Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE VMIVME-9064/32 Reflective Memory Intelligent I/O Controller
    ❤ Add to collection
  • GE VMIVME-9064/32 Reflective Memory Intelligent I/O Controller

    GE VMIVME-9064/32 Reflective Memory Intelligent I/O Controller

    • ¥26500.00
      ¥27520.00
      ¥26500.00
      ¥26500.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.700KG
    • Quantity:
    • (Inventory: 31)
Description

GE VMIVME-9064/32 Reflective Memory Intelligent I/O Controller


GE VMIVME-9064/32 Reflective Memory Intelligent I/O Controller

Functional Characteristics

Introduction: The VMIVME-9064/32 provides a flexible, compact  solution including user-friendly software utilities for the user  who requires I/O products coupled with a preprogrammed SBC  for effective turnkey operation. It is designed to operate with  Abaco Embedded Systems Reflective Memory (RM) products.  VMIVME-9064/32 may reside on multiple nodes of a single  RM link.

Features:

• 68040 single board computer (SBC) with 16 MB of shared  DRAM, 32-bit wide, accessible from the VMEbus 

- System controller functions with full four-level arbiter 

- Front panel run-and-halt and fall status LEDs 

- Front panel reset and abort switches 

• Firmware provides all required support for scanning inputs,  updating outputs, EU and data-type conversions, fault  detection, fault isolation, and error reporting 

• Requires Abaco Reflective Memory  (VMIVME-5550, -5565, -5576, or -5588)

• Optional host software support utilities 

- I/O point manager 

- Report generator 

- Configuration downloader 

- Real time interface software 

- Source code available in C 

• Supports a wide variety of Abaco Built-in-Test I/O modules  (BITMODULES™) 

• Optional CRT-based control panel 

• Low cost expansion

VMIVME-9064/32 — IIOC Firmware1:

• Diagnostic firmware 

- Processor 

- Local memory 

- Global memory 

- Local diagnostic control 

- Error reporting 

- Offline and real time fault detection and isolation 

• Diagnostic control 

- Power up initialization 

- Host initiated (from customer-furnished host computer) 

- Local terminal control 

• Failure reporting 

- Front panel fail LEDs 

- Local terminal option 

- Host report (to VMEbus host) 

• Real time firmware 

- Floating-point to fixed-point conversion 

- Fixed-point to floating-point conversion - Bit-to-byte conversion 

- Byte-to-bit conversion 

- I/O data transfers 

- Real time fault detection 

- Synchro smoothing 

- Analog output smoothing 

- Analog input filtering

VMIVME-9064/32 — Required:

1. 68040 SBC 

2. 20-slot VMEbus chassis assembly 

3.Reflective Memory host interface, one of options 2 through 5  from the option list below

Software Communications Protocol:

The VMIVME-9064/32  IIOC communications protocol utilizes a simple, memory-mapped  control window and interrupt scheme to simplify control by the  RM host computer. The host initializes a memory-mapped RM  allocation page and interrupts each VMIVME-9064/32 IIOC on the  RM link. Each IIOC uses its node number, read from the local RM  board, as an index into the RM allocation page to locate its control  window and buffer space. The host may then write commands for  the IIOC to the appropriate control window and issue a command  interrupt. The IIOC fields the locally generated interrupt, interprets  the command, and executes the requested action. After I/O  configuration, the IIOC posts the locations and word counts of the  configured I/O buffers in the control window. The host and IIOC  then read and write I/O data to these shared RM buffers.

Command List Processing:

The VMIVME-906x IIOCs provide for  command list processing to reduce or eliminate host command  interaction during real time processing. These command lists are  configured after the host has configured all I/O scan lists. Up to  three command lists are supported by the embedded host IIOCs.  These lists contain the scan commands, with associated data  transfer addresses that would be utilized during a real time frame.  Each command list may contain only one scan command for  each of the twelve supported scan list types (that is, primary DO,  secondary DO, primary AI, etc.). Each of the configured command  lists may be executed with a single command each I/O frame,  or may be configured with an execution interval which allows  the host to command autoscanning of each list at the execution  interval provided with the command list configuration data.  Command lists may not contain digital input scan commands  when VMIVME-1110 digital input boards with the 5 ms filter option  are present in the IIOC.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • ABB ACH550 Inverter Maintenance
  • IDEC MicroSmart FC6A Replacement Guide
  • Gefran GILOGIK II Distributed I/O System
  • GE VersaMax Nano/Micro Replacement Guide
  • Nastyaer GIV50-11 limit switch
  • Rockwell Trusted TMR Processor
  • TIANMA NL8060BC21-11KG Industrial LCD
  • CapXon UJ series aluminum electrolytic capacitors
  • FLVOTEK MV10H DC/DC power supply
  • SIEMENS QBE3000/3100 differential pressure
  • Huichuan H3U series PLC high-performance motion control selection and troubleshooting guide
  • Phoenix Contact ILC 1X1 Field Troubleshooting and Engineering Application Guide
  • Allen Bradley Lifeline 4 Cable Switch Field Installation and Troubleshooting Complete Guide
  • Gardner DELCOS 3100 Controller Field Troubleshooting and Maintenance Guide
  • Mitsubishi GOT2000 Utility Troubleshooting and System Maintenance Complete Guide
  • Ohmite EBW Current Sensing
  • Mitsubishi A1S61PN Power Module: Complete Guide to On site Troubleshooting and System Maintenance
  • Complete Guide to On site Maintenance and Troubleshooting of Honeywell TN3801 Electro Motive Liquid Level
  • ABB PSTX/PSR Soft Starter Field Troubleshooting and Maintenance Guide
  • GE Hydran 201Ti Troubleshooting Practice
  • ABB NextMove ESB-2 Debugging and Replacement
  • CAREL PGD Handheld Operator Configuration Replacement
  • Clinical Guidelines for Hiossen EK Implant System
  • Eaton 9PX UPS maintenance and replacement
  • Airlec RYP Precision Pressure Reducing Valve Selection and Maintenance
  • Schneider Modicon M258 Selection and Upgrade
  • KEYENCE XG-8000/7000 adds new features
  • Alfa Laval EPC 50 Upgrades EPC 70 Separators
  • Nidec Unidrive M700 Troubleshooting
  • Mitsubishi A171SCPU Maintenance and Troubleshooting
  • YASKAWA DX200 Feature Pack Complete Guide
  • CKD AxTools servo debugging software (EboDEX)
  • IUSA Copper Tube System Installation and Troubleshooting Guide
  • TAIYO LX Series Generator Common Troubleshooting and Maintenance Guide
  • Automation Direct DL06 PLC Common Troubleshooting and Maintenance Guide
  • Kepco BOP Bipolar Power Supply Troubleshooting and Maintenance Guide
  • Pilz PNOZmulti Safety Controller Troubleshooting and Maintenance Guide
  • HMS Airbus X-gateway troubleshooting
  • Nidec Unidrive SP troubleshooting
  • GE SPEEDTRONIC Mark VI troubleshooting
  • LK-TECH MGv2 Servo Motor System Complete Guide
  • Zebra EPL2 Complete Guide
  • Gold Whistle Servo Drive Complete Guide
  • MITSUBISHI ELECTRIC FR-D700 Inverter Complete Guide
  • Edwards EST-3 Life Safety System
  • ABB ACS380 Inverter Complete Guide
  • MITSUBISHI ELECTRIC MELSEC iQ-R/Q/L Complete Guide
  • Rockwell Automation CompactLogix 5380/5480 Complete Guide
  • CODESYS Control Win SL Soft PLC
  • ABB AC 800M Complete Guide
  • Honeywell 7800 Troubleshooting Guide
  • Troubleshooting of Rockwell AutoMax DPS
  • SNO 4062K/SNO 4062KM Safety Relay On site Troubleshooting and Selection Replacement Guide
  • World Encoders iPHD Series Handheld Operation Box Field Troubleshooting and Replacement Selection Guide
  • Troubleshooting of Copes Vulcan bypass valve
  • Complete Guide for On site Maintenance and Troubleshooting of ZF ClearCommand 9000 Series Ship Propulsion Control System
  • Troubleshooting of Pro face GP Series
  • TI C2000 CLA Software Development Guide
  • Honeywell ControlEdge HC900 Controller Troubleshooting Manual
  • Metso DNA system troubleshooting
  • ABB Millmate Rolling Force Measurement and Control System On site Troubleshooting and Maintenance Guide
  • On site Troubleshooting and Parameter Recovery Guide for Reliance Electric GV3000/SE Vector Inverter
  • EUCHNER Handheld Operating Unit and Electronic Handwheel Field Troubleshooting Guide
  • Microchip dsPIC30F High Performance 16 Bit Digital Signal Controller Field Application and Troubleshooting Guide
  • GE Fanuc VersaMax I/O and Control System Field Maintenance and Troubleshooting Guide
  • Milacron Elektron 400/500/600 Full Electric Injection Molding Machine On site Maintenance and Troubleshooting Complete Guide
  • PRECILEC RE.0444N Guide for On site Maintenance and Replacement of DC Speed Generator
  • Complete Guide to Field Application and Troubleshooting of Mitsubishi GT15-RS2/4 Serial Communication Unit
  • Keyence GS interlock switch
  • GE AT868 AquaTrans Ultrasonic Flow Meter Field Maintenance and Troubleshooting Guide
  • MITSUBISHI ELECTRIC GOT1000 Modbus Connection
  • Allen Bradley Guardmaster Security Practice
  • Delta AH500 PLC system operation and maintenance
  • Pilz PNOZmulti system extension
  • Pilz PNOZ XV3P safety relay
  • Pilz PZE 9 safety relay
  • SCHNEIDER TSX Premium System Operation and Maintenance
  • KONGSBERG HiPAP System Operation and Maintenance Guide
  • KONGSBERG Seatex MRU 5 practical combat
  • KONGSBERG BWMS system operation and maintenance
  • WCU Ship Control Unit Manual
  • Albatross NMEA2000 Integration
  • KONGSBERG PI50 Fishing Troubleshooting Guide
  • Kongsberg C-series cutting machine troubleshooting guide
  • KONGSBERG RCU500 Controller Manual
  • AutroSafe Fire Operation Manual
  • EAU-321 Multi Protocol Serial Port Card
  • MTL4850 Gateway Integration Manual
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice