Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE VMIVME-9064/32 Reflective Memory Intelligent I/O Controller
    ❤ Add to collection
  • GE VMIVME-9064/32 Reflective Memory Intelligent I/O Controller

    GE VMIVME-9064/32 Reflective Memory Intelligent I/O Controller

    • ¥26500.00
      ¥27520.00
      ¥26500.00
      ¥26500.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.700KG
    • Quantity:
    • (Inventory: 31)
Description

GE VMIVME-9064/32 Reflective Memory Intelligent I/O Controller


GE VMIVME-9064/32 Reflective Memory Intelligent I/O Controller

Functional Characteristics

Introduction: The VMIVME-9064/32 provides a flexible, compact  solution including user-friendly software utilities for the user  who requires I/O products coupled with a preprogrammed SBC  for effective turnkey operation. It is designed to operate with  Abaco Embedded Systems Reflective Memory (RM) products.  VMIVME-9064/32 may reside on multiple nodes of a single  RM link.

Features:

• 68040 single board computer (SBC) with 16 MB of shared  DRAM, 32-bit wide, accessible from the VMEbus 

- System controller functions with full four-level arbiter 

- Front panel run-and-halt and fall status LEDs 

- Front panel reset and abort switches 

• Firmware provides all required support for scanning inputs,  updating outputs, EU and data-type conversions, fault  detection, fault isolation, and error reporting 

• Requires Abaco Reflective Memory  (VMIVME-5550, -5565, -5576, or -5588)

• Optional host software support utilities 

- I/O point manager 

- Report generator 

- Configuration downloader 

- Real time interface software 

- Source code available in C 

• Supports a wide variety of Abaco Built-in-Test I/O modules  (BITMODULES™) 

• Optional CRT-based control panel 

• Low cost expansion

VMIVME-9064/32 — IIOC Firmware1:

• Diagnostic firmware 

- Processor 

- Local memory 

- Global memory 

- Local diagnostic control 

- Error reporting 

- Offline and real time fault detection and isolation 

• Diagnostic control 

- Power up initialization 

- Host initiated (from customer-furnished host computer) 

- Local terminal control 

• Failure reporting 

- Front panel fail LEDs 

- Local terminal option 

- Host report (to VMEbus host) 

• Real time firmware 

- Floating-point to fixed-point conversion 

- Fixed-point to floating-point conversion - Bit-to-byte conversion 

- Byte-to-bit conversion 

- I/O data transfers 

- Real time fault detection 

- Synchro smoothing 

- Analog output smoothing 

- Analog input filtering

VMIVME-9064/32 — Required:

1. 68040 SBC 

2. 20-slot VMEbus chassis assembly 

3.Reflective Memory host interface, one of options 2 through 5  from the option list below

Software Communications Protocol:

The VMIVME-9064/32  IIOC communications protocol utilizes a simple, memory-mapped  control window and interrupt scheme to simplify control by the  RM host computer. The host initializes a memory-mapped RM  allocation page and interrupts each VMIVME-9064/32 IIOC on the  RM link. Each IIOC uses its node number, read from the local RM  board, as an index into the RM allocation page to locate its control  window and buffer space. The host may then write commands for  the IIOC to the appropriate control window and issue a command  interrupt. The IIOC fields the locally generated interrupt, interprets  the command, and executes the requested action. After I/O  configuration, the IIOC posts the locations and word counts of the  configured I/O buffers in the control window. The host and IIOC  then read and write I/O data to these shared RM buffers.

Command List Processing:

The VMIVME-906x IIOCs provide for  command list processing to reduce or eliminate host command  interaction during real time processing. These command lists are  configured after the host has configured all I/O scan lists. Up to  three command lists are supported by the embedded host IIOCs.  These lists contain the scan commands, with associated data  transfer addresses that would be utilized during a real time frame.  Each command list may contain only one scan command for  each of the twelve supported scan list types (that is, primary DO,  secondary DO, primary AI, etc.). Each of the configured command  lists may be executed with a single command each I/O frame,  or may be configured with an execution interval which allows  the host to command autoscanning of each list at the execution  interval provided with the command list configuration data.  Command lists may not contain digital input scan commands  when VMIVME-1110 digital input boards with the 5 ms filter option  are present in the IIOC.


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Eckardt SRI986 Intelligent Valve Positioner
  • Honeywell System 57 5704 Control System
  • Schneider Electric 140CHS 1100 Communication Module
  • Moog CD series compact dynamic brushless servo motor
  • HARTING DIN 41612 connector
  • ABB DAPU100 3ASC25H204 Interface Template
  • ProSoft Technology ILX56-PBM PROFIBUS DPV1 Master/Slave Module
  • Emerson DeltaV S Series Traditional I/O Modules
  • MOTOROLA MVME6100 series VME single board computer
  • Emerson MVME5100 Series VME Bus Processor Module
  • Siemens 6EP1334-3BA00 (SITOP PSU200M) stabilized power supply
  • GE Power Management SR489 Generator Management Relay
  • Eaton MTLx544-S Series (MTL4544/S, MTL5544/S) Relay Power Supply
  • Emerson MVME5100 Series VME Bus Processor Module
  • Teknic SSt-6000-U Digital Servo Drive
  • HIMA HIMatrix MI 24 01 Safety Related Controller Module (HI 800 209 E)
  • Horner Automation MAN0344-03 Industrial Controller/Human Machine Interface (HMI)
  • Emerson Automation Series MC-PHAI01 (51403479-150) 8-Channel Analog Input Module
  • Bently Nevada 3500/42M Proximity Seismic Monitor
  • GE VMIACC5595 Embedded Industrial Control Module
  • Rockwell SLC ™ 500 series 1747-L543 (SLC 5/04 controller)
  • Honeywell WEB-HMI10/CF 10.1 "TFT ARM Cortex-A53 Quad Core 3 Ethernet, 2 USB ports
  • How to install the Rockwell Automation 1756 series ControlNet communication module?
  • National Instruments 6030E/6031E/6032E/6033E series
  • ABB 1TGE120011R1000 motor and feeder control unit
  • Watlow CLS200 series controller
  • Schneider 140DDI84100 Discrete Input Module
  • How to install the Modicon Quantum 140ACI03000 analog input module?
  • Rockwell Automation ControlLogix 5570 and 5560 controllers
  • ABB IEMMU21 module installation unit (rear installation)
  • Endress+Hauser Prosonic T FMU30 Ultrasonic Liquid Level Measuring Instrument
  • ABB SC510 submodule carrier (without CPU)
  • Beijer Mitsubishi Electric E1000 Series Operation Panel
  • HIMA HIMatrix F30 Compact Safety Controller
  • HIMA HIMax Safety Control System
  • HIMA HIMatrix F2 DO 8 01 Remote I/O Module
  • HIMA HIQuad X Safety System
  • HIMA HIMax X-SB 01 System Bus Module
  • How to order KOLLMORGEN Saia PCD series I/O modules?
  • Kollmorgen S700 series digital servo amplifier
  • KOLLMORGEN P70360 High Performance Microstep Driver
  • KOLLMORGEN AKM series synchronous servo motor
  • KOLLMORGEN AKD ®- N servo drive
  • KOLLMORGEN AKD ® Servo driver CANopen communication
  • KOLLMORGEN AKD ® Servo drive fault card
  • SERVOSTAR ® CD series servo amplifier
  • SERVOSTAR ® Usage of CD-LITE servo amplifier
  • SERVOSTAR ™ 601... 620 digital servo amplifier (S600 series)
  • B&R Power Panel 300/400 Touch Screen
  • Emerson S-series Mass Connection Solutions
  • Emerson DeltaV SIS Logic Solver (SLS1508)
  • How to order Emerson DeltaV Ethernet I/O Card (EIOC)?
  • Emerson DeltaV ™ M-series Traditional I/O
  • Emerson DeltaV ™ Electronic Marshalling for Migrations
  • Emerson DeltaV Controller Redundancy Function
  • Emerson DeltaV Bulk Power Supplies
  • Emerson DeltaV SD Plus Controller
  • Emerson DeltaV M Series Virtual I/O Module 2 (VIM2)
  • Emerson DeltaV M Series MD Plus Controller
  • Emerson Ovation ™ Power system (5X00785G09)
  • Emerson DeltaV Intelligent Switch
  • Emerson A6110 Dual Channel Shaft Vibration Monitor
  • Emerson MMS 3210/xxx-xxx Dual Channel Shaft Position Transmitter for Eddy Current Sensors
  • Emerson MMS 3120 Dual Channel Bearing Vibration Transmitter
  • Emerson MMS 677X Dual Channel Bar Chart Indicator
  • Emerson Martens Standard Signal Instrument S 1010
  • Emerson CON021 Eddy Current Signal Converter Ordering Method!
  • How to order AMS 6500 Classic system protection card?
  • Emerson Machine Monitoring Systems RPM Transformer PR 9376
  • Emerson Linear Displacement Sensor PR 9350/.. Series
  • Emerson PR 9376 series eddy current sensor system
  • Emerson Electric Power Absolute Vibration Sensor (PR 9266/.. And PR 9268/..)
  • How to operate Emerson Motion Control FX 490?
  • Emerson The Ovation ™ What fields is the Control System applicable to?
  • Emerson Ovation Distributed Control System Input/Output (I/O) Module
  • Emerson HART High Performance Analog Input Module
  • Emerson Ovation ™ Controller Model OCR1100
  • Emerson PAC8000 Remote I/O
  • Emerson A6500-LC LVDT preamplifier
  • EMERSON A6370 Overspeed Protection Monitor
  • EMERSON A6110 axis relative vibration monitor
  • EMERSON FloBoss ™ S600+ Flow Computer
  • EMERSON CSI 2130 Machinery Health ™ Analyzer
  • AMS 2140 Machinery Health ™ How to operate Analyzer?
  • Emerson AMS Suite: Machinery Health ™ Manager v5.61 Software Installation Guide
  • GE Fanuc Series 90-30 Programmable Controller
  • GE PACSystems RX7i Controller
  • How to install GE Series 90-70 Genius Bus Controller?
  • GE VersaMax ® Programmable controller
  • GE VMIVME-7696 Pentium II processor based on VMEbus single board computer
  • GE VMIVME-7695 Single Slot Pentium II Embedded Module Processor
  • GE VMIVME-7459 Single Slot VME IDE CD-RW/Hard Disk Module
  • GE VMIVME-6016 VMEbus Intelligent 16 Channel Asynchronous Serial Controller
  • GE VMIVME-5620 Intelligent HSD Simulator
  • GE VMIVME-5588 high-speed reflective memory board
  • GE VMIVME-5532L VMEbus fiber optic repeater link
  • How to order GE VMIVME-5531L VMEbus fiber optic repeater link?
  • GE VMIVME-4514A 16 channel scanning analog I/O board
  • GE VMIVME-4150 isolated 12 channel 12 bit analog output board
  • GE VMIVME-3126 High Resolution Isolated Analog to Digital Converter Board
  • GE VMIVME-3100 16 channel 12 bit analog-to-digital converter board
  • What application areas is GE VMIVME-2540 24 Channel Intelligent Counter/Controller suitable for?
  • How to operate GE VMIVME-2511 programmable I/O board?
  • GE VMIVME-2510B 64 bit TTL digital I/O board
  • GE VMIVME-2128 128 bit high voltage digital output board
  • GE VMIMPC-5790 PMC Dual Channel Ultra160 SCSI Host Adapter
  • GE VMIVME-2170A 32-bit optically isolated digital output board
  • GE VMIPCI-5565 Ultrahigh Speed Fiber-Optic Reflective Memory with Interrupts
  • GE VMIACC-5595 2 Gb/s Reflective Memory Hub Component
  • GE VME-3125A Isolation Scan 12 Bit 32 Channel Analog to Digital Converter Board (6U)
  • GE VME-3122A High Performance 16 Bit Analog to Digital Converter (ADC)
  • GE VMIVME-2536 32 channel optically coupled digital I/O board
  • GE VMIVME-2528 128 bit TTL digital I/O TURBOModule ™
  • GE VMIVME-2232 32 32 channel relay output board
  • GE VMIVME-2210 64 channel latch or momentary relay board
  • GE VMIVME-1182 64 channel isolated digital input board
  • GE VMIVME-1128 128 bit high-voltage digital input board
  • GE VMIVME-111 64 bit High Voltage Digital Input Board
  • GE ACC-0603RC V7865 VME Rear Conversion Module
  • GE V7865 Intel ® Core ™ Duo Processor VME Single Board Computer
  • GE MVME5500 series VME single board computer
  • GE CPCI-7055RC PowerPC ® CompactPCI ® single board computer
  • GE VMIVME-3125 Analog Input Board
  • GE VMIVME-4105 8-Channel 12 Bit Multiplicative Digital to Analog Converter Board
  • GE VMIVME-5565 Ultra High Speed Fiber Reflective Memory (with Interrupt Function)
  • GE VMIVME-3122 High Performance 16 Bit Analog to Digital Converter (ADC)
  • GE VMIVME-2210 Relay Board
  • GE VMIVME-7648 Single Board Computer