Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • ABB Electrical DP40C3P-F Definite Purpose Contactor
    ❤ Add to collection
  • ABB Electrical DP40C3P-F Definite Purpose Contactor

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    Electrical DP40C3P-F Definite Purpose Contactor
    • ¥1059.00
      ¥5883.00
      ¥1059.00
      ¥1059.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:7.280KG
    • Quantity:
    • (Inventory: 2)
Description
Electrical DP40C3P-F Definite Purpose Contactor

ABB Electrical DP40C3P-F Definite Purpose Contactor

Basic Parameters

Rated current: 40A, the current value refers to the main contact can be long-term stability of the current size, determines the power range of the load can be controlled, suitable for some medium-power electrical equipment control.

Number of poles: 3 poles, means that the contactor has three main contacts, can control three-phase circuit at the same time, commonly used in three-phase motors and other three-phase load control, in order to achieve the motor start, stop, forward and reverse and other operations.

Control voltage: 24V AC, indicating that the working voltage required for its control coil is 24V AC, in practical applications, it is necessary to provide a stable 24V AC power supply to drive the action of the contactor to ensure that it can reliably control the on-off of the main circuit.

Rated voltage: 600V, refers to the maximum voltage that the main contacts of the contactor can withstand, this parameter ensures that the contactor can work safely and reliably in circuits of the corresponding voltage level, so that it can be used in a variety of different voltage levels of the electrical system, but it should be noted that the voltage of the circuit connected to the voltage should not exceed this rated voltage.

Performance characteristics

High reliability: the use of high-quality contact materials and advanced manufacturing process, the contacts have good electrical conductivity, wear resistance and anti-melting welding, can maintain stable contact performance under frequent on-off operations, reduce contact resistance, reduce energy consumption and heat, thereby improving the reliability and service life of the entire contactor to ensure the stable operation of the electrical system.

Fast response: The control coil has low inductance and resistance, which can produce electromagnetic force quickly after the control voltage is turned on, so that the moving iron core is quickly absorbed, driving the main contacts to close, and realising the fast connection to the load; when the control voltage is disconnected, it can also be quickly released, so that the main contacts are disconnected and the load circuit is cut off in a timely manner. This fast response capability makes it suitable for occasions with high requirements on control speed, such as frequent start-stop control of motors in automated production lines.

Compact design: its compact structural design, small size, occupies less space, easy to install and wiring in a variety of electrical control cabinets, distribution boxes and other limited space, can effectively save installation space, reduce the overall size and cost of the equipment, but also to facilitate the combination and integration with other electrical components, to improve the integration of the electrical system and aesthetics.

Good compatibility: As a member of ABB electrical product series, DP40C3P-F contactor has good compatibility and working ability with other ABB electrical components, such as overload relay, thermal relay, control relay, etc. It can be easily composed of various control circuits and control devices. It can easily form various control and protection circuits to achieve comprehensive control and protection of electrical equipment, providing users with one-stop electrical solutions and reducing the complexity of system design and installation.

Conformity with standards: The contactor conforms to a number of international standards, such as IEC 60947-4-1, UL 508, etc. These standards cover the performance, safety, electromagnetic compatibility and other requirements of the contactor, ensuring the universality and reliability of the product on a global scale, so that it can be safely and stably operated in the electrical systems of different countries and regions to meet the needs of various industrial and commercial applications.

Areas of application

HVAC system: In the heating, ventilation and air conditioning system, it is used to control the motor start and stop of air conditioning units, chillers, fans and other equipment. For example, in central air-conditioning systems, DP40C3P-F contactors control the operation of compressors, fans and other motors to achieve the regulation of indoor temperature, humidity and air circulation, providing a comfortable indoor environment.

Refrigeration equipment: commonly used to control refrigeration compressor, condensing fan, evaporating fan and other refrigeration equipment motors, to ensure the normal operation of the refrigeration system. In supermarket freezers, cold storage and other refrigeration places, the contactor can reliably control the start and stop of refrigeration equipment, to ensure that food and other items of cold storage and freezing effect.

Industrial automation: In all kinds of industrial production equipment, such as machine tools, injection moulding machines, printing presses, textile machinery, etc., it can be used to control the forward and reverse of the motor, variable speed and other operations, so as to realise the automation control of the production process. Injection moulding machine, for example, through the contactor control injection moulding machine open and close the mould motor, screw motor operation, complete the plastic product injection moulding process.

Pump control: It can be used to control the motors of various pumps, oil pumps and other pumping equipment to achieve the delivery of liquid and circulation control. In the field of water supply and drainage system, industrial fluid conveying system and so on, DP40C3P-F contactor can ensure the reliable operation of pumps and meet the needs of liquid conveying under different working conditions.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice