Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE Field Control™ Genius® Bus Interface Unit
    ❤ Add to collection
  • GE Field Control™ Genius® Bus Interface Unit

    GE Field Control™ Genius® Bus Interface Unit

    • ¥23650.00
      ¥24520.00
      ¥23650.00
      ¥23650.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.600KG
    • Quantity:
    • (Inventory: 31)
Description

GE Field Control™ Genius® Bus Interface Unit


GE Field Control™ Genius® Bus Interface Unit

DESCRIPTION

Field Control is a family of highly modular distributed I/O and control products. They are suitable for use in a wide range of host architectures. The heart of the Field Control system is the Bus Interface Unit. The Bus Interface Unit provides intelligent processing, I/O scanning, and feature configuration for a group of up to eight I/O modules. Together, the Bus Interface Unit and its modules make up a Field Control station (see the illustration, left).The Bus Interface Unit and I/O modules are enclosed in sturdy, compact aluminum housings. Bus Interface Unit and I/O modules bolt securely to separate Terminal Blocks, which provide all field wiring terminals. The I/O Terminal blocks are generic and allow different I/O module types to be mounted on the same base. I/O Terminal Blocks are available with box-type terminals, barrier-type terminals, or wire-to-board connectors. All Terminal Blocks must be mounted on a DIN rail. The DIN rail, which serves as an integral part of the grounding system, can also be mounted on a panel.

Field Control Features

Features and benefits of Field Control include:

· wiring savings 

·  better up time 

·  easy installation and maintenance 

·  spare parts savings 

·  low cost 

·  feature flexibility 

·  open architecture / adaptable to a variety of networks 

·  distributed I/O n small, compact I/O modules with generic terminal wiring bases. 

·  DIN rail mounted

There are three basic types of Field Control modules:

·  Bus Interface Unit. The illustration below shows a Genius Bus Interface Unit. 

·  I/O modules ß Micro Field Processor 

·  Terminal Blocks: 

·  Bus Interface Unit Terminal Block. 

·  I/O Terminal Blocks, each of which accommodates two I/O modules. 

·  Auxiliary Terminal Blocks. These optional terminal strips can be connected to the side of an I/O Terminal Block if extra common terminals are needed.

Genius Bus Interface Unit

The Genius Bus Interface Unit (IC670GBI002 or IC697GBI102) interfaces Field Control I/O modules to a host PLC or computer via a Genius bus. It can exchange up to 128 bytes of input data and 128 bytes of output data with the host, each Genius bus scan. It can also handle Genius datagram communications. The intelligent processing capabilities of the Genius Bus Interface Unit allow the configuration of features such as fault reporting, selectable input and output defaults, analog scaling and analog range selection for the modules in the station. In addition, the Genius Bus Interface Unit performs diagnostic checks on itself and its I/O modules, and relays diagnostic information to the host (if configured for fault reporting) and to a Hand-held Monitor.

The Genius Bus Interface Unit can be used on a bus controlled by redundant CPUs or Bus Controllers. It can also be used on a dual bus. The Bus Interface Unit mounts on a Bus Interface Unit Terminal Block. It can be removed and replaced if necessary without removing the wiring or reconfiguring the I/O station.

Bus Interface Unit Terminal Block

The Bus Interface Unit Terminal Block, which included with the BIU, has connections for power wiring and single or dual communications cables. It has built-in bus switching circuitry, allowing the Bus Interface Unit to be used on a dual (redundant) Genius bus (no external Bus Switching Module is needed). The Bus Interface Unit Terminal Block stores the configuration parameters selected for the station.

Micro Field Processor

The Series 90 Micro Field Processor (MFP) is a Micro PLC that provides local logic within a Field Control station. The Micro Field Processor is the same size as a Field Control I/O module and occupies one of the eight available I/O slots in a Field Control station. MFP features include:

· Compatible with Logicmaster 90-30/20/Micro programming software, revision 6.01 or later. 

· Alarm processor 

· Password protection 

· Built-in communications port that supports Series 90 protocols (SNP and SNPX)

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice