Welcome to the Industrial Automation website!

NameDescriptionContent
HONG  KANG
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • PRO-FACE GP577R-TC41-24VP HMI Panel
    ❤ Add to collection
  • PRO-FACE GP577R-TC41-24VP HMI Panel

    ABB、GE、FANUC、Allen-Bradley、FOXBORO、Honeywell,KUKA、YOKOGAWA、YOKOGAWA、KOLLMORGEN、METSO、Motorola、NI、OEMAX、RELIANCE、Vibro-Meter、Rolls-Royce、MOOG、B&R、Woodward、Yaskawa、XYCOM、Emerson、HIMA、Bently、PROSOFT、TRICONEX、KEBA、Lenze、Alstom、CTI、DCSSystem accessories, robot system accessories, large servo system spare parts.
    Mr.FSN
    chnfcsXM@163.com
    +86-153-9626-8993
    Selection, installation, operation, maintenance, troubleshooting, safety
    Petrochemical/Chemical,Power industry,Metallurgical industry,Municipal/Environmental Protection,Oil and gas industry,Robot system accessories,automobile manufacturing,3C Electronics,Machining
    • ¥42337.00
      ¥45374.00
      ¥42337.00
      ¥42337.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:3.470KG
    • Quantity:
    • (Inventory: 5347)
Description
<span style="font-size: 18px; font-family: arial;">PRO-FACE GP577R-TC41-24VP HMI Panel</span>

PRO-FACE GP577R-TC41-24VP Touch Screen Operator Interface

The PRO-FACE GP577R-TC41-24VP is a high-performance operator interface terminal from the GP577R series, designed for industrial human-machine interaction applications. This rugged touchscreen panel combines a large format display with comprehensive connectivity options, enabling operators to monitor and control machinery effectively. The series includes multiple units including the GP477R-EG41-24VP variant, all sharing common design principles for industrial HMI deployment.

Display and Visual Specifications

The GP577R-TC41-24VP features a 10.4-inch TFT color LCD display offering 640 x 480 pixel resolution for clear, detailed visual presentation of process data, alarms, and control graphics. The display supports 64 colors, providing sufficient color differentiation for status indicators, trend displays, and alarm annunciation. The panel incorporates CCFL backlighting with an expected operational life exceeding 50,000 hours under continuous 24-hour operation, ensuring long-term reliability without frequent maintenance.

The touchscreen interface utilizes resistive touch technology, responding reliably to finger or gloved operation in industrial settings. The panel includes brightness control adjustable through four levels via the touch interface, accommodating varying ambient lighting conditions throughout the production day.


Memory and Storage

The GP577R-TC41-24VP incorporates 2 MB of FLASH EPROM internal memory for storing project data, screens, and system configuration. Backup memory consists of 256 KB of SRAM, preserving critical data during power loss. The unit includes a CF card interface for external storage, enabling convenient data logging, screen capture storage, project backup, and recipe management. This expansion capability allows operators to archive production data, transfer screen updates, and store system diagnostic information without connecting external computers.

Communication and Connectivity

The panel offers extensive communication options for integration with PLCs, drives, and other automation devices. The GP077-MLTE41 Ethernet interface provides 10/100Base-T connectivity for high-speed data exchange, remote monitoring, network integration, and connection to supervisory systems. The built-in serial port supports RS-232C and RS-422 communications, enabling flexible connectivity with various industrial controllers.

The FLEX NETWORK interface capability allows daisy-chaining of multiple Pro-face devices, simplifying system expansion and reducing cabling requirements. The panel can communicate with PLCs from multiple manufacturers including OMRON, Mitsubishi, Siemens, Allen-Bradley, and others through built-in drivers, eliminating the need for protocol converters in many applications.

Power and Environmental Specifications

The GP577R-TC41-24VP operates on a 24 VDC power supply with ±20% tolerance, providing resilience against typical voltage fluctuations in industrial environments. Power consumption is rated at 50 W maximum, with typical consumption of 20 W during normal operation. The allowable momentary power interruption duration is 20 ms or less, ensuring continued operation during transient power disturbances.

The panel’s front face meets IP65f protection rating per JEM 1030 and NEMA #250 Type 4X/12 standards, providing resistance to water jets, dust ingress, and corrosive atmospheres. This rating qualifies the unit for washdown areas, food processing environments, and other demanding industrial locations. The operating temperature range extends from 0 to 40°C, while storage temperatures range from -10 to 60°C. Ambient humidity tolerance is 30 to 85% RH non-condensing, and the operating atmosphere must be free of corrosive gases.

For insulation safety, the panel provides 10 MOhms or greater insulation resistance measured at 500 VDC between live conductor and grounding terminal. The dielectric strength rating is 1,000 VAC at 10 mA for one minute. Proper panel grounding with 100 Ohms or less resistance is required as per installation instructions.

Physical Installation

The GP577R-TC41-24VP is designed for upright panel mounting using natural air circulation cooling. Installation requires 100 mm of open space in all directions to maintain proper ventilation and prevent internal temperature rise beyond UL specification limits. The panel is CE-marked and cUL certified, with UL file number 2780027-02 for reference in compliance documentation. The interface and software tools Pro-face Editor or GP-PRO/PBIII support project development for this terminal series.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • MITSUBISHI ELECTRIC FR-A500 frequency converter
  • Laumas TLM8 weighing transmitter
  • Anybus X-gateway Configuration Manual
  • OMRON NJ/NX OPC UA Configuration Guide
  • OMRON NX series system unit power configuration and troubleshooting
  • FANUC 16i/18i/21i hardware connection and troubleshooting
  • PILZ PNOZmulti Safety Controller Maintenance Guide
  • MITSUBISHI ELECTRIC MELSEC A-series PLC Hardware Maintenance and Troubleshooting
  • Installation and troubleshooting of Renishaw PHC10-3 PLUS controller
  • Constellation HA Series Vacuum Transmission System Selection Guide
  • PILZ PNOZ m B0 configurable safety control system basic unit
  • BANNER BES58-6 series incremental encoder selection and troubleshooting guide
  • Classic PLC Maintenance: Practical Memory and I/O Configuration
  • Eaton LZM Circuit Breaker Selection and Engineering Guide
  • Pilz PSWZ X1P static monitoring
  • Keyence CV-3000 Visual System Selection
  • Pro face GP2000 Maintenance Guide
  • Siemens S120 frequency converter maintenance and configuration
  • Allen Bradley InterBus Module Configuration Guide
  • MX321 AVR Voltage Regulator Guide
  • GE MM2 Motor Manager Complete Guide
  • SIEMENS C500 microcontroller architecture and instruction set
  • HORIBA SEC-Z500X Mass Flow Controller
  • QUBE Servo 2 Teaching Experiment Platform
  • Schneider TSX17 serial communication upgrade and replacement
  • GE DC Drives (BCH series) upgrade and replacement of old DC drives
  • Honeywell X-DCS3000 Digital Integrated System Manager
  • OMRON Z500 high-precision contour measurement system
  • Siemens SIMATIC S5-90U/S5-95U Compact PLC
  • KEB F5 Elevator Driver Complete Guide
  • TOSHIBA VF-S15 Inverter Complete Guide
  • Complete Guide to SV-iG5A Inverter
  • Allen Bradley Guard PLC Safety System Practical Guide
  • Omron C1000H/C2000H PLC Practical Guide
  • Omron F160-2 Visual Expert Guide
  • Bonner Q45U Ultrasonic Sensor in Practical Use
  • Schneider C60H-DC Protector Practical Manual
  • Omron CPM2B Board PLC Practical Guide
  • Omron C500 PLC Installation and Maintenance Guide
  • Mitsubishi FXo/FXon PLC Hardware Practice
  • PULS QS40.241 Power Supply Practical Guide
  • Eaton XV-102-L Touchscreen Installation Guide
  • Omron FZ5 Vision System Selection and Configuration Guide
  • Schneider TSX47 series PLC selection
  • ABB CS31 distributed debugging
  • OMRON H8PR electronic cam debugging
  • OMRON MX2 frequency converter debugging
  • GP477R Engineering Installation
  • Siemens AS-i SlimLine Diagnostic Guidelines
  • OMRON NS Series PT Remote Access
  • OMRON Z4M sensor precision measurement
  • HIMMERWERK SINUS High Frequency Induction Heating Selection
  • OMRON CP1E PLC Practical Selection Guide
  • OMRON ZFX-C Vision Sensor in Practical Use
  • OMRON ZFV Intelligent Sensor Practical Guide
  • OMRON CJ Series PLC Practical Guide
  • Murr SIRCO Isolation Switch Selection Guide
  • OMRON ZFX Vision Sensor Engineering Practice
  • REER ULISSE UNC Security Light Curtain Practice
  • Siemens S5-90U/95U Fault Diagnosis and Advanced Programming
  • OMRON CPM2C system fault diagnosis and maintenance
  • Yaskawa ∑ - V Servo Drive Debugging Guide
  • OMRON CP1H PLC Practical Manual
  • OMRON K-type PLC Maintenance Guide
  • PEPPERL+FUCHS SLVA-4Kplus Safety Light Curtain Guide
  • Yaskawa ∑ - II Servo Drive Debugging Guide
  • Yaskawa VS-616PC5/P5 frequency converter practical application
  • OMRON 3G3SV Inverter Practical Manual
  • Pro face GP370 Complete Guide
  • OMRON FQ2 Smart Camera Selection Guide
  • Practical Guide to Sony SH800 Sorter
  • OMRON Cam Positioner Complete Guide
  • KEB F4 Inverter Debugging Guide
  • OMRON CJ series PLC operation and maintenance essentials
  • Essentials of Schneider C60H-DC DC DC Protector
  • OMRON 3G3MV Inverter Practical Guide
  • Essentials of OMRON CQM1H PLC System
  • Essentials of ARD Elevator Emergency Rescue Device
  • SolaHD SDN-D rail power supply
  • OMRON C200H PLC Troubleshooting and Programming Essentials
  • Allen Bradley 1336 PLUS Inverter Practical Guide
  • OMRON 3G3KV frequency converter
  • OMRON NSJ Integrated Controller
  • Megatiker M4 Circuit Breaker Maintenance
  • OMRON ZX laser sensor maintenance
  • Saia PCD1 Controller Maintenance Guide
  • OMRON NT Series HMI Replacement and Maintenance
  • Yaskawa F7 Driver Maintenance and Replacement
  • Rockwell 1494 switch selection replacement
  • Omron NA Series HMI Connection Guide
  • Eaton CV Series PLC System Upgrade and Diagnosis
  • Eaton XV-102 HMI Installation and Troubleshooting
  • Siemens SINUMERIK measurement cycle configuration
  • ELAU PacDrive C600 Controller Integration Guide
  • ELAU PacDrive SM Servo Motor Application and Maintenance Guide
  • Bently Nevada Orbit 60 System Upgrade and Troubleshooting Guide
  • YOKOGAWA STARDOM FCN-RTU Controller
  • Fireye InSight II Marine Flame Scanner
  • How to install ABB VSC vacuum contactor?
  • Rexroth Bosch Group VT2000 Proportional Amplifier
  • ALSTOM ALSPA series frequency converter
  • ABB SPACOM replaces REX615
  • Meggitt C327895 Gas Metering Valve Technology
  • Application of MOOG G77x servo valve
  • WOODWARD 2301E Digital Speed Controller
  • ABB UNITOL 1010/1020 AVR Compact IGBT Automatic Voltage Regulator
  • ABB UNITOL 6000 excitation system
  • Rexroth Bosch Group HNC100 Hydraulic Shaft Control
  • Lenze 8400 Inverter Debugging Guide
  • Panning Vacuum Sensor Maintenance Guide
  • SOGEVAC Rotary Disc Pump Maintenance Guide
  • THERMOVAC MEMS Vacuum Gauge Guide
  • TTR 101 Vacuum Gauge Troubleshooting Guide
  • Honeywell Beam Smoke Detector Guide
  • TURBOVAC Molecular Pump Maintenance Guide
  • Troubleshooting of Leuze electronic DDLS 200 optical transmission
  • Lam Harmonic Drive Quick Replacement Guide
  • LZS power replacement and troubleshooting
  • MTL2000 series isolation barrier
  • Temposonics GB Sensor
  • Temposonics R Series Magnetostrictive Displacement Sensor Depth
  • Original inventor of M ü ller Co ax AG coaxial valve
  • Murrelektronik Automation Solution Complete Solution
  • Nabtesco RV series high-precision gearbox
  • NACHI Robot Full Series
  • Electro hydraulic proportional directional flow valve
  • NEC FC-9801X Industrial Computer
  • Mark VIeS Security System