How to order Emerson DeltaV Ethernet I/O Card (EIOC)?

来源: | 作者:FAN | 发布时间 :2025-08-23 | 623 次浏览: | 🔊 Click to read aloud ❚❚ | Share:


How to order Emerson DeltaV Ethernet I/O Card (EIOC)?

Core positioning and core advantages

DeltaV Ethernet I/O Card (EIOC) is an embedded data server designed specifically for DeltaV systems to access external Ethernet device networks. It supports multiple industrial Ethernet protocols and can directly communicate with third-party Ethernet devices (such as PLCs, motor control centers, intelligent electronic devices, etc.) to achieve data acquisition and device control. Its core advantages can be summarized as seven key features:

Direct connection to Ethernet device network: No intermediate gateway is required, and external Ethernet devices can be directly connected through Modbus TCP, EtherNet/IP, IEC 61850 MMS, OPC UA client, and EtherNet/IP control tag integration protocol. It supports device monitoring and control, operates independently of DeltaV controller, and reduces system complexity.


High capacity and scalability: The license mode based on the number of device connections adapts to different needs, and the data access capability varies with the protocol: under the Modbus TCP/Ethernet/IP/IEC 61850 MMS protocol, up to 256 devices and 32000 signals can be accessed; Under the OPC UA client protocol, up to 64 servers and 30000 real-time signals can be accessed; Under the EtherNet/IP control tag integration protocol, up to 256 devices and 2000 tags (10 signals per tag) can be connected to meet the requirements of large-scale industrial scenarios.

Complete monitoring and control functions: The accessed data can be processed in the built-in control module of EIOC, supporting alarm generation, historical data collection, and operator interface display. The functions are consistent with traditional DeltaV controllers; Supports discrete control and limited PID control function blocks, without the need to allocate them to DeltaV controllers, and can directly control Ethernet devices such as motors, switchgear, and frequency converters.

Powerful processing capability: A single EIOC can run up to 2000 control modules, and the system supports up to 60 EIOCs directly connected to the DeltaV control network, flexibly achieving network isolation and adapting to complex factory network architectures.

Flexible network configuration: Users can manually configure the IP address of Ethernet device networks to adapt to various factory network solutions; The simplex design requires EIOC to be on the same IP subnet as the device, while the redundant design requires EIOC primary and backup ports to be on different subnets (following best engineering practices); Support for Parallel Redundancy Protocol (PRP), seamless switching in case of redundant network failure, zero recovery time, and elimination of single point of failure.


Usability design: Native integration with DeltaV system, supporting 5 protocol choices (only 1 at a time, corresponding license required), EIOC and driver updates included in DeltaV system updates; The configuration is completely completed in DeltaV Explorer and Control Studio, consistent with the traditional I/O signal configuration process. The data can be accessed through the DeltaV Live/Operate interface and historical database, reducing the cost of operation and maintenance learning.

Modular redundancy design: The dual level carrier integrates redundant power input terminals and redundant Ethernet isolation ports. Adding one EIOC can achieve redundant configuration, and the system automatically identifies redundant pairs; Redundant Ethernet ports isolate communication between the DeltaV control network and Ethernet device networks, supporting manual triggering of switches in the DeltaV diagnostic browser to ensure high system availability.

Core components and functional details of the product

(1) Core hardware components

Component Name Function Description Key Features

EIOC card embedded data server, realizing communication with Ethernet devices and DeltaV control network. Single card supports 2000 control modules, input power 24V DC ± 10% (single redundancy 325mA max, dual redundancy 575mA max), heat consumption single redundancy 7W max, dual redundancy 13W max, with power/error/main/backup status/communication status LED indicator lights

Double horizontal carrier DIN rail horizontal installation, supporting 1 (single redundancy) or 2 (double redundancy) EIOC cards and auxiliary components, providing redundant 24V DC power interface (1A max) and redundant Ethernet isolation port (copper cable 10/100BASE-TX, RJ45100m), including universal carrier protection cover

Ethernet isolation port enables physical isolation between DeltaV control network and Ethernet device network, supporting only copper twisted pair cables and connected through RJ45 interface to ensure network security and signal stability

The power plug provides 24V DC power input for the carrier and EIOC to adapt to redundant power configuration, ensuring reliable power supply


(2) Support protocols and key functions

1. Core Industrial Ethernet Protocol

Protocol type adaptation equipment key function data access capability

Modbus TCP PLC、 Motor Control Centers (MCC), analyzers, and other Modbus TCP devices (or Modbus serial devices connected through gateways) use EIOC as Modbus clients to read coil/discrete input/input register/hold register data and write coil/hold register data; Only supports MODICON (PLC) addressing, register addresses have range limitations (such as coil 1-9999), 256 devices, 32000 signals

EtherNet/IP PLC、 Intelligent field devices (IFDs), frequency converters, MCCs, etc. support implicit (Class 1) and explicit (Class 3) communication and are compatible with Class 1/3 I/O adapters; Support Class 3 PCCC and UCMM (with Logix tags) message classes; Redundant communication requires special configuration (refer to the DeltaV System Planning Guide) with 256 devices and 32000 signals

IEC 61850 MMS motor protection relays, motor starters MCC、 Intelligent electronic devices (IEDs) such as switchgear use EIOC as MMS clients to read and write real-time signals; Not supporting historical data reading and GOOSE application. 256 devices, 32000 signals

OPC UA client OPC UA server (third-party device or system) follows OPC UA 1.03 standard, supports Data Access (DA) protocol, and only processes real-time data; Supports 128/256 bit encryption, message signing, and digital certificates (self signing/CA authentication). 64 servers and 30000 signals can be configured for online/offline browsing through NodeSet files

EtherNet/IP control tag integration ControlLogix, CompactLogix and other tag based PLCs access data through tag names based on EtherNet/IP Class 3 messages (without register mapping); Support string signal reading and array reading/writing (up to 64 elements per array, up to 100 arrays per EIOC); Only supports controller scope labels, does not support program labels. 256 devices, 2000 labels (10 signals per label, for a total of 20000 signals)

2. Parallel Redundancy Protocol (PRP)

Function: Ethernet redundancy protocol, primary and backup network ports communicate simultaneously, devices receive the same data through dual paths, zero switching time in case of failure, eliminating redundant network single point failures, suitable for high availability demand scenarios (such as IEC 61850 MMS electrical monitoring).

Usage conditions: The device must have native support for PRP; Non PRP devices need to be connected through RedBox to avoid abnormal diagnostic status; PRP is independent of application protocols and can be used in conjunction with all EIOC supported protocols without the need for additional licenses.


(3) Control module and functional block limitations

Control module capability: A single EIOC can run up to 2000 control modules, supporting basic functional blocks such as alarm detection, AI/AO/DI/DO tag I/O, logical operations, mathematical calculations, timers/counters, etc. The module execution rate can be selected from 100ms-60s.

Function block restrictions:

Supports a limited number of specific functional blocks: 256 DC/EDC/DCC (motor control), 26 PID (analog control), 16 SEQ (stepper), 16 STD (state transition diagram).

Unsupported functions: Batch control, SFC (Sequential Function Diagram), PLM (Process Logic Manager), equipment module, complex control requires PK controller or VIM2 card.

Hardware specifications and compatibility

(1) General Environment and Hardware Specifications

1. General environmental specifications (all components)

Category parameter details

Working temperature -40~70 ° C (-40~158 ° F), long-term high-temperature operation will shorten the service life

Storage temperature -40~85 ° C (-40~185 ° F)

Relative humidity 5%~95% (no condensation)

Protection level IP20

Pollutant level ISA-S71.04-1985 G3 level (with conformal coating)

Anti impact 10g half sine wave (continuous for 11ms)

Vibration 2~13.2Hz (1mm peak to peak), 13.2~150Hz (0.7g)

2. Core hardware dimensions and electrical parameters

Component size/electrical parameters

EIOC card height 13.7cm (5.39 inches), depth 17.4cm (6.85 inches), width 2.9cm; input power supply 24V DC ± 10%, built-in non replaceable fuse

Dual level carrier compatible with horizontal T-shaped DIN rail, Ethernet isolation port spacing of 6.1cm (2.41 inches), protective cover compatible with redundant slots

Ethernet isolation port supports 10/100BASE-TX, RJ45 interface, transmission distance of 100m


(2) System compatibility and certification

Compatibility requirements:

Software version: Modbus TCP/Ethernet/IP/IEC 61850 MMS requires DeltaV v13.3.1 or higher; OPC UA client/EtherNet/IP control tag integration/PRP requires v14. LTS or above.

Controller adaptation: Supports communication with M-series and S-series controllers, and EIOC control module parameters can be called by the controller through external references; Excluding the limit on the number of controller nodes, the system has a maximum of 60 EIOCs.

Network node limitation: The total number of EIOC, remote I/O nodes, CHARM I/O cards (CIOC), and wireless I/O cards (WIOC) shall not exceed 300.

Core certification:

Security certification: CE(EMC EN 61326-1)、FM(3600/3611)、CSA(C22.2 No.213-M1987/1010-1)、ATEX(94/9/EC、EN60079-0/15)、IECEx(IEC60079-0/15)、 Classification certification (IACS E10, ABS, DNV-GL).

Security level: Achilles level 2 (v13.3.1, v14. FP1, except for PRP communication).

Dangerous area: FM/cFM Class I Division 2 (Groups A-D, T4); ATEX/IECEx Zone 2(Ex nA IIC T4 Gc)。

Ordering Information and Preconditions

(1) Core Product Order List (Some Key Models)

Product Category Description Model

EIOC component single redundant EIOC component (including 1 EIOC, dual horizontal carrier, protective cover, 2 Ethernet isolation ports, 2 power plugs) SE4100

Dual redundant EIOC components (including 2 EIOCs, dual horizontal carriers, 2 Ethernet isolation ports, 2 power plugs) SE4101

Protocol License Modbus TCP Interface License VE4103

EtherNet/IP Control Label Integration License VE4104

EtherNet/IP interface license VE4105

OPC UA Client License VE4106

IEC 61850 MMS interface license VE4107

Equipment License EIOC/PK Controller Physical Equipment License (nn is the number of devices) VE4109Sxxx

Spare parts EIOC card KL2001X1-BD1

Ethernet isolation port (copper cable) KL1604X1-BA1

Double level carrier KL4104X1-BA1

Universal carrier protective cover SE6106

(2) Pre requirements

Installation in hazardous areas must follow the "DeltaV S Series Class 1 Division 2 Installation Guide" (12P5402) and the "DeltaV S Series Zone 2 Installation Guide" (12P5404).

Suggest configuring an industrial network firewall to restrict device and protocol level communication through deep packet inspection, in order to enhance network security.

DeltaV Simulate v14 only supports virtual EIOC (vEIOC) and does not support physical EIOC.

The VE4109Sxxx license is system level and can be assigned to EIOC or PK controllers. The number of licenses can be stacked (no upgrade license, additional license extension devices are required).


  • Siemens 6SL3210-1SE21-8UA0 PM340 Power Module SINAMICS Drive System
  • Yaskawa JANCD-XCP01C-1 Servo Control Board with JANCD-XIF04-1 Network Interface
  • BRISTOL 396879-01-2 C Wave Micro PLC CPU with Ethernet Industrial Controller
  • OMRON SGDH-10DE-OY Servo Drive High Precision Industrial Motion Control Amplifier
  • OMRON FQM1-MMA22 PLC High Performance Motion Controller Module
  • Schneider PowerLogic P5F30 Protection Relay
  • ABB DSPC53 57310256BA/2 Processor PCB
  • ABB Jokab 2TLJ020070R1700 Eden Safety Sensor
  • Lenze HMI EL 105C 3351-1 2 Control Panel
  • Pilz PSEN op4-s-30-060/1 Safety Light Curtain Specs
  • Vacon NXI01055A2T0CSSA1A3AK00C6 AC Drive
  • Square D PowerLogic CM4250 Circuit Monitor
  • Siemens CPU314C-2PTP Simatic S7-300 PLC
  • Eaton E84BAN Communication Interface Module
  • Prosoft MVI56 PDP-MV1 Profibus Master Module
  • Kongsberg MEI 8100276 Multi I/O Interface Module Marine Control System
  • Kongsberg MD 22 TN Display Module Marine Control Display Unit
  • Kongsberg MSI 8100222 Multi Signal Interface Module Marine Control System
  • Kongsberg RDO-16 8100155 Digital Output Module Marine Control System
  • Kongsberg RAO-8 8100153 Analog Output Module Marine Control System
  • Kongsberg C2 8100182 Controller Module
  • Kongsberg dPSC 8100183 Digital Process Controller
  • Kongsberg SPBUS-HUB 600309 Process Bus Hub
  • Kongsberg Simrad BP413R 37960580 A PCB Card
  • Kongsberg RAi-10tc 8100161 Remote Analog Input
  • Kongsberg NL-290 KM-F Navigation Light Panel
  • Kongsberg RAI-16xe Remote Analog Input Module
  • Kongsberg dPSC 8100183 Dynamic Positioning Control Panel
  • Kongsberg NK-210 NU02 Control Panel
  • Kongsberg RAIC400 Remote Analog I/O Controller
  • Kongsberg Simrad SJS-01/02 Sonar Sensor Marine Detection System
  • Kongsberg RAo-8 Analog Output Module Marine Automation Control Module
  • Kongsberg MP 530 Operator Panel Unit Marine Control Interface System
  • Kongsberg PSO-P 8100334 Power Supply Unit Marine Automation Power Module
  • Kongsberg dPSC 8100183 Dynamic Positioning Controller Marine Control System
  • Kongsberg MP 8200 Processor Module
  • Kongsberg MP 8300 Multi Processor Board
  • Kongsberg MCU8625 Marine Control Unit
  • Kongsberg MP 5810 Multi Processor Board
  • Kongsberg DSU 001 Dual Slot Unit
  • Kongsberg RCU 510 Remote Control Unit
  • Kongsberg BS610 Battery Supply Unit
  • Kongsberg M410-10 Alarm Monitoring Panel
  • Kongsberg HMS 100 Hull Monitoring System
  • Honeywell TCF901 Gas Detector
  • Honeywell 9938R Relay Output Module Industrial Control Switching Module
  • Honeywell XL1000C1000 Building Automation Controller HVAC Control System
  • Honeywell S0762970 I/O Interface Module Industrial Automation Signal Module
  • Honeywell RM7850 Burner Control Module Industrial Flame Safeguard Controller
  • Honeywell IPC1100 Industrial Panel Computer Automation Control HMI System
  • Honeywell TDID72 Digital Input Module
  • Honeywell TCNT01 Control Processor Interface
  • Honeywell C300 Controller Process Automation
  • Honeywell 51304337-250 Redundancy Cable Assembly
  • Honeywell PAL 2053 Programmable Array Logic Board
  • Honeywell IOC2053 Input Output Card
  • Honeywell PAIH03 Analog Input Module
  • Honeywell IPC 621 Industrial Computer
  • Honeywell 05701-A-0301 Process Control Card
  • Honeywell 10302/2/1 Power Supply Module
  • Honeywell SPXCDALMTX4 Gas Detector Module Industrial Safety Monitoring Device
  • Honeywell PHAI01 Analog Input Module Industrial Automation Input Module
  • Honeywell 63AP3070 Pressure Transmitter Industrial Measurement Module
  • Honeywell P522AC Analog Controller Module Industrial Control System Component
  • Honeywell K2LCN-4 ControlNet Interface Module Industrial Communication Module
  • Honeywell M6184D1035 Proportioning Actuator
  • Honeywell PCF901 Pulse Control Interface Module
  • Honeywell 05701-A-0302 Gas Detection Control Card
  • Honeywell S0762970 Gas Chromatograph Replacement Part
  • Honeywell 80363975-150 Experion PKS Cable Assembly
  • Honeywell T901-P Terminal Block Assembly
  • Honeywell 8C-PAINA1 Analog Input Module
  • HIMA B9361 Rack Power Supply Assembly
  • HIMA H51q-HRS B5233-2 System Rack Module
  • HIMA B9302 8-Channel Digital Output Module
  • HIMA K7214 996721402 Control Module Industrial Automation Safety System Module
  • HIMA HIMatrix F35 982200416 Safety Controller Compact SIL 3 Automation System
  • Phoenix QUINT-DIODE/12-24DC/2x20/1x40 2320157 Redundancy Module Power Distribution Unit
  • HIMA HIMax X-FAN1503 Cooling Module Industrial Control Cabinet Cooling System
  • HIMA PS1000/230010 982200080 Power Supply Module Industrial Safety System Power Unit
  • HIMA F3330 Power Supply Module
  • HIMA F60DIO24/1601 Digital I/O Module
  • HIMA F60DO801 Digital Output Module
  • HIMA H7201 Safety Controller Module
  • HIMA ELOP II 892042336 Engineering Tool
  • HIMA H7202 Communication Interface Module
  • HIMA F3331 Digital Output Module
  • HIMA F3236 Digital Input Module
  • HIMA F6217 Digital Output Module
  • HIMA F7133 Power Distribution Module
  • HIMA Alarm & Event OPC Server 892042420 V3.07.08 Alarm Data Integration Platform
  • HIMA Alarm & Event OPC Server 892042420 V3.08.09 Industrial Alarm Communication System
  • HIMA HIMatrix SILworX 504110 895400001 Safety Engineering and Configuration Platform
  • HIMA HIMatrix SILworX 504111 895210001 Engineering and Safety Configuration Software
  • HIMA OPC DA Server 892042400 V3.56.4 Industrial Data Communication Platform
  • HIMA OPC Alarm & Event Server 892042420 v4.1.3
  • HIMA OPC Alarm & Event Server 892042420 v4.0.5
  • Phoenix Contact QUINT-DIODE 2320157 Redundancy Module
  • Phoenix Contact QUINT-PS/1AC/24DC/40 2866789
  • Moore Industries SIY/PRG/4-20MA/10-42DC PC-Programmable Signal Isolator Specs
  • Motorola 01-W3394F-03F VMEbus Processor Module
  • Motorola AP-4 256 MByte Processor Module 01-W3839F-07A
  • Motorola MVME2432 VMEbus Processor Module
  • Motorola PCE I 01-W3839F-07A Processor Module
  • Motorola PCE I HPR431 Power Converter Module
  • Motorola AP-4 01-W3394F-03G Processor Module
  • Emerson 01-W3878F-02D Control Module
  • GE 369-HI-R-0-0-0-0-E Motor Management Relay
  • GUTOR OP2446/640-1017 Main Processor Board
  • Honeywell FC-R/PB2/N/12 I/O Module
  • Honeywell HCIX07-TW-ND-N Valve Positioner
  • Honeywell PCN01 Process Controller
  • Honeywell TAMR04 Actuator Control Module
  • Honeywell 51404127-250 I/O Module
  • Honeywell TN3801 Temperature Transmitter
  • ALSTOM SKE11BF8003BCH Check Synchronizing Relay
  • ALSTOM VAGM22AF171G High-Speed Auxiliary Relay
  • ALSTOM VAGM22AF71C Auxiliary Relay
  • ALSTOM MX3EG1A Generator Protection Unit
  • ALSTOM P743316A6M0510 Busbar Protection Relay
  • ALSTOM P14136A6M0440J Motor Generator
  • ALSTOM 3EST000214-134 Protection Relay
  • ALSTOM C264LB1I691000 CPU Module
  • ALSTOM FV223-M2 Variable Frequency Drive
  • ALSTOM MC15-M2 Motor Control Unit
  • ALSTOM LGPG11101R551 Protection Relay
  • ALSTOM 3BEC0067C Specialized Control Module
  • ALSTOM PIB310 Input Output Processing Board