GE DS200TCTGG2A Turbine Trip Board
GE DS200TCTGG2A Turbine Trip Board
Part Number DS200TCTGG2A Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockDS200TCTGG2A is a TC2000 TMR Simplex Trip Board and is part of the GE Speedtronic Mark V gas turbine control. The DS200TCTGG2A is utilized to regulate a gas turbine that is either heavy-duty or aero-derivative. There are two types of Relays, Primary Trip Relays, and Emergency Trip Relays.
In the event of a communication failure, the Primary Trip Relays are employed, while the Emergency Trip Relays are used in the event of an emergency trip. There are 21 plug-in relays, three 50-pin connectors, and two 12-pin connectors on the DS200TCTGG2A. Because of the 21 relays on the TMR Simplex board, it is very fragile.
ƒ The Series 90-30 Hand-Held Programmer (IC693PRG300) cannot be used to configure this module. New Features The Series 90-30 DeviceNet Master Module allows a Series 90-30 PLC to send and receive I/O data from a DeviceNet network.
Module features include:
ƒ Support for all standard data rates (125K, 250K, 500K)
ƒ Support for 255 bytes input data transfer and 255 bytes output data transfer per slave
ƒ Support for 3972 bytes of input data transfer and 3972 bytes of output data transfer per master
ƒ Support for two I/O connections per Slave - Typically one connection is used for Polled and the other is used for Strobe, Cyclic, or COS
ƒ Support for Poll, Strobe, Cyclic and COS I/O Connections, Fragmented I/O and Explicit Messaging
ƒ Support for Unconnected Message Manager (UCMM) with 1 proxy connection per slave device
ƒ Support for configuration of the global scan rate
ƒ Support for configuration of update rates for Poll and COS/Cyclic on a connection basis
ƒ Support for PLC-application initiated explicit messaging via a COMMREQ
ƒ Master can be configured to operate as a slave simultaneously with master operation
ƒ Configurable fault behavior on loss of communication
ƒ Reports loss or reestablishment of communication with slaves in PLC fault table (configurable)
ƒ Support for 64 network device status bits (note: the bit for the master itself is always zero)
ƒ Firmware update via service port on module
Compatibility
ƒ Compatible with any Series 90-30 CPU except IC693CPU321 and IC693CPU340. Configuration size is limited for CPU311/313/331, as described on the next page.
ƒ Requires release 8.0 CPU firmware. The latest Release 10 is recommended, if available for the particular CPU.
ƒ Requires CIMPLICITY Machine Edition Logic Developer PLC version 3.0 plus the appropriate service pack or special (or a version later than 3.0).
ƒ Not compatible with the VersaPro™, Control, or Logicmaster™ programming software.
Features
▪ Contains 10 Mbytes of battery-backed user memory and 10 Mbytes of non-volatile flash user memory.
▪ Provides access to bulk memory via reference table %W.
▪ Configurable data and program memory.
▪ Programming in Ladder Diagram, C, Structured Text, and Function Block Diagram.
▪ Supports auto-located Symbolic Variables that can use any amount of user memory.
▪ Reference table sizes include 32Kbits for discrete %I and %Q and up to 32K words each for analog %AI and %AQ.
▪ Supports Series 90-70 discrete and analog I/O, communications, and other modules. For a list of modules supported, refer to the PACSystems RX7i Installation Manual, GFK-2223.
▪ Supports all VME modules supported by Series 90-70.
▪ Supports RX7i data monitoring over the web. Allows a combined total of up to 16 web server and FTP connections.
▪ Supports up to 512 program blocks. Maximum size for a block is 128KB.
▪ Test Edit mode allows you to easily test modifications to a running program.
▪ Bit-in-word referencing.
▪ Battery-backed calendar clock.
▪ In-system upgradeable firmware.
▪ Three isolated serial ports: an RS-485 serial port, an RS-232 serial port, and an RS-232 Ethernet station manager serial port.
▪ The embedded Ethernet interface provides:
- Data exchange using Ethernet Global Data (EGD)
- TCP/IP communication services using SRTP
- Support for SRTP Channels, Modbus/TCP Server, and Modbus/TCP Client
- Full programming and configuration services
- Comprehensive station management and diagnostic tools
- Two full-duplex 10BaseT/100BaseT/TX (RJ-45 Connector) ports with an internal network switch providing auto-negotiated network speed, duplex mode, and crossover detection.
- User-configurable Redundant IP address
- Time synchronization to SNTP time server on Ethernet network (when used with Release 5.00 or later CPU module).
email:1583694102@qq.com
wang@kongjiangauto.com