Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • Bosch Rexroth R185321310 Runner Block
    ❤ Add to collection
  • Bosch Rexroth R185321310 Runner Block

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥15237.00
      ¥16632.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:1.534KG
    • Quantity:
    • (Inventory: 154)
Description
<span style="font-size: 18px; font-family: arial;">Bosch Rexroth R185321310 Runner Block</span>

Bosch Rexroth R185321310 Runner Block

A technical overview of the Bosch Rexroth R185321310 runner block, type RWA-025-FLS-C1-H-2, for ball rail linear guide systems.

The Bosch Rexroth R185321310 is a runner block for ball rail linear guide systems, identified by the type designation RWA-025-FLS-C1-H-2. The designation describes the block size, the flange or slim line body style, the sealing arrangement, the preload class, and the connection variant used in the linear guide assembly. The runner block travels along the guide rail and carries the moving machine component, transferring load through recirculating rolling elements.

This article provides a technical introduction for machine designers, assembly technicians, commissioning teams, and maintenance personnel. It describes the function of the runner block in a linear axis, rail and block matching, mounting practice, alignment, lubrication, sealing, diagnostics, and long term care. Exact load ratings, preload data, permissible speeds, lubrication quantities, and environmental limits must be confirmed with the product documentation for this runner block type.

Function in the Linear Guide System

A runner block converts the relative motion between the moving machine part and the fixed machine base into low friction linear travel. Inside the block, rolling elements circulate in load carrying and return channels. The rolling contact supports radial, axial, and moment loads depending on the block type and the rail arrangement. The result is a stiff, repeatable guide that supports accurate positioning in machine tools, handling systems, and production equipment.

The type designation RWA-025-FLS-C1-H-2 indicates a size 25 block with a defined body style, sealing concept, and preload. The block must be matched to the corresponding rail size and rail accuracy class. A block and rail from the same size family form the functional unit. Mixing components from different sizes or accuracy classes should be avoided unless the system design explicitly allows it.

Mounting and Alignment

Mounting begins with a clean assembly area. The rail should be installed and aligned according to the machine drawing, and the reference edge should be used for positioning. The runner block should be placed on the rail using the supplied insertion aid or a dummy rail so that the rolling elements are not displaced. Screws should be tightened in a defined sequence and to the specified torque.

Alignment of parallel rails influences running smoothness and service life. Height and lateral offset between rails should be checked with appropriate measuring equipment. A guide system that is forced into position can show increased friction, noise, and uneven wear. The moving structure should also be checked for squareness so that the block is not loaded by distortion of the machine frame.

Lubrication and Sealing

Lubrication reduces friction and protects the rolling contact surfaces. The lubricant type and quantity depend on the load, speed, stroke, and environment of the application. Initial lubrication should be applied according to the assembly instructions, and the relubrication interval should be defined from the operating conditions. In dirty environments the interval may need to be shortened.

The sealing arrangement of the block protects the rolling elements from dust, chips, and coolant. The sealing concept of the RWA type includes wiper elements that clean the rail as the block moves. If wipers are damaged or worn, contamination can enter the block and shorten service life. Additional protection such as bellows or covers should be considered where heavy contamination is expected.


Commissioning Checks

After assembly, the axis should be moved by hand over the full stroke where possible. The travel should be smooth without binding, knocking, or noticeable resistance changes. Any abnormal noise should be investigated before the axis is powered. The mounting screws of the rail and the block should be checked for correct torque, and the lubrication state should be confirmed.

During the first powered movements, the axis should run at reduced speed. Motor current, temperature, and vibration should be observed. If the axis shows high friction or uneven motion, the alignment and the mounting surfaces should be reviewed before the application parameters are changed. Commissioning records should note the lubricant used and the initial settings.

Diagnostics and Maintenance

Wear indicators for a linear guide include increasing friction, noise, backlash, and visible lubricant condition changes. Loose mounting screws, damaged wipers, insufficient lubricant, and contamination are frequent causes of poor running behavior. Maintenance personnel should inspect the rail surface for scoring and the block for seal damage at defined intervals.

Relubrication should be performed with the specified lubricant and quantity. Mixing incompatible lubricants should be avoided. If a block has to be replaced, the rail should be checked for damage and cleaned before a new block is installed. The replacement block should match the original type designation and preload class so that the axis behavior remains consistent.

Application Planning Notes

The Bosch Rexroth R185321310 runner block, type RWA-025-FLS-C1-H-2, is intended for machine axes that require precise linear guidance with defined preload and sealing. Project planning should confirm load direction, load magnitude, stroke length, speed, acceleration, mounting arrangement, and environmental conditions. The rail, block, lubrication concept, and protection measures should be planned as one system. For exact technical data and approved application conditions, the product documentation for this runner block should be used as the final reference.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Yokogawa AIP830 Single Circuit Operation Keyboard
  • Yokogawa RAMC flowmeter selection and troubleshooting
  • YASKAWA GA500 frequency converter troubleshooting
  • TRACO TIS600 power supply
  • Sigmatek ETV-0851 Control Panel Troubleshooting
  • Allen Bradley Quest AN-X2-AB-DHRIO Remote I/O Adapter Integration and Troubleshooting
  • Meggitt RPS6U power supply
  • Kongsberg RCU500 Controller Integration and Fault Diagnosis Guide
  • KBAC series frequency converter installation and fault diagnosis guide
  • EXOR effectiveness View eV058 series HMI industrial panel
  • Emerson OCR3000 Controller Troubleshooting Guide
  • Emerson Ovation OCR1100 Controller Maintenance and Troubleshooting
  • Elmo G-TUB30 Driver Troubleshooting Guide
  • Troubleshooting and Optimization of Basler A400 Series Camera
  • Troubleshooting and Maintenance of Automated Logic I/O Expansion Module
  • Troubleshooting and Maintenance of Aerotech UNIDEX 100 Controller
  • ADVANEST R6144 calibration source troubleshooting
  • Troubleshooting and Calibration of ABB Millmate Tension Gauge
  • ABB NGC8206 natural gas chromatograph troubleshooting and maintenance
  • ABB AO2040-CU Ex Explosion proof Analyzer Troubleshooting
  • ABB PFEA113 Tension Controller Troubleshooting Guide
  • ABB PFEA111/112/122 Tension Controller Troubleshooting Guide
  • ABB LS4000 laser analyzer
  • ABB SPAU 341 C Voltage Regulator Troubleshooting Guide
  • Analysis and Fault Diagnosis of ABB V-Contact VSC Medium Voltage Contactor
  • ABB UNITOL 1020 Compact Digital Excitation Regulator AVR Replacement and Troubleshooting
  • ABB UNITROL 1000 excitation system replacement and troubleshooting
  • ABB SYNC HROTACT 5 synchronization module troubleshooting and replacement
  • ABB SYNC HROTACT 5 Synchronization Device Replacement and Troubleshooting Guide
  • ABB Symphony Plus Module Replacement and Upgrade Guide
  • ABB S900 I/O Hazardous Area Deployment and Maintenance
  • ABB System 800xA Operations and Troubleshooting
  • ABB PCS6000 Troubleshooting and Module Replacement Guide
  • ABB PCS 8000 pumped storage excitation
  • ABB Procontrol P13 Bus Coupling Upgrade Guide
  • ABB NextMove ESB-2 Fault Diagnosis and Configuration Practice
  • ABB MEGADRIVE-LCI Maintenance and Selection Practice
  • ABB MEGADRIVE LCI Transmission Vibration Suppression
  • ABB MEGADRIVE LCI Water Cooling Troubleshooting and Maintenance Guide
  • Practical Maintenance and Common Troubleshooting of ABB DCS880
  • ABB SDCS-IOB-3 Replacement and Troubleshooting
  • ALSTOM MAE99-04 Serial Interface Terminal Panel Maintenance and Troubleshooting
  • Installation and Maintenance of ALSTOM ALSPA MV3000 Handheld Operator
  • Maintenance and commissioning of ABB KPM KB2 paper breakage detector
  • Maintenance and troubleshooting of ABB SCC-K converter
  • ABB SCC Gas Preprocessing System Maintenance and Selection Guide
  • ABB NGC8209 gas chromatograph maintenance
  • Maintenance and troubleshooting of ABB DCS DC speed controller
  • ABB ASTAT Crane Controller Maintenance and Debugging Guide
  • ABB ACS800 TIM foil IGBT
  • ABB LS25 laser analyzer troubleshooting
  • ABB REM54 motor terminal troubleshooting
  • ABB REL670 distance protection and troubleshooting
  • ABB SUE3000 switching device troubleshooting
  • ABB REF630 feeder protection
  • ABB REF620 (Relion 620 series) feeder protection and measurement device
  • ABB E1B-A Circuit Breaker
  • ABB FCU400-IR temperature measurement system troubleshooting
