GE TP2020SS RMS-9 Gas-insulated metal-enclosed switchgear
GE TP2020SS RMS-9 Gas-insulated metal-enclosed switchgear
Product Overview
GE TP2020SS RMS-9, as a GIS equipment, features compact design, high reliability, environmental protection and energy saving, easy maintenance, high safety and good expandability. It adopts modular design, which is easy to install, expand and maintain. Meanwhile, the internal SF6 gas is filled as insulation medium, which makes the equipment have good insulation and arc extinguishing performance during operation.
Technical specifications
Rated voltage: usually 72.5kV or 145kV, depending on the equipment configuration and application requirements.
Rated current: The rated current varies according to the equipment model and application scenario, and the rated current range of GIS equipment usually ranges from several hundred amperes to several thousand amperes.
Switch type: Including different types of switchgear such as circuit breakers, disconnecting switches, earthing switches and so on.
Structure: metal-enclosed structure with SF6 gas as the insulating medium inside.
Modular design: easy to install, expand and maintain.
Product features
High reliability: GIS equipment adopts strict quality control measures during the design and manufacturing process to ensure the high reliability of the equipment.
Safety: The interior is filled with SF6 gas, which improves the insulation and arc extinguishing performance of the equipment, thus improving the safety of the equipment.
Compact design: small footprint, suitable for installation in space-constrained locations.
Environmental protection and energy saving: SF6 gas has good insulating performance and chemical stability, which has less impact on the environment, while the equipment has low operating loss, which helps energy saving and emission reduction.
Easy maintenance: the modular design makes the maintenance of the equipment more convenient, and the damaged modules can be replaced quickly, reducing the maintenance time and cost.
Good expandability: it can be expanded as needed to adapt to the needs of power systems of different sizes and capacities.
Intelligent management: it can communicate with other intelligent devices to achieve intelligent management and monitoring of the power system.
Application Fields
GE TP2020SS RMS-9 is widely used in a variety of power systems that require high-voltage power distribution and transmission, such as power plants, substations, transmission lines and so on. Its high performance and reliability make it an ideal choice in these fields.
Instructions and warnings related to the operation of the product:
The following specifications must be strictly observed:
The technical specifications and typical applications of the product system must be strictly observed.
PERSONNEL TRAINING: Only trained personnel may install, operate, maintain or repair the product system. These personnel must be instructed on the
These personnel must be instructed and briefed on the conditions in the hazardous area.
Unauthorised modifications: No modifications or structural changes may be made to the product system.
Maintenance Responsibility: It must be ensured that the product system is used only under appropriate conditions and in a condition fully suitable for use.
Working environment: The user must fulfil the specified environmental conditions:
Safety regulations
The following safety regulations must be fully observed when (maintenance) work is carried out on the product system:
1 Disconnect completely.
2 Secure to prevent reconnection.
3 Confirm that the installation has been completed.
4 Perform grounding and short-circuiting.
Maintenance and troubleshooting
Periodic checks:
Periodically check the status of the LEDs on the board to ensure that all signals are operating correctly.
Check that jumpers are configured correctly to ensure proper operation of the board.
Cleaning & Maintenance:
Keep the surface of the circuit board clean and dry to avoid dust and moisture damage to the board.
Regularly check the connection of power and signal cables to ensure that the connection is firm and reliable.
Troubleshooting:
If a fault occurs, you can troubleshoot the problem by checking the LED indicators, jumper configurations, power and signal cables.