Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:

UniOP Universal Operation Panel Installation Guide

来源: | 作者:FAN | 发布时间 :2026-03-09 | 30 次浏览: | Share:

UniOP Universal Operation Panel Installation Guide

In modern industrial automation systems, the human-machine interface serves as an important bridge connecting operators and control systems, and its stability and ease of use directly affect production efficiency and safety. The UniOP series universal operation panel, designed and manufactured by SITEK S.p.A in Italy, is widely used in various industrial environments due to its diverse model selection, flexible communication interfaces, and robust industrial grade design. This article is compiled and written based on the official "UniOP Universal Operator Panel Installation Guide" (document code: MANUUNIOP22, version 1.08), aiming to provide engineers and technicians with a detailed, professional, and practical reference guide for installation and debugging.


Product Overview and Model Identification

The UniOP series of operation panels covers a variety of models from simple text display to high-resolution color touch screens, meeting the needs of different industrial scenarios. According to the differences in display technology and functionality, it can be mainly divided into the following categories:

Text panel: such as CP01F-02, CP02R-04, etc., using VFD or LCD display, suitable for simple data monitoring.

Graphic panel: such as BKDC-16, BKDL-16, etc., supporting 320x240 resolution graphic display, suitable for more complex interface design.

High end touch screen panels, such as ePAD30T and eTOP series, support TFT color display and resistive touch technology, with a resolution of up to 1024x768.

All models are equipped with real-time clocks, user replaceable lithium batteries (model CR2430), and multiple communication interfaces to ensure data retention even after power outages.


Technical specifications and environmental requirements

The UniOP panel fully considers the strictness of industrial environments in its design, and its technical parameters are as follows:

Working temperature: The standard model is 0 to+50 ℃, and some models (such as those with A6/A7 suffixes) can be extended to -20 to+60 ℃.

Storage temperature: -20 to+70 ℃.

Humidity range: 5% to 85% RH (non condensing).

Protection level: The front panel meets the IP65 standard and must strictly follow the installation instructions to ensure sealing.

Anti interference capability: Complies with the EN 61000-4 series standards and has good electromagnetic compatibility.

In addition, the built-in lithium battery on the panel is used to maintain clock and RAM data, with a lifespan of about one year, and needs to be replaced in a timely manner when low voltage prompts.


Installation environment and mechanical dimensions

To ensure long-term stable operation of the equipment, the installation environment must meet the following conditions:

Avoid direct sunlight: Prolonged exposure can accelerate the aging of the front panel film.

Stay away from corrosive substances: Before installation, the resistance of the front panel material to on-site chemicals should be confirmed.

Proper installation of sealing strips: Rectangular or strip-shaped sealing strips must be used according to the diagram to ensure IP65 protection level.

The installation dimensions of different models vary, and detailed mechanical diagrams are provided in the manual. Taking BKDC-16 as an example, its external dimensions are 216x168x82 mm, and the opening size needs to be accurately matched with an error controlled within ± 0.5 mm. Four fixed brackets are required during installation, fixed from the long edge near the corner until the frame contacts the surface of the panel.

Definition of Electrical Connections and Interfaces

The electrical connections of the UniOP panel include power supply, PLC interface, PC/printer interface, AUX expansion port, and external keyboard interface.

1. Power supply and grounding

All models support 24VDC power supply, with current consumption ranging from 250mA to 1300mA depending on the model. The power wiring must use a three core cable, and the grounding terminal must be firmly connected to the system grounding grid to ensure anti-interference capability. Some models, such as the ePAD series, have built-in overcurrent protection and do not require external fuses.

2. PLC interface

The PLC port is a D-sub 15 pin male connector, supporting multiple communication standards such as RS-232, RS-422, RS-485, and 20mA current loop. The specific signal allocation is as follows:

Pin 2: RXD

Pin 3: TXD

Pin 5: GND

Pin 6/7: CHA -/CHB-

Pin 8/9: TX+20mA/TX-20mA

Pin 14/15: CHA+/CHB+

The communication speed range is 300 to 38400 baud, depending on the PLC type. Special cables are required to ensure stable communication.

3. PC/printer interface

This interface is a D-sub 15 pin female head and supports RS-232 communication. Used to connect to a PC for project download (using CA2 or CA114 cables), or to connect to a serial printer in running mode. Some low-end models do not have this interface and require programming through a PLC port in conjunction with an adapter.

4. AUX expansion port

The AUX port is a 9-pin D-sub interface that supports the expansion of industrial fieldbus modules such as Profibus, DeviceNet, etc. When installing the module, it is necessary to first remove the back cover, insert the module and fix it, and finally paste the function label.

  • UNIOP eTOP20C-0050 Color HMI Touch Panel Data
  • UNIOP MD00R-02-0045 Text-Based Display Module
  • UNIOP eTOP05-0045 Operator Interface
  • UNIOP ETOP11-0050 HMI Color Operator Interface Data
  • UNIOP eTOP306 Industrial Touch Panel
  • UNIOP CP04F-04-0045 HMI Panel
  • UNIOP ETOP308U301 HMI Touch Panel
  • UNIOP MD00R-02-0045 Operator Panel
  • UNIOP ePALM10-0061 Handheld Teach Pendant
  • UNIOP CP05R-04-0045 HMI Operator Panel
  • UNIOP MD02R-04-0045 Text-Based Operator Module
  • UNIOP CP02R-04-0021 Compact Operator Panel
  • UNIOP CP04F-04-1945 Industrial HMI Control Panel
  • UNIOP ECT-16-0045 Communication Module Data Sheet
  • UNIOP EPALM10-0061 Handheld HMI Technical Specifications
  • UNIOP ERT-16-0042 Remote Terminal Unit
  • UNIOP ePAD04-0046 HMI Controller
  • UNIOP BKDR-16 Operator Interface Display
  • UNIOP MKDR-04-004 Control Unit Panel
  • UNIOP ETOP515U3P1 HMI Touch Panel
  • AMAT 0190-15779 Advanced Controller Module
  • Applied Materials AMAT 0010-23715 Mechanical Assembly
  • AMAT 0190-14502 Communication Interface Module
  • AMAT 0195-14157.RMA Power Distribution Module
  • Applied Materials AMAT 0021-84842 Precision Component
  • AMAT 0190-37519 DC Power Supply
  • AMAT 0100-71267 RF Generator Module
  • ALSTOM V4561484-0100 Analog Input Module
  • ALSTOM PIB903 Process Interface Board
  • ALSTOM 029.202.781 Protection Relay
  • ALSTOM 029.148.924 Enhanced Motor Relay
  • ALSTOM 029.148.906 Motor Protection Relay
  • ALSTOM 029.147.908 Transformer Protection Relay
  • ALSTOM 029.144.456 Advanced Feeder Relay
  • ALSTOM 029.144.440 Feeder Protection Relay
  • ALSTOM P40 AGILE MiCOM P141 Feeder Protection Relay
  • ALSTOM I/OBE2 12004-104-00 V1.0.0 I/O Interface Module
  • ALSTOM V4561983-0100 Industrial Control Module
  • ALSTOM VOOB8-B 12004-106-04 V1.0.0 Output Interface Board
  • ALSTOM VPS 12004-102-03 V1.0.0 Voltage Processing Board
  • ALSTOM POS1846 TRVC062333000 CP00000310 Position Control Module
  • ALSTOM DSI1817 TRVC062335000 CP00003934 Digital Input Module
  • ALSTOM CMP1838 TRVCO62345000 CP00005202 Processor Module
  • ALSTOM STO1726KO1 Integrated Control Module
  • ALSTOM I/OBUS2 12004-103-01 VER:V1.2.0 Communication Interface
  • ALSTOM 730475-D ELEMENTS-F2 Cabinet Heater
  • ALSTOM N897163510Q / N897163050Q MODEM and N897163100U Interface Unit
  • ALSTOM N897066 AOVD Analog Output Module
  • ALSTOM CMU 42015-115-00 Communication Unit
  • ALSTOM NRD108028 Digital Protection Relay
  • ALSTOM 42011-106-00 ITC_VIOM_VIOC VER.A01 Interface Card
  • ALSTOM N897093511D DIAGNOSTICA N897093400H Interface Unit
  • ALSTOM N895609510K N895609010R E32OUT Digital Output Module
  • ALSTOM MLU VER.A01 Main Logic Unit
  • ALSTOM NRD109475 8RDA44670G01 SA44670.E Control Module
  • ALSTOM VIIB16-C 12011-105-00 Interface Board Module
  • ALSTOM VCS232 590.043158 Control System Module
  • ALSTOM V0701596-001102 Industrial Control Module
  • ALSTOM N895313512X N95313012D SUP-AL Control Module
  • ALSTOM 12004-102-01 VPS Board Ver.C Power Control Board
  • ALSTOM NRD108034 8RDB44674G01 SA44674.C Control Card
  • ALSTOM N897092520B N897092057Y TRENO N897092500E
  • ALSTOM NRD108033 8RDC44667G01 SA44667.C Control Circuit Board
  • ALSTOM TRVC062105000 TRVC070938000 Series Specification
  • ALSTOM SDK-C0147 12004-101-00 SBS04M17C Control Module Technicals
  • ALSTOM N895313512X Digital Output Module
  • ALSTOM P70035W82V Feeder Protection Relay
  • ALSTOM N897164624A Digital Input Module
  • ALSTOM N897164611M Power Supply Module
  • ALSTOM N897164610L Communication Interface Module
  • ALSTOM N70032702L Protection Relay Module for Power Systems
  • ALSTOM MVAJ21L1GB0771B Voltage Protection Relay
  • ALSTOM MFAC34N1AA0001A Overcurrent Protection Relay
  • ALSTOM MCTI40N1AB0751G Current Differential Protection Relay
  • ALSTOM MCGG22L1CB0753E Overcurrent Protection Relay
  • ALSTOM MVAW 11B1AB0513A Trip Circuit Supervision Relay
  • ALSTOM MVTU 11K1CD0751G Voltage Transformer Supervision
  • ALSTOM MVAJ27L1FB0784D High Speed Tripping Relay Guide
  • ALSTOM MAVS01L1AB0501D Voltage Selection Relay Documentation
  • ALSTOM MVAW11B1AB9007A Trip Circuit Supervision Relay
  • ALSTOM MFAC14K1AA0001A Feeder Protection Relay
  • ALSTOM MCGG62N1CB0753F Generator Protection Relay
  • ALSTOM MAVS01L1AB0751D Protection Relay
  • ALSTOM PIB1201A 3BEC0067 Interface Module
  • ALSTOM V4555724-0100 Voltage Protection Relay
  • BENTLY 1900/65A-01-01-03-00-01 Monitor
  • BENTLY 3500/42-01-00 Proximitor Monitor
  • BENTLY 3500/54-03-00 Temperature Monitor
  • BENTLY 163179-02 Accelerometer
  • BENTLY 3500/94 145988 Display
  • Bently Nevada 1X35668 Replacement Internal Component Analysis
  • Bently Nevada 3500/22M 138607/01 Transient Data Interface
  • Bently Nevada 3500/40M 135489-04 Proximitor Monitor Module
  • Bently Nevada 3500/40M 125680-01 Proximitor Monitor
  • Bently Nevada 3500/15 127610-01 Power Supply Module
  • Bently Nevada 1900/65A-00-01-01-01-01 Machinery Monitor
  • Bently Nevada 3500/65 145988-02 Temperature Monitor
  • Bently Nevada 330876-03-50-00-00 Proximity Probe
  • BENTLY 3500/93 135785-02C System Display Module
  • BENTLY 3701/55 323174-01 ADAPT Input/Output Module
  • BENTLY 3500/42M 140734-99 Modification Module
  • BENTLY 3701/55 289761-01 ADAPT Emergency Shutdown Device
  • BENTLY 3500/42M 140734-02 Proximitor Seismic Monitor
  • BENTLY 3500/15 114M5330-01 Power Supply Module
  • BENTLY 3500/92 136180-01 Communication Gateway
  • BENTLY 3500/93 135799-01 LCD Display Module
  • BENTLY 3500/22 Transient Data Interface Module
  • BENTLY 9200-01-01-10-00 General Purpose Monitor
  • BENTLY 3500/65 145988-02 Temperature Monitor
  • BENTLY 1900/65A 172323-01 General Purpose Monitor
  • BENTLY 3500/22M 138607-01 Transient Data Interface
  • BENTLY 149986-01E 3300 XL 8mm Proximity Probe
  • BENTLY 1900/65A-01-01-03-00-01 General Purpose Monitor
  • BENTLY 136719-01 3500/92 Communication Gateway I/O
  • BENTLY 3500/22-01-01-00 Transient Data Interface Module
  • BENTLY 3500/22M 288055-01 Transient Data Interface
  • BENTLY 131151-01 3500/50 Tachometer I/O Module
  • BENTLY 1900/65-00-01-03-01-01 General Purpose Monitor
  • Bently Nevada 3500/54 133396-01 Overspeed Detection Monitor
  • Bently Nevada 3500/45 176449-04 Position Monitor
  • Bently Nevada 3500/42 140471-01 Proximitor Monitor
  • Bently Nevada 3500/94 147663-01 VGA Display Module
  • Bently Nevada 3500/42M 140482-01 Proximitor Monitor
  • BENTLY 3500/53 133396-01 Relay Module (Alternate Version)
  • BENTLY 3500/20 125744-01 Rack Interface Module
  • BENTLY 3500/53 133388-01 Relay Module
  • BENTLY 3500/15 114M5335-01 Power Supply Module
  • BENTLY 3500/40M 140734-01 Proximitor Monitor Module