Welcome to the Industrial Automation website!

NameDescriptionContent
XING-Automation
E-mail  
Password  
  
Forgot password?
  Register
当前位置:
  • GE IS200TRLYS1D Relay Output with Coil Sensing Terminal Board
    ❤ Add to collection
  • GE IS200TRLYS1D Relay Output with Coil Sensing Terminal Board

    110V-380V
    5W-130W
    1A-30A
    1 year
    30
    United States, France, Japan, Viet Nam, Australia, Russia, Germany, Italy, Arabia

    GE IS200TRLYS1D Relay Output with Coil Sensing Terminal Board

    • ¥30495.59
      ¥30212.02
    • Satisfaction:

      Sales: 0

      Review: 0

    Weight:2.560KG
    • Quantity:
    • (Inventory: 26)
Description

GE IS200TRLYS1D Relay Output with Coil Sensing Terminal Board


GE IS200TRLYS1D Relay Output with Coil Sensing Terminal Board

Part Number IS200TRLYS1D Manufacturer General Electric Country of Manufacture As Per GE Manufacturing Policy Series Mark VI/VIe Function Module Availability In StockIS200TRLYS1D is a Relay Output Board developed by GE. It is a part of Mark VIeS control system. The terminal board is engineered with specific features to accommodate the needs of industrial applications requiring solenoid control and integrity sensing. 

The board is equipped with six plug-in magnetic relays, each featuring Form-C contact outputs. These relays are fused and powered to efficiently drive external solenoids, ensuring reliable operation in various industrial settings. Supported power sources include standard 24 V DC or 125 V DC, providing flexibility in power supply options to suit specific application requirements. FEATURES Solenoid Integrity Sensing: Special feedback mechanisms are integrated into each relay circuit to detect potential issues with external solenoids. This sensing capability, performed between the normally open (NO) output terminal and the solenoid (SOL) output terminal, allows for proactive maintenance and troubleshooting by identifying faulty solenoids. 

Six-Relay Configuration: The board features six relays, providing expanded relay capacity beyond the standard configuration. This increased relay count offers greater flexibility and versatility in system design and operation. Compatibility with 24/125 V DC Applications: Designed specifically for 24/125 V DC applications, the board ensures compatibility with specific voltage requirements, ensuring optimal performance and reliability in targeted applications. 

Dual Normally Open (NO) Contacts: Relay circuits include a normally open (NO) contact on both the source side and the return side. This configuration enhances flexibility and functionality in controlling external devices and circuits. Non-Configurable for Dry Contact Use: The relays are not configurable for dry contact use, ensuring compatibility with the intended application. This design choice streamlines installation and eliminates potential compatibility issues. emoval of Input Relay Coil Monitoring: Input relay coil monitoring is removed from the board, streamlining its functionality for solenoid control and integrity sensing. This optimization enhances operational efficiency and simplifies maintenance procedures. 

Field Solenoid Integrity Monitoring: The terminal board provides monitoring of field solenoid integrity, enhancing system reliability and safety. This feature ensures that solenoids are functioning correctly, reducing the risk of malfunctions and downtime. Exclusion of Special-Use Relay for Ignition Transformer: The board does not include a special-use relay for driving an ignition transformer. Instead, it focuses on solenoid control and integrity monitoring, ensuring optimized performance for its intended application. INSTALLATION Relay Output Connection Connect the wires for the six relay outputs directly to the TB1 terminal block on the terminal board. 

The TB1 block is securely held down with two screws and features 24 terminals designed to accept wires up to #12 AWG, providing ample space for wiring connections. Ensure proper alignment and secure attachment of the wires to the terminal block to prevent loose connections or electrical hazards. Grounding Adjacent to the TB1 terminal block, locate the shield terminal strip attached to chassis ground. Properly ground the terminal board by connecting it to the shield terminal strip, enhancing safety and minimizing the risk of electrical interference. 

 Solenoid Power Connection Connect the solenoid power for outputs 1-6 to JF1, ensuring proper polarity and secure connections. JF2 can be utilized to daisy-chain power to other TRLYS1D boards, providing a convenient and streamlined power distribution solution. Avoid using TB3 for solenoid power connection to prevent potential issues or conflicts. Final Checks Double-check all connections to ensure they are secure and properly aligned. Verify that the wiring configuration complies with the specifications and requirements of the application. Perform thorough testing to confirm proper functionality of the relay outputs and solenoid power supply.

SPECIFICATIONS:

Part Number: IS200TRLYH1D
Manufacturer: General Electric
Series: Mark VIe
Number of relay channels: 12
Rated voltage on relays: 125 V dc
Dimensions: 17.8 cm wide x 33.02 cm high
Operating Temperature: -30 to + 65oC
Controller and I/O module Redundancy: Simplex
Internal operating system: QNX
Power Consumption: 4 W
Analog outputs: 0 to 10 V
Configuration Software: ToolboxST
Country of Manufacture: United States (USA)
Availability: In Stock
Manual: GEH-6421 M


  • User name Member Level Quantity Specification Purchase Date
  • Satisfaction :
No evaluation information
  • Modular Architecture Analysis of DEIF PPU 300 Ship Generator Controller
  • DEIF DM-4 Marine&Offshore Ship Power Management System
  • Detailed Explanation of DEIF Delomatic Generator Control System Architecture
  • DEIF AGC-4 Mk II Generator Controller Depth Configuration Guide
  • DEIF AGC-4 Generator Controller Configuration and Debugging Guide
  • DEIF PPM Power Management System Operation and Troubleshooting
  • Installation and wiring of DEIF Multi line 2
  • Practical configuration and maintenance of Beckwith M-6280 capacitor bank controller
  • Beckwith M-3311 Transformer Protection Relay Setting and Engineering Application
  • Beckwith M-3311A Transformer Protection Relay Configuration and Optimization Guide
  • Beckwith M-3310 Transformer Protection Relay Complete Guide
  • Beckwith M-0359 synchronous inspection relay
  • Beckwith M-0293A Voltage Regulating Controller Replacement and Debugging Guide
  • Complete Guide to DEIF GPU-3 Generator Protection Unit
  • Installation and I/O configuration of DEIF PPM-3 power management module
  • Beckwith M-3520 Interconnection Protection Relay
  • Beckwith M-3430 Generator Protection Relay
  • Beckwith M-2293B adapter panel replacement GE regulator guide
  • Selection and Networking of Beckwith M-2001C Digital Voltage Regulating Controller
  • Beckwith M-2001B Digital Voltage Regulating Controller
  • Beckwith M-0388/M-0389 Synchronous Inspection Relay Application Guide
  • Beckwith M-0193B Synchronizer Debugging and System Integration Guide
  • Beckwith M-0115A Parallel Balance Module Debugging Guide
  • Beckwith M-0067E On Load Voltage Regulating Controller Selection and Debugging Guide
  • Debugging and Fault Handling of Beckwith M-4272 Digital Busbar Conversion System
  • Beckwith M-3311A Transformer Protection Relay Debugging Guide
  • Beckwith M-3425A Generator Protection Relay Debugging Guide
  • Setting and troubleshooting of Basler BE1-27/59 voltage relay
  • Debugging and troubleshooting of Basler AVC63-12/AVC125-10 voltage regulator
  • Basler L301kc Line Array Camera Technology and Troubleshooting
  • Selection and Debugging of Basler CBS 212A Current Boosting System
  • Selection and commissioning of Basler BE3-25 synchronous inspection relay
  • Basler BE1-32R/32O/U Direction Power Relay Setting and Testing Guide
  • Basler PRS 250 Synchronous Relay Maintenance and Replacement Guide
  • Basler piA2400-17gc Industrial Camera Replacement and Optimization Guide
  • Basler BE1-11g Generator Protection System
  • Basler VR63-4C/UL Voltage Regulator
  • Basler BE1-DFPR feeder protection relay
  • Basler CBS 310/320 Current Boosting System
  • Basler UFOV 250A/260A protection module
  • Basler MVC104/MVC108/MVC232 manual voltage control device
  • Basler XR2002/XR2002F Regulator
  • Basler DECS-400 excitation system
  • Basler DGC-2020 Generator Set Controller: Integrated Control and Debugging Guide
  • Basler MVC-300 Manual Voltage Controller: Characteristics and Engineering Applications
  • Basler MVC Series Manual Voltage Controller: Application and Selection
  • Basler SSR Static Voltage Regulator: A Complete Guide to Debugging and Troubleshooting
  • Basler SR4A/SR8A Voltage Regulator: Detailed Debugging and Troubleshooting Explanation
  • Basler BE2000E Voltage Regulator: Replacement and Application Details
  • Basler DECS-2100 Excitation System: Modular Upgrade and Engineering Application
  • Basler BE1-851 Overcurrent Protection System: A Complete Guide to Professional Debugging and Troubleshooting
  • Basler APR 63-5 Voltage Regulator: Professional Debugging and Troubleshooting Guide for Industrial Generator Excitation Systems
  • Basler BE1-FLEX Protection System: A Complete Guide to Professional Installation, Configuration, and Troubleshooting
  • Debugging and Testing of Basler BE1-700 Relay
  • Basler BE1-87B busbar differential setting test
  • Basler BE1-40Q demagnetization relay setting test
  • Basler BE1-60 Voltage Balance Relay Setting Test
  • Basler BE1-47N Relay Field Setting and Testing Guide
  • Basler BE1-81O/U Frequency Relay: On site Debugging and Protection Configuration Guide
  • Basler BE1-11f Feedline Protection System Debugging and Troubleshooting Guide
  • Basler DECS-250 Excitation System: Installation, Configuration, and Troubleshooting Practice Guide
  • Basler DECS-100 Digital Excitation System Debugging Guide
  • Application Guide for Basler BE1-BPR Circuit Breaker Protection Relay
  • Basler BE1-50/51B-255 Replacement CO Relay Guide
  • Basler BE1-25 synchronous inspection relay principle and testing
  • Basler BE1-51 Time Overcurrent Relay Debugging Guide
  • Practical Guide to Basler DECS-300 Digital Excitation System
  • Mitsubishi FX Series PLC Data Communication Practical Manual
  • Selection of Hirschmann cSCALE S6/C8 Mobile Safety Controller
  • Hirschmann OZD Profi G12D repeater explosion-proof installation configuration
  • Hirschmann OCTOPUS OS20/24 Switch Installation Power Supply
  • Hirschmann RS20/30/40 Switch Selection and PoE Deployment
  • Hirschmann EAGLE One Firewall Installation and Configuration Guide
  • Hirschmann MACH102 Switch Installation and Power Supply Guide
  • Hirschmann MICE MS20/MS30 Installation and DIP Configuration
  • Hirschmann BOBCAT BRS Switch Installation and Power Supply Guide
  • Hirschmann RSB20 Switch Deployment and Redundant Configuration
  • Hirschmann RS20 Basic Switch Installation and Debugging Guide
  • BECKHOFF EP20xx/EP28xx Output Module Installation and Debugging Guide
  • BECKHOFF EL5102 Encoder Terminal Debugging and Troubleshooting
  • BECKHOFF CU8803 Launch Box Installation and Explosion proof Guide
  • BECKHOFF CU20xx/CU22xx Switch Installation and Troubleshooting
  • BECKHOFF AMP8000 Servo Drive Installation and Debugging Manual
  • BECKHOFF EL2911 Safety Feed Terminal Debugging Guide
  • BECKHOFF EL600x/EL602x Serial Port Module Debugging Manual
  • BECKHOFF CP6700 Panel PC Installation and Maintenance Manual
  • BECKHOFF CP70xx panel maintenance and troubleshooting
  • BECKHOFF CP29xx Panel Installation and Troubleshooting
  • Beckhoff C6650-0060 Industrial Control Computer Hardware Architecture and RAID Data Security
  • Beckhoff BK1120/BK1250 EtherCAT Coupling Debugging and KL Terminal Parameterization Complete Guide
  • Beckhoff CX20x0 Embedded Controller Hardware Maintenance and Troubleshooting Complete Manual
  • Beckhoff CP77xx Panel PC Hardware Maintenance and Troubleshooting Complete Guide
  • Beckhoff EL41xx Analog Output Terminal Deep Analysis: Parameter Configuration, Fault Diagnosis, and Firmware Compatibility Guide
  • Beckhoff C63xx industrial computer power supply and shutdown configuration
  • Beckhoff C6920 Industrial Control Computer Selection and Expansion Guide
  • Beckhoff CU8800 USB extender diagnostic guide
  • Beckhoff AX2000 Shutdown Braking and Debugging
  • Beckhoff AX8000 servo installation fuse selection
  • Beckhoff CP27xx Multi finger Touch PC Maintenance
  • Beckhoff CP69xx long-distance transmission and installation
  • Beckhoff CP60xx remote deployment and maintenance
  • Beckhoff CP72xx Installation and Maintenance Complete Manual
  • Beckhoff CP78xx Installation and Troubleshooting Guide
  • Beckhoff CP39xx Control Panel
  • Beckhoff CX8110 Embedded PC
  • Beckhoff CX50x0 series DIN rail embedded industrial PC
  • Beckhoff CP62xx panel PC
  • BECKHOFF C6030 Industrial Control Computer
  • UniOP ePAD32B/ePAD33B/ePAD33BT Industrial HMI
  • UniOP ePAD05/06 Human Computer Interface
  • UniOP ePAD03/04 Human Computer Interface
  • UniOP BKDR-46-0045 Human Machine Interface
  • UniOP BKDR-16 human-machine interface
  • Beckwith M-3425A Relay Guide
  • Basler DECS-200-2L excitation system
  • Basler DECS-250 Excitation System Debugging Guide
  • HA-800A Servo Drive Debugging Guide
  • JUMO dTRANS p35 Manual
  • KEBA XE020 RFID Module Manual
  • Honeywell SmartLine Transmitter Complete Guide
  • Eaton CROUSE-HINDS Series MA30 Lightning Protection Filter Installation Guide
  • BECKHOFF EL31xx Series 16 Bit EtherCAT Analog Input Terminal Manual
  • BECKHOFF AX5000 Servo Drive Maintenance Guide
  • BECKHOFF EL30xx Analog Input Diagnostic Guide
  • BECKHOFF EL70x7 Stepper Terminal Maintenance Guide
  • BECKHOFF CX52x0 Industrial Control Computer Maintenance Guide
  • BECKHOFF CX9000/CX9010 Hardware Maintenance Guide
  • BECKHOFF AM8xxx Motor Guide