Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • OMRON C200PC-ISA02-DRM-E SYSMAC Board PLC with Floppy & Operator Panel
    ❤ Add to collection
  • OMRON C200PC-ISA02-DRM-E SYSMAC Board PLC with Floppy & Operator Panel

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥65738.00
      ¥68957.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:5.560KG
    • Quantity:
    • (Inventory: 7648)
Description

OMRON C200PC-ISA02-DRM-E SYSMAC Board PLC with Floppy and Operator Panel

The OMRON C200PC-ISA02-DRM-E is a SYSMAC Board Programmable Logic Controller designed for integration into PC-based industrial automation systems. This ISA bus-compatible board delivers full functionality equivalent to standalone C200HX, C200HG, and C200HE PLC families, transforming a standard personal computer into a powerful industrial controller. The complete package includes the SYSMAC Board PLC, programming floppy disk containing support software, C200H-CN222 programming cable, and C200H-PRO27-E operator panel for comprehensive system programming and monitoring.

Product Overview

The C200PC-ISA02-DRM-E mounts directly onto a PC motherboard via the ISA expansion slot, providing a compact and efficient solution for machine control, data acquisition, and system monitoring applications without requiring separate PLC hardware cabinets. The SYSMAC Board series is manufactured for use according to proper procedures by qualified operators and only for the purposes described in the official product documentation. This board includes comprehensive safety precautions and operational guidelines to ensure reliable performance in industrial environments, including danger, warning, and caution indicators for various operational scenarios.

The SYSMAC Board supports the CX-Programmer software environment, providing a familiar programming interface for users experienced with OMRON PLC systems. The board can be programmed and monitored using either the included operator panel or the CX-Programmer software running on the host PC, offering flexible configuration options for different maintenance and programming scenarios.


Technical Specifications

ParameterSpecification
ModelC200PC-ISA02-DRM-E
Bus InterfaceISA Bus Compatible
Equivalent PLC SeriesSYSMAC C200HX/C200HG/C200HE
Unit Number Range0 to 9 (decimal)
Factory Default Unit Number0
CompoBus/D Baud Rate125 kbps, 250 kbps, 500 kbps selectable

The unit number configuration determines which memory words in the PLC system are allocated for the board operation, allowing multiple boards to coexist in a single system with proper address allocation. The CompoBus/D communications DIP switch is used to set the communications baud rate and to determine whether communications will continue or stop when a communications error occurs. The baud rate must be set identically on all nodes in the network, as any slaves with baud rates different from the master rate will not be able to participate in communications.

Included Floppy Disk Programming Software

The package includes a floppy disk containing the necessary support software for programming and configuring the C200PC-ISA02-DRM-E SYSMAC Board. This floppy disk stores essential information such as user programs, I/O tables, and system configuration data. The data disk is intended for use in the appropriate floppy disk drive of the programming computer. The floppy disk interface enables users to back up and restore PLC programs, transfer configuration settings between systems, and maintain version control of control logic across multiple installations.

Programs can be output directly to the floppy disk drive, providing convenient storage and transfer of control applications. The floppy disk medium serves as a reliable method for program archiving and system replication, particularly useful in distributed manufacturing environments where multiple identical control systems require the same program logic.

C200H-CN222 Programming Cable

The C200H-CN222 programming cable is specifically designed for connecting the SYSMAC Board or C200H series PLC to a programming device such as a personal computer running CX-Programmer or SYSMAC Support Software. This cable provides the physical interface between the PLC peripheral port and the computer serial communication port, enabling program transfer, online monitoring, and system debugging operations.

For connection of a PC with the SYSMAC board built into the computer where CX-Programmer is installed, the appropriate programming cable ensures reliable communication between the programming software and the board. When using the operator panel for direct programming and monitoring, the cable connection may be configured differently depending on the specific hardware setup. Proper cable selection and pin configuration are essential for establishing stable communication between the programming device and the SYSMAC Board.

C200H-PRO27-E Operator Panel

The C200H-PRO27-E is a handheld programming console designed for direct interaction with OMRON C200H series PLCs and SYSMAC Boards. This operator panel provides a compact, portable interface for programming, monitoring, and troubleshooting control systems without requiring a personal computer. The PRO27 features a liquid crystal display for viewing program instructions, timer and counter values, and data memory contents, along with a full alphanumeric keyboard for entering ladder diagram instructions and modifying system parameters.

The operator panel connects directly to the peripheral port of the SYSMAC Board, enabling on-site programming and maintenance. Key functions include online program editing, forced set/reset of I/O bits, monitoring of contact and coil status, timer and counter value adjustment, data memory read/write operations, and error log viewing. The handheld console is particularly valuable for field technicians performing maintenance on installed equipment where a personal computer may not be readily available or practical to connect.


CompoBus/D Master Functionality

The C200PC-ISA02-DRM-E includes integrated CompoBus/D Master capability, providing DeviceNet-compatible network connectivity for distributed I/O and device control. The CompoBus/D Master unit number is set using a rotary switch on the board, with unit numbers used to differentiate Special I/O Units mounted to the same PLC system, including those mounted to Expansion I/O Racks. Any available unit number can be set as long as it has not been assigned to another Special I/O Unit within the SYSMAC Board system.

The CompoBus/D communications DIP switch configures the network baud rate and error handling behavior. Pin 4 is reserved and must always be set to OFF. Pins 1 and 2 select the baud rate, with factory default setting of OFF, OFF providing 125 kbps communication speed. Higher speeds of 250 kbps and 500 kbps are available for applications requiring faster data exchange. If the same unit number is used for more than one unit, a duplicate number error will occur and the SYSMAC Board will not start properly.

CX-Programmer Software Compatibility

The CX-Programmer software, part of the CX-One automation suite, is fully compatible with the C200PC-ISA02-DRM-E SYSMAC Board. CX-Programmer Versions 3.0 and higher operate on Windows 95, Windows 98, Windows NT 4.0, Windows Me, Windows 2000, and Windows XP operating systems. The software provides a Windows-based programming environment for developing ladder diagram logic, configuring system parameters, and monitoring real-time PLC operation.

After selecting the PLC series in CX-Programmer, the correct CPU type corresponding to the SYSMAC Board must be selected to establish proper communication. The PLC icon in the workspace tree can be double-clicked to access device type settings. By pressing the Settings button next to the selected PLC and clicking in the dialogue box, the CPU type selection can be changed. Proper CPU type selection is essential for successful connection, as CX-Programmer will display an error message if the selected CPU type does not match the actual hardware configuration.


Applications and Use Cases

The complete C200PC-ISA02-DRM-E package with floppy disk, programming cable, and operator panel provides a comprehensive solution for PC-based industrial control applications. Typical applications include machine automation in manufacturing facilities, process control monitoring for chemical and pharmaceutical production, data acquisition systems for quality assurance testing, test equipment control in laboratory environments, and industrial workstations requiring direct PLC functionality without dedicated PLC hardware.

The SYSMAC Board is ideally suited for OEM equipment manufacturers integrating control systems into specialized machinery, system integrators developing custom automation solutions, maintenance departments requiring portable programming capabilities for field service, and educational institutions teaching programmable logic controller programming and industrial automation concepts. The included operator panel provides immediate access for on-site adjustments, while the floppy disk software enables program backup and system replication across multiple installations.

Installation and Configuration

Installation of the C200PC-ISA02-DRM-E requires inserting the board into an available ISA expansion slot on the host PC motherboard. The unit number must be configured before operation using the selector switch on the board, with each unique number corresponding to specific memory allocations within the PLC system. When multiple boards are installed, each must be assigned a distinct unit number to avoid address conflicts. The CompoBus/D communications DIP switch must be configured for the appropriate baud rate and error handling behavior based on the network requirements.

The included programming floppy disk contains the support software needed to initialize the board and establish communication with the programming environment. After software installation, the C200H-CN222 cable connects the SYSMAC Board peripheral port to the computer serial port, enabling program download and online monitoring. The C200H-PRO27-E operator panel can be connected as an alternative programming and monitoring device for field maintenance and troubleshooting without requiring a personal computer.

Environmental and Operational Requirements

Like all OMRON industrial control products, the C200PC-ISA02-DRM-E is designed for reliable operation in manufacturing and industrial environments. Proper installation, adequate ventilation, and adherence to specified electrical requirements are essential for optimal performance. The board incorporates protective features to safeguard against electrical interference and transient voltages common in industrial settings. The floppy disk media should be stored in clean, dry conditions away from magnetic fields and extreme temperatures to ensure data integrity and reliable program storage.

The operator panel is designed for handheld use in industrial environments, with a rugged construction that withstands typical field service conditions. The programming cable should be handled with care to prevent damage to connectors and conductors. All components of the SYSMAC Board system should be installed and operated by qualified personnel familiar with programmable controller systems and the specific safety precautions outlined in the product documentation.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ETEL DSCDP/DSCDL/DSCDM Dual Axis Controller Debugging Guide
  • ETEL DSCDL Dual Axis Controller Hardware Integration Guide
  • ETEL DSB2P Series Servo Amplifier Connection and Configuration Guide
  • ETEL DSC2P/DSC2V Servo Controller Debugging Guide
  • DFI HD636-H81CS Industrial Motherboard Deployment and Debugging
  • Integration and Optimization of ADLINK DAQ-20xx Synchronous Acquisition Card
  • ADLINK cPCI-6530 Core i7 Blade Computer Deployment Guide
  • ADLINK cPCI-3610 Blade Computer Integration and Debugging
  • ADLINK AMP-204C/208C Troubleshooting Guide
  • ADLINK AmITX ALN Industrial Motherboard Characteristics and Application Analysis
  • ADLINK NuPRO-850 Motherboard Installation and Configuration Guide
  • ADLINK MI-965 Motherboard Installation and BIOS Configuration Guide
  • ADLINK M-302 Industrial Motherboard Installation and BIOS Optimization Guide
  • ADLINK PXI-3920/3910 Controller Installation and Configuration Guide
  • ADLINK PCI-8132 Motion Control Card Installation, Programming, and Debugging Guide
  • ADLINK cPCI-6760D/P7/P8 Module Installation and Hot Plug Guide
  • ADLINK ACL-7122 Digital I/O Card Installation and Programming
  • ADLINK NuPRO-775 Industrial Motherboard Installation and BIOS Configuration Detailed Explanation
  • ETEL Accuret MODULAR 300/400/600 Controller Selection Guide
  • Edwards CTI Kryogenics On Board 8F Enhanced Cryopump Explanation
  • ADLINK PCI-9112 Multi functional Data Acquisition Card
  • ADLINK PCI-8102 Two Axis Pulse Motion Control Card
  • ADLINK PCI-9812/10 high-speed synchronous acquisition card
  • ADLINK PCI-7200 High Speed Digital I/O Card
  • ADLINK MXE-1000 series fanless industrial computer
  • ADLINK IMB-T10 Mini ITX Embedded Motherboard
  • ADLINK HSL-DO32-M-N/P distributed I/O module
  • ADLINK DAQ-2500 Series Multi Channel Analog Output Card
  • ADLINK DAQ-2200 Series Data Acquisition Card
  • ADLINK ETX-AT-N270 Embedded Module
  • ADLINK ACL-7225B Relay Isolation Input Card Guide
  • ADLINK DAQ-2000 Synchronous Sampling and Acquisition Card Selection Guide
  • ADLINK NuPRO-E330 Industrial Motherboard Selection and Deployment
  • ADLINK ACL-8112 Data Acquisition Card Configuration and Programming
  • ADLINK USB-2405 Dynamic Signal Acquisition Module Deployment Guide
  • ADLINK PXIS-3320 PXI chassis installation troubleshooting
  • ADLINK PCIe-GIE72/74 Image Acquisition Card Deployment Guide
  • ADLINK PCIe-7856/7853 Sports I/O Controller Card Guide
  • ADLINK PCI-6308 Isolation Output Card Programming and Installation
  • ADLINK PCI-7432 installation and configuration troubleshooting
  • adlink nupro-e72 التحكم الصناعي اللوحة
  • ADLINK NuPRO-E72 Industrial Control Motherboard
  • ADLINK MXE-5400 Industrial Control Computer
  • ADLINK M-322 Industrial Motherboard Configuration and Deployment Guide
  • ADLINK IMB-M43H Industrial Motherboard Configuration and 6th/7th Generation Core Deployment Guide
  • ADLINK IMB-M42H Industrial Motherboard Deployment and BIOS Optimization Guide
  • ADLINK i915GV-INA motherboard configuration and ISA compatibility tuning guide
  • ADLINK ETX-NR667 Core2 Duo Module Selection and Deployment
  • ADLINK ETX-BT Module Configuration and PATA to SATA Upgrade Guide
  • ADLINK CM1-BT1 Extreme Environment Deployment and Configuration
  • ADLINK cPCI-8217 VGA/LCD Module Configuration and Troubleshooting
  • ADLINK AmITX-SL-G Mini ITX Motherboard Deployment and SEMA Guide
  • ADLINK AmITX-AL-I Embedded Motherboard Deployment and SEMA Management Guide
  • ADLINK NuPRO-E315 PICMG 1.3 Industrial Motherboard Deployment Guide
  • ADLINK NuPRO-842 Pentium 4 Industrial Motherboard Deployment and Debugging Guide
  • ADLINK NuPRO-900A Dual Xeon ePCI-X Motherboard Deployment Guide
  • ADLINK cPCI-6910 Dual Core Xeon Single Board Computer Deployment Guide
  • ADLINK cPCI-6860A Dual Xeon Single Board Computer Deployment Guide
  • ADLINK CPCI-8168 Eight Axis Motion Control Card Deployment and HSL Integration Guide
  • ADLINK NuPRO-E340 Industrial Motherboard Debugging and BIOS Optimization Guide
  • ADLINK NuPRO-A40H Industrial Single Board Computer Hardware Deployment and BIOS Calibration Guide
  • ADLINK NuPRO-852 LGA775 Industrial Control Motherboard Maintenance Guide
  • ADLINK NuPRO-841 Industrial Motherboard Maintenance and Troubleshooting
  • ADLINK NuPRO-590 Series Socket7 Industrial Control Motherboard Maintenance Guide
  • Deployment and Troubleshooting of ADLINK MXE-5500 Series Industrial Control Computer
  • ADLINK MXE-200 Fanless Embedded Industrial Control Computer Deployment Guide
  • ADLINK cPCI-6770 Series CompactPCI Motherboard Maintenance Guide
  • ADLINK NuPRO-A301 Industrial Motherboard Troubleshooting Manual
  • ADLINK NuPRO-965 SHB Debugging and Maintenance Complete Manual
  • ADLINK NuPRO-935A Industrial Motherboard Debugging and Maintenance Guide
  • ADLINK NuPRO-865 Single Board Computer Hardware Troubleshooting Guide
  • ADLINK NuPRO-840 P4 Industrial SBC Architecture Maintenance
  • ADLINK NuPRO-770 Full length SBC Configuration and Maintenance
  • ADLINK NuPRO-595 Industrial Half length SBC Motherboard Configuration and Maintenance Guide
  • ADLINK cPCI-6840 Series Single Board Computer Installation, Configuration, and Maintenance Guide
  • Foxboro 43AP Pneumatic Controller Technical Specifications and Selection Guide
  • ADLINK cPCI-3720: 3U CompactPCI Low Power Pentium III CPU Module
  • ADLINK NuPRO-E47: PICMG 1.3 13th Generation Core Industrial SHB
  • ADLINK NuPRO-E43: PICMG 1.3 Core 7th Generation Industrial SHB
  • ADLINK NuPRO-780 PICMG Bus Core CPU Card
  • ADLINK cPCI-6965 6U CompactPCI Core Dual Core Single Board Computer
  • ADLINK USB/LPCI/LPCIe-3488A GPIB Interface Card Selection and Application Guide
  • Rittal SK 3241.700 Blue e+Cabinet Fan Filter Unit
  • ADLINK CPCI-8168 8-Axis Motion Control Card and HSL Network Integration Solution
  • ADLINK PCIe-PXIe-8638 High Speed PXIe Bus Expansion Scheme
  • ADLINK PCIe GIE7x Poe+Frame Grabber Hardware and Power Management Detailed Explanation
  • ADLINK PCIe-7396 Digital I/O Card Deployment Guide
  • ADLINK PCI-8164 Advanced Motion Control Card Deployment Guide
  • ADLINK PCI-8154 Motion Control Card Deployment Guide
  • ADLINK PCI-8134 Motion Control Card Deployment Guide
  • ADLINK NuPRO-E42 Industrial Control Motherboard Deployment Guide
  • ADLINK MXC-6600 Embedded Platform Deployment Guide
  • ADLINK MXC-6000 Industrial Control Computer Deployment and Optimization Guide
  • ADLINK MXC-2300 Embedded System Deployment Guide
  • ADLINK MCM-204 Edge DAQ Deployment Configuration Guide
  • ADLINK MCM-100/102 Deployment Calibration Guide
  • Deployment and Performance Optimization of ADLINK MXC-6400 Industrial Control Computer
  • Selection and Deployment of ADLINK Matrix Series Industrial Control Computers
  • российские промышленные новые машины.Наш отдел дебютировал в 2026 году в России Международная промышленная ярмарка INNOPROM
  • Deeply cultivating the Eurasian industrial market, linking new industrial opportunities between China and Russia
  • Deployment and troubleshooting of ADLINK GIE64+PoE acquisition card
  • Honeywell UMS Security System Troubleshooting Guide
  • Honeywell Expert Series C I/O Troubleshooting Guide
  • ADLINK EOS-1200 Vision System Deployment and Troubleshooting
  • ADLINK DLAP-5200 series AI engine deployment and optimization
  • ADLINK DLAP-4000 Deployment and BIOS Optimization
  • ADLINK Matrix MXC-2000 Deployment and Troubleshooting
  • ADLINK DAQe-2000 series acquisition card calibration and synchronization
  • ADLINK cPCI-6520 Core i7 Processor Blade Engineering Application Guide
  • ADLINK CM1-86DX3 PC/104 Embedded Single Board Computer Engineering Application Guide
  • Honeywell DC1000 Series PID Temperature Controller Engineering Application Guide
  • ALSTOM MiCOM C264 Substation Controller Engineering Application Guide
  • EMERSON AMS 2140 Practical Guide for On site Dynamic Balance and Vibration Analysis
  • ADLINK NuPRO-E320 motherboard deployment and tuning guide
  • ADLINK NuPRO-800 Dual PIII Industrial SBC Maintenance and Upgrade Guide
  • ADLINK NuPRO-598 SBC Maintenance Practical Guide
  • ADLINK MXC-6300 Fanless Embedded Industrial Control Computer Deployment Guide
  • ADLINK Express-BASE7 Carrier Board Quick Deployment and Debugging Guide
  • ADLINK DLAP-211 Edge AI Platform Selection and Deployment Guide
  • ADLINK 7230 Series Isolation DIO Card Selection and Engineering Application Guide
  • ADLINK cPCI-6965 SBC Embedded Installation and BIOS Tuning Guide
  • ADLINK 7200 Series High Speed DIO Card Practical Guide
  • ADLINK DLAP Series Edge AI Acceleration Platform Selection and Deployment Practical Guide
  • DEIF TCM-2 thyristor control module: Wind power cut in control engineering guide
  • DEIF MVR-200 Medium Voltage Relay: Installation and Wiring Engineering Guide
  • DEIF MDR-2 Differential Relay: Engineering Guide for Generator Differential Protection
  • DEIF Delomatic 3 AOM: Engineering Guide for Analog Output Modules
  • DEIF AGI 400 Graphic Interface: Ship and Industrial HMI Solution