ABB MEASUREMENT & ANALYTICS Web Tension Systems with Tension Electronics PFEA113

F: | Au:FAN | DA:2025-06-26 | 560 Br: | 🔊 点击朗读正文 ❚❚ | Share:

ABB MEASUREMENT & ANALYTICS Web Tension Systems with Tension Electronics PFEA113

Product overview

1. System composition and functions

PFEA113 is the core control module of ABB's Web tension system, equipped with various types of load sensors such as PFCL 301E and PFTL 301E, which can accurately measure and control the tension of materials such as paper, plastic, and textiles during the production process. The system supports single roll, double roll, and segmented roll applications, and can connect up to 12 load sensors (through multiple PFEA113 combinations). It has 6 configurable analog outputs and 4 digital outputs, suitable for tension closed-loop control and monitoring in industrial automation production lines.

2. Technical features

Measurement technology: Presductor based on ABB patent ®  Technology converts mechanical force into electrical signals through the principle of electromagnetic induction, generating measurement signals without the need for mechanical deformation. It has high stiffness, anti vibration, and anti overload capabilities.

Accuracy and stability: 24 bit high-precision data acquisition, measurement accuracy of 0.05%, sampling rate of 10Hz, working temperature range of -20 ℃ to 60 ℃, with 2500Vrms electrical isolation and multiple protection functions (overload, over temperature, short circuit).

Communication capability: Supports various industrial communication protocols such as Profibus DP and Modbus, and can seamlessly integrate with PLC, DCS, and other systems to achieve remote monitoring and control.

Core technical principles

1. Pressductor ®  Technical principles

When the load sensor is subjected to mechanical force, the magnetic permeability of the steel core changes, causing a change in the magnetic coupling between the two sets of vertical coils wound on the steel core, thereby inducing an AC voltage signal proportional to the applied force in the output coil. The signal is processed by PFEA113 and converted into a standard output signal proportional to tension (such as 0-10V or 4-20mA).

2. Tension calculation model

The relationship between tension T and the measured force FR of the load sensor is T=Wrap Gain × FR, where Wrap Gain is the winding gain, which depends on installation parameters such as the winding angle and roller diameter of the material on the roller. The system supports setting Wrap Gain through hanging weight method or calculation method to ensure measurement accuracy.


Installation and Debugging

1. Installation requirements

Environmental conditions: Installed in a dry, ventilated, and non strong electromagnetic interference environment, IP 65 version can be used in harsh environments, and IP 20 version is suitable for indoor control cabinet installation.

Mechanical installation: The load sensor needs to be installed horizontally or obliquely to ensure that the direction of force is consistent with the measurement direction. The flatness error of the installation plane should not exceed 0.1mm. Use a torque wrench to tighten the adapter plate with the specified torque (such as 24N · m for M8 screws).

Electrical connection: The load sensor cable needs to use shielded twisted pair cables, maintaining a distance of at least 0.3m from the power cable. The shielding layer should be grounded at one end, and the maximum cable resistance should not exceed 10 Ω.

2. Debugging process

Quick settings (applicable to single/double rollers): Language, unit, and width settings can be completed through panel buttons. After zero calibration, the hanging weight method (applying known weight) or directly inputting the calculated Wrap Gain value can be selected to complete basic functional configuration.

Complete setup: including system definition (roller type, gain scheduling), object type (standard roller/single-sided measurement/segmented roller), nominal load, analog output mapping (such as AO1 corresponding tension sum), digital output threshold (high and low limit alarm), and other detailed parameter configurations.

Functional verification: Check the polarity of the load sensor signal (it should display positive when manually applying force), and ensure normal signal transmission through analog input/output testing.


Operation and maintenance

1. Operation interface

Display and buttons: 2 × 16 character backlit LCD display, supports multiple languages (English, German, French, etc.), navigates the menu through the directional keys and confirm keys, and can view the tension, difference, and alarm information of each roller in real time.

Menu structure: Includes operator menu (real-time data), configuration menu (parameter settings), and service menu (fault diagnosis, reset), supporting quick access to commonly used functions.

2. Maintenance points

Preventive maintenance: Regularly check the torque of the fixing screws and cable connections of the load sensor for looseness, clean the dust on the housing, and use compressed air to clean the debris in the sensor gap.

Fault handling: The system's self diagnostic function can detect flash memory errors, power supply failures, abnormal load sensor excitation, etc. Fault information can be obtained through panel error codes or Profibus communication. Common faults such as "Flash Memory Error" require module replacement, and "Load Cell Excitation Error" require cable and sensor inspection.

  • Basler D90 96801 100 PCB Card
  • Basler XR2002F Voltage Regulator (110 VAC, 48-480 Hz)
  • Basler SR8A-2B14B3A Regulator
  • Basler 9561500100 Module
  • Basler DECS-400 BE1-11 System
  • Basler DECS-100-B15 Excitation Control
  • Basler SCP 210 Frequency Controller
  • Basler SR4A-2B15B3A Static Voltage Regulator
  • Basler BE1-32R Power Relay
  • Basler PIA2400-17GM Power Interface Adapter
  • Basler MVC 232 Manual Voltage Control Module
  • Basler SSR 32-12 Static Voltage Regulator
  • Basler 5MW AVR Generator Voltage Regulator
  • Basler VR63-4B Voltage Regulator
  • Basler DECS-100-A05 AVR for Engine Generator
  • Basler DECS-100-B15 Automatic Voltage Regulator
  • Basler BE1-32R Directional Power Relay
  • Basler BE1-87B Differential Relay
  • Basler UFOV 260A Protective Module
  • Basler 9-2614-02-100 PCB Rev M
  • Basler DECS-100-B15 Digital AVR
  • Basler 9284900103 PS DECS-400N
  • Basler D4N3H1U Intertie Protection
  • Basler DECS-100-B15 A15 AVR
  • Basler KR4F Voltage Regulator
  • Basler BE26434 T14 Transformer
  • Basler SR8A-2B15B3A Regulator
  • Westinghouse 774B472A12 AR Relay
  • Basler DECS-100-B15 AVR
  • Basler XR2002F Regulator 110V
  • Basler SR125-E Static Regulator
  • Basler SSR 125-12 Regulator
  • Basler MOC2599 Motor Pot
  • Basler BE1-DFPR Feeder Relay
  • Basler CBS 305 Current Boost
  • Basler BE1-25 AutoSync
  • Basler MVC 300 Voltage Control
  • Basler BE3-25A AutoSync
  • Basler KR7FF Static Regulator
  • Basler 90-49000-100 Regulator
  • Basler 880 kVA Dry Type Transformer Specs
  • Basler Electric BE1-25 Sync-Check Relay Specs
  • Basler SSR 125-12 Voltage Regulator Specs
  • Basler Electric BE1-851 Overcurrent Relay Review
  • Basler Electric 149D930G02 Control Sub-Assembly
  • Basler Electric BE1-81O/UT Frequency Relay Specs
  • Basler Electric BE1-51/27C Overcurrent Relay
  • Basler Electric 149D956G02 Industrial Component
  • Basler Electric BE1-51A Overcurrent Relay Specs
  • Basler Electric BE1-40Q Loss of Excitation Relay
  • Basler DECS-200 Excitation Control System
  • Basler DECS-200 Voltage Regulator 56-277V AC / 125V DC
  • Basler BE1-87T Transformer Differential Relay
  • Basler RDP-110-S1 Protection Relay
  • Basler BE1-700V Digital Protective Relay
  • Basler BE1-951 Overcurrent Protection System
  • Basler DECS-300 Digital Excitation Control
  • Basler DECS-200 Digital Excitation Control
  • Basler DECS-200-1C Excitation Control System
  • Basler DECS-200-1L Digital Excitation Control
  • Basler Electric BE1-GPS Generator Protection System
  • Basler Electric DECS-200-1C Digital Excitation Controller
  • Basler Electric DECS125-15 Excitation Control with Power Module
  • Basler Electric BE1-87G Differential Relay
  • Basler Electric BE1-11 Protection System I5A3M2P2N0EA00
  • Basler Electric DECS-200-1C Excitation Control System
  • Basler Electric BE1-11g Generator Protection Relay
  • Basler Electric DECS 125-15-B2C1 V2.0.9 Excitation Control
  • Basler Electric BE1-81O/UT3ED1JA7N2F Frequency Relay
  • Basler Electric BE1-81O/UT3EE1YB7N1F Frequency Relay
  • Basler Electric DECS-200-1L Digital Excitation Control System
  • Basler DECS125-15-B2C1 Excitation Control
  • Basler 9507900205 SSR Retrofit Voltage Regulator
  • Basler BE2000E Digital Voltage Regulator
  • Basler BE1-GPS Generator Protection System
  • Basler DECS-250-CN1CN1N Digital Excitation Control
  • Basler DGC-2020 Genset Controller
  • Basler BE1-81O UT3ED1LA7N0F Frequency Relay (Variant)
  • Basler BE1-81O UT3EE1YA9S0F Frequency Relay (Variant)
  • Basler BE1-81O Over/Under Frequency Relay
  • Basler DECS125-15 Digital Excitation Control
  • Basler Electric BE1-951 Overcurrent Protection System
  • Basler Electric BE1-700V Digital Protective Relay
  • Basler Electric APR63-5 Automatic Voltage Regulator
  • Basler Electric BE1-851 Overcurrent Protection System
  • Basler Electric DECS-250-LN1SN1N Excitation Control
  • Basler Electric BE1-87T Transformer Differential Relay
  • Basler Electric DECS-200-1L Excitation Control System
  • Basler Electric 9310300100 DECS-300 Excitation Control
  • Basler Electric SSE-N 125-4.5KW Shunt Exciter Regulator
  • Basler Electric DGC-2020HD-5NS1DNSBA Genset Controller
  • Basler Electric BE1-81-O/UT3EE1JB7N1F Frequency Relay
  • Basler Electric BE1-81T1EE1WA0N1F Frequency Relay
  • Basler Electric BE1-25M1EA6PN5R1F Sync-Check Relay
  • Basler Electric BE1-GPS Generator Protection System
  • Basler Electric DECS-250-LN1SN1N Excitation Control Rev V
  • Basler Electric DECS-250-CN2CN1N Excitation Control
  • Basler Electric BE1-50/51B-207 Overcurrent Relay
  • Basler Electric DECS-300-C0N0 Excitation Control System
  • Basler Electric DECS-200 Digital Excitation Control System
  • Basler Electric DECS-250-LN1CN1N Excitation Unit
  • Basler Electric DECS-250 LN2SA1D Excitation Unit Specs
  • Basler Electric BE1-87T Transformer Relay Review
  • Basler Electric BE1-11 Protection System
  • Basler Electric BE1-GPS100-E4N1H1N Protection System
  • Allen-Bradley 442G-MABH-R Safety Module
  • Beckhoff CX1030-0111 PLC Assembly Profile
  • FANUC IC693CPU364 PLC Module
  • Orange Denmark Type 200816 220 PLC Specs
  • OMRON C200H-SNT31 Sysmac PLC Module
  • Allen Bradley 20AB022A3AYNANC0 PowerFlex 70
  • OMRON C200HW-PCU01 Position Control Unit
  • ABB AO845A-eA Analog Output Module
  • OMRON CJ1M-CPU22 CPU Unit
  • Allen Bradley 100-E265ED11 Contactor
  • Honeywell 51304511-100 Interface Module
  • SOLEXY BXF3S0101N0018 Gateway Module
  • OMRON CJ2H-CPU65 CPU Unit
  • Automation Direct GS2-45P0 AC Drive
  • M68-2000 2-Axis Motion CNC Controller
  • OMRON CJ1M-CPU11 V3.0 PLC CPU Unit
  • OMRON CJ1W-NC413 4-Axis Positioning Controller
  • OMRON 3G2A3-PRO16 Programming Console HMI
  • Siemens 3VT8440-2AA04-2GA2 Molded Case Circuit Breaker
  • Siemens 3RT5045 Contactor Series
  • OMRON C200HS-CPU01-E SYSMAC PLC Controller
  • OMRON C500-NC103-E Positioning Control Unit
  • OMRON CJ1W-TC001 Temperature Control Unit