  • ABB TZIDC-200 locator configuration and troubleshooting
  • ABB DHH805-A Handheld Operator Configuration and Activation Guide
  • ABB SACO 16D1 alarm device replacement and troubleshooting
  • ABB 5SHY3545L0016 IGCT module replacement guide
  • ABB S600 I/O Module Replacement and Troubleshooting Guide
  • ABB NextMove e100 motion controller troubleshooting guide
  • Rockwell PowerFlex 700 Inverter Replacement and Troubleshooting Guide
  • Allen Bradley 1762-OW16 Output Module
  • Allen Bradley IntelliVAC 1503VC Series E Control Module
  • Allen‑Bradley IntelliVAC ™ 1503VC contactor control module
  • Woodward SOGAV 250 solenoid valve drives gas intake valve for troubleshooting
  • Woodward easyYgen-3500XT-P1 obstacle removal
  • Woodward CPC-II electro-hydraulic current pressure converter
  • UniOP ePALM10 Handheld HMI
  • TMEIC TMdrive-30 frequency converter
  • TEWS TVME200 Carrier Board Configuration and Troubleshooting Guide
  • TDK Alpha 400 Power Troubleshooting Guide
  • STUCKE SYMAP relay
  • Deployment and troubleshooting of Softing CAN-AC2-PCI interface card
  • Installation, Maintenance, and Troubleshooting of Siemens C7-623/624
  • Foxboro Compact 200 Series 16 Slot Bottom Plate Deployment and Maintenance Guide
  • Foxboro 84F/84W Vortex Flow Meter Selection and Debugging Guide
  • Foxboro E69F Converter
  • Foxboro DCS Compact200 series RH916RB (16 slot horizontal bottom plate)
  • Reliability Electric PSC7000 Control Card Troubleshooting and Maintenance
  • Eaton MTL F809F Plus DTM Operating Instructions
  • Motorola ACE3600 RTU Troubleshooting Guide
  • MOOG D136-003-001 on-site deployment and troubleshooting
  • Troubleshooting and Maintenance of Micro Panel GF1-10 Touchscreen
  • Neles NDX Intelligent Valve Positioner Troubleshooting and Debugging
  • Jamesbury VPVL Mod D Maintenance and Troubleshooting
  • Jamesbury VPVL Pneumatic actuator selection and maintenance guide
  • GMW IPP 144-40 GS Thermal Printer Troubleshooting Guide
  • Meggitt C327845 Gas Shutoff Valve Troubleshooting and Replacement Guide
  • Meggitt C422685 Gas Solenoid Valve Troubleshooting Guide
  • LTI ServoOne Servo Troubleshooting Guide
  • Jenaer Antriebstechnik ECOVARIO Servo Troubleshooting Guide
  • Honeywell TDC3000X Troubleshooting Guide
  • Honeywell NOTIFIER NFS2-3030 Troubleshooting Guide
  • Troubleshooting of Honeywell FC series safety barriers
  • Honeywell XL1404 Troubleshooting Guide
  • Honeywell TDC 3000 Troubleshooting and Module Replacement Guide
  • HIMA X-DI 64 01 Safety Module
  • Hirschmann MICE MS20/MS30 Switch Integration and Troubleshooting
  • EXOR ePAD05/ePAD06 button screen replacement and troubleshooting
  • EXOR eVO58-TST/TNT Compact HMI Human Machine Panel
  • Esd VME-PCM-CADDY/2 Carrier Board Integration and Troubleshooting Guide
  • Elmo Gold Tuba Servo Drive Integration and Troubleshooting Guide
  • Eaton COM-MPB1-TP/MPB2-TP communication module
  • DeltaTau PMAC2 PCI Ultralite Programmable Multi Axis Motion Controller
  • DATA PATTERNS DP-VME-5114 Dual PMC Carrier Board Integration and Troubleshooting
  • CMZ SVM1608 Intelligent Servo Driver
  • SUMITOMO T2100Z steel turning selection and troubleshooting
  • SUMITOMO PSZ Turn Quick Change System Selection and Troubleshooting
  • SUMITOMO EGU chip breaker selection and troubleshooting
  • SUMITOMO GND slotting tool holder selection and troubleshooting
  • SUMITOMO AC8000P steel turning selection and troubleshooting
  • SUMITOMO AC6000M Stainless Steel Turning Guide
  • SUMITOMO ELECTRIC AC5000S Heat Resistant Alloy Turning Guide
  • SUMITOMO ELECTRIC AC4000K Cast Iron Turning Selection Guide
  • SUMITOMO ELECTRIC AC1135U Small Parts Turning Application Guide
  • SUMITOMO ELECTRIC AC1030U Precision Machining Selection and Practice for Small Parts
  • CCS 6900G/P pressure switch
  • BENDER WR Transformer Selection
  • BENDER RCMA475LY Residual Current Monitoring
  • BENDER IRDH575 Insulation Monitoring
  • BENDER IRDH265 Insulation Monitoring and Debugging
  • Bender RCMA475LY residual current monitor debugging
  • Beckwith Electric M-3425A Generator Protection Relay Debugging Guide
  • Automated MEX816U Expander Troubleshooting Guide