Westinghouse DS/DSL series low-voltage power circuit breakers

F: | Au:FAN | DA:2025-11-13 | 667 Br: | 🔊 点击朗读正文 ❚❚ | Share:

Main circuit wiring: The tightening torque meets the requirements (copper bars/cables need to be crimped to the terminals) to avoid loosening and heating; The cross-sectional area of the three-phase wires is consistent, and the phase correspondence is correct.

Control circuit wiring: The electric operation type needs to be connected to a compliant control power supply (AC120/240V or DC48/125/250V), and the connection between the trip unit and the actuator should be firm with correct polarity (otherwise the protection function will fail).

Grounding requirements: The circuit breaker frame must be reliably grounded with a grounding resistance of ≤ 4 Ω to avoid electric shock caused by leakage.

3. Operation and operational safety

Working position operation:

Remove position: only used for maintenance or replacement. The energy storage spring must be released first, and all power sources must be disconnected. It is forbidden to remove it while it is still live.

Disconnect position: Both the main and auxiliary contacts are disconnected, which can be locked to prevent misoperation and is used for isolation and maintenance.

Test position (TEST): The auxiliary contact is connected, which can test the closing/tripping action and tripping function. The main circuit is not powered.

CONNECT: Normal operating position, it is necessary to confirm that the mechanical stop is in place, the interlocking device is locked, and it is prohibited to switch positions in the closed state.

Energy storage and closing operation:

Manual energy storage: DS-206 and other models require a single stroke downward pull on the energy storage handle, while DS-416 and above require multiple presses on the ratchet wheel. After energy storage is completed, there will be a "click" sound and the spring energy storage indicator light will light up.

Electric energy storage: After connecting to the control power supply, the circuit breaker will automatically store energy in the test/connection position. In case of energy storage failure, emergency manual energy storage can be used.

Closing taboos: Do not close with load; Do not repeatedly close the circuit when the short circuit fault has not been resolved; Do not close the circuit with current exceeding the nameplate.

Fault handling safety:

Troubleshooting after tripping: Overload tripping requires reducing the load, short-circuit tripping requires troubleshooting for line faults, grounding faults require checking the grounding circuit, and DSL series requires confirming whether the current limiting element is blown.

Emergency stop: In the event of a serious malfunction, emergency stop can be achieved through the panel trip button or remote trip signal, and forced locking and closing are prohibited.

4. Environment and Protection Safety

Operating environment: It is necessary to maintain dryness, cleanliness, good ventilation, avoid dust, oil mist, corrosive gases (such as chlorine and ammonia), and prevent contact oxidation and insulation aging.

Temperature control: When the ambient temperature exceeds 40 ℃, it is necessary to reduce the capacity (reduce the capacity by 10% for every 10 ℃ increase), and avoid direct sunlight or proximity to heat sources.

Moisture prevention measures: Insulation inspection should be strengthened in humid environments, and insulation resistance should be measured regularly (main circuit ≥ 1M Ω, control circuit ≥ 2M Ω).

image.png

Complete operation process (installation → debugging → maintenance)

1. Installation process (drawer style as an example)

Guide rail preparation: Open the circuit breaker cabinet door, unfold the built-in guide rail to a horizontal position, and ensure that the guide rail is not deformed or stuck.

Remove transportation fixing: Remove the transportation bracket and plastic protective cover on the circuit breaker, and check that the energy storage spring is not preloaded (released during transportation).

Push in the circuit breaker: Align the circuit breaker with the guide rail, slowly push it into the extraction position, insert the joystick and rotate it clockwise to switch to the disconnection position, test position, and connection position in sequence. Each position needs to be confirmed to be mechanically locked in place (with a "click" sound).

Wiring operation:

Main circuit: Connect the incoming and outgoing copper bars according to the phase, tighten the bolts (refer to the equipment manual for torque), and check the balance of the three-phase resistance.

Control circuit: Connect control power supply, remote closing/tripping signal, tripping unit power supply, check wiring diagram to avoid reverse polarity connection.

Grounding: Connect the grounding terminal of the circuit breaker frame reliably to the cabinet grounding bar.

Insulation test: Use a 500V megohmmeter to measure the insulation resistance of the main circuit. A resistance of ≥ 1M Ω is considered qualified, otherwise moisture or wiring faults need to be investigated.

2. Debugging process

Energy storage testing:

Manual energy storage: Operate the energy storage handle, confirm that the energy storage is completed, and the spring energy storage indicator light will turn on, and the closing mechanism can operate normally.

