The LTi SO84.016 marks the entry into BG3 housing size, offering 16A continuous and 32A peak current. It is available in both air-cooled and liquid-cooled variants, allowing integration into standard cabinets or water-cooled environments. The three-phase input accepts 230V to 480V AC.
Rated current: 16 A (400V, 8 kHz), peak: 32 A (0-5 Hz)
Flexible cooling: air (BG3) or liquid (BG3 liquid cooling option)
BG3 dimensions: width 130 mm, height 345 mm, depth 242 mm (air) / 198.3 mm (liquid)
Integrated brake chopper with higher power capability
External braking resistor minimum: 20 Ω (for 400V mains)
DC link capacitance: 1230 μF (air) / 1230 μF (liquid)
Mains: 3 x 230/400/460/480V AC ±10%
Rated current (IN): 16 A
Peak current: 32 A (intermittent)
Connected load: 11.1 kVA (with mains choke)
Power loss: 195 W (at IN, 8 kHz)
Brake chopper threshold: 650V DC (400V mains) / 820V DC (460/480V)
Minimum external braking resistor: 20 Ω
Continuous braking power (external): 21 kW
Dimensions: 130 x 345 x 242 mm, weight 6.5 kg

The liquid-cooled SO84.016 operates with coolant temperature 5°C to 40°C, nominal flow 3 l/min, max pressure 2 bar. Shutdown temperature at heat sink is 65°C. This version is ideal for sealed cabinets or high ambient temperatures. It shares the same electrical ratings but offers reduced heat dissipation into the cabinet.
Control supply: 24V DC (6A start, 2A continuous)
Digital inputs: 6 (2 high-speed probe)
Digital outputs: 3 (50 mA high-side)
Analog inputs: 2 differential (±10V, 12-bit)
Resolver (X6) and high-resolution encoder (X7)
Motor brake output: 24V / 2A
USB, Ethernet, MMC slot, option slots for fieldbus
For air-cooled: maintain 150 mm clearance above and below. For liquid-cooled: connect cooling circuit with 3/8 inch female thread; use drip-free quick-release nipples. The liquid capacity of the device is up to 0.5 l. Ensure the coolant meets requirements (drinking water + corrosion inhibitor, chloride ions<100 ppm).
Commission with DriveManager 5. The 7-segment display guides parameter setting. STO (Safe Torque Off) is standard. For applications requiring frequent regenerative braking, the external braking resistor must be sized accordingly. The brake chopper continuous power is 21 kW (external resistor).
Suitable for motors up to 5 kW (400V). Typical uses include CNC axes, printing presses, converting machines, and test stands. The liquid-cooled version is preferred in dusty or washdown environments where fan cooling is problematic.
Complies with 2006/95/EC, 2004/108/EC, EN 61800-5-1, EN 61800-3 (C2/C3). UL approval for BG3 is in progress.
The LTi SO84.016 offers a robust and scalable platform for medium-power servo applications.