  • IC3600SFPB1 | General Electric Speedtronic Generator Drive Circuit Board
    ❤ Add to collection
  • IC3600SFPB1 | General Electric Speedtronic Generator Drive Circuit Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia
    IC3600SFPB1 | General Electric Speedtronic Generator Drive Circuit Board
    • ¥2352.00
      ¥6588.00
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.500KG
    • Quantity:
    • (Inventory: 3)
Description
IC3600SFPB1 | General Electric Speedtronic Generator Drive Circuit Board

IC3600SFPB1 | General Electric Speedtronic Generator Drive Circuit Board

Product Description P/N: IS215UCVGM09A Description / Specifications Description The IS215UCVGM09A, a DLAN+ (Drive Local Area Network Plus) Card developed by GE for the Mark VI system, is designed to fit into the 5 Vdc interface on "G" version Innovation controllers and the 3.3 Vdc interface on "H" version controllers. Typically installed near the bottom of the controller's faceplate, this two-sided board features a front faceplate with an ARCNET connector and a single multi-pin (male) connector. 

It securely fits into the motherboard's opening via two screw connections and is supported by standoffs installed in the motherboard's surface, connected with screw connections. This board is engineered to enhance buffering capability, thereby improving data rate and controller idle time, while also providing better noise rejection and higher receiver sensitivity for improved data quality. The IS215UCVGM09A offers electrical and physical interchangeability with previous DLAN+ modules. Technical Specifications Part Number IS215UCVGM09A Manufacturer General Electric Series Mark VI Type DLAN+ (Drive Local Area Network Plus) Card Compatible Interfaces 5 Vdc interface on "G" version of Innovation controllers
3.3 Vdc interface on "H" version of Innovation controllers Installation Position Near the bottom of the controller鈥檚 faceplate Board Sides Two-sided Information About IS215UCVGM09A The General Electric IS215UCVGM09A is a specialized DLAN+ (Drive Local Area Network Plus) Card, designed as part of the advanced Mark VI series, which is renowned for its robust capabilities in industrial automation and control systems. This card plays a critical role in enabling seamless communication and integration within drive systems, particularly in environments where high performance, reliability, and precision are paramount. 

Engineered by General Electric, a leader in industrial technology, the IS215UCVGM09A is crafted to meet the demanding requirements of modern industrial applications, ensuring optimal functionality in complex control architectures. The IS215UCVGM09A is designed to interface with the Innovation series controllers, specifically those utilizing the 5 Vdc interface on the "G" version and the 3.3 Vdc interface on the "H" version. This compatibility ensures that the DLAN+ card can be effectively integrated into various configurations, providing the flexibility needed to support a wide range of industrial setups. 

The card's ability to work seamlessly with these controllers underscores its versatility and its essential role in facilitating robust communication across drive systems. One of the key features of the IS215UCVGM09A is its installation position, which is strategically located near the bottom of the controller鈥檚 faceplate. This positioning is designed to optimize space utilization within the controller enclosure, allowing for easy access during installation and maintenance while ensuring that the card remains securely and efficiently integrated within the system. The thoughtful design of the installation position also helps in minimizing signal interference, contributing to the overall reliability and performance of the drive system. 

 The IS215UCVGM09A is constructed with a two-sided board design, which enhances its capability to handle complex signal processing tasks while maintaining a compact form factor. This dual-sided design allows for increased component density, enabling the card to deliver high-performance communication capabilities without compromising on space. The use of a two-sided board also contributes to improved thermal management, ensuring that the card can operate efficiently even in environments where temperature control is a concern. In terms of functionality, the IS215UCVGM09A DLAN+ card is integral to the efficient operation of drive systems within the Mark VI series. It facilitates high-speed communication between the controller and other components of the drive system, ensuring that data is transmitted accurately and in real-time. 

This capability is crucial for maintaining the synchronization and responsiveness of the system, particularly in applications where precise control over motor functions and process variables is required. The robust construction of the IS215UCVGM09A ensures long-term reliability, reducing the likelihood of failures and minimizing downtime in critical industrial operations. The card is designed to withstand the rigors of industrial environments, including exposure to electrical noise, vibrations, and temperature fluctuations. This durability makes the IS215UCVGM09A a dependable choice for industries such as manufacturing, power generation, and process automation, where consistent and reliable operation is essential. 

 In summary, the General Electric IS215UCVGM09A DLAN+ Card is a high-performance, versatile component designed to enhance the communication capabilities of drive systems within the Mark VI series. Its compatibility with various Innovation controllers, strategic installation positioning, and robust two-sided board design make it an essential tool for engineers and technicians seeking to optimize their industrial automation systems. By providing reliable and efficient communication within the drive network, the IS215UCVGM09A ensures that control systems operate smoothly and effectively, contributing to the overall success of industrial operations. Backed by General Electric's commitment to quality and innovation, this DLAN+ card offers the performance and reliability needed to meet the challenges of modern industrial environments. 

 Manufacturer information General Electric (GE) is a multinational conglomerate founded in 1892, based in the United States. It operates in various industries, including aviation, healthcare, renewable energy, and power. GE is known for its innovations in technology, manufacturing, and infrastructure solutions. IQElectro is not an authorized distributor. QElectro LLC (IQElectro) is NOT an Authorized Distributor or in any way affiliated with Rockwell Automation, Siemens, or any other Manufacturers. IQElectro is NOT an Authorized Dealer of this product. The product may be of older version, date codes, or design than that available from authorized dealers. As IQElectro is not an authorized dealer of this product, the Original Manufacturer's Warranty and Support DO NOT apply.IQElectro sells SURPLUS onlyand DOES NOT SELL SOFTWARE or FIRMWARE licenses For more detailed information, please refer to the full version of our disclaimer policy Disclaimer Policy.

  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module
  • Beckwith M-3520 Interconnection Protection Relay
  • Beckwith M-3430 Generator Protection Relay
  • Beckwith M-2293B adapter panel replacement GE regulator guide
  • Selection and Networking of Beckwith M-2001C Digital Voltage Regulating Controller
  • Beckwith M-2001B Digital Voltage Regulating Controller
  • Beckwith M-0388/M-0389 Synchronous Inspection Relay Application Guide
  • Beckwith M-0193B Synchronizer Debugging and System Integration Guide
  • Beckwith M-0115A Parallel Balance Module Debugging Guide
  • Beckwith M-0067E On Load Voltage Regulating Controller Selection and Debugging Guide
  • Debugging and Fault Handling of Beckwith M-4272 Digital Busbar Conversion System
  • Beckwith M-3311A Transformer Protection Relay Debugging Guide
  • Beckwith M-3425A Generator Protection Relay Debugging Guide
  • Setting and troubleshooting of Basler BE1-27/59 voltage relay
  • Debugging and troubleshooting of Basler AVC63-12/AVC125-10 voltage regulator
  • Basler L301kc Line Array Camera Technology and Troubleshooting
  • Selection and Debugging of Basler CBS 212A Current Boosting System
  • Selection and commissioning of Basler BE3-25 synchronous inspection relay
  • Basler BE1-32R/32O/U Direction Power Relay Setting and Testing Guide
  • Basler PRS 250 Synchronous Relay Maintenance and Replacement Guide
  • Basler piA2400-17gc Industrial Camera Replacement and Optimization Guide
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection
  • Basler SSR Static Voltage Regulator: A Complete Guide to Debugging and Troubleshooting
  • Basler SR4A/SR8A Voltage Regulator: Detailed Debugging and Troubleshooting Explanation
  • Basler BE2000E Voltage Regulator: Replacement and Application Details
  • Basler DECS-2100 Excitation System: Modular Upgrade and Engineering Application
  • Basler BE1-851 Overcurrent Protection System: A Complete Guide to Professional Debugging and Troubleshooting
  • Basler APR 63-5 Voltage Regulator: Professional Debugging and Troubleshooting Guide for Industrial Generator Excitation Systems
  • Basler BE1-FLEX Protection System: A Complete Guide to Professional Installation, Configuration, and Troubleshooting
  • Debugging and Testing of Basler BE1-700 Relay
  • Basler BE1-87B busbar differential setting test
  • Basler BE1-40Q demagnetization relay setting test
  • Basler BE1-60 Voltage Balance Relay Setting Test
  • Basler BE1-47N Relay Field Setting and Testing Guide
  • Basler BE1-81O/U Frequency Relay: On site Debugging and Protection Configuration Guide
  • Basler BE1-11f Feedline Protection System Debugging and Troubleshooting Guide
  • Basler DECS-250 Excitation System: Installation, Configuration, and Troubleshooting Practice Guide
  • Basler DECS-100 Digital Excitation System Debugging Guide
  • Application Guide for Basler BE1-BPR Circuit Breaker Protection Relay
  • Basler BE1-50/51B-255 Replacement CO Relay Guide
  • Basler BE1-25 synchronous inspection relay principle and testing
  • Basler BE1-51 Time Overcurrent Relay Debugging Guide
  • Practical Guide to Basler DECS-300 Digital Excitation System
  • Mitsubishi FX Series PLC Data Communication Practical Manual
  • Selection of Hirschmann cSCALE S6/C8 Mobile Safety Controller
  • Hirschmann OZD Profi G12D repeater explosion-proof installation configuration
  • Hirschmann OCTOPUS OS20/24 Switch Installation Power Supply
  • Hirschmann RS20/30/40 Switch Selection and PoE Deployment
  • Hirschmann EAGLE One Firewall Installation and Configuration Guide
  • Hirschmann MACH102 Switch Installation and Power Supply Guide
  • Hirschmann MICE MS20/MS30 Installation and DIP Configuration
  • Hirschmann BOBCAT BRS Switch Installation and Power Supply Guide
  • Hirschmann RSB20 Switch Deployment and Redundant Configuration
  • Hirschmann RS20 Basic Switch Installation and Debugging Guide
  • BECKHOFF EP20xx/EP28xx Output Module Installation and Debugging Guide
  • BECKHOFF EL5102 Encoder Terminal Debugging and Troubleshooting
  • BECKHOFF CU8803 Launch Box Installation and Explosion proof Guide
  • BECKHOFF CU20xx/CU22xx Switch Installation and Troubleshooting
  • BECKHOFF AMP8000 Servo Drive Installation and Debugging Manual
  • BECKHOFF EL2911 Safety Feed Terminal Debugging Guide
  • BECKHOFF EL600x/EL602x Serial Port Module Debugging Manual
  • BECKHOFF CP6700 Panel PC Installation and Maintenance Manual
  • BECKHOFF CP70xx panel maintenance and troubleshooting
  • BECKHOFF CP29xx Panel Installation and Troubleshooting
  • Beckhoff C6650-0060 Industrial Control Computer Hardware Architecture and RAID Data Security
  • Beckhoff BK1120/BK1250 EtherCAT Coupling Debugging and KL Terminal Parameterization Complete Guide
  • Beckhoff CX20x0 Embedded Controller Hardware Maintenance and Troubleshooting Complete Manual
  • Beckhoff CP77xx Panel PC Hardware Maintenance and Troubleshooting Complete Guide
  • Beckhoff EL41xx Analog Output Terminal Deep Analysis: Parameter Configuration, Fault Diagnosis, and Firmware Compatibility Guide
  • Beckhoff C63xx industrial computer power supply and shutdown configuration
  • Beckhoff C6920 Industrial Control Computer Selection and Expansion Guide
  • Beckhoff CU8800 USB extender diagnostic guide
  • Beckhoff AX2000 Shutdown Braking and Debugging
  • Beckhoff AX8000 servo installation fuse selection
  • Beckhoff CP27xx Multi finger Touch PC Maintenance
  • Beckhoff CP69xx long-distance transmission and installation
  • Beckhoff CP60xx remote deployment and maintenance
  • Beckhoff CP72xx Installation and Maintenance Complete Manual
  • Beckhoff CP78xx Installation and Troubleshooting Guide
  • Beckhoff CP39xx Control Panel
  • Beckhoff CX8110 Embedded PC
  • Beckhoff CX50x0 series DIN rail embedded industrial PC
  • Beckhoff CP62xx panel PC
  • BECKHOFF C6030 Industrial Control Computer
  • UniOP ePAD32B/ePAD33B/ePAD33BT Industrial HMI
  • UniOP ePAD05/06 Human Computer Interface
  • UniOP ePAD03/04 Human Computer Interface
  • UniOP BKDR-46-0045 Human Machine Interface
  • UniOP BKDR-16 human-machine interface
  • Beckwith M-3425A Relay Guide
  • Basler DECS-200-2L excitation system
  • Basler DECS-250 Excitation System Debugging Guide
  • HA-800A Servo Drive Debugging Guide
  • JUMO dTRANS p35 Manual
  • KEBA XE020 RFID Module Manual
  • Honeywell SmartLine Transmitter Complete Guide
  • Eaton CROUSE-HINDS Series MA30 Lightning Protection Filter Installation Guide
  • BECKHOFF EL31xx Series 16 Bit EtherCAT Analog Input Terminal Manual
  • BECKHOFF AX5000 Servo Drive Maintenance Guide
  • BECKHOFF EL30xx Analog Input Diagnostic Guide
  • BECKHOFF EL70x7 Stepper Terminal Maintenance Guide
  • BECKHOFF CX52x0 Industrial Control Computer Maintenance Guide
  • BECKHOFF CX9000/CX9010 Hardware Maintenance Guide
  • BECKHOFF AM8xxx Motor Guide