  • Valmet BIU4 M851221 Binary Input Module
  • Valmet PMB 1S CPU SCU Rack Module
  • Valmet A413248 Controller Module
  • Valmet PDP601 Distributed Processing Unit
  • VALMET M851004 M2 CPU Printed Circuit Board Module
  • Metso Valmet A413045 Ver.05 CPU Module
  • Valmet A413181 Ver.05 PLU1 Board
  • Lyngso Valmet ATB16 Controller Board
  • VALMET AIU 16 Analog Input Unit 545100-3A/3B
  • VALMET PUD 10 B Power Supply PCB Rack Module
  • Valmet MS-50V/120V Bearing Unit
  • Valmet PDP603 Distributed Processing Unit – DPU Module
  • Valmet A413110 TIU Board – Terminal Interface Unit
  • Valmet S420154 I/O Backplane PCB – Printed Circuit Board
  • Valmet A413173 Industrial Control Module
  • Valmet A413044 CPU Module
  • Valmet A4IU1 Analog I/O Module
  • Valmet A413325 IPU Power Unit – PLC Module
  • Valmet M851002 CPU Module – Central Processing Unit
  • Valmet PUD10B Power Supply Board
  • Valmet K00990 Master CPU Electronic Assy
  • Valmet Metso IOP345 Input Module
  • Metso Automation T545215 Board
  • Valmet Metso IOP304 Input Module
  • Valmet 542844-6A SCU Module
  • Metso A413043 Ver.11 Valmet CPU Module
  • Valmet Automation BIU 8A Input Module
  • Metso A413044 Ver05 Valmet CPU Module
  • VALMET 542821-5A Control System Rack Module
  • Metso A413005 Ver.04 Valmet CPU Module
  • Valmet M851207 AIU16 Card
  • Valmet BIU8 Binary Input Unit
  • VALMET 547070-2B CPU Printed Circuit Board Module
  • Valmet Automation A413325 Power Module
  • VALMET AUTOMATION A413135 AOU4 Module
  • VALMET ACU A413165 Model 9 Analog Controller
  • VALMET AUTOMATION A413511-02 Slot Rack with I/O Backplane
  • Valmet A413148 BIE 4 Rev 08 Board
  • Valmet ATB16-4 Controller Board
  • Neles Automation BOR82 A413292 Processor Module
  • Valmet A413015 NCU Module – Network Control Unit
  • Valmet AIU 16 Analog Input Unit – M8512071
  • Metso Valmet A413091 GDU Board
  • Valmet M851565 Damatic Main Keyboard
  • Metso A413082 CPU Module
  • Valmet A403037 GDC – Graphics Display Controller
  • Valmet A413076 FBC Board
  • Valmet A413015 NCU Module – Network Control Unit
  • Valmet A413082 CPU Module
  • VALMET AUTOMATION A413620 Fieldbus Repeater
  • Valmet Metso IOP341R Positioner Module
  • Metso A413082 Ver.04 CPU Module
  • Valmet Metso MCA FT250/10 10 Inch Sensor
  • Valmet N0542 ABMB Printed Circuit Board
  • Valmet A413000 Ver.07 CPU Module
  • Valmet A413061 Ver.05 DMU Module
  • Valmet M851241 M1 BCU Binary Input Module
  • Valmet Automation NCU A413015 Circuit Board
  • Valmet A413046 Ver.06 CPU Module
  • Valmet A651B001 Panel Mount Keyboard
  • Valmet IQ Scanner A418080R Basis Weight Detector Head
  • Metso Valmet A413370 ESU Ethernet SCSI Unit
  • Valmet A413340 FPU Power Supply Unit
  • Valmet SKF GE 400/600 Spherical Plain Bearing
  • Valmet SCU PCB Card 542844-7B – System Control Unit
  • Valmet A413075 FBU Fieldbus Controller Module
  • Valmet A413171 PIC Card Binary Output
  • Valmet A413002 Ver.05 CPU
  • Valmet ABMB PCB Card – Industrial Control Board
  • Valmet PMB 2R 542821-4A PCB Card
  • Metso Valmet A413001 CPU Module
  • Metso Valmet A413050 RSU 6 Serial Controller Unit
  • Valmet ABMB MT241 Input Mother Board
  • Valmet DAMATIC M851565 Keyboard
  • Valmet A413075 Ver05 FBC Board
  • VALMET K14891 FLEXI-U Operating Terminal
  • VALMET AUTOMATION MKB2 DAMATIC Keyboard
  • Valmet Metso Consistency Transmitter Smart Pulp M1 RL Blade
  • VALMET AUTOMATION A413230 ECU Module
  • Beckhoff EP9224-0037 - 4-Channel Power Distribution Box EtherCAT
  • Beckhoff CX2900-0026 - Solid State Flash Memory Card 20GB CFast
  • Beckhoff BK7500 - SERCOS Interface Fieldbus Bus Coupler Terminal
  • Beckhoff Ep2328-0002 - 4-Channel Input 4-Channel Output EtherCAT Box IP67
  • Beckhoff CX1020-0111 - Controller Kit Combo Interface Modules
  • B&R X20AI2237 - X20 System Analog Input Interface Module
  • Beckhoff CP2221-0010 - Multi-Touch Built-In Panel PC Touchscreen
  • Beckhoff CX1500-M310 - Fieldbus Master Interface Module 24V
  • Beckhoff CX2100-0904 - Power Charging Module Smart UPS Extension
  • Beckhoff CP3918-0000 - Multi-Touch Control Panel 18.5-Inch Monitor
  • Beckhoff CP2915-0000 - 15-Inch Multi-Touch Built-In Control Panel
  • Beckhoff CP7037-1027 - HMI Industrial Control Panel Built-In PC
  • Beckhoff EL3152 - 2-Channel Analog Input Terminal 4-20mA EtherCAT
  • Beckhoff CP6607-0000-0020 - 5.7-Inch Built-In Panel PC HMI Touch
  • Beckhoff EJ1809-0000 - 16-Channel Digital Input Pluggable Signal Level Terminal
  • Beckhoff AM8563-0N10-0000 - Synchronous Servo Motor
  • Beckhoff AX2006-S60600-520 - Compact Servo Drive Inverter
  • Beckhoff AM8053-0K20-0000 - Servo Motor with Planetary Gearbox AG3210
  • Beckhoff AM8042-0FH1-0000 - Synchronous Servo Motor
  • Rexroth R911338600 - IndraControl V HMI Terminal Beckhoff PCI Card FC9002
  • Beckhoff AX5125-0000 - 3 Phase Industrial Servo Drive 1000Hz
  • Beckhoff EP2328-0002 - 4-Channel Digital Input 4-Channel Output EtherCAT Box
  • B&R 7CP476-02 - System 2005 RTD CPU Module 3IF681.86 Interface
  • Beckhoff AX8620-0000-0000 - Power Supply Module Axis Drive System
  • Beckhoff CX1010-0111 - PLC Module CPU Controller 24V
  • Beckhoff AM8043-0H10-0000 - Synchronous Servo Motor
  • Beckhoff C6240-1009 - Control Cabinet Industrial PC Mainframe
  • Beckhoff BX8000-0000 - Bus Terminal Controller HW 4.4 Standalone
  • Beckhoff CP7721-1089-0020 - 12.1-Inch Touch Screen HMI Panel PC
  • Beckhoff CP7132-0001 - Industrial Built-In Panel PC Screen
  • Beckhoff CP2912-0010 - Multi-Touch Built-In Control Panel Display
  • Beckhoff CP2915-0000 - 15-Inch Multi-Touch Built-In Control Panel
  • Beckhoff AM8532-1EN0-0000 - Synchronous Servo Motor
  • Beckhoff AX5203-0000 - 2-Channel Digital Compact Servo Drive
  • Beckhoff CX2020-0141 - Embedded PC Core CPU Module
  • Beckhoff CP6832-0002-0010 - Built-In Industrial Control Panel Display
  • Beckhoff CX5020-0112 - Embedded PC CPU Control Module
  • Beckhoff CX5140-0175 - 4GB Embedded PC CPU Unit 24V
  • Beckhoff EL3681-0030 - Digital Multimeter Calibration Terminal EtherCAT
  • Beckhoff CP7201-1000-0000 - Industrial PC Touch Screen HMI Monitor
  • Beckhoff CP7232-1001-0000 - Industrial Panel PC Touch Screen
  • Beckhoff C6930-1032-0040 - Control Cabinet Industrial PC System
  • Beckhoff AX5125-0000 - 3 Phase Industrial Servo Drive 1000Hz
  • Beckhoff CP3916-1424-0000 - Multi-Touch Built-In Control Panel
  • B&R 1900071142 - Lemoine Fieldbus Communication Interface Module
  • Beckhoff EL2872 - 16-Channel Ribbon Cable Digital Output Terminal
  • Beckhoff CX2030-0120 - Embedded PC CPU Base Module Controller
  • Beckhoff CP3919-0000 - 19-Inch Multi-Touch Control Panel Touchscreen
  • Beckhoff AX5101-0000-0202 - Servo Driver Compact Intelligent Drive 180V