Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • Square D 8536SCG3V02S Motor Starter
    ❤ Add to collection
  • Square D 8536SCG3V02S Motor Starter

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥54323.00
      ¥55332.00
      ¥54323.00
      ¥54323.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.540KG
    • Quantity:
    • (Inventory: 5346)
Description
<span style="font-size: 18px; font-family: arial;">Square D 8536SCG3V02S Motor Starter</span>

Square D 8536SCG3V02S NEMA Size 3 Magnetic Motor Starter

The Square D 8536SCG3V02S is a magnetic motor starter from the Class 8536 series, designed for starting and stopping three-phase AC motors. It is a NEMA size 3 starter rated for motors up to 30 hp at 240 V, 50 hp at 480 V, and 60 hp at 600 V. The unit includes an electromechanical contactor and a built-in overload relay for thermal protection. The open-style enclosure (no outer case) is intended for installation inside a control panel.

Electrical Ratings

Contactor: rated continuous current 90 A. AC-3 rating (three-phase): 400 V: 45 kW, 690 V: 55 kW. Coil voltage: 120 V AC, 60 Hz (inrush VA 900, sealed VA 100). Overload relay: bimetallic, adjustable from 27 to 45 A (class 20 trip curve). The starter has three power poles (3 NO) for line and load connection. Control circuit: two auxiliary contacts (1 NO + 1 NC) are provided as standard.

Protection Features

The overload relay includes ambient temperature compensation, phase loss sensitivity, and manual/automatic reset selection. A trip indicator shows when the overload has opened. The contactor has an encapsulated coil for moisture resistance and integral arc chutes for safe interruption of fault currents up to 10 kA (with appropriate fuses). Short-circuit protection must be provided upstream (recommended fuse type CC or J).

Mechanical and Mounting

Dimensions: 6.0 in x 6.5 in x 5.5 in (W x H x D). Weight: 4.5 lb. The starter mounts via four keyhole slots on a backplane (screws not included). Terminal type: box lugs for #4 AWG to #14 AWG copper wire. Tightening torque: 31 in-lb for power terminals, 20 in-lb for control terminals. Operating temperature: -10°C to 60°C. The unit meets NEMA standards ICS 2-2000 and UL 508 listing.

Installation and Wiring

The starter accepts incoming line voltage on L1, L2, L3 and outgoing motor leads on T1, T2, T3. The coil is wired to A1 and A2 (120 V AC). The overload relay’s NC contact (95-96) must be wired in series with the coil’s seal-in circuit. An optional auxiliary contact block (e.g., 8501X040) can be added to the side. The starter’s open design requires a clean, dust-free cabinet.

Typical Applications

Used for across-the-line starting of pumps, compressors, conveyors, HVAC fans, and industrial mixers. The NEMA design provides ruggedness and serviceability; contacts can be replaced without removing the unit from the panel. The 8536SCG3V02S is a common choice for machine tool controls and agricultural equipment.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice
  • PULS QS40.241 Power Supply Practical Guide
  • Eaton XV-102-L Touchscreen Installation Guide
  • Omron FZ5 Vision System Selection and Configuration Guide
  • Schneider TSX47 series PLC selection
  • ABB CS31 distributed debugging
  • OMRON H8PR electronic cam debugging
  • OMRON MX2 frequency converter debugging
  • GP477R Engineering Installation
  • Siemens AS-i SlimLine Diagnostic Guidelines
  • OMRON NS Series PT Remote Access
  • OMRON Z4M sensor precision measurement
  • HIMMERWERK SINUS High Frequency Induction Heating Selection
  • OMRON CP1E PLC Practical Selection Guide
  • OMRON ZFX-C Vision Sensor in Practical Use
  • OMRON ZFV Intelligent Sensor Practical Guide
  • OMRON CJ Series PLC Practical Guide
  • Murr SIRCO Isolation Switch Selection Guide
  • OMRON ZFX Vision Sensor Engineering Practice
  • REER ULISSE UNC Security Light Curtain Practice
  • Siemens S5-90U/95U Fault Diagnosis and Advanced Programming
  • OMRON CPM2C system fault diagnosis and maintenance
  • Yaskawa ∑ - V Servo Drive Debugging Guide
  • OMRON CP1H PLC Practical Manual
  • OMRON K-type PLC Maintenance Guide
  • PEPPERL+FUCHS SLVA-4Kplus Safety Light Curtain Guide
  • Yaskawa ∑ - II Servo Drive Debugging Guide
  • Yaskawa VS-616PC5/P5 frequency converter practical application
  • OMRON 3G3SV Inverter Practical Manual
  • Pro face GP370 Complete Guide
  • OMRON FQ2 Smart Camera Selection Guide
  • Practical Guide to Sony SH800 Sorter
  • OMRON Cam Positioner Complete Guide
  • KEB F4 Inverter Debugging Guide
  • OMRON CJ series PLC operation and maintenance essentials
  • Essentials of Schneider C60H-DC DC DC Protector
  • OMRON 3G3MV Inverter Practical Guide
  • Essentials of OMRON CQM1H PLC System
  • Essentials of ARD Elevator Emergency Rescue Device
  • SolaHD SDN-D rail power supply
  • OMRON C200H PLC Troubleshooting and Programming Essentials
  • Allen Bradley 1336 PLUS Inverter Practical Guide
  • OMRON 3G3KV frequency converter
  • OMRON NSJ Integrated Controller
  • Megatiker M4 Circuit Breaker Maintenance
  • OMRON ZX laser sensor maintenance
  • Saia PCD1 Controller Maintenance Guide
  • OMRON NT Series HMI Replacement and Maintenance
  • Yaskawa F7 Driver Maintenance and Replacement
  • Rockwell 1494 switch selection replacement
  • Omron NA Series HMI Connection Guide
  • Eaton CV Series PLC System Upgrade and Diagnosis
  • Eaton XV-102 HMI Installation and Troubleshooting
  • Siemens SINUMERIK measurement cycle configuration
  • ELAU PacDrive C600 Controller Integration Guide
  • ELAU PacDrive SM Servo Motor Application and Maintenance Guide
  • Bently Nevada Orbit 60 System Upgrade and Troubleshooting Guide
  • YOKOGAWA STARDOM FCN-RTU Controller
  • Fireye InSight II Marine Flame Scanner
  • How to install ABB VSC vacuum contactor?
  • Rexroth Bosch Group VT2000 Proportional Amplifier
  • ALSTOM ALSPA series frequency converter
  • ABB SPACOM replaces REX615
  • Meggitt C327895 Gas Metering Valve Technology
  • Application of MOOG G77x servo valve
  • WOODWARD 2301E Digital Speed Controller
  • ABB UNITOL 1010/1020 AVR Compact IGBT Automatic Voltage Regulator
  • ABB UNITOL 6000 excitation system
  • Rexroth Bosch Group HNC100 Hydraulic Shaft Control
  • Lenze 8400 Inverter Debugging Guide
  • Panning Vacuum Sensor Maintenance Guide
  • SOGEVAC Rotary Disc Pump Maintenance Guide
  • THERMOVAC MEMS Vacuum Gauge Guide
  • TTR 101 Vacuum Gauge Troubleshooting Guide
  • Honeywell Beam Smoke Detector Guide
  • TURBOVAC Molecular Pump Maintenance Guide
  • Troubleshooting of Leuze electronic DDLS 200 optical transmission
  • Lam Harmonic Drive Quick Replacement Guide
  • LZS power replacement and troubleshooting
  • MTL2000 series isolation barrier
  • Temposonics GB Sensor
  • Temposonics R Series Magnetostrictive Displacement Sensor Depth
  • Original inventor of M ü ller Co ax AG coaxial valve
  • Murrelektronik Automation Solution Complete Solution
  • Nabtesco RV series high-precision gearbox
  • NACHI Robot Full Series
  • Electro hydraulic proportional directional flow valve
  • NEC FC-9801X Industrial Computer
  • Mark VIeS Security System