Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • Siemens 6SL3130-1TE24-0AA0 Smart Line Module
    ❤ Add to collection
  • Siemens 6SL3130-1TE24-0AA0 Smart Line Module

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥31624.00
      ¥33236.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:16.240KG
    • Quantity:
    • (Inventory: 4205)
Description
<span style="font-size: 18px; font-family: arial;">Siemens 6SL3130-1TE24-0AA0 Smart Line Module 24kW</span>

Siemens 6SL3130-1TE24-0AA0 Smart Line Module for SINAMICS S120

The Siemens 6SL3130-1TE24-0AA0 is a Smart Line Module belonging to the SINAMICS S120 drive system family. This module is an active infeed unit that converts three-phase AC mains power into a regulated DC link voltage to supply multiple Motor Modules (inverters) in a common DC bus configuration. With a rated power of 24 kW and an input voltage range of 380-480 V AC, it is designed for high-performance industrial drive applications requiring regenerative energy feedback. The Smart Line Module features active line filtering, low harmonic distortion (THD < 3%), and a built-in brake chopper for dynamic braking. It is suitable for use in machine tools, printing presses, winders, and other demanding motion control systems.

Technical Specifications

Rated power: 24 kW. Input voltage: 3-phase 380-480 V AC ±10%, 50/60 Hz. Input current: 41 A. Output DC link voltage: 600 V DC (regulated). DC link current: 42 A (continuous). Brake chopper: integrated, external braking resistor required. Overload capability: 1.5 × rated current for 30 seconds. Efficiency: approx. 98%. Cooling: internal fan. Protection rating: IP20. Dimensions: 240 mm (H) × 100 mm (W) × 230 mm (D). Weight: 5.5 kg. Operating temperature: 0°C to 40°C (derating up to 55°C). Storage: -40°C to 70°C. Communication: via DRIVE-CLiQ interface. Standards: CE, UL, cUL, RoHS.

Key Features

  • Active line infeed with regenerative capability for energy savings

  • Low harmonic distortion (THD < 3%) meets IEEE 519 requirements

  • Regulated DC link output (600 V DC) for up to 42 A continuous

  • Built-in brake chopper for dynamic braking (external resistor required)

  • Compact booksize format for space-saving cabinet installation

  • DRIVE-CLiQ interface for digital communication with SINAMICS S120

  • Integrated protective functions: overvoltage, undervoltage, overcurrent, overtemperature

  • High efficiency (98%) reduces cooling requirements


Operation in SINAMICS S120 System

The 6SL3130-1TE24-0AA0 Smart Line Module operates as the central power supply for a multi-axis SINAMICS S120 drive system. It connects to the three-phase mains supply and generates a regulated DC link voltage. Multiple Motor Modules (up to 200 kW total) can be connected to the same DC bus to share power and regenerative energy. The active infeed technology allows the module to feed back braking energy into the mains supply, significantly reducing energy consumption in applications with frequent deceleration. The built-in brake chopper handles short-term overvoltage when the mains cannot absorb regenerative energy.

Configuration and Integration

The module is configured via Siemens STARTER or SINAMICS Startdrive software (TIA Portal). DRIVE-CLiQ cables automatically identify the module to the Control Unit. Parameters include mains type, line voltage, current limits, and braking resistor settings. The module supports PROFIBUS or PROFINET communication through the Control Unit. LED status indicators provide diagnostics: ready, fault, DC link active, and brake chopper activity.

Applications

The 6SL3130-1TE24-0AA0 is used in multi-axis drive systems for machine tools (milling, turning centers), packaging machines (flow wrappers, cartoners), printing presses (web tension control), winders and unwinders, and handling systems (robots, pick-and-place). Its regenerative capability is particularly beneficial for applications with frequent stop-start cycles or overhauling loads, such as cranes, centrifuges, and test stands.


Installation and Wiring

Mount the module vertically on a DIN rail or backplate. Provide 100 mm clearance above and below for airflow. Connect the three-phase mains to terminals L1, L2, L3. Connect the DC link output to the Motor Modules via busbars or cables. Connect the external braking resistor to terminals R+ and R- (if used). Connect DRIVE-CLiQ cables to the Control Unit. Use shielded cables for all connections. Earth the module via the PE terminal. Ensure the mains supply has appropriate fusing (e.g., 63A). The module requires an upstream line reactor (recommended) for harmonic compliance.

Protection and Maintenance

The module includes overvoltage, undervoltage, overcurrent, and overtemperature protection. A red LED indicates a fault; the fault code can be read via the Control Unit. The internal fan has a typical life of 40,000 hours; replace it if noisy or failed. No other user-serviceable parts. Periodically clean the air intake and exhaust vents.

Conclusion

The Siemens 6SL3130-1TE24-0AA0 Smart Line Module provides efficient, regenerative power conversion for SINAMICS S120 multi-axis drive systems. Its active infeed, low harmonics, and built-in brake chopper make it a suitable choice for high-performance industrial motion control applications.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Edwards CTI Kryogenics On Board 8F Enhanced Cryopump Explanation
  • ADLINK PCI-9112 Multi functional Data Acquisition Card
  • ADLINK PCI-8102 Two Axis Pulse Motion Control Card
  • ADLINK PCI-9812/10 high-speed synchronous acquisition card
  • ADLINK PCI-7200 High Speed Digital I/O Card
  • ADLINK MXE-1000 series fanless industrial computer
  • ADLINK IMB-T10 Mini ITX Embedded Motherboard
  • ADLINK HSL-DO32-M-N/P distributed I/O module
  • ADLINK DAQ-2500 Series Multi Channel Analog Output Card
  • ADLINK DAQ-2200 Series Data Acquisition Card
  • ADLINK ETX-AT-N270 Embedded Module
  • ADLINK ACL-7225B Relay Isolation Input Card Guide
  • ADLINK DAQ-2000 Synchronous Sampling and Acquisition Card Selection Guide
  • ADLINK NuPRO-E330 Industrial Motherboard Selection and Deployment
  • ADLINK ACL-8112 Data Acquisition Card Configuration and Programming
  • ADLINK USB-2405 Dynamic Signal Acquisition Module Deployment Guide
  • ADLINK PXIS-3320 PXI chassis installation troubleshooting
  • ADLINK PCIe-GIE72/74 Image Acquisition Card Deployment Guide
  • ADLINK PCIe-7856/7853 Sports I/O Controller Card Guide
  • ADLINK PCI-6308 Isolation Output Card Programming and Installation
  • ADLINK PCI-7432 installation and configuration troubleshooting
  • adlink nupro-e72 التحكم الصناعي اللوحة
  • ADLINK NuPRO-E72 Industrial Control Motherboard
  • ADLINK MXE-5400 Industrial Control Computer
  • ADLINK M-322 Industrial Motherboard Configuration and Deployment Guide
  • ADLINK IMB-M43H Industrial Motherboard Configuration and 6th/7th Generation Core Deployment Guide
  • ADLINK IMB-M42H Industrial Motherboard Deployment and BIOS Optimization Guide
  • ADLINK i915GV-INA motherboard configuration and ISA compatibility tuning guide
  • ADLINK ETX-NR667 Core2 Duo Module Selection and Deployment
  • ADLINK ETX-BT Module Configuration and PATA to SATA Upgrade Guide
  • ADLINK CM1-BT1 Extreme Environment Deployment and Configuration
  • ADLINK cPCI-8217 VGA/LCD Module Configuration and Troubleshooting
  • ADLINK AmITX-SL-G Mini ITX Motherboard Deployment and SEMA Guide
  • ADLINK AmITX-AL-I Embedded Motherboard Deployment and SEMA Management Guide
  • ADLINK NuPRO-E315 PICMG 1.3 Industrial Motherboard Deployment Guide
  • ADLINK NuPRO-842 Pentium 4 Industrial Motherboard Deployment and Debugging Guide
  • ADLINK NuPRO-900A Dual Xeon ePCI-X Motherboard Deployment Guide
  • ADLINK cPCI-6910 Dual Core Xeon Single Board Computer Deployment Guide
  • ADLINK cPCI-6860A Dual Xeon Single Board Computer Deployment Guide
  • ADLINK CPCI-8168 Eight Axis Motion Control Card Deployment and HSL Integration Guide
  • ADLINK NuPRO-E340 Industrial Motherboard Debugging and BIOS Optimization Guide
  • ADLINK NuPRO-A40H Industrial Single Board Computer Hardware Deployment and BIOS Calibration Guide
  • ADLINK NuPRO-852 LGA775 Industrial Control Motherboard Maintenance Guide
  • ADLINK NuPRO-841 Industrial Motherboard Maintenance and Troubleshooting
  • ADLINK NuPRO-590 Series Socket7 Industrial Control Motherboard Maintenance Guide
  • Deployment and Troubleshooting of ADLINK MXE-5500 Series Industrial Control Computer
  • ADLINK MXE-200 Fanless Embedded Industrial Control Computer Deployment Guide
  • ADLINK cPCI-6770 Series CompactPCI Motherboard Maintenance Guide
  • ADLINK NuPRO-A301 Industrial Motherboard Troubleshooting Manual
  • ADLINK NuPRO-965 SHB Debugging and Maintenance Complete Manual
  • ADLINK NuPRO-935A Industrial Motherboard Debugging and Maintenance Guide
  • ADLINK NuPRO-865 Single Board Computer Hardware Troubleshooting Guide
  • ADLINK NuPRO-840 P4 Industrial SBC Architecture Maintenance
  • ADLINK NuPRO-770 Full length SBC Configuration and Maintenance
  • ADLINK NuPRO-595 Industrial Half length SBC Motherboard Configuration and Maintenance Guide
  • ADLINK cPCI-6840 Series Single Board Computer Installation, Configuration, and Maintenance Guide
  • Foxboro 43AP Pneumatic Controller Technical Specifications and Selection Guide
  • ADLINK cPCI-3720: 3U CompactPCI Low Power Pentium III CPU Module
  • ADLINK NuPRO-E47: PICMG 1.3 13th Generation Core Industrial SHB
  • ADLINK NuPRO-E43: PICMG 1.3 Core 7th Generation Industrial SHB
  • ADLINK NuPRO-780 PICMG Bus Core CPU Card
  • ADLINK cPCI-6965 6U CompactPCI Core Dual Core Single Board Computer
  • ADLINK USB/LPCI/LPCIe-3488A GPIB Interface Card Selection and Application Guide
  • Rittal SK 3241.700 Blue e+Cabinet Fan Filter Unit
  • ADLINK CPCI-8168 8-Axis Motion Control Card and HSL Network Integration Solution
  • ADLINK PCIe-PXIe-8638 High Speed PXIe Bus Expansion Scheme
  • ADLINK PCIe GIE7x Poe+Frame Grabber Hardware and Power Management Detailed Explanation
  • ADLINK PCIe-7396 Digital I/O Card Deployment Guide
  • ADLINK PCI-8164 Advanced Motion Control Card Deployment Guide
  • ADLINK PCI-8154 Motion Control Card Deployment Guide
  • ADLINK PCI-8134 Motion Control Card Deployment Guide
  • ADLINK NuPRO-E42 Industrial Control Motherboard Deployment Guide
  • ADLINK MXC-6600 Embedded Platform Deployment Guide
  • ADLINK MXC-6000 Industrial Control Computer Deployment and Optimization Guide
  • ADLINK MXC-2300 Embedded System Deployment Guide
  • ADLINK MCM-204 Edge DAQ Deployment Configuration Guide
  • ADLINK MCM-100/102 Deployment Calibration Guide
  • Deployment and Performance Optimization of ADLINK MXC-6400 Industrial Control Computer
  • Selection and Deployment of ADLINK Matrix Series Industrial Control Computers
  • российские промышленные новые машины.Наш отдел дебютировал в 2026 году в России Международная промышленная ярмарка INNOPROM
  • Deeply cultivating the Eurasian industrial market, linking new industrial opportunities between China and Russia
  • Deployment and troubleshooting of ADLINK GIE64+PoE acquisition card
  • Honeywell UMS Security System Troubleshooting Guide
  • Honeywell Expert Series C I/O Troubleshooting Guide
  • ADLINK EOS-1200 Vision System Deployment and Troubleshooting
  • ADLINK DLAP-5200 series AI engine deployment and optimization
  • ADLINK DLAP-4000 Deployment and BIOS Optimization
  • ADLINK Matrix MXC-2000 Deployment and Troubleshooting
  • ADLINK DAQe-2000 series acquisition card calibration and synchronization
  • ADLINK cPCI-6520 Core i7 Processor Blade Engineering Application Guide
  • ADLINK CM1-86DX3 PC/104 Embedded Single Board Computer Engineering Application Guide
  • Honeywell DC1000 Series PID Temperature Controller Engineering Application Guide
  • ALSTOM MiCOM C264 Substation Controller Engineering Application Guide
  • EMERSON AMS 2140 Practical Guide for On site Dynamic Balance and Vibration Analysis
  • ADLINK NuPRO-E320 motherboard deployment and tuning guide
  • ADLINK NuPRO-800 Dual PIII Industrial SBC Maintenance and Upgrade Guide
  • ADLINK NuPRO-598 SBC Maintenance Practical Guide
  • ADLINK MXC-6300 Fanless Embedded Industrial Control Computer Deployment Guide
  • ADLINK Express-BASE7 Carrier Board Quick Deployment and Debugging Guide
  • ADLINK DLAP-211 Edge AI Platform Selection and Deployment Guide
  • ADLINK 7230 Series Isolation DIO Card Selection and Engineering Application Guide
  • ADLINK cPCI-6965 SBC Embedded Installation and BIOS Tuning Guide
  • ADLINK 7200 Series High Speed DIO Card Practical Guide
  • ADLINK DLAP Series Edge AI Acceleration Platform Selection and Deployment Practical Guide
  • DEIF TCM-2 thyristor control module: Wind power cut in control engineering guide
  • DEIF MVR-200 Medium Voltage Relay: Installation and Wiring Engineering Guide
  • DEIF MDR-2 Differential Relay: Engineering Guide for Generator Differential Protection
  • DEIF Delomatic 3 AOM: Engineering Guide for Analog Output Modules
  • DEIF AGI 400 Graphic Interface: Ship and Industrial HMI Solution
  • DEIF BRW-1 Marine Instruments: Installation and Calibration Guide for Offshore Bridge Indicators
  • DEIF AGC 200 Controller: Quick Deployment and Configuration Guide for Generator Sets
  • DEIF AGC-2 Controller: The Ultimate Guide to Automatic Control and Protection of Generator Sets
  • ABB SPA-ZC400 Gateway: REM54x Access to IEC 61850 Ultimate Engineering Guide
  • ABB REM 543/545 Terminal
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit