Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

ABB PCS6000 SYSTEM DRIVES

来源: | 作者:FAN | 发布时间 :2025-05-24 | 759 次浏览: | Share:

ABB PCS6000 SYSTEM DRIVES

Security information

Safety standards and labels: Following ANSI, ISO, EN and other standards, the equipment is labeled with safety labels such as danger, warning, and caution to alert potential risks, such as the impact of high voltage, high temperature, and magnetic fields on pacemakers. The label instructions must be strictly followed.

Safe operating procedures

Seven step safety guidelines: including risk assessment, power-off locking, voltage detection, grounding short circuit, protection of adjacent live parts, etc., to ensure operational safety.

Main circuit breaker (MCB) requirements: The MCB must be directly controlled by a frequency converter, and the breaking time must comply with specifications (protection trip ≤ 75ms, safety trip ≤ 500ms), and equipped with independent trip coils or undervoltage coils.

Residual risks and maintenance: There are residual risks such as electromagnetic interference, accidental movement, and contact voltage, and it is necessary to regularly check the MCB trip circuit. During maintenance, ensure that the power is turned off and personal protective equipment is used.

product description

Application and Configuration: Suitable for large wind turbines and tidal applications, with two configurations: 1CL (single conversion line) and 2CL (dual conversion line, supporting restricted mode), supporting back-to-back, face-to-face, and series layouts.


Modular components

Power Unit (POU): consisting of three 3-level NPC phase bridge arms and IGCT, controlled by the main circuit interface board.

DC Link Unit (DLU): Integrated Neutral Connection Module (NCM), Voltage Limiting Module (VLM), dv/dt Filtering Module (VFM), Grounding Isolator, and Generator Isolation Switch Module (GDM), etc.

Grid Circuit Breaker Unit (GBU): includes a circuit breaker and a three position switch, used for grid side connection and grounding.

Other units include Water Cooling Unit (WCU), Filter Unit (FIU), Braking Resistance Unit (BRU), and Converter Control Unit (CCU), which are responsible for heat dissipation, harmonic filtering, energy dissipation, and system control, respectively.

Cabinet design: Using modular galvanized steel frame, protection level IP54, electromagnetic compatibility (EMC) achieved through sealed design, standard color RAL 7035, supporting crane or forklift handling.

Transportation, storage, and disposal

Transportation requirements

Packaging method: Wooden pallets and polyethylene film are used for land transportation, while wooden boxes and aluminum foil moisture-proof film are used for sea transportation. Symbols such as "fragile" and "keep dry" should be marked.

Loading and unloading precautions: Use a crane or forklift, keep the equipment upright, avoid tilting at an angle exceeding 30 °, and do not stand on top of the cabinet.

Storage conditions: The original packaging can be stored for 1 year in a dry, dust-proof, and corrosion-resistant environment, following the IEC 60721-3-1 standard. Spare parts need to be stored anti-static.

Disposal requirements: Components such as batteries, capacitors, and circuit boards must be disposed of in accordance with local regulations to avoid environmental pollution.

installation guide

Mechanical installation: It needs to be carried out in a dust-free environment. The cabinet is fixed to the floor with M16 bolts. After installation, check for paint damage and repair to ensure that there are no foreign objects left.

electrical installation

EMC zoning: divided into five areas: power grid, transformer, power section, control cabinet, and generator. Cables need to be isolated and laid according to categories (Class 1-4), with spacing in accordance with IEC 61000-5-2.

Cable requirements: Power cables must be shielded and meet the IEC 60228 standard; The distance between the control cable and the power cable should be ≥ 30cm, and they should be laid vertically when crossing.

Grounding system: The protective grounding (PE) is separated from the functional grounding (FE), and the cross-sectional area of the grounding conductor is ≥ 95mm ² to ensure safe discharge of fault current.


Debugging and operation

Debugging preparation: It needs to be carried out by ABB certified personnel to inspect mechanical installation, electrical connections, grounding, cooling systems, etc., complete insulation testing and parameter settings, and sign the debugging report.

Operation interface: Local control devices include emergency stop buttons, key switches, status indicator lights, and debugging ports, supporting remote control through fieldbus.

Startup process: The anti dew startup sequence (heating control unit and water circulation) needs to be completed, and the auxiliary power supply, cooling system, door lock status, and circuit breaker position need to be checked to ensure that there are no fault alarms.

Emergency operation: Pressing the emergency stop button will disconnect the main power supply, discharge the DC link, and manually reset and clear the fault before restarting.


Maintenance and troubleshooting

Preventive maintenance: including visual inspection (dust, signs of overheating), cleaning, performance testing, and component replacement, following the PCS6000 Preventive Maintenance Plan (3BHS600000 E88), and recording maintenance logs.

  • EMERSON A6740 Displacement Case Expansion Monitor
  • EMERSON A6312/06 Speed Monitoring Module
  • EMERSON KJ4001X1-BE1 DeltaV Carrier Module
  • EMERSON SE3008 KJ2005X1-MQ2 DeltaV Controller
  • EMERSON KJ4001X1-CA1 DeltaV Terminal Block
  • Emerson PR6423/00R-010 CON031 Eddy Current Probe System
  • Emerson A6824 9199-00090 Operator Workstation
  • Emerson A6410 9199-00005 Operator Workstation
  • Emerson A6110 9199-00001 Operator Workstation
  • Emerson 9199-00002 A6120 Operator Workstation
  • Emerson KJ3002X1-BF1 12P1732X042 FIELDVUE DVC6200
  • Emerson 5X00500G01 Ovation Analog Output Module
  • Emerson VE4001S2T2B4 DeltaV Controller Module
  • Emerson 5X00502G01 Ovation Analog Input Module
  • Emerson A6824R 9199-00098-13 Operator Workstation
  • EMERSON A6140 9199-00058 Dual Channel Monitor
  • EMERSON VE3007 KJ2005X1-BA1 DeltaV Controller
  • EMERSON DB1-1 Connection Termination Block
  • EMERSON PMC-IO-ADAPTER Mezzanine Interface Card
  • EMERSON L0115012 L0115032 Solenoid Valve Components
  • Emerson A6410 Large Operator Workstation
  • Emerson A6210 Operator Workstation
  • Emerson 1C31232G02 Ovation Controller Module
  • Emerson 5X00106G02 Ovation Power Supply Module
  • Emerson 5X00106G01 Ovation Power Supply Module
  • EMERSON PMC-IO-PROZESSOR High-Speed I/O Module
  • EMERSON PMC PROFINET Communication Module
  • EMERSON MVME7100-0171 VMEbus Single Board Computer
  • EMERSON SE3008 KJ2005X1-SQ1 DeltaV MQ Controller
  • EMERSON PR6423/002-041 Eddy Current Displacement Sensor
  • Emerson SE4006P2 Serial Interface Module
  • Emerson KJ2201X1-HA1 Analog Input Module
  • EMERSON CE4001S2T2B4 DeltaV I/O Interface Module
  • EMERSON CE4003S2B1 DeltaV Controller
  • EMERSON KJ2003X1-BA2 DeltaV I/O Carrier
  • Enterasys A4H124-24TX P0973JM 24-Port Fast Ethernet Switch Module
  • Enterasys A2H254-16 P0973BK 16-Port Fast Ethernet Switch Module
  • Enterasys A4H254-8F8T P0973JP Matrix E5 Switch Module
  • Enterasys SSA-T8028-0652 P0973LN SecureStack Gigabit Switch
  • Enterasys A2H124-24FX P0973BJ
  • Enterasys SSA-AC-PS-625W P0973LQ Power Supply
  • Enterasys A2H124-24FX-RH Fiber Fast Ethernet Switch
  • Enterasys A2H254-16-RH Fast Ethernet Switch
  • Enterasys C2G170-24 P0973BL Stackable Gigabit Switch
  • Enterasys STK-RPS-150PS P0973BP Redundant Power Supply
  • ENTERASYS A4H124-24FX P0973JN SecureStack A4 Fiber Switch
  • ENTERASYS A4H124-24TX SecureStack A4 Ethernet Switch
  • ENTERASYS A2H124-24FX SecureStack A2 Fiber Switch
  • ENTERASYS A2H254-16 SecureStack A2 Managed Switch
  • ENTERASYS A4H254-8F8T SecureStack A4 Managed Switch
  • Enterasys C2RPS-CHAS2 Redundant Power System Chassis
  • Enterasys A2H124-24 Managed Ethernet Switch
  • EPRO PR6423/003-030-CN Hazardous Area Sensor
  • EPRO PR6424/012-000 Eddy Current Displacement Probe
  • EPRO PR6424/013-130 + CON021 Eddy Current Sensor System
  • EPRO PR6424/014-040 11mm Eddy Current Probe
  • EPRO PR6423/001-000 Eddy Current Sensor Probe
  • EPRO PR6423/010-000-CN Eddy Current Probe
  • EPRO MMS6823 9100-00001-05 Output Module
  • EPRO CON011 9200-00001N Signal Converter
  • EPRO MMS6120 Dual Channel Speed Monitor 9100-00002-10
  • EPRO MMS6120 Dual Channel Overspeed Protection Monitor 9100-00002C-08
  • EPRO PR6423 and PR6424 Eddy Current Displacement Probes
  • EPRO PR9268/300-000 Seismic Velocity Sensor
  • EPRO MMS3120/022-000 Dual Channel Vibration Monitor 9100-03047-01
  • EPRO MMS6823R 9100-00001-06 Dual Channel Module
  • EPRO PR6423/10R-030-CN Displacement Sensor
  • EPRO PR6423 Eddy Current Displacement Sensor
  • EPRO PR6423/002-030-CN+CON021 Eddy Current Sensor
  • EPRO PR9376/20 Contactless Speed Sensor
  • EPRO PR6423/002-001-CN Eddy Current Probe
  • EPRO RSM020 Relay Output Module
  • EPRO SDM010 Signal Distribution Module
  • EPRO PR6423/010-010-CN Eddy Current Sensor
  • FANUC A81L-0001-0165 Servo Motor Cable
  • FANUC A05B-2452-C900 Teach Pendant Cable
  • FANUC A90L-0001-0422#50 Cooling Fan 9WF0624H7D05
  • FANUC A860-0326-T103 Alpha iA64 Pulse Coder
  • FANUC A860-0315-T101 Alpha i Pulse Coder
  • FANUC A860-0302-T001 Alpha Series Pulse Coder
  • FANUC A230-0604-X003 Operator Panel
  • FANUC A20B-8200-0927 I/O Link Module
  • FANUC A20B-2902-0290/08C Communication PCB
  • FANUC A20B-2901-0763/02A I/O PCB Module
  • FANUC A20B-2901-066 Main PCB Board
  • FANUC A20B-2002-0040/07DR Servo Control PCB
  • FANUC A16B-2203-0073/02A Power Supply PCB
  • FANUC A06B-6114-H106 Alpha i Servo Amplifier
  • FANUC A06B-6089-H104 Alpha Servo Amplifier SVM1-80
  • FANUC A06B-6079-H208 Alpha Servo Amplifier Module
  • FANUC A06B-6079-H106 Servo Amplifier
  • FANUC A06B-6077-H106 Servo Amplifier
  • FANUC A06B-0116-B203#0100 Servo Motor
  • HIMA F3DIO20/802 Digital I/O Module 982200442
  • HIMA 80105 Power Supply Module 984080105
  • HIMA X-DO2401 Digital Output Module 985210203
  • HIMA X-DI3201 Digital Input Module 985210201
  • HIMA F-PWR02 Power Supply Module for F-Series
  • HIMA K1412B / H51q-HRS Safety Controller 996141261 / 997205233
  • HIMA K7214 Power Supply Module 996721402
  • HIMA TM202-A00-B00-C00-D00-E00-G00 Analog Termination
  • HIMA TM521 Digital Input Termination Module
  • HIMA TM591-B00-G00 Termination Module HIMax System
  • HIMA KFD2-STC4-Ex1 SMART Transmitter Power Supply
  • HIMA KFD2-VR4-Ex1.26 Voltage Repeater Isolated Barrier
  • HIMA SB3073-EX Intrinsically Safe Barrier Module
  • HIMA H6200A Terminal Module for Safety I/O
  • HIMA Z7130 Power Supply Distribution Module
  • HIMA F8652E 984865264 Central Module HIQuad H51q
  • HIMA F8627 984862702 Communication Module HIQuad System
  • HIMA H41q-HS High-Speed Safety Controller B4237-1 997104237
  • HIMA F8652X Central Processing Unit 984865265
  • HIMA H4135 Safety Logic Solver 992413502
  • HIMA H51q-H High-Integrity Safety Controller B5233-2 997235233
  • HIMA F6217 Safety Controller 984621702
  • HIMA F3330 984333002 Digital Output Module
  • HIMA F7553 984755302 Communication Module
  • HIMA F7131 Power Supply Module
  • HIMA X-DO1201 985210204 Digital Output Module
  • HIMA H51q-HRS B5233-2 Safety Controller Module
  • HIMA F3231 16-Channel Digital Input Module
  • HIMA K9203A (996920360) Safety Relay Module
  • HIMA H51q-HS B5233-1 Safety Control System
  • HIMA F7131 Power Supply Monitoring Module
  • HIMA F8620/11 Central Module for HIQuad Systems
  • HIMA X-FAN 18 03 Redundant Fan Module for Safety Systems
  • HITACHI LYD000A Digital Input Module 8-Channel
  • HITACHI PS6000 Heavy-Duty Power Supply 24VDC 10A