Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE MAVS01L1AB0751D-140393N Soft Starter
    ❤ Add to collection
  • GE MAVS01L1AB0751D-140393N Soft Starter

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥54347.00
      ¥55653.00
      ¥54347.00
      ¥54347.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.540KG
    • Quantity:
    • (Inventory: 5364)
Description
<span style="font-size: 20px; font-family: arial;">GE MAVS01L1AB0751D-140393N Soft Starter</span>

GE MAVS01L1AB0751D-140393N Solid-State Soft Starter

The GE MAVS01L1AB0751D-140393N is a medium-voltage, solid-state soft starter from General Electric's MV Series, specifically designed for the controlled acceleration and deceleration of high-power three-phase AC induction motors. This device is engineered to manage the high inrush current associated with starting large motors by gradually ramping up the voltage applied to the motor terminals, thereby reducing mechanical stress on the motor, connected equipment such as pumps, fans, and compressors, and the electrical distribution system. The MAVS01L1AB0751D-140393N replaces traditional electromechanical reduced-voltage starters like auto-transformers or wye-delta starters, offering superior control, reliability, and reduced maintenance. It is typically installed between the medium-voltage circuit breaker and the motor.

Technical Specifications

The GE MAVS01L1AB0751D-140393N is rated for a system voltage of 7.2 kV based on the L1 code designation. The motor full load current rating is 751 Amps based on the 0751 code, representing the key sizing parameter for the soft starter. The starting method employs solid-state voltage ramp control using thyristors (SCRs) to regulate the voltage applied to the motor. Control power typically requires a low-voltage AC or DC supply such as 120V AC or 125V DC for the control circuits. The starter features an integrated bypass contactor that closes once the motor reaches full speed, shunting current around the SCRs to eliminate heat losses and increase efficiency and reliability.

Control and Protection Features

The MAVS01L1AB0751D-140393N offers adjustable start voltage, ramp time, current limit, and soft stop or deceleration control. Advanced units may include pump control to reduce water hammer effects and torque control for specialized applications. Integrated motor protection features include overload protection, overcurrent protection, phase unbalance and phase loss detection, undercurrent protection, excessive starts protection, thyristor over-temperature protection, and ground fault detection. These comprehensive protection functions ensure safe motor operation under all conditions while maximizing equipment life.

Communication and Integration

The soft starter includes serial communication capabilities supporting Modbus RTU protocol, along with hardwired I/O for integration into DCS and PLC systems. Optional Ethernet or other fieldbus cards may be available for enhanced connectivity. The starter is housed in a freestanding metallic cabinet with enclosure rating depending on the B code, typically NEMA 1 for indoor applications or NEMA 3R for outdoor installations. Forced air cooling ensures reliable operation under full load conditions, while the robust construction is designed for demanding industrial environments.


Applications

The GE MAVS01L1AB0751D-140393N is deployed in heavy industrial applications requiring controlled starting of large medium-voltage motors. Typical applications include pumps in water and wastewater treatment facilities, fans in HVAC and ventilation systems, compressors in industrial gas and air systems, conveyors in mining and material handling, and mills and crushers in mineral processing. The soft starter is also used in marine propulsion systems, oil and gas pumping stations, and any application where motor inrush current management and mechanical stress reduction are critical for equipment longevity and power system stability.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Mitsubishi Electric GT23 Series HMI Maintenance Guide
  • Mitsubishi GT27 HMI Application Guide
  • Siemens SIMATIC ET 200M Selection
  • Lenze 8200 Vector Selection
  • Troubleshooting of Siemens MASTER DRIVES VC
  • FANUC I/O Unit A Maintenance Manual
  • Allen Bradley PLC-5 Classic Controller Complete Guide
  • Maintenance of M&C SP2006-H/DIL Sampling Probe
  • Pro face connection to Mitsubishi DIASYS Netmation
  • OMRON SYSMAC C-series/CVM1/CV series analog I/O units
  • LTI ServoOne Replacement and Troubleshooting
  • OMRON C-series AD/DA module configuration
  • Siemens 840C 611D Module Replacement Guide
  • Diagnosis and maintenance of ABB ACS550 frequency converter fault codes
  • OMRON NX1P2 Hardware Debugging Guide
  • Fuji FRENIC Mini inverter troubleshooting
  • Braided Forissier Braided Copper Strip Selection Guide
  • Mecc Alte MC200 Controller Engineering Debugging and Troubleshooting
  • Schneider Square D 9036/9037/9038 Electromechanical Liquid Level Controller
  • Pilz PSS 4000 distributed safety control
  • Schneider TeSys GV5/GV6 Motor Circuit Breaker Operation and Protection Guide
  • Eaton Freedom NEMA Contactor Starter Complete Guide
  • OMRON D4SL-N/D4SL-NSK10-LK Safety Door Switch Comprehensive Guide
  • NI CompactRIO Embedded System
  • Emerson Ovation I/O Module Troubleshooting and Replacement Practical Guide
  • MITSUBISHI A-series PLC Troubleshooting Replacement
  • Automation Direct DL06 D0-06DD1 Replacement Guide
  • IFM CR2530 Intelligent Controller Guide
  • OMRON FH/FHV series visual sensor controller
  • Pilz PDP67 F4 code troubleshooting
  • Panasonic FP-X PLC Replacement and Troubleshooting
  • OMRON CK3W-AX Multi axis Control Selection
  • Debugging and maintenance of EPSON RC90/RC90-B controller
  • Nthytronic Group iRTUe I/O Expansion Module
  • Schneider ATV320 Inverter Installation and Debugging Guide
  • Eaton SPB Drawdown Switch Maintenance Guide
  • GFS EVO-SP dual fuel retrofit complete solution
  • OMRON CJ2 CPU Troubleshooting and Maintenance
  • Complete Guide to Lenze ECS Servo System
  • GE EX2100e Excitation System Complete Guide
  • OMRON G3PW Power Controller: Parameter Setting and Troubleshooting Guide
  • Key Points for Selection and Deployment of MITSUBISHI FX3GE PLC
  • Beckhoff EP23xx EtherCAT Box Selection Troubleshooting
  • MITSUBISHI MDS-B servo troubleshooting
  • TOYO valve pressure and temperature selection
  • SIEMENS SIMODRIVE 611 HR/HRS Replacement and Advanced Positioning Techniques
  • SIEMENS SINUMERIK 840C 611-D Startup and Troubleshooting Guide
  • FANUC Series 0i-F Maintenance and Troubleshooting
  • Troubleshooting Schneider Modicon TM3 Bus Expansion
  • Troubleshooting of R&S EPL1000
  • Baum ü llerb b maXX 5000 Safety Configuration and Troubleshooting Guide
  • Huichuan AM600 Motion Controller Malfunction and Replacement Guide
  • Allen Bradley Ultra3000 Servo Motor Replacement Guide
  • NEC NL8060BC26-17 LCD Module Maintenance and Replacement
  • ABB Pluto Safety PLC Maintenance and Troubleshooting
  • OMRON NE1A Safety Controller Troubleshooting and Replacement
  • Allen Bradley 2711P series PanelView Plus human-machine interface terminal
  • NI cFP-22xx on-site integration and troubleshooting
  • KEYENCE XG-8000 Line Scan Visual Debugging Guide
  • OMRON G9SX Security Unit Configuration and Troubleshooting
  • OMRON CPM1A Maintenance and Troubleshooting
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator