

Auxiliary current and power consumption: The fan current varies depending on the power supply -0.14A at 24V (dc), 0.12A at 120V (ac), 0.06A at 240V (ac); the maximum off state leakage current is 1mA at 25 ° C (77 ° F); the power loss of each controlled branch is 1.2 watts/ampere (calculated based on switching ammeter) 🔶 1-28 🔶 1-29.

(2) Voltage range

Segmented by voltage level input range: 24-48V (ac) models with minimum 20V and maximum 53V; 120-240V (ac) models with minimum 48V and maximum 265V; 277-600V (ac) models with minimum 85V and maximum 660V, covering commonly used industrial voltage scenarios and adapting to different regional power grids 🔶 1-33 🔶 1-34.

(3) Environmental adaptability

The working humidity is 0-90% relative humidity (without condensation), and the storage temperature range is -40 to+85 ° C (-40 to 185 ° F); The insulation performance has only been tested below an altitude of 3000 meters, and additional evaluation is required for high-altitude scenarios 🔶 1-74 🔶 1-75; Simultaneously passing IEC 60068-2-32 (impact) and IEC 60068-2-6 (vibration) tests to ensure the anti-interference ability of industrial environments 🔶 1-59.

2. Operator interface and alarm function

(1) Interface configuration

Standard configuration includes command signal input and indicator lights, alarm output and indicator lights, and current limit indicator LEDs. Users can intuitively monitor the operating status of the equipment and quickly identify key working conditions such as signal input, alarm triggering, and current limit 🔶 1-18 🔶 1-19.

(2) Alarm function (limited to zero crossing models only)

SCR short circuit alarm: When the input command signal is turned off, but the current transformer detects a load current of 10A or above, an alarm is triggered (2 turns of winding are required for 5A current, 3 turns of winding are required for 2.5A current), and the alarm state is an abnormal combination of "signal off+load current present".

Heater open circuit alarm: Only applicable to models with input control signal option "S". It is triggered when the input command signal is turned on, but the load current detected by the current transformer is lower than the alarm set value, covering the fault scenario of "signal on+insufficient current".

Alarm output characteristics: The alarm output is non latch type and is powered on when triggered; Adopting bidirectional thyristor (Triac) output, compatible with external power supply of 24-240V (ac), rated current varies at different temperatures -300mA at 25 ° C (77 ° F), 200mA at 50 ° C (122 ° F), 100mA at 80 ° C (176 ° F), typical holding current of 200 μ A, latch current of 5mA 🔶 1-42.

3. Certification and Security Compliance

International certification: meets ROHS environmental requirements; CE certification requires the use of appropriate filters to cover the 2004/108/EC Electromagnetic Compatibility Directive (EN 61326 Industrial Immunity Class A emission, not applicable to Class B environment) and the 2006/95/EC Low Voltage Directive (EN 50178 safety requirements), but phase angle and phase angle input control signal types with current limitation (P and L) do not have CE certification 🔶 1-45 🔶 1-46 🔶 1-47 🔶 1-48 🔶 1-49 🔶 1-50 🔶 1-51.

North American certification: UL ®  50 Type 4X shell certification, UL ANSI/ISA 12.12.01 temperature code T4A; The through wall heat sink component is suitable for Class I, Zone 2, Groups A, B, C, and D hazardous and non hazardous areas, but safety warnings such as "replacing any component may affect the applicability of hazardous areas" and "cannot be disconnected when the circuit is live unless the area confirms that there is no flammable concentration" are clearly stated 🔶 1-54 🔶 1-55 🔶 1-56; Simultaneously for UL ®  508 listed products, C-UL ®  Document number E73741.

image.png

Installation specifications and size requirements

1. Installation method and steps

(1) DIN rail installation (DIN EN 50022, 35 × 7.5mm rail)

Installation steps: ① Push the device in and press down to clamp the top rail hook into the rail; ② Rotate the bottom of the device towards the guide rail; ③ The guide rail buckle will "click" to fasten. If it is not fastened, check whether the guide rail is bent; ④ The heat sink must be installed vertically (core requirement to ensure heat dissipation efficiency) 🔶 1-223 🔶 1-224 🔶 1-225.

Disassembly steps: Press and release the buckle, while rotating the device upwards and away from the guide rail to remove it.

Spacing requirement: A 102mm (4.0 inches) gap should be reserved on the side for airflow and wire bending radius; The front is designed with anti touch features, requiring no additional clearance; Minimum snap distance 34.8mm (1.37 inches), maximum 35.3mm (1.39 inches) 🔶 1-236 🔶 1-245.

(2) Panel installation

Four M4 (# 8) fasteners are required for fixation. Please refer to the panel installation dimension diagram on page 7 of the manual for specific dimensions, with a focus on the grounding wire entry position (13mm/0.50 inches) and the parallel arrangement wire gap (83mm/3.25 inches).

(3) Wall through installation (UL) ®  50 Type 4X Shell Model

Additional materials: 1 silicone gasket, 8 M5 screws and locking washers, 1 DIN-A-MITE C wall penetrating device 🔶 1-253 🔶 1-254 🔶 1-255.

Installation steps: ① Drill holes and cut the panel according to the size diagram on the right; ② Remove the mounting screws from the heat sink; ③ Tear off the protective film of the silicone gasket, attach the gasket to the heat sink, and ensure that the gasket hole is aligned with the heat sink screw hole; ④ Vertically install heat sink, torque controlled at 2.26-2.82 Nm (20-25 inch pounds) 🔶 1-257 🔶 1-258 🔶 1-259.

Size and Gap: The panel opening should meet the contour requirements of 178mm (7.00 inches) × 122mm (4.81 inches), and a minimum gap of 102mm (4.0 inches) should be reserved above and below the heat sink for airflow. A minimum gap of 10mm (0.4 inches) should be reserved on both sides.

2. Requirements for wiring terminals

(1) Input terminal (control signal type)

Adopting a crimping design, compatible with 0.2-1.5mm ² (24-16 AWG) wires; Use a 3.5mm (1/8 inch) flathead screwdriver and tighten to a torque of 0.5 Nm (4.4 inch pounds); The stripping length of the wire is 5.5mm (0.22 inches); The insulation level of the wire must be ≥ 75 ° C and is only applicable to copper conductors 🔶 1-61 🔶 1-62 🔶 1-63 🔶 1-64.

(2) Main circuit terminals (phase line, load, grounding)

Also of crimping type, compatible with 2.5-25mm ² (14-3 AWG) wires; Can be tightened with a 6.4mm (1/4 inch) flathead screwdriver or a 1A type # 2 Pozidriv screwdriver to a torque of 2.7 Nm (24 inch pounds); Wire stripping length 11mm (7/16 inches); Core maintenance requirement: Re tighten after 48 hours (to reduce wire cold flow), and then re tighten every 3-6 months thereafter 🔶 1-66 🔶 1-67 🔶 1-68 🔶 1-69 🔶 1-70.

(3) Cooling fan terminal

Adopting a quick connect design (1/8 inch push in), compatible with 16-14 AWG wires; Recommend using Amp part number 640929-1 or equivalent product 🔶 1-85.


Control mode and signal configuration

1. Zero crossing control mode (including contactor and proportional control)

(1) Type of contactor (input control signal)

DC input (Type C): 4.5-32V (DC) input, with a maximum current of 6mA per channel at 4.5V. An additional 2mA total current is required for each additional LED; To extend the service life, the cycle time should be less than 3 seconds 🔶 1-94.

AC input (Type K): Suitable for 24V (ac) ± 10%, 120V (ac)+10%/-25%, 240V (ac)+10%/-25%, with a maximum current of 25mA per circuit; it is strictly prohibited to share with temperature controllers with RC buffer circuits. If used, the RC buffer circuit must be removed first; Cycle time should be less than 3 seconds to extend lifespan 🔶 1-95 🔶 1-98.

(2) Proportional control (Type F, 4-20mA DC)

Variable time base control for loop power supply, only applicable to F0 input option; A current source of 8.0V (dc) or higher is required, with no more than 2 series inputs; Linearity requirements: Full open point 19.5-19.9mA (dc), maximum peak voltage 6.2V; Input output power accuracy ± 5% (0% -100% range, 4.3-19.7mA or 12.3-19.7mA); Temperature stability<0.15%/° C 🔶 1-96 🔶 1-102 🔶 1-105 🔶 1-106.

2. Phase angle and single cycle variable time base control

(1) Phase angle control (single-phase specific)

Applicable models: Type P (pure phase angle), Type L (phase angle with current limitation), only supports single-phase configuration, and has no alarm option 🔶 1-111.

Input signal: Supports 0-20mA, 4-20mA, 12-20mA (DC) and 0-5V, 1-5V, 0-10V (DC); Input impedance: 4-20mA signal is 250 Ω, linear voltage signal is 5k Ω 🔶 1-112.

Output and accuracy: Output voltage covers 100-120V, 200-208V, 230-240V, 277V, 400V, 480V, 600V (ac), deviation -15%/+10%, frequency 50/60Hz (deviation ± 5%); At 25 ° C, the output conduction time is directly proportional to the command signal, with an accuracy of ± 5%; Temperature stability<0.25%/° C 🔶 1-115 🔶 1-117.

Soft start function: 5-second soft start when powered on, soft start when thermostat overtemperature occurs, soft start when half cycle dropout detection occurs, 1-second soft switching when set value changes, protecting load and devices 🔶 1-124 🔶 1-125 🔶 1-126.

(2) Single cycle variable time base (Type S)

Working logic: At 50% power, "1 cycle on, 1 cycle off"; At 25% power, "conduct for 1 cycle and close for 3 cycles"; Continuous conduction for no more than 1 cycle when power is less than 50%, and continuous shutdown for no more than 1 cycle when power is greater than 50% 🔶 1-110.

Accuracy and adaptability: The output power is proportional to the command signal at 25 ° C, with an accuracy of ± 5%; Temperature stability<0.25%/° C; supports linear voltage, 4-20mA or potentiometer input 🔶 1-120.

3. Resolution and Additional Options

Resolution: The accuracy of the output variation relative to the input range is greater than 0.1%.

Manual control kit: Optional 1k Ω single turn potentiometer (with 0-100% dial), part number 08-5362.

image.png

Ordering coding rules and current levels

1. Model code disassembly (complete code: DC+phase+cooling/current+voltage+control signal+alarm+language+customization)

Meaning and Options of Encoding Segments

DC prefix: Fixed identifier (DIN-A-MITE Style C)

Phase configuration 1=single-phase 1 controlled leg; 2=Three phase 2 controlled legs; 3=Three phase, three controlled legs (four wire star); 8=2 independent area; 9=3 independent areas

Cooling/current 0=natural convection (standard DIN rail/panel heat sink); 1=120V AC fan cooling; 2=240V AC fan cooling; 3=24V DC fan cooling; T=Natural convection (wall/cabinet type heat sink, UL 50)

Voltage level 02=24-48V AC (C/F/K control); 12=100-120V AC (L/P/S control); 20=200-208V AC (L/P/S control); 24=120-240V AC(C/F/K)/230-240V AC(L/P/S); 27=277V AC(L/P/S); 40=400V AC(L/P/S); 48=480V AC(L/P/S); 60=277-600V AC(C/F/K)/600V AC(L/P/S)

Control signal C0=4.5-32V DC contactor; K1=22-26V AC contactor; K2=100-120V AC contactor; K3=200-240V AC contactor; F0=4-20mA ratio (loop power supply); L (0-5)=phase angle with current limitation (single-phase); P (0-5)=phase angle (single-phase); S (0-5)=single cycle variable time base; Input types corresponding to 0-5 in parentheses: 0=4-20mA, 1=12-20mA (S only), 2=0-20mA, 3=0-5V DC, 4=1-5V DC, 5=0-10V DC

Alarm option 0=No alarm; S=SCR short circuit alarm (not applicable to 8/9 area or L/P control); H=heater open circuit+SCR short circuit alarm (only S control)

Manual language 0=English; 1=German; 2=Spanish; 3=French

Customized option 00=standard parts; 1X=1-second soft start (P/L control); XX=Custom Options/Identification

2. Current level table (by model prefix)

Model prefix Current level Remarks

DC10 55A natural convection (standard heat sink)

DC1T 62A natural convection (through wall/cabinet type heat sink)

DC11/DC12/DC13 75A fan cooling (120V AC/240V AC/24V DC)

DC20/DC80 40A three-phase 2-leg/2-zone, natural convection

DC2T/DC8T 46A three-phase 2-leg/2-zone, through wall heat sink

DC81/DC82/DC83/DC30/DC90 30A 2-zone fan cooling/three-phase 3-leg/3-zone natural convection

DC3T/DC9T 35A three-phase 3 leg/3 area, wall penetrating heat sink

DC31/DC32/DC33/DC91/DC92/DC93 55A three-phase 3 leg/3 zone, fan cooling


Selection of fuses and EMI filtering

1. Semiconductor fuse (suitable for applications with 600V AC and below)

Rated current of fuse Watlow fuse model Bussman fuse model Watlow bracket model Ferraz bracket model

30A 17-8030 FWP30A14F 17-5114 USM141i

40A 17-8040 FWP40A14F 17-5114 USM141i

50A 17-8050 FWP50A14F 17-5114 USM141i

63A 17-8063 FWP63A22F 17-5122 US221i

80A 17-8080 FWP80A22F 17-5122 US221i

100A 17-8100 FWP100A22F 17-5122 US221i

2. Combination fuse (suitable for applications with 600V AC and below)

Rated current of fuse Watlow, fuse model Bussman, Watlow bracket model Bussman, bracket model

30A 0808-0325-0030 DFJ30 0808-0326-1530 CH30J1i

40A 0808-0325-0040 DFJ40 0808-0325-3560 CH60J1i

50A 0808-0325-0050 DFJ50 0808-0325-3560 CH60J1i

63A 0808-0325-0060 DFJ60 0808-0325-3560 CH60J1i

80A 0808-0325-0080 DFJ80 0808-0325-7010 J60100-1CR

100A 0808-0325-0100 DFJ100 0808-0325-7010 J60100-1CR

3. EMI filtering requirements (electromagnetic interference suppression)

Mandatory scenario: When the load current is greater than 6A and the frequency is 150-250kHz, an external EMI filter must be used. Watlow verified that the "Tank Filter" can effectively suppress the EMI generated by the SCR power controller and meet the conducted emission limit.

Filter selection: For single-phase 230V (ac), choose Crydom 1F25 or Watlow 14-0019; Choose Crydom 3F20 or Watlow 14-0020 for three-phase 440V (ac); At the same time, a warning is issued that "slot filters may suppress useful communication in the 150-250kHz frequency band (such as baby monitors, medical alarm systems), and there is no safety risk that needs to be verified in advance" 🔶 1-437.

image.png

  • ELAU DB-5 Distribution HW 5104 Servo System
  • Touchstar 10K TS10KCC0CEMP Industrial Touch Panel
  • Beckhoff CX2030-0125 Embedded PC PLC
  • Parker Hannifin HID5CS/S4 HIDRIVE 5A Servo Drive
  • Yaskawa ACE-P300-TH5 Servo Drive with Profibus
  • Omron Sysmac SCY-P0 13E Sequencer Controller
  • Saia Burgess PCD4.M120 PCD4.M12 Central Controller
  • Schneider Electric TSX3722101 Modicon Micro PLC
  • Siemens Micromaster 440 6SE6440-2AD25-5CA1 Inverter
  • SICK DL50-P1123 Distance Sensor
  • Yaskawa SGDH-04AE-OY Servo Driver 200V 400W
  • Cincinnati Milacron 3-542-1203A Circuit Board Module
  • Allen-Bradley 1756-EN2T EtherNet/IP Communication Module
  • OMRON CS1H-CPU66-V1 Programmable Logic Controller
  • ABB SACE TMAX S6N 630 Molded Case Circuit Breaker
  • Weidmuller IE-SW-VL16-16TX 16-Port Ethernet Switch
  • Schneider PowerLogic CM4250 Circuit Monitor
  • Sacmi IDPM IDMP1.A SMC 085.16.982 Control
  • Omron C120-LK202-EV1 Host Link Unit
  • Omron FQ2-S15050F Smart Camera Vision System
  • OMRON CJ1G-CPU44H Programmable Logic Controller
  • SIEMENS KTP600 HMI 6AV6 647-0AD11-3AX0 Touch Panel
  • OMRON CS1G-CPU45H EV1 Programmable Logic Controller
  • Omron C200HG PLC System C200H-ID212 C200H-OC226
  • ROBOSYSTEM IOG4AX-HD-100 IOG-HD Motion Controller
  • Datalogic SG4-S3-080-PP-W Safety Light Curtain
  • Omron NS12-TS01B-V2 Interactive Display
  • Esto Electronic E.CGT-405-42TE PLC Rack
  • Siemens 7ED62 Static Three Phase Counter
  • Oemer QCAVS 100 LBE AC Square Frame Servo Motor
  • Schneider Electric TM262M25MESS8T Motion Controller
  • Eaton Moeller MFD-CP8-ME Power Supply
  • Pro-face PL-5700T1-24VDC Industrial Panel PC
  • GE Fanuc IC693APU300J High Speed Counter
  • Fuji Electric Micrex-F FPU080S PLC Module
  • Automation Direct GS2-45P0 AC Drive
  • Omron 3G3MV-C4015 V1000 Inverter
  • Vacon NXI01055A2T0CSS Industrial Inverter
  • Saia Burgess PCD4.M240 Central Controller Module
  • Yaskawa SGDH-10DE Sigma II Servo Drive
  • Stober EK501USOM140 Servo Motor and Drive
  • SCE M68-2000/4 CNC Controller and I/O Board
  • Omron SP10-PR001-V1 PLC Programming Console Specs
  • VACON NXI01055A2T0CSSA Industrial AC Drive
  • OMRON SYSMAC SCY-P1 Sequencer Controller PLC
  • SEL-2440 DPAC Discrete Programmable Controller
  • BIVIATOR CI3098 CPU Encoder Module Industrial Control Unit
  • Siemens 6FC5371-0AA10-0AA2 SINUMERIK NCU 710.2
  • KOLLMORGEN SERVOSTAR S70601-NA High Performance Servo Drive
  • OMRON C200HW-PCU01 Fastnet PCMCIA LAN Communication Unit
  • ibaFOB-2io-D Two-Channel Fiber Optic Input Output Card
  • ibaFOB-4io-D Four-Channel Fiber Optic Input Output Card
  • ibaFOB-io-S Single-Channel Fiber Optic Input Output Card
  • ibaFOB-4io-S Four-Channel Fiber Optic Input Output Card
  • ibaFOB-4o Four-Channel Fiber Optic Output Interface Card
  • ibaFOB-4i-S Enhanced Four-Channel Fiber Optic Input Card
  • ibaFOB-4i Four-Channel Fiber Optic Input Interface Card
  • ibaFOB-io Fiber Optic Interface Card for iba Systems
  • SM128V VMEbus Interface Card for Industrial Data Acquisition
  • ibaLink-SM-128V-i-2o VMEbus Fiber Optic Interface Board
  • GE Fanuc IC693MDL632 125V DC Input Module 8 Points
  • GE Fanuc IC693MDL241 24V AC/VDC Input Module 16 Points
  • GE Fanuc IC693MDL240 120V AC Input Module 16 Points
  • GE Fanuc IC693MDL231 240V AC Isolated Input Module
  • GE Fanuc IC693MDL230 120V AC Isolated Input Module
  • GE Fanuc IC693MDL654 5/12 VDC 32-Point Input Module
  • GE Fanuc IC693MDL653 24 VDC 32-Point Input Module
  • GE Fanuc IC693MDL648 48 VDC 16-Point Input Module
  • GE Fanuc IC693MDL646 24 VDC 16-Point Input Module
  • GE Fanuc IC693MDL634 24 VDC Input Module 8 Points
  • GE IM 3100 D 1007722 Control Module
  • GE IM0146B Industrial Circuit Board
  • GE IM0059E0-10070 Interface Board
  • GE IM0094C Industrial Control Board
  • GE IC200PNS002-AB VersaMax PROFINET Scanner
  • GE F650BFBF1G0HI Feeder Protection Relay
  • GE TPR5616NRHC Protection Relay
  • GE D6P3KH Digital Protection Relay
  • GE F650BABF2G0HIS Feeder Protection Relay
  • GE F650BADF2G1HIR Feeder Protection Relay
  • GE F650BABF2G1HI6 Digital Bay Controller
  • GE Multilin 745-W2-P1-G1-H-I-A-R-E Transformer Protection Relay
  • GE 100BASE-T Industrial Ethernet Interface
  • GE Multilin 350-E-P1-S1-H-S-E-C-N-2E-D-H Feeder Protection System
  • GE F650MXCF1G1HI6 Bay Controller
  • GE MM300-GEHD2CAB Motor Management Relay
  • GE MMS35-621-1-00 Motor Management System
  • GE 100BASE-T Ethernet Communication Module
  • GE F650MFCF1G1HI6 Feeder Protection Relay
  • GE CK13BA300 Control Module
  • GE W2-P1-G1-H Industrial Control Unit
  • GE PIB315B Power Interface Board
  • GE 343L695VAGIRHC Multi-Function Relay
  • GE Multilin B90N05HKHF8NH6 Bus Differential Protection
  • GE ZX3SC0204N-930 Intelligent Control Module
  • GE PIB504 Process Interface Board
  • GE D20MX Remote Terminal Unit
  • GE T60UJ3HKHF8NH6 Transformer Protection Relay
  • GE ZG3SA02041-58S600X Motor Protection Relay
  • GE ZG3SA02041-58S Motor Protection Relay
  • ABB DSDX 452 L Remote Input Output Module
  • ABB RDCU-02C Drive Control Unit
  • ABB COMMANDER 350 Process Controller
  • ABB Tmax XT4S 250 Molded Case Circuit Breaker
  • DEIF MALLING 8027.90 Industrial Control Unit
  • DEIF DCP2-2410 Power Supply Module
  • DEIF FAS-2N Synchronizer
  • DEIF MALLING 827.54 Processor Module
  • DEIF DU-2/MKIII Display Unit
  • DEIF DRW-2 Reverse Power Relay
  • DEIF 827.4 Power Management Module
  • DEIF 1044220060F Mains Measurement Module
  • DEIF 1044220190G Remote Display Module
  • DEIF 1044220140C AGC 200 Display Module
  • DEIF BRW-1-NB Remote Display Unit
  • DEIF MALLING 827.52 Industrial Control Unit for Automation Systems
  • DEIF BRW-2 Industrial Relay Module for Control Systems
  • DEIF 1044220080D Power System Control Module Industrial Automation
  • DEIF 1044220100F Controller Module for Generator Control Systems
  • DEIF DU-300 Voltage Monitoring Relay Industrial Protection Unit
  • DEIF 1044220060F I/O Extension Module
  • DEIF 1044220150C Interface Module
  • DEIF GCU 100 Engine Control Unit
  • DEIF XDI144-DUAL Marine Indicator
  • DEIF 827.41 Multi-line 2 Processor Module
  • DEIF AGC 146 Automatic Genset Controller
  • DEIF 1044220080E MDR-2 Display Module
  • DEIF MDR-2 Multifunctional Digital Relay