Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • Modicon AS-P890-000 Remote I/O Processor Power Supply
    ❤ Add to collection
  • Modicon AS-P890-000 Remote I/O Processor Power Supply

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥32536.00
      ¥35237.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:12.530KG
    • Quantity:
    • (Inventory: 3275)
Description
<span style="font-size: 18px; font-family: arial;">Modicon AS-P890-000 Remote I/O Processor Power Supply</span>

Schneider Modicon AS-P890-000 Remote I/O Processor Power Supply

The Schneider Modicon AS-P890-000 is a remote I/O processor power supply module for the Modicon Quantum 800 series programmable logic controller platform. This module provides stable 24 V DC power to remote I/O modules, enabling distributed I/O configurations while providing electrical isolation between the master PLC and remote I/O for enhanced system reliability. The AS-P890-000 is designed for use in distributed I/O systems where I/O modules need to be placed at a distance from the main controller, reducing wiring and improving system flexibility. With a wide input voltage range of 90‑264 V AC and a high output efficiency of 96%, this power supply is suitable for industrial environments requiring stable and efficient power delivery.

Technical Specifications

Input voltage range: 90‑264 V AC (universal input). Output voltage: 24 V DC regulated. Output power: 1000 W. Output current capacity: 50 A. Efficiency: 96% (typical). Interfaces: supports multiple industrial communication protocols including Modbus and Ethernet for integration with other devices. Compatibility: compatible with Modicon 800 series I/O and PLC systems. Protection functions: overload protection, short-circuit protection. Operating temperature range: -20°C to +50°C. Protection class: IP20. Dimensions: 100 mm × 40 mm × 70 mm. Certifications: CE, UL. The module is designed for installation in a control cabinet. It provides stable 24 V DC power to remote I/O modules, supporting I/O expansion and signal isolation.

Key Features

  • 90-264 V AC universal input for global compatibility

  • 24 V DC output at 1000 W (50 A capacity)

  • 96% efficiency for reduced energy consumption and heat dissipation

  • Remote I/O processor functionality for Modicon 800 series

  • Provides electrical isolation between master PLC and remote I/O

  • Supports multiple industrial communication protocols (Modbus, Ethernet)

  • Wide operating temperature range (-20°C to +50°C)

  • Overload and short-circuit protection

  • Compact dimensions (100 mm × 40 mm × 70 mm)


Function in Modicon Quantum 800 Systems

The AS-P890-000 serves as a remote I/O adapter and power supply module for the Modicon Quantum 800 series. It provides stable 24 V DC power to remote I/O modules connected to it, enabling distributed I/O configurations where I/O modules can be located farther from the main controller. This reduces cabling costs and improves system flexibility. The module also provides electrical isolation between the master PLC and remote I/O, protecting the main controller from field wiring faults and improving overall system reliability. In distributed I/O systems, the AS-P890-000 can be placed at remote locations, providing local power supply to I/O modules and reducing the need for long power cables.

Integration with Quantum Series

The AS-P890-000 is fully compatible with Modicon Quantum 800 series I/O modules and PLCs. It integrates seamlessly into existing Quantum architectures, allowing engineers to expand I/O capacity without replacing the main controller. The module supports communication protocols including Modbus and Ethernet, ensuring smooth connection with other devices and systems. This improves system interoperability and allows the module to be used in a wide range of industrial automation applications. The user‑friendly programming environment allows easy parameter setting, control logic writing, and system debugging.

Applications

The AS-P890-000 is used in industrial automation applications requiring distributed I/O configurations, such as manufacturing lines (connecting various sensors and actuators on the production line to the central control system), energy sector monitoring and control of power generation and distribution systems, automation control integration of different devices and systems to achieve seamless operation, and harsh environment installations where electromagnetic interference is high. The module is suitable for industries including manufacturing, energy, oil and gas, water treatment, and general automation.


Installation and Wiring

Mount the AS-P890-000 on a DIN rail or panel inside a control cabinet. Connect the AC input (90‑264 V AC) to the line (L) and neutral (N) terminals. Connect the ground terminal (PE) to the cabinet ground. Connect the 24 V DC output to the remote I/O modules’ power supply terminals. Use appropriate wire sizes for the 50 A output capacity. The module supports overcurrent and short-circuit protection; external fuses are not required but may be added for additional protection. Ensure adequate clearance for heat dissipation; the 96% efficiency minimizes heat generation, but proper ventilation is still recommended.

Maintenance and Diagnostics

The AS-P890-000 has LED indicators for power and fault status. If the output voltage is within specification, the green LED illuminates. A red LED indicates a fault condition (overload, short circuit, or over-temperature). The module’s status can be monitored via the communication interface or through the main PLC’s diagnostic system. No routine maintenance is required. Replace the module if the output fails.

Conclusion

The Schneider Modicon AS-P890-000 remote I/O processor power supply module provides reliable, efficient power distribution for Modicon Quantum 800 series distributed I/O systems. Its 96% efficiency, 1000 W capacity, and wide input range make it a suitable choice for industrial automation applications requiring remote I/O expansion.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • KUKA QUANTEC-2 HO Maintenance Guide
  • KUKA KR QUANTEC-2 HC Maintenance and Rescue Guide
  • KUKA KR QUANTEC-2 Maintenance Troubleshooting Guide
  • KUKA KR QUANTEC PA series heavy-duty palletizing robot
  • KUKA KR IONTEC-2 Debugging and Maintenance Guide
  • KUKA KR IONTEC ultra series six axis heavy-duty industrial robot
  • KUKA KR IONTEC HO Maintenance Troubleshooting Guide
  • KUKA KR CYBERTECH-3 HW maintenance troubleshooting
  • KUKA KR CYBERTECH-3 maintenance troubleshooting
  • KUKA KR8 R2100-2 arc HW maintenance troubleshooting
  • KUKA KR CYBERTECH nano-2 maintenance troubleshooting
  • KUKA KR 20 R1810 HO maintenance troubleshooting
  • KUKA CYBERTECH maintenance troubleshooting
  • KUKA KR CYBERTECH CR maintenance troubleshooting
  • KUKA KR AGILUS-3 ultra maintenance troubleshooting
  • KUKA KR 300 R2700-2 C-F maintenance troubleshooting
  • KUKA KR 20 R1820-2 E Maintenance Troubleshooting and Replacement Practice
  • KUKA AGILUS-3 troubleshooting
  • KUKA KR AGILUS-2 maintenance troubleshooting
  • KUKA KR 1000 titan PA troubleshooting
  • KUKA KR 700 PA maintenance troubleshooting
  • KUKA KR18 R1450-3 PP Operation and Maintenance Essentials
  • KUKA KR12 SCARA Operations Essentials
  • KUKA KR4 R600 Operation and Maintenance Essentials
  • KUKA KR 3 AGILUS Operation and Maintenance Safety Essentials
  • KUKA LBR iiwa CR Cleanroom Troubleshooting and Maintenance
  • Troubleshooting and Maintenance of KUKA KR AGILUS sixx
  • KUKA KR60 SCARA CS Maintenance Guide
  • KUKA KR 23 SCARA-2 Robot Installation and Maintenance Detailed Explanation
  • KUKA KR 20 SCARA CS Robot Selection and Maintenance Guide
  • KUKA KR 15 DELTA-2 Robot Installation and Maintenance
  • KUKA KR 13 SCARA-2 CS Detailed Explanation
  • KUKA KR 3 D1200 Robot Operation and Maintenance
  • KUKA KR 3 D1200 HM Robot Operation and Maintenance Guide
  • KUKA LBR Med Medical Robot Integration Guide
  • KUKA iiwa Robot Safety Operation and Maintenance
  • KUKA LBR iiwa CR Operations and Troubleshooting
  • Lauer PCS Series Operation Console Configuration Guide
  • Installation and Maintenance Guide for KUKA LBR iisy Series Collaborative Robots
  • KUKA LBR iisy 3 R760 Collaborative Robot Debugging Guide
  • KUKA LBR iico Robot Installation and Debugging Technical Guide
  • Lauer Starline LCA 300/320/325 Text Display Application Guide
  • Lauer PCS 950 Operation Console Application Guide
  • Lauer EPC series industrial computer configuration
  • Bonfiglioli Precision Planetary Gearbox Selection and Application Guide
  • Installation and heat dissipation of Bonfiglioli Vectron cold plate frequency converter
  • Bonfiglioli Vectron EM-RES-02 Expansion Module Installation and Configuration Guide
  • Bonfiglioli Vectron EM-RES-01 Expansion Module Rotary Transformer Interface Configuration Guide
  • Bonfiglioli Vectron EM-IO-04 module KTY temperature measurement and digital port configuration
  • Bonfiglioli Vectron EM-IO-03 Expansion Module Dual Analog Output and PTC Configuration
  • Installation of Bonfiglioli Vectron EM-IO-02 Expansion Module and PTC Temperature Monitoring Configuration
  • Bonfiglioli Vectron EM-IO-01 Expansion Module Installation and System Bus Configuration Guide
  • Bonfiglioli F series gearbox spare parts identification and replacement guide
  • Installation, maintenance, and troubleshooting of Bonfiglioli HF series reducers for hoisting applications
  • Bonfiglioli 300 series reducer installation, maintenance, and troubleshooting guide
  • Selection and integration guide for Bonfiglioli R3 series planetary gearboxes in primary crushing equipment
  • Bonfiglioli C-series ATEX gearbox selection and explosion-proof application guide
  • Bonfiglioli Vectron EM-ENC-05 Full Function Expansion Module Integration Guide
  • Bonfiglioli Vectron EM-ENC-04 Multi functional Expansion Module Complete Configuration Guide
  • Bonfiglioli Vectron EM-ENC-03 Second Encoder Interface and System Bus Expansion Guide
  • Bonfiglioli Vectron EM-ENC-02 Expansion Module Integration and Encoder Interface Guide
  • Bonfiglioli Vectron CM-CAN CANopen Communication Configuration and DS402 Control Guide
  • Bonfiglioli Vectron EM-SYS System Bus Networking and Virtual Link Configuration Guide
  • Bonfiglioli Vectron CM-PDP Profibus DP Configuration and Debugging Guide
  • Bonfiglioli Vectron CM-232/485 Modbus Communication Configuration Guide
  • Bonfiglioli BMS series servo reduction motor selection and integration guide
  • Bonfiglioli ACTION 210/410 Inverter Debugging and Fault Diagnosis Complete Guide
  • Honeywell Enhanced Micro TDC 3000X System Redundancy Architecture and Maintenance Guide
  • Selection and Configuration of Bonfiglioli Active Series Inverter
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli HDP/HDO Series Heavy duty Gearboxes
  • Installation, Maintenance, and Troubleshooting Guide for Bonfiglioli 300/300M Series Gearboxes
  • Bonfiglioli 300M planetary gearbox selection and thermal verification guide
  • Bonfiglioli 3/H series heavy-duty gearbox selection and verification guide
  • Bonfiglioli KRG/KCG/KSD Hydraulic Coupling Selection and Integration Guide
  • Bonfiglioli BTD/BCR Servo Motor System Integration and Interface Configuration Guide
  • Bonfiglioli BTD/BCR Synchronous Servo Motor Selection and Interface Configuration Guide
  • Bonfiglioli VF-W series ATEX explosion-proof reducer selection guide
  • Bonfiglioli EM-ENC-03 Expansion Module Configuration and System Bus Integration Guide
  • Bonfiglioli EVOX CP Explosion proof Reducer: Quick Guide for Installation and Maintenance
  • Bonfiglioli C/A/F/S Reducer ATEX Installation and Maintenance Practice Guide
  • Bonfiglioli BXN/MXN Motor Installation and Brake Maintenance Complete Guide
  • Bonfiglioli VF-W IE2/IE3 Worm Gear Reducer: Energy Efficiency Selection and Application Practice Guide
  • Bonfiglioli VF-W Explosion proof Worm Gear Reducer: ATEX Selection and Installation Complete Guide
  • Selection and Calculation of Bonfiglioli RAN Right Angle Gearbox
  • Bonfiglioli Industrial Transmission System Selection Guide
  • Bonfiglioli EVOX Gearmotor Selection and Configuration Guide
  • Bonfiglioli CAFS Reducer Selection and Application Guide
  • Bonfiglioli C-A-F gearbox selection and maintenance
  • Bonfiglioli C Series ATEX Explosion proof Reducer Selection
  • Bonfiglioli BN-BE-BX Series Motor Selection Guide
  • Bonfiglioli BMD Servo Motor Selection and Configuration Guide
  • Selection of Bonfiglioli A-series servo reducer
  • Bonfiglioli AS Series Reducer Installation and Maintenance Guide
  • Bonfiglioli Active 401/201 Inverter Selection and Application Guide
  • Bonfiglioli EM-IO-04 Expansion Module Configuration Guide
  • Bonfiglioli EM-ENC-02 Expansion Module Engineering Configuration Guide
  • Bonfiglioli A-series gearbox selection and maintenance
  • Bonfiglioli Transmission and Automation Product Selection Reference
  • Bonfiglioli RAN series bevel gearbox selection and maintenance guide
  • Bonfiglioli ACTION 401/201 Inverter Engineering Integration Guide
  • Alcatel Lucent Stellar AP1301 Deployment and Performance Optimization
  • Alcatel Lucent ALE Wireless Handheld System Selection and Deployment Guide
  • In depth analysis of Alcatel Lucent MDR-8000 microwave system engineering technology
  • Alcatel 1660SM Multi Service Node Operations and Troubleshooting
  • Alcatel Lucent OmniSwitch 6850 Stacking and Security Configuration Guide
  • Alcatel Lucent 7750 SR Router High Availability Deployment and Troubleshooting
  • Alcatel 1600 Series SDH Equipment Operation and Maintenance Guide
  • Alcatel Lucent 9500 MPR Microwave Platform Deployment and Troubleshooting
  • Alcatel Lucent 7450 ESS High Availability Deployment and Operations Guide
  • Alcatel OmniPCX 4400 REFLEXES Phone Configuration Troubleshooting
  • Alcatel Lucent OmniSwitch 6850E Stacking Operations and Troubleshooting
  • Alcatel Lucent OmniSwitch 6450 Stacking and Troubleshooting Guide
  • Lucent Stinger DSLAM High Availability Deployment and Fault Recovery Complete Guide
  • Alcatel Lucent 1660SM Optical Transmission System Architecture and Business Bearer
  • ALCATEL-LUCENT 9500 MPR Microwave Packet Wireless System Performance
  • Atlas Copco MT Focus 6000 Controller Safety Specification and Electrical Grounding
  • Atlas Copco Power MACS 4000 Automated Tightening System Performance
  • Design and Protection of Constant Torque Application for Atlas Copco Neos Inverter
  • Atlas Copco Power Focus 8 Family Selection Configuration and Virtual Station Function Complete Explanation
  • Atlas Copco Power Focus 4000 Controller Safety Deployment and Electrical Grounding Specification
  • Atlas Copco Power Focus 3000 Controller Installation, Debugging, and Troubleshooting Guide
  • Atlas Copco Tensor S Tightening Tool Troubleshooting Guide
  • Application and maintenance of Atlas Copco SRTT-B torque sensor
  • Atlas Copco ACTA 4000 Torque Analyzer Operation and Calibration Guide
  • Atlas Copco Tensor STB Wireless Tightening Tool Deployment Guide
  • Atlas Copco Power Focus 4000 Configuration and Troubleshooting Manual
  • Atlas Copco Power Focus 6000 and Tensor STR System
  • Energy efficiency and selection of Atlas Copco ZR/ZT oil-free screw compressor