  • Foxboro FBM204  0 to 20 mA I/O Module
    ❤ Add to collection
  • Foxboro FBM204 0 to 20 mA I/O Module

    Foxboro FBM204  0 to 20 mA I/O Module

    • ¥41223.00
      ¥41203.00
      ¥41223.00
      ¥41223.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:12203.000KG
    • Quantity:
    • (Inventory: 55)
Description

Foxboro FBM204  0 to 20 mA I/O Module


Foxboro FBM204  0 to 20 mA I/O Module

DESCRIPTION

The FBM204, 0 to 20 mA Input/Output contains four 20 mA dc analog input channels and four 20 mA dc analog output channels. Each input channel accepts an analog sensor input such as a 4 to 20 mA transmitter, or a self-powered 20 mA source. Each output channel drives an external load and produces a 0 to 20 mA output. The inputs/outputs are galvanically isolated from other channels and ground.

The FBM204 performs the signal conversion required to interface the electrical input/ output signals from the field sensors to the optionally redundant fieldbus. The FBM204 executes the Analog I/O application program, which provides the following configurable options: Conversion Time, Fail-Safe Configuration (Hold/Fallback), and Analog Output Fail-Safe Fallback Data (on a per channel basis). The Fieldbus Module (FBM) may instead execute a distributed PIDA (DPIDA) application program to provide a fast control loop running in it

Features

• Four 20 mA dc analog input channels 

• Four 20 mA dc analog output channels 

• Each input and output channel is galvanically isolated 

• Rugged design suitable for enclosure in Class G3 (harsh) environments 

• Execution of an analog I/O application program that provides conversion time and configurable options for Rate of Change Limits 

• High accuracy achieved by sigma-delta data conversions for each channel 

• Termination Assemblies (TAs) for locally or remotely connecting field wiring to the Compact FBM204 

• TA for use with Output Bypass Station to maintain outputs during maintenance operations 

• 3-tier termination assembly for per channel internally and/or externally loop powered transmitters 

• Support for DPIDA control blocks

High Accuracy

For high accuracy, the module incorporates Sigma-Delta data conversion on a per channel basis, which provides new analog input readings every 25 ms, and a configurable integration period to remove any process and/or noise and power line frequencies. Each time period, the FBM converts each analog input to a digital value, averages these values over the time period and provides the averaged value to the controller

Standard Design

FBM204 has a rugged extruded aluminum exterior for physical protection of the circuits. Enclosures specially designed for mounting the FBMs provide various levels of environmental protection, up to harsh environments, per ISA Standard S71.04

Fieldbus Communication

A Fieldbus Communications Module or a Control Processor interfaces to the redundant 2 Mbps module Fieldbus used by the FBMs. The FBM accepts communication from either path (A or B) of the 2 Mbps Fieldbus. If one path is unsuccessful or is switched at the system level, the module continues communication over the active path.

Functional Specifications

Input Channels (Four)

• Accuracy (Includes Linearity): ±0.03% of span 

• Accuracy Temperature Coefficient: ±50 ppm/ºC 

• Input Signal A/D Conversion: Each channel performs A/D signal conversion using an independent Sigma-Delta converter. 

• Input Channel Impedance: 61.5 Ω nominal 

• Integration Period: Software configurable 

• Common Mode Rejection: >100 db at 50 or 60 Hz 

• Normal Mode Rejection: >95 db at 50 or 60 Hz 

• Field Device Cabling Distance: Maximum distance of the field device from the FBM is a function of compliance voltage (20.2 V dc at 20.4 mA input), wire gauge, and voltage drop at the field device. 

• Loop Power Supply Protection: Each channel is channel-to-channel galvanically isolated, current limited, and voltage regulated. All analog inputs are limited by their design to less than 30 mA. If the current limit circuit shorts out, the current is limited to about 100mA.

Output Channels (Four)

• Accuracy — Analog (Includes Linearity): ±0.03% of span 

• Accuracy Temperature Coefficient: ±50 ppm/ºC 

• Output Load: 750 Ω maximum 

• Output Processing Delay: 30 ms maximum 

• Resolution: 13 bits 

• Field Device Cabling Distance: Maximum distance of the field device from the FBM is a function of compliance voltage (19.6 V dc at 20.4 mA input), wire gauge, and voltage drop at the field device.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ABB ACS880-01-025A-3 frequency converter
  • Emerson DeltaV S-series Traditional I/O Modules
  • HONEYWELL EXCEL 5000 OPEN SYSTEM
  • Pepperl+Fuchs RSD-CI2-Ex8 Analog Input Module
  • Bently Nevada 3500/50M tachometer module
  • Woodward 2301A 9907 series electronic load distribution and speed controller
  • ABB IMDSI13 Digital Slave Input Module
  • Eaton XV-102 Touch Screen Display
  • Rockwell ProSoft MVI56-MCM Modbus master-slave communication module
  • Watlow Series CLS200 Controller
  • GE IS230 Series Industrial Managed Layer 2 Switches
  • GE IC693TCM302/303 Temperature Control Module
  • MKS 979B Atmosphere to Vacuum Transducer
  • What scenarios is the Syco Tec 4061 AC motor spindle suitable for?
  • Emerson DeltaV Electronic Marshalling Migration Solution
  • Barber Colman MA41-7153-502 and similar series actuators
  • BARTEC MODEX PROFIBUS 07-7331-2305 Series Interface Module
  • Rockwell Automation 1794 Series FLEX I/O Digital Input Module
  • GE PCI5565 Multi Channel MIL-STD-1553 Interface Card
  • How to install the Rockwell Automation 1757-SRM (B-series) module?
  • KIDDE S732DVT-EST1 Digital Video, 2-Way MPD Data Tx, MM, Can
  • Foxboro Evo ™ FBM217 Discrete Input Module
  • Allen-Bradley SLC 500 ™ 1746 series I/O modules
  • Allen-Bradley SLC 500 ™ Installation Guide for 32 Channel Digital I/O Module
  • Allen Bradley 1746-NI8 Analog Input Module Application Case
  • Rockwell 1746-IB32 Digital Input Module
  • Emerson PACSystems ™ Ethernet Switch SLM082
  • How to install GE IC695CRU320 redundant control unit?
  • Bently 3500/15 AC and DC power modules
  • Horner APG HE693CALKIT simulation module
  • ABB INNPM22 Network Processor Module
  • Eckardt SRI986 Intelligent Valve Positioner
  • Honeywell System 57 5704 Control System
  • Schneider Electric 140CHS 1100 Communication Module
  • Moog CD series compact dynamic brushless servo motor
  • HARTING DIN 41612 connector
  • ABB DAPU100 3ASC25H204 Interface Template
  • ProSoft Technology ILX56-PBM PROFIBUS DPV1 Master/Slave Module
  • Emerson DeltaV S Series Traditional I/O Modules
  • MOTOROLA MVME6100 series VME single board computer
  • Emerson MVME5100 Series VME Bus Processor Module
  • Siemens 6EP1334-3BA00 (SITOP PSU200M) stabilized power supply
  • GE Power Management SR489 Generator Management Relay
  • Eaton MTLx544-S Series (MTL4544/S, MTL5544/S) Relay Power Supply
  • Emerson MVME5100 Series VME Bus Processor Module
  • Teknic SSt-6000-U Digital Servo Drive
  • HIMA HIMatrix MI 24 01 Safety Related Controller Module (HI 800 209 E)
  • Horner Automation MAN0344-03 Industrial Controller/Human Machine Interface (HMI)
  • Emerson Automation Series MC-PHAI01 (51403479-150) 8-Channel Analog Input Module
  • Bently Nevada 3500/42M Proximity Seismic Monitor
  • GE VMIACC5595 Embedded Industrial Control Module
  • Rockwell SLC ™ 500 series 1747-L543 (SLC 5/04 controller)
  • Honeywell WEB-HMI10/CF 10.1 "TFT ARM Cortex-A53 Quad Core 3 Ethernet, 2 USB ports
  • How to install the Rockwell Automation 1756 series ControlNet communication module?
  • National Instruments 6030E/6031E/6032E/6033E series
  • ABB 1TGE120011R1000 motor and feeder control unit
  • Watlow CLS200 series controller
  • Schneider 140DDI84100 Discrete Input Module
  • How to install the Modicon Quantum 140ACI03000 analog input module?
  • Rockwell Automation ControlLogix 5570 and 5560 controllers
  • ABB IEMMU21 module installation unit (rear installation)
  • Endress+Hauser Prosonic T FMU30 Ultrasonic Liquid Level Measuring Instrument
  • ABB SC510 submodule carrier (without CPU)
  • Beijer Mitsubishi Electric E1000 Series Operation Panel
  • HIMA HIMatrix F30 Compact Safety Controller
  • HIMA HIMax Safety Control System
  • HIMA HIMatrix F2 DO 8 01 Remote I/O Module
  • HIMA HIQuad X Safety System
  • HIMA HIMax X-SB 01 System Bus Module
  • How to order KOLLMORGEN Saia PCD series I/O modules?
  • Kollmorgen S700 series digital servo amplifier
  • KOLLMORGEN P70360 High Performance Microstep Driver
  • KOLLMORGEN AKM series synchronous servo motor
  • KOLLMORGEN AKD ®- N servo drive
  • KOLLMORGEN AKD ® Servo driver CANopen communication
  • KOLLMORGEN AKD ® Servo drive fault card
  • SERVOSTAR ® CD series servo amplifier
  • SERVOSTAR ® Usage of CD-LITE servo amplifier
  • SERVOSTAR ™ 601... 620 digital servo amplifier (S600 series)
  • B&R Power Panel 300/400 Touch Screen
  • Emerson S-series Mass Connection Solutions
  • Emerson DeltaV SIS Logic Solver (SLS1508)
  • How to order Emerson DeltaV Ethernet I/O Card (EIOC)?
  • Emerson DeltaV ™ M-series Traditional I/O
  • Emerson DeltaV ™ Electronic Marshalling for Migrations
  • Emerson DeltaV Controller Redundancy Function
  • Emerson DeltaV Bulk Power Supplies
  • Emerson DeltaV SD Plus Controller
  • Emerson DeltaV M Series Virtual I/O Module 2 (VIM2)
  • Emerson DeltaV M Series MD Plus Controller
  • Emerson Ovation ™ Power system (5X00785G09)
  • Emerson DeltaV Intelligent Switch
  • Emerson A6110 Dual Channel Shaft Vibration Monitor
  • Emerson MMS 3210/xxx-xxx Dual Channel Shaft Position Transmitter for Eddy Current Sensors
  • Emerson MMS 3120 Dual Channel Bearing Vibration Transmitter
  • Emerson MMS 677X Dual Channel Bar Chart Indicator
  • Emerson Martens Standard Signal Instrument S 1010
  • Emerson CON021 Eddy Current Signal Converter Ordering Method!
  • How to order AMS 6500 Classic system protection card?
  • Emerson Machine Monitoring Systems RPM Transformer PR 9376
  • Emerson Linear Displacement Sensor PR 9350/.. Series
  • Emerson PR 9376 series eddy current sensor system
  • Emerson Electric Power Absolute Vibration Sensor (PR 9266/.. And PR 9268/..)
  • How to operate Emerson Motion Control FX 490?
  • Emerson The Ovation ™ What fields is the Control System applicable to?
  • Emerson Ovation Distributed Control System Input/Output (I/O) Module
  • Emerson HART High Performance Analog Input Module
  • Emerson Ovation ™ Controller Model OCR1100
  • Emerson PAC8000 Remote I/O
  • Emerson A6500-LC LVDT preamplifier
  • EMERSON A6370 Overspeed Protection Monitor
  • EMERSON A6110 axis relative vibration monitor
  • EMERSON FloBoss ™ S600+ Flow Computer
  • EMERSON CSI 2130 Machinery Health ™ Analyzer
  • AMS 2140 Machinery Health ™ How to operate Analyzer?
  • Emerson AMS Suite: Machinery Health ™ Manager v5.61 Software Installation Guide
  • GE Fanuc Series 90-30 Programmable Controller
  • GE PACSystems RX7i Controller
  • How to install GE Series 90-70 Genius Bus Controller?
  • GE VersaMax ® Programmable controller
  • GE VMIVME-7696 Pentium II processor based on VMEbus single board computer
  • GE VMIVME-7695 Single Slot Pentium II Embedded Module Processor
  • GE VMIVME-7459 Single Slot VME IDE CD-RW/Hard Disk Module
  • GE VMIVME-6016 VMEbus Intelligent 16 Channel Asynchronous Serial Controller
  • GE VMIVME-5620 Intelligent HSD Simulator
  • GE VMIVME-5588 high-speed reflective memory board
  • GE VMIVME-5532L VMEbus fiber optic repeater link
  • How to order GE VMIVME-5531L VMEbus fiber optic repeater